Ilang Ilaw sa 15A na Circuit Breaker?
Вставка
- Опубліковано 18 жов 2024
- Welcome to Jun Aux TV if you enjoy watching this video don't forget to subscribe, like and hit notification bell thank you!
Also visit my FB pages and group:
JB Handyman Services
✓If you’re looking for the right person to fix the problem your facing in your home you can find it here, License Electrical Practitioner is available here, visit us
Jun Aux TV
✓all about Electrical installation and Electrical devices reviews and safety awareness on Electrical
JB Online Shop
✓you can buy product such as Electrical devices mostly on industrial devices
www.facebook.c...
Electrician For Hire
✓group of Electrician looking for a job and giving and taking ideas in one another
JBLyricsVideo
✓its all about lyric video on popular music now a days
Thanks for Watching hope you enjoy. God bless
mas matututo talaga tayo sa youtube kesa sa school... kahit electrical engineering grad ako...at nag tesda din as building wiring electrician... na ge gets ko mga explanations... maliwanag ang explanations basta ung nakikinig at nonood may knowledge din, sa electricals
tama ka sir.. pang deped kasi turo sa school....hahah
Sir thanks for your explanation. Mas maganda sir na nag re- refer ka sa Philippines electrical code. Kasi nandoon Ang standard allowable lamp load per lighting circuit.
Noted po sir...tnx po
Sir ok yong tutorial nio,na explaine mo tlga ..Tanong ko lg pwedi ba ung outlet sa 15 ampheres at isasaksak ay refregerator, pki gawa nman sir ng tutorial video pra dito..Tnx..
Pag outlet sir... minimum po tayo ng 20amps
@@junauxtv ...salamat sir.
Salamat ulit. Nag aaral pa lang ako mag wiring. Laking tulong nito
Good video sir. Tanong ko lng po kung 2.0mm2 ang mga ggmitin na wire para sa mga ito:
- Lighting to breaker
- Lighting to switch
- Switch to breaker
2.5mm
New subscriber here!
ask ko na po sa isang simpleng bahay magkano po sinisingil ninyo sa isang buong bahay o kada butas magkano basic price ngayon salamat po..
Additional Info: Please consider also the voltage drop. Kindly refer to PEC or NEC how many percent allowed in one branch circuit. God Bless you always Sir. Salamat sa knowledge ibinabahagi nyo.
Sir thank you po...sir baka alam nyo po kung anong article sa PEC makikita yan?
FDAS at CCTV nman po
@UCI2SCzKhv290MI9GeXQYlfw real electrician din naman ako sir...4 years grad electrical course, RME, EIM NCII, BES NCII
NEC ibigay ko sayo SIr. PEC wala ako hawak, nasa labas kasi ako Sir. NEC: Branch Ckt.=210-19(a) FPN No. 4, Feeders=215-2(d) FPN No. 2. Ipagpatuloy mo lang Sir, Maraming akong natutunan sa'yo Sir. Give and take lang Sir.
Sir!! Paano nman po yung sa voltage drop po?
Good day sir... Maitanong ko lng 15A good 4 bulbs lng ba? Sa Ngayon kc sir may nka tap na 3 ceiling fan sa 15A na breaker ko at 10 bulbs Ang gmit ko Ngayon.. sana po sir mpansin nyo po
Sir sa province po ay line to ground ang kuryente...1 black wire at 1 aluminum wire coming from the pole...yung aluminum wire pag connect sa breaker box dadaan pa ba sa cb...or yung black wire lng?
Need mo talaga idaan sa breaker yan sir i mean ung dalawang wire...like for example sa breaker mo outdoor tapos Pagdating sa loob ng bahay pwd ung hot wire ang dadaan ng breaker
Sir . Good day. Sir pwde po ba ang 2200 watts na appliances sa 20 ampere at 240 volts na breaker?
Boss kung aircon pwedi ba dalawang aircon sa isang breaker?or mag additional breaker talaga?salamat
Sir ask ko lang po, pag po ba sa 3 storey building like school building, isa lang panel board or bawat floor may kanya kanya?
Sir how about po yung Office Building na meron 30 to 40 outlets including Exhaust Fan? Ilan po ang pwede dapat sa 15A Breaker? Salamat sa sagot.
Idol,16 branches Ang panel board na gamin,Anong dapat ilagay na main breaker?walong 20amp.at walong 15amp.
