Jun Aux TV kelangan ko lang ng automation kaya gamit ko Sonoff. Example: water pump, fan, etc. May sensors din ako. Gamit ko HASS. Check mo Home Assistant.
Jun Aux TV hindi naman sobrang special pero example yung pump eh mas OK kung may switch sa phone lang or isang smart switch sa banyo na pwedeng control yun. Ang mga Sonoff Pow actually eh pwede lang sa low wattage.
salamat sa information lods, kelangan talaga alam yan lalo na ng mga electrician. pero my times kaya nasusunog ang isang outlet is loose, lalo na kung malaki ang load. malaki pero pasok naman sya sa allowable amps nya.
Good day. Boss mahilig ako mag DIY. Very informative mga toturial videos mo. May question sana ako, pwede ba ako maglinya ng 3gang switch with 3 convince outlet na naka top lang sa isang light switch?
@@reggie7725 I agree also with mr diy. I doubt also if meralco or napocor used GFCIs, ELCBs in their buildings/offices which are electrical safety device. During my vacation in Philippines, I've noticed they have now R-Y-B code on 13.8KV overhead feeder lines. Meralco required 10-12 awg solid earth or ground conductor/white insulation, together with 2 hot line stranded conductor with 8 awg with extra length for drip loop from weathercap and termination for meterbase for a 40 amps residential load.
@@reggie7725 whatever company it is, as long as their design is in accordance with its national not international standards or requirements it can be. I've been working in certain projects HOLCIM, NATIONAL STEEL CORPORATION/GLOBAL STEEL more than decade and haven't seen in their installations. Perhaps they have now if they upgraded to IEC.
Sir salamat po sa idea.. Ask kang po pwd ba lagyan ng switch tv.. Amplifier..mega vision.. Lagyan ko sana ng switch pwed po bha?...kung pwed po anong switch po ang gagamitin.. Salamat po
Ang 80% doon mo lang iapply sa breaker kasi yun ang nagtrip. Sa switches , at outlet rating hindi mo na kilangan applyan ng 80% basta hindi lalampas sa rating. Ex. 10A ang rating switch pwede mo lagyan ng 9.5A
Sir jun? Tanong lang po, Example sa isang plate may 2 gang outlets, yung 2 gang outlets po ba ang carrier ng 2000watts or kada 1 Gang outlets may 2000watts
thanx sa lecture,,,sana yung wire naman ang capasidad ng watts at amperes,,at yung computataion ng ohms power watts at voltages,please pa shout out po ako
Sa Octopus po sir kaya nya po na reach yung maximum aphere rating nya dahil pag octopus po yung connection magkakaroon po sya voltage drop. Pag bumamaba ung voltage tataas ung current nag vavary po kasi ung voltage tsaka current kaya po na reach nya or nag exceed sya sa 8amps na rating kaya nasusunog sya 😊
sir, ang pinaka safe sa isang swith wla po yan sa watage kase sobrang dami ang pede mo ikabit kng watage ang pgbabasihan, mahirap n yan e troubleshoot mdamay ang ibang ilaw kpag mg off ka ng breaker sa cercuit po tyo mg base 10 to 12 lumps or bulb lng po ang pede ntin ikabit sa isang cercuit slmat
Kung yang 10-12 bulb na sabi mo ang basihan para di masunog ang switch na 16amp ang capacity,ang wattage ng bulb mo ay 500? =6,000watts/230v=26amps,sunog ang switch mo na 16amps lang ang capacity.kaya dapat alam mo ang wattage hindi sa dami ng bulb.
God bless jun .sana mgpatoloy kp gumawa ng tutorial vedio marami . My tanong lng ako regarding circuit breaker .for example un outdoor breaker k is 30 amper..kailangan b un main breaker k s indoor ay 30 dn
pag AC walang polarity yun brad. Sa ibang bansa may color coding ang hot wire at return wire, pero ang purpose nun is para madali makita kapag may maintenance hindi sya polarity.
Sir ano ba ang dapat gamitin na extension wire and outlet para sa inverter welding machine na 300A? Kailangan paba ito gamitan ng magnetic Contactor? Thankz...
