  • Step by step tutorial on converting old 8' fixtures with single pin FA8 tombstones. Addresses two potential problems - what to do if your tombstones are non-shunted AND how to solve the major problem of LED tubes with short pins that don't make electrical contact in a standard fixture.

КОМЕНТАРІ • 4

  • @stevebrown5543
    @stevebrown5543 4 роки тому +1

    Couldn't hear a lot of what was being said but thanks for the video.

  • @177BCardinal
    @177BCardinal 4 роки тому

    So, you didn't wind up with line(black) on one end and neutral(white) on the other, right? Looks like you have both on each end.

    • @normm1649
      @normm1649 4 роки тому

      I agree, it appears you have the power end (black) going to both ends on the same tube? Can you explain

    • @xsiv5speed
      @xsiv5speed 11 місяців тому

      I didn’t see that either. He mentioned that he’d want hot line on one end (like tying your black source wire to all the black & white wires on the 2 non-spring loaded tombstone side) and neutral on the other end (tying your white neutral source wire to both red and blue wires on the 2 spring-loaded tombstone side), but that didn’t happen. Instead, he tied the black wire to the red wire on the spring-loaded tombstone side and the white wire to the blue wire on the spring-loaded tombstone side. So the 2 bulbs are wired in series?