Kuya jun good morning:))
Meron lang akong ilan katanungan.Meron po akong napanood na isang video na ang 15 ampere 10 bulb lang ang magagamit kase sabi sa video ang 1bulb is 1ampere hindi sya gumamit ng 80percent or safety factor..Sana po masagot nyo yung katanungan ko salamat po godbless!!!
Boss Jun hindi ba maxado namang conservative na minultiply na nga naten sa 80% ung capacity ng CB, tapos ititreat pa nateng 100W na ung kada isang bumbilya.
May mga bulb kasi sir na hanggang 100watts kaya asume na natin...d nmn po kasi tayo sigurado na hindi nila papalitan ng bulb na mataas ang wattage..
@@junauxtv Ako din napaisip, well explained sir.
Master pa request naman po. Pa explain po ng line to line connectiom sa bahay paano po ang takbo ng kuryente? Salamat master
Soon po sir...tnx po
maganda topic din yan line to line tsaka line to ground... abangan ko na lng yan... ke master
Hindi po ba masyadong mataas ang assumption ninyo na 100w /1500 lumen ordinary bulb or LED equivalent na 25w. Kasi po halos ginagamit madalas sa ordinaryong bahay na ordinary bulb ay 60w /900 lumen or LED equivalent 15w. Low power consumption low amps thinner wire size less expense or budget. Hindi po ba?
Yes sir but we need to comply with Philippine Electrical Code for our safety
Ganyan po kasi pag sa design analysis. Sa NEC, 100VA po ang rule of thumb ng bawat lighting outlet.
Pero pag specified po ang L.O. sa PEC 2.10.2.3, susundin naman po ang area method para maiapply ang specified rating per L.O.
Salamat sa mga naituro mo boss may napulot naman akong kaalam sayo.
Salamat din po...
27.6 mag 30 amprs. Ka
nice vid. ano po bng wire gamit sa ilaw at outlet? solid o stranded? thnk u
Pwd sir solid or stranded pero mostly ginagamit is stranded
salamat boss jun. npka informative ng channel nyo. more power
pwede mo gamitin ang solid or stranded pero may advantages ang bawat isa.
tnk u sir. ano po b advantage ng stranded over solid and vice versa
Gud day sir. Sir ano amp pwd s mga ilaw n led. 9watts lng Ang ilaw 12 PCs lng Po eto bale 118 watts lng xa.
Sir pwede b pang extension yng royal cord no # 16 dublehin pra lumaki wire bale Tig 2 wire per line
Baka hindi na papasok sa outlet mo sir ang wire
Ok sir ty
idol pa advice naman ako plan kung magkabit nf breaker sa bahay ko ang outlet ko ay tatlong tig 2 gang at switch ko ay isang 3gang at 1gang, ang gamit k sa bhay ay ref,electric fan plantsa, ano kyang bagay na circuit breaker pra dto ,
Good video sir. Tanong ko lng po kung 2.0mm2 ang mga ggmitin na wire para sa mga ito:
- Lighting bulb to circuit breaker
- Lighting bulb to switch
- Switch to circuit breaker
boss pede kuba palitan ng 30 or 20 amp yung 15 amp na ginagamit ko sa aircon? dudugtungan ko sana ng 2gang outlet kasi boss, thx sa sagot.
Sana masagot. Tanong po sir. Pwede po ba yung yung 2 gang gawing 1 switch at 1 outlet. Pero sa switch po magmumula hotwire ng outlet. Gagamitin ko po sana para saksakan ng ref. Imbes bunutin yung saksakan twing walang kuryente, switch off nalang.
hello po pwd po ba size 8 thhn wire sa 60a circuit breaker po? dba 48a ung max load nya po?
Sir pano po pag main breaker ko e 100 amp tapos ang inverter welding machine ko ay 300 amp...kailangan ba dko pwede ilampas sa 100 amp ang adjustment ng welding machine ko?
thanks master, sa sample niyo is 100 watts ginamit niyo pwedeng 27 bulbs eh ung 50 watts or below gagamitin tama ba na pwede ako gumamit ng 50 bulbs basta below 50 watts or below ang ilaw ko? salamat
para sa dagdag kaalaman mag jun aux tv👍👍👍
sir ok lng lng ba magamit ko ung 25 na ilaw isang breaker lng 50 watts bawat isa. #14 ung wire. kya ba kaymhit sabay lahat gamitin
Maraming salamat sa kaalaman sir. Dami ko natutunan sayo
Salamat din po sir
Ask lng boss bkit 100watts tlga computation ntin pra po ba sa sicurity?ksi kalimitan ng bulb light ngaun 3,4,7,9 etc.watts lng khit mg 50watts pa per bulb mukhang safe pa dba?pa correct po ako slmat boss more power!