Di na kailangan kwentahin pa yan kasi alam mo na ang capacity ng switch Ng i follow nyo ang PEC standard .kHit kayanin pa nya mataas na ampere ang pagbabasehan pa rin ang standard dahil iyon amg pina ka safe
Me as an e&i technician hindi q inaadvice na ganun k.rami ang ilaw na gagamitin...tama ka po sir lung mg.babase tayo sa specification ng isang device kung ilan ang maximum capacity nya may point ka don kase tama yung computation mo sir...pero yung point q...mgmamatter pa rin ang haba ng cable na ggamitin sa isang circuit sir..isa pa during maintenance dagdag trabaho kase halimbawa ngkaproblema ang isang circuit ng ilaw na may 15 lighting fixture ibig sabihin imbis na m.bilis ang troubleshooting, sa dami ng ilaw na kinabit hustle pa..another thing na nakita q kung ganyan karami ay kung halimbawa ang switch ang bumigay...edi lahat ilaw m.wawalan ng supply...tsaka sir alam q gusto mo lng ibahagi ang k.alaman mo pero pwede bang respetohin mo nmn ibang electrician?..wag mong sabihin na d lahat ng electrician alam to..ampangit pakinggan sir..ang labas eh ikaw na ang magaling...baka maraming electrician na mas may alam pa sayo sir m.papahiya ka lng...hindi mo ako basher sir gusto q lng liwanagin na hindi lahat ng nk.k.panood nito mga baguhang electrician...yung ibang nk.k.panood nito matagal na sa larangan ng kuryente kaya sana wag ganyang mga caption....salamat sir..asallamu alaikom
Tama po kau jan sir... lalo na sa switch.. not advisable na lagyan yan ng pagkadami daming lights... My standard procedure parin pong sinusunod mga electricians.... saka po ung caption nio tibay, hahaha.. Pero salamat na din po sa info..
Sir gud pm po halimbawa po naglilinya ka po na nakabukas po yung breaker sa main switch po pwd mo po bang hawakan ang isang linya may kuryente po ba yun at kung isang linya ay nakatugtong na po sa isang linya po i mean line 1 sa line 1 yung line 2 idudugtong mo pa lng gamit ang kamay makukuryente ka po ba salamat po sa Dios gandang gabi
Hi mam... technically meron pong way but kahit sinu pong license Electrical practitioner hindi po namin nirerecommend yan at hindi din po namin pinapractice...mas maganda po na safe po tayo palage...
Electrician din po ako regstrd..pro pinapanood Kita lage..keep the good work..godbless
Maraming salamat din po sir...
Salamat sir malaking tulong ang mga vlog mo sa mga gaya kung walang alam sa electrical.
Salamat. Nag-aaral ako ng load computation.
Marami akong binili na Sonoff Pow R2. Nakakatulong talaga sa pag-estimate ng power consumption.
May special devices po ba kayo mam na ginamit?
Jun Aux TV kelangan ko lang ng automation kaya gamit ko Sonoff. Example: water pump, fan, etc. May sensors din ako. Gamit ko HASS. Check mo Home Assistant.
Jun Aux TV hindi naman sobrang special pero example yung pump eh mas OK kung may switch sa phone lang or isang smart switch sa banyo na pwedeng control yun. Ang mga Sonoff Pow actually eh pwede lang sa low wattage.
salamat sa information lods, kelangan talaga alam yan lalo na ng mga electrician.
pero my times kaya nasusunog ang isang outlet is loose, lalo na kung malaki ang load.
malaki pero pasok naman sya sa allowable amps nya.
ayos galing sir ganito mga videos dapat ang sinusuportahan lalo sa mga skilled worker ofw para hindi tayo mapag iwanan nang mga ibang lahi abroad..
Instablaster.
Sir salamat ..may alam na ako sa video mo salamat sa guide at kaalaman mo sir...electrician po ako dito sa davao...amping always..
Good thanks galing may natutunan ako.
Salamat sa video mo sir, nadagdagan yong aking kaalaman,
Tanong ko nga pla anong purpose ng breaker, at kung paano ito mag automatic shutdown?