Di kasi natin sir alam kung ilang watts ang ikakabit ng may ari ng bahay kung mapundi na ung nainstall natin kaya mas maganda if ang computation natin nasa taas na
Sir I would like to ask lang if ilang Computer Units ang pwede sa 20 ampere na sub breaker.??
Need to know po talaga..salamat!
kunin mo ang wattage ng powersupply ng cpu and wattage ng monitor. e add mo yan ang total wattage per pc.
add mo lang ang ipang pc. baka magkaiba ang wattage per unit.
@@screwfaceworld thanks po
@@mikoxx1
20A x 80% = 16Ampere
(80% effective current usage
20% wasted due to heating of conductor)
P = watts
I = Current(A)
V = Volts (V)
Formula
P = IV
P = 16A x 220V
P = 3,520 Watts . this is the total wattage na ma accomodate ng 20A sub breaker. wag mo lang e sagad .
sample : Pc 1 = 100W . Pc 2 = 150W
total = 250W .
3,520W - 250W = 3,270W (ito nalang sobra)
Kung Chint MCB ang gagamitin, sa pagkakaalam ko walang 15a mcb .. Pwede ba yung 16a nila ??
BossJun, Bago lang po ako dito sa Channel mo may Request po sana ako pano mag Install ng FACP or Fire Alarm Control Panel na nakakabit na ang SMOKE DETECTOR AT HEAT DETECTOR
Pag nakabili na po tayo ng unit sir...mahal din po kasi sir...pag iponan pa
@@junauxtv Sege po Bossjun Andami ko pong natutunan sa channel mo , maraming salamat po.
Ang fire alarm ay 2 klase. Isang conventional at isang addressable. If conventional lang ang unit (depending on the no. of zones), 2 wire lang ito with 30 max devices per zone and end of line resistor with 1 or 2 alarm bell lines.
May alam ka sir bilihan ng fire alarm?pangdemo lng po sana
bakit gusto mo matutunan ang FACP, bibigyan kita ng idea kahit paano..alamin mo muna dapat kung anong FACP siya may 2 types kasi yan 1. conventional, 2 Addressable aling sa dalawa ang gusto mo matutunan.. + - polarity lang titingan mo diyan dahil ang bawat base ng detectors heat o smoke ay may polarity + - . may zones ang conventional at address naman sa addressable.
Ask ko lang po sir 2 bulb ng heat lamp 500watts ilang amper ng breker ang gagamitin salamat sir sana makareply po kayo sir
Gano kalayo and distances ng mga ilaw at saksakan yun standard ng PEC ? Distance of Pannel board and Fire alarm Cotrol Pannel to the ground floor ? 🤔
Visit mo sir jun aux tv fbpage natin may mga post ako don sa standard height... important guildlines ang post ko sir
sir ano pa ba ang fb page mo sir?
may requirement ang PEC pag dating sa voltage drop 3% up to 5%... pero since ilaw at saksakan lang naman gagamitin mo safe to use up to 25mts.. pero tandaan natin na may ampacity rating ang #14AWG at #12AWG kung ilang ilaw at saksakan ang pwede sa mga size na yan.
sir jb, khit po yung homerun number 14awg yung wire?
Master, anong fit n wire # or size of wire ang compatible at safe s bawat breaker amp's? Slamat s sagot master.
Sir visit and like my fbpage may mga important guildlines tayo kasama na ang ampere rating na sinasabi mo sir....tnx po
Sir, tanong lng.. ano gauge ng wire n ginagamit s hiuse wiring pra s ilaw at s appliances..
Ilaw 15amps no.14 wire
Outlet 20amps no.12 wire
Stranded wire THHN Philflex or Phelps dodge
sir, saan nanggaling ang 230V? newbie lang po.
Boss pwede po ba mag request . How to breaker tripping adjustment setting
sir baka pwede po magrequest kung paanu ginagawa yung wiring ng 220v covert to 110v salamat
Gumamit po kayo ng transformer. Input 220v yong output naman 110v
Magagawa nyo po yan if line to line po kayo din provided ni power provider nyo neutral gaya po dito samin.
para di mahirapan sa 15A hangang 800w ang require or 8pcs na 100w,,.
kung mababa watrs lng ang ggmitin mo i devide mo nlng.
100w 8pcs
kung 50w 16pcs
kung 25w 32pcs
Tanong lang po sir,sa amin kasi single circuit breaker lng na 60A..gusto nmin mag add ng refrigerator..anu po kaya ang pweding circuit breaker at saan ito ikakabit?
Ano ano po mga load mo sir...name atleast 3 na matataas na load
okay lang ba sir na gamitin ang 20 amp na circuit breaker sa 25 pcs na 100w na lights ?
boss same computation din ba sa appliances? tnx
Master pwdi poh bang #14 flat solid wire ang gamitin sa lahat nang breaker ampers? Tnx poh🙂
Sa ilaw lng yan pwd sir...15 amps na Circuit Breaker
@@junauxtv master ano Naman sa pataas na amperahi? exsample 30 amps at 60 amps anong size ng wire gagamitin?🙂
@@sniperelite3348 30AT is for 5.5mm2 wire, and 60AT is for 14mm2 na wire..
Hello po pwede po ba yan kabitan pa ng 1set na outlet salamat
Sir balak ko po sanang lagyan ng dalawang breaker yung main breaker namin kase fuse type pa po, makaluma, lalagay po sana ako hiwalay na breaker para ilaw at outlet, ilang amp po required para sa ilaw at pang outlet at anong wire po maganda gamitin.
Ilaw 15amps no.14 wire
Outlet 20amps no.12 wire
Stranded wire sir THHN Philflex or Phelps dodge sir
Salamat sir ❤
Gud am sir...sa ilaw ano po size ng wire na dapar gagamit?at pag outlet ano din po
Ilaw either 2.0mm 15amps cb
3.5mm 20amps cb
Outlet 3.5mm 20amps cb
sir new subs. 6pcs po yung ilaw ko sa bahay, 15A po yung main breaker ko, ilang outlet po ang pede ko install? tnks sa sagot.
Boss ..anu po wire na gagamitin sa 15a na breaker ..ty
2.0mm² or #14awg sir
Sir dalawang breaker po akin uki lang ba yon iba breaker sa appliance iba din sa mga ilaw
sir tanong ko lang, gusto ko sana pag praktisan yung 3 ilaw na pang flashlight ang laki with 1 switch yung tatluhan.. uubra ba ito kung hindi muna ako gagamit ng breaker imbes na breaker rekta muna isasaksak sa outlet bilang power source ng 3 ilaw with switch... practice lang muna
Pwd nmn sir pero mas maganda if may breaker po kayo incase mgkaproblema tapos hindi magtrip mapatay mo agad sa breaker
@@junauxtv siguro gagamit nalang muna po ako ng battery imbes na kuryente... thanks sa idea sir
@@djangogamino5918 pwd din po sir...
Bukod sa 27 bulb sir,kasama na din ba mga outlet or mga saksakan?
Bukod po sir ang para sa outlet
@@junauxtv another breaker para sa outlet tama po ba?
@@marlonforonda7264 yes sir....
@@junauxtv kung 20amp sa mga bulb at 20amp din sa mga outlet gagamitin is 3.5mm na wire tama po ba yun sir..wala po bang problema dun?😊
@@marlonforonda7264 yes sir tama po yan...ang mahalaga tugma wire size at cb amps
pag 6watt e di mas maraming ilaw ang kya,460 lights po?
Saan po ba kalimitan nilalagay ang breaker sa taas ba ng lababo
Boss yung breaker namin sa bahay 15 amp lng. Kaya ba 6 na ilaw at 5 outlet?
Boss, paturo nman paano Yung pagbili sa tamang sukat Ng copper wire sa bawat breaker..
Jun Aux TV din po name ng fbpage natin sir...nakapost ung ampere rating natin sir..
Sir ung 2760w hindi naba i convert yan sa .8??
Paano pag extension wire naman po?
New friend here👍
magkaiba po ba ang CB ng ilaw at outlet??
idol yung chandelier namin na maraming ilaw consider as isang ilang lang ba yan? sana may sagot po kayo
Dba sa incandescent bulb ang computation neto...so dahil kadalasan na ginagamit ngayon ay LED so talagang marami nang bulb magagamit sa 15A dba?
Kahit LED na 3 watts sir consider as 100 watts pa din sa computation
@@junauxtv bakit mo icoconsider na 100watts yung 3watts eh anglayo ng deperensya?
@@yuniktv for safety porpuses po sir...