Maraming salamat Sir , OK po ung demo nyo napakaganda at may natutunan talaga ako, sanapo meon pa kaung ibang mai video.
Madame pa sir...hehe
Salamat sayo idol sa genawa mong vedio my natotonan na nman amo
andami ko talaga nalalaman sa channel na toh thanks lodi 😉
Salamat din po sir
salamat po sa mga video n ipipalabas po nyo nakktulong po samin yang mga pinapalabas po nyo
maraming salamat din po
Thank you Sir Jun😊 mayron na Naman kaming natutunan po sayo.
Maraming salamat din po sir
SALAMAT SIR SA LAHAT NG TUTORIAL MO.
sir thanks s yong video nkaka pulot idea god bless di k madamot sir
Salamat din po sir
Slamat boos electrician Hindi q rin po alam Salamat info may idea naq thanks
Thanks sa info sir. It was a clear presentation for a safety lightings.
Sir Jun..thank u po.lagi ko pinapanood video mo..
maraming salamat po sir
Sir jun.pwd po ba gawa kau Ng control Ng submersible pump na may kasamang float switch..thank u po sir jun
maraming salamat sir,dami ko pong natutunan sa inyo
Maraming salamat din po
Tnx sa malupet mong lecture... ❤❤❤❤❤❤❤
Galing Master,my nalaman ako sau, Salamat 👍👍
Maraming buzzer pero ako namumulot ako ng good idea para magamit ko rin in future
Salamat SA impormasyon kuya.. godbless po
Salamat sa mga kaalaman boss
Good day. Boss mahilig ako mag DIY. Very informative mga toturial videos mo. May question sana ako, pwede ba ako maglinya ng 3gang switch with 3 convince outlet na naka top lang sa isang light switch?
salamat sir at pinagbigyan mo yung request ko salamat ng marami may natutunan nanaman ako salamat
Salamat din po sir...
God bless you Jun. patuloy molang yang kabutihang ginagawa mo
Maraming salamat po sir...God bless us all
Thanks sa impormasyon ngayon ko lang di na laman. God bless
Happy New Year,Sir.paano po ba maglagay ng 110 volts outlet from the existing 220 volts outlet.thanks
tnx po sa information
Oks lang.. happy fathers day.
Happy father's day 🎉 din po sir
magbasi tayo lagi sa P E C pero ok yong turo mo boss
pls always set ur mind in standard set by PEC-Philippine Electrical Code, para safe. in doing some electricity stuff..
Tnx for reminding us sir...tnx
Tama ko po diyan sir
@@reggie7725 I agree also with mr diy. I doubt also if meralco or napocor used GFCIs, ELCBs in their buildings/offices which are electrical safety device. During my vacation in Philippines, I've noticed they have now R-Y-B code on 13.8KV overhead feeder lines. Meralco required 10-12 awg solid earth or ground conductor/white insulation, together with 2 hot line stranded conductor with 8 awg with extra length for drip loop from weathercap and termination for meterbase for a 40 amps residential load.
@@reggie7725 whatever company it is, as long as their design is in accordance with its national not international standards or requirements it can be. I've been working in certain projects HOLCIM, NATIONAL STEEL CORPORATION/GLOBAL STEEL more than decade and haven't seen in their installations. Perhaps they have now if they upgraded to IEC.
Sir salamat po sa idea.. Ask kang po pwd ba lagyan ng switch tv.. Amplifier..mega vision.. Lagyan ko sana ng switch pwed po bha?...kung pwed po anong switch po ang gagamitin.. Salamat po
Ok master my natutunan
Salamat sir
Salamat idol sa pag reply sakin nun nakraan..
ayos boss,may natutunan nmn ako salamat po.
Boss good thanks galing mo
Thanks for sharing, new subscriber
Sir another learning nanamn thanks to your master
Maraming salamat din po sir
Maraming pong salamat Jun sa clkear mong explaination.
Salamat din po sir
Klaro b un . Mali nman un
Ang 80% doon mo lang iapply sa breaker kasi yun ang nagtrip. Sa switches , at outlet rating hindi mo na kilangan applyan ng 80% basta hindi lalampas sa rating. Ex. 10A ang rating switch pwede mo lagyan ng 9.5A
Sir jun? Tanong lang po,
Example sa isang plate may 2 gang outlets, yung 2 gang outlets po ba ang carrier ng 2000watts or kada 1 Gang outlets may 2000watts
sir jun dapat 100 watts ang kwentada bawat ilaw para safety. request lng sir jun sana actual naman...
God bless po gumaling ang pamamalat
More vedios pa master godbless.
Thanks sir sa pag explain kung bakit Max 10 c.o lang per circuit gagamitin :D
Salamat din po sir
if you do not understand consult the Phil. Electrical Code that is the only authority regarding electrical regulations
Sna mapansin mo tong tanong ko Sir Jun.. Ano po ba ung mga dapat na nka separate circuit.. like ACU? etc.. Residential
Lighting 15 amp. Convenience outler 30 amps.ref 30 amps. Range 30 amps. Aircon 30 amps. Water motor 30 amps
thanx sa lecture,,,sana yung wire naman ang capasidad ng watts at amperes,,at yung computataion ng ohms power watts at voltages,please pa shout out po ako
Noted po sir... maraming salamat po sir
May table din po tayo jan sir
Maganda rin mga video sir ..kaya lang medyo mahina boses mo sir.... medyo lakas lakasan mo sir boses mo .....salamat po...
Ang galing u idol..
Tama boss..
May natutunan ako dahil.
EIM AKO.......more videos to come
Salamat sir
hello sir Jun may video po ba kayo Kung paano connection ng exhaustfan sa ceiling para po sa cr? kahit diagram lang po salamat.
Wala po sir
Pra lng po yang ilaw ang conection nia. Kapag gusto mong mayroon siyang swith.pede ring direct s outlet pag wlng gamit n switch
Please post more.😀
Sana next naman master obout firealarm,
thanks sa info idol 👍👍
Salamat din po sir
Second thought kung minsan loose connction between adapter and plug itself kaya may burn out ung outlet.
galing mo master ..tuloy mo LNG yn sir
Maraming salamat po sir...
Sa convinience outley 8maximun at sa lighting outlet 10sa isang homerun.
Good job bro ,ask k lng ano b o gaano b kataas dapat ang outlet s Flor o ground
May post ako sa Facebook page natin sir Jun Aux TV din po name.... important guildlines title nandon lahat sir...
30 cm boss
Ok lang po Master.. Salamat din.
slamat po
Pwd ba gamitin ung 10A 16A na outlet dun sa #12 wire na ung breaker 20A?
Sa Octopus po sir kaya nya po na reach yung maximum aphere rating nya dahil pag octopus po yung connection magkakaroon po sya voltage drop. Pag bumamaba ung voltage tataas ung current nag vavary po kasi ung voltage tsaka current kaya po na reach nya or nag exceed sya sa 8amps na rating kaya nasusunog sya 😊
Tama po kayo sir....
pag bumaba ang voltage tataas ang current ? 🤔
Sir ganda ng calc mo. Anong brand yan, magkano at saan mabibili po. Salamat
install ka ng calculator app sa playstore if Android ka
Boss tanong lang saan mo kinuha ang 230?
It mean sir yung 500 watts mercury lamp ok yun gamitin
sir, ang pinaka safe sa isang swith wla po yan sa watage kase sobrang dami ang pede mo ikabit
kng watage ang pgbabasihan, mahirap n yan e troubleshoot mdamay ang ibang ilaw kpag mg off ka ng breaker
sa cercuit po tyo mg base
10 to 12 lumps or bulb lng po ang pede ntin ikabit sa isang cercuit
slmat
Sir ilang amps OCPD mo sa 10 to 12 bulb sa isang circuit?
tama ka sir. sa work ko. LED 15watts / 11pcs tapos breaker 15amps..