100 VA is the standard unit for calculation for lighting as per PEC and NEC.
@@yuniktv sir yan po ang nka lagay sa pec code .yan ay hnd dpt bguhin , 100 va pra sa lighting 180va para sa outlet yan ay estimate purposes only.
Sir ano po ba ang magandang brand ng breaker para sa bahay at ilang amperes ang kailangan sa ngayon po kasi ang main switch namin sa bahay 30 amperes yung luma pang modelo na fuse type ok lang po ba yun meron po kaming air con wimdow type 1hp. Meron po syang sariling breaker (koten brand 60amp.)
Ung 60amps mo na breaker sir anong size ng wire po?
GE sir maganda sir...
Yung wire ng air con columbia wire 1.6 mm 2-c type 600 v.
@@ricardocoronado9794 ang liit po ata ng wire sir...ilang horse power po ba aircon mo sir
Sorry sir .75 hp lang pala yung air con namin
Ask ko lng po,sa bahay po namin every each room gusto ko lagyan ng circuit breaker per room,eh 2 outlet including aircon at 1 ilaw at 4 pinlight lang bawat room..so ang lalagay ko sana circuit breaker is 30 ampere so 3 rooms at sala bale 120 yun so dapat ko b gamitin is 150 ampere sa main??at wire gamit ko sa outlet is number10 pra pede saksakan ng pang welding if magpapatrast ako and sa ilaw is number 14..pki correct if mali??
Ilang aircon sir?at ilang hp isa?
1 aircon each room dko pa alam bibilin ko aircon eh gusto ko sana yung sa wall type sya yung pahaba
@@chriscondesa6353 split type po sir
For sure
3pcs 20amps ACU
3pcs 20amps for 3 rooms ilaw outlet
Dapat po kasi sir hiwalay ang aircon
Thank you so much
consult license electrical practitioner like RME...mas safe kung paconsult sa knila para safe ang instalasyon ng eletrikal sa bahay niyo.
Bro tanong kulang my welding portable ako 200ampere so anong ampere na pwidi ko siya isak sak
Pwidi koba isak sak sa wire na1.25mm 300volt
Sir.saan nyo po nakuha ang 12A.pra maitindhan k po ng maayos.ktulad po nito.current 12A.saan po sya nanggaling.
80%sa 15amp daw
Sir Jun alin po ang mtipid...ung 12v 9w n bulb or ung 220v 9w n bulb? Salamat po.
Yung 12v po dc po yan yung 220v AC
Pano kung flourescent po hndi bulbs ang gnamit same pdn po ba?
depnde sa watts ng flourescent kung 100 eri edivide mo ng 100w.
Nice informative....but need practice explaining..
Tnx sir...
ilan pong ampere pwede na Cbraker sa portable Welding machine na 300 ampere.tnx po sa sagot.
may computation ang pag sige ng welding machine based sa kanyan duty cycle pero kung gusto mo madalian safe na gumamait ka ng 60AT na Molded Case Circuit Breaker or MCCB.
may computation yan ctaully based on welding machine rating plus duty cycle makikita rin yan sa PEC.. pero kung gusto mo kasagutan safe na na gumamit ka ng 60AT Molded Case Circuit Breaker o MCCB.
Boss sa isang convenice outlet isang saksan lang ba yan or 2 gang or 3gang?
2 gang po sir...
Maraming salamat sir, like subscribe and hit the notification bell, yn lang po ma isu2kli ku sa explanation nyu ty po
Enough na enough na po yan sir.... maraming salamat din po sir
sir,maytanong po aqo sa in,u ilang watts breaker,kung sampung bahay nakakabit sa breaker po
May tamang computation para jan sir....
@@junauxtv kac,ser ung kinabit namen,30,amp lang eh sumabog hindi kinaya,amp
@@jhaymalate4344 hindi po talaga kakayanin yan sir kung sampong bahay ba namn susupplyan...need mo ang total load sir bawat bahay para macompute mo ang main
para maging safe ang isang electrical installation may proper computation ng loads diyan based sa area ng bahay or based on actual loads. hindi basta2x na hulaan lang.
Wow may natunan ako .thnks boss npa subscribe tuloy ako sau
Salamat mam...hindi ka magsisisi mam na nagsubcribe po kayo..