Kung yang 10-12 bulb na sabi mo ang basihan para di masunog ang switch na 16amp ang capacity,ang wattage ng bulb mo ay 500? =6,000watts/230v=26amps,sunog ang switch mo na 16amps lang ang capacity.kaya dapat alam mo ang wattage hindi sa dami ng bulb.
@@victorianoarandid6234 saan ka ba makakakita ng ilaw na 500w sa residential? ibig nya sabihin capacity ng CB
maraming salamat sayo bro
Salamat din po sir
God bless jun .sana mgpatoloy kp gumawa ng tutorial vedio marami . My tanong lng ako regarding circuit breaker .for example un outdoor breaker k is 30 amper..kailangan b un main breaker k s indoor ay 30 dn
Yes sir...same amps po dapat
Sir wala po bang tutorial ng cable tray fabrication, like 90° bend?
Sir tanong lng..positive at negative saan po jn ung hot wire po..slamat sa if masagot po..
Positive and negative sa DC lang po un sir.....
pag AC walang polarity yun brad. Sa ibang bansa may color coding ang hot wire at return wire, pero ang purpose nun is para madali makita kapag may maintenance hindi sya polarity.
Sir ano ba ang dapat gamitin na extension wire and outlet para sa inverter welding machine na 300A? Kailangan paba ito gamitan ng magnetic Contactor? Thankz...
Ilang amps po sa input ng primary sir?
Rated input capacity (kVA) 3.8 kVA Sir, thanks...
Gumamit kn ng 50amps s welding machine at number 5.5 n wire
As per pec every circuit for lighting is 10pcs 100watts
Mam pwd po ba malaman kung anong article po yan sa PEC para madouble check ko po..
13 lights per circuit 8 outlet per circuit naman sa power!
Ser tanong kulang 100 ilaw at30 bentelador anong laki ng Generator ang dapat gamitin ilang AMP
ilang watts yong efan mo sir?
Sir pag sinaksak Ang 10 amper sa 10 amper mag aapair Kang ba yun
Di na kailangan kwentahin pa yan kasi alam mo na ang capacity ng switch Ng i follow nyo ang PEC standard .kHit kayanin pa nya mataas na ampere ang pagbabasehan pa rin ang standard dahil iyon amg pina ka safe
Bro dpnde pa kac yan sa haba ng wire n ggamitin, ,,pero galing saludo aq sau ,
Yes sir... actually daming factor pa ang dapat iconsider..
Sir San kinuha yung 0.8? Safety factor satin SA pinas standard?
Hello po sna ma notice po ask ko sna ano po ba required amperes kpg s ref po sna po masagot thnk you po
Master may video kba .. ng 3 ilaw at tatlong outlet.. 3 way swutch po.. tas yung outlet para sa aircon.. thanks..god bless
Kung katulad po sa sinabi nyo sir wala po pero may single2 lng tayo
Boss paturo naman kung pano malalaman kung 1ton ang aircon. God bless po!
Cg po sir...
hahahaha ikunsulta pa daw ni Sir sa PEC.. 1 Ton A/C is 12000 BTU..,,,,12000 BTU is 4.7172 - HorsePower-Hour
Naka base Ang aircon sa HP Hindi ton..
yun safety factor po ba at power factor ay pareho ty po
Magkaiba po sir
Sir how about the amprerage? Wattage lang po kinonsider nyo,?
sir wattage divide voltage is amperage
Sir meron kami ng 500 watts mercury lamp kaya ba ito sir sa isang switch
Ok idol..salamat
Salamat din po
Sir tanung lang...yung multply by 230 saan mo nakuha yan..tanx
Ang nominal value sir ng 220 is 230v according to the code book sir
Sir wala po ba kayong video ng paliwanag ng transformer
Wala pa po sir....soon po sir...
@@junauxtv okay sir salamat po
Sir dpat ang ituro mo under PEC para safe at standard.wl sa PEC tinuturo mo.
Totoo, parang nanghuhula lang eh. Sinabi na ngang 16A ang kaya ng switch hanggang 50 pcs lang daw na LED ang kaya.
Please always comply with the Latest Philippine Electrical Code of the Philippines. Thank you.