Salamat po ng marami sa knowledge po
Boss yung electrician ko gusto nya 30amps CB para sa isang kwarto 1hp acu, flat tv, desktop computer tama ba yun? 3.5 mm wire size
Sa standard sir dalawang 20amps na breaker need mo jan sir...ung aircon may sariling breaker po
Hndi ba pwedeng isang 30 amps breaker boss isang acu lng nman ska dalawang outlet
@@christianbustillo56 isang 20 amps sir gamitin nyo..3.5mm na wire...kesa sa 30amps sir
Okey po
pero boss nailagay na po pano kaya yun? 30 amps breaker isang AC 1hp tas dalawang outlet kalinya niya.. okey lng Kaya??
Salamat Master 🙏
Salamat din po sir
assuming sir na 50 wattz ang gamitin bawat isang ilaw tama ba na 55 ang total na pede sa 15amps na cb natin?
Minimum po kayo sir ng 100watts kada isa....
pag sinabi mong max ibig sabihin sagad na....e bakit may for expansion ka pa? ang allowed mo 27 e di ilagay mo kung ilan ang kailangan at pag lampas na ng 27 saka mo na problemahin mag lagay ng bagong breaker
Bakit 15A x 230V eh ang LL voltage system mo ay 115V-115V. Ang dapat dyan ay 15A x 115V ksi sa isang breaker lang ang 115V.Saka mo inapply ang
P=VI where P=total load
V=230V I= Total current
Kung LN (230v-0) dito mo i apply ang 15A x230V.
Ang pagkaalam k po sir khit line to line o line to neutral basta kinlabasan nya umabot ng 220 -230 pasok po sa computation nya.
I think need mo rin paliwanag kung saan at paano nakuha ang 80% para maintindihan nila.
Sa ibang video ko sir naka specify kung ano ang .8
sir..paano kung led ligths ang gamitin at 9watts ang isa....ilang ilaw sa 15A?
Consider as 100watts pa din po sir
@@junauxtv ibig sabihin po ba sir kahit 3 or 9w ang bulb ay econsider parin sa 100w? Eh di sana itong mga gumagawa ng bulb ay lagyan nila ng 1w up to 100w diba po? Ibig sabihin mga factory ng bulb ang may mali? Tanong lang po .
Boss Anu size na wire gamitin sa 15a and 20 ampers??
May table tayo jan sir...nasa fbpage natin Jun Aux TV din po
@@junauxtv boss diba Ang service entrance gamit ay #8 bakit 14 Ang gamitin??
@@allinbone4510 depende sa main breaker mo sir....kung 20amps 3.5mm/#12
Allin Bone #14mm bro pag sa ilaw at #12 mm pàra sa mga outlet.
@@rodelcabase7917 #14awg at #12awg sir hindi mm
What if sir pag 20A or higher?? ganon din po ba?? 80% din po ba???
computin molang ang wattage ng bawat ilaw gagamitin mo' tapos WATTS divide VOLT= AMPERES
huh pano ?
Baka total watts divide by 230v po
Ilang watts kada isang bulb sir???
Idol my nbibili bng libro pra sa gntong electrical knowledge?slamat
Opo sir...i recommend PEC sir..jan lahat ng standard
@@junauxtv saan po makakabili sit ng PEC book?at anong edition ang swak
@@charlsnorveescrupolo1182 IIEE sir...mas maganda sir if latest edition na..sakin kase 2017
ilan ilaw boss ang ilalagay sa isang room na 4x3 meter?? yung estimated lng sa isang room
Iba ka talaga idol n Kita dami q tatutuhan sayo
Salamat po sir
Sama nyu na Rin po master Kong anu wire gagamitin .. thank you ..
Sir, kung halimbawa po, 110 lng ang suply nyo sa bahay. Pano nyo poba e convert sa 220?
Sana mabasa nyo po to sir. Salamat po. ☺️
Step up transformer sir
Pwedi kubang e jumper Yung hot wire nya sa double breaker pra magiging 220 S'ya sir?
Gagana puba Yun?
Hindi po sir kasi isang linya lang un....
PG line to line ka pwde step up transformer .110vac to 220vac .PG DC nman 12vdc to 220vac inverter transformer Naman .
Nice video po, salamat
Bakit po ba 100 watts? Kung 45W ang lights namin? ok lang po ba yon?
45W nalang din i divide ko?
salamat sa info.boss pashout out nman jn hehe Godbless=)
Salamat din sir...cg sir...
Ganda boss
Ask ko lang po sir..ano po requirements para maging RME katulad niyo po sir??sana magreply..hehehe
5 years experience po if high school grad
Salamat po