Noted po sir... salamat po
@@junauxtv You're Welcome po sir. Tuloy nyo lang po yan maganda yan marami ka po matutulongan. Keep up the good work.
Me as an e&i technician hindi q inaadvice na ganun k.rami ang ilaw na gagamitin...tama ka po sir lung mg.babase tayo sa specification ng isang device kung ilan ang maximum capacity nya may point ka don kase tama yung computation mo sir...pero yung point q...mgmamatter pa rin ang haba ng cable na ggamitin sa isang circuit sir..isa pa during maintenance dagdag trabaho kase halimbawa ngkaproblema ang isang circuit ng ilaw na may 15 lighting fixture ibig sabihin imbis na m.bilis ang troubleshooting, sa dami ng ilaw na kinabit hustle pa..another thing na nakita q kung ganyan karami ay kung halimbawa ang switch ang bumigay...edi lahat ilaw m.wawalan ng supply...tsaka sir alam q gusto mo lng ibahagi ang k.alaman mo pero pwede bang respetohin mo nmn ibang electrician?..wag mong sabihin na d lahat ng electrician alam to..ampangit pakinggan sir..ang labas eh ikaw na ang magaling...baka maraming electrician na mas may alam pa sayo sir m.papahiya ka lng...hindi mo ako basher sir gusto q lng liwanagin na hindi lahat ng nk.k.panood nito mga baguhang electrician...yung ibang nk.k.panood nito matagal na sa larangan ng kuryente kaya sana wag ganyang mga caption....salamat sir..asallamu alaikom
Tnx additional info sir at bahagi ng idea nyo about caption ko sa video na ito
Tama po kau jan sir... lalo na sa switch.. not advisable na lagyan yan ng pagkadami daming lights...
My standard procedure parin pong sinusunod mga electricians.... saka po ung caption nio tibay, hahaha..
Pero salamat na din po sa info..
Tama k po sir para lumalabas s caption nya sya lng ang may alam at magling eh halata nman n may binabasa kapg nagpaliwanag n bubulol p
sir tanung kulang..anu ba mganda gamitin na circuit breaker sa bahay..
Schneider/GE mas maganda kung bolt on sir
GE, kung gusto mo mas mtibay at good quality Schnieder kaso Miniature yun. Ang maliit
Mitsubishi earth leakage
Sir jun aux saan galing ung 230 or given ba un #
Nominal voltage po sir sa 220vac...pag mga computation as per PEC 230v ang gagamitin natin sir
Sir anong breaker ang kailangan sa 11 cubic meter na freezer at anong wire guage? Thanks
may watts po ba jan or amps..yan po pagbabasihan natin sir
30 ampers gamitin mo
Bossing, ano ba ang dapat gawin kong ang outlet ay umaabot sa 250v?
sir pa help naman po. Possible ba na maglagay ng GROUND sa existing outlet? Thanks.
naka 3 prong na ba outlet mo sir at may grounding na po ba?
@@junauxtv Salamat po sa reply. 2 prong pa din po sya.. at wala ding grounding. Any suggestions po? Thanks ulet.
Kahit wla n ok lng un
Pwede po bang isaksak ref at freezer sa two gang outlet?
Pede pero delikado.pra safe ibukod mo isa isang breaker tig 30 ampers solo lng.isang outlet s isang breaker
Sir Jun aux paano computin aircon 1 hours power kc 2 compute MO s aircon
Sir gud pm po halimbawa po naglilinya ka po na nakabukas po yung breaker sa main switch po pwd mo po bang hawakan ang isang linya may kuryente po ba yun at kung isang linya ay nakatugtong na po sa isang linya po i mean line 1 sa line 1 yung line 2 idudugtong mo pa lng gamit ang kamay makukuryente ka po ba salamat po sa Dios gandang gabi
Hi mam... technically meron pong way but kahit sinu pong license Electrical practitioner hindi po namin nirerecommend yan at hindi din po namin pinapractice...mas maganda po na safe po tayo palage...
@@junauxtv sir salamat po sa Dios pwd mo po ba ituro kung paano po bumasa o gumamit ng tester po salamat po