PLC based Automatic Door Opening and Closing System

Поділитися
Вставка
  • Опубліковано 2 лис 2024

КОМЕНТАРІ • 18

  • @InstrumentationTools
    @InstrumentationTools  Рік тому +2

    => Next Video HMI Design and Simulation of Automatic Door Open Close
    ua-cam.com/video/p5rsrpAM5Q8/v-deo.html
    => PLC HMI Courses
    automationcommunity.com/

    • @puranmal32
      @puranmal32 Рік тому

      Sir can u give training of plc HMI and scada

  • @seanakiiki7670
    @seanakiiki7670 2 місяці тому

    Thxu for the great knowledge, am learning engineer, I enjoy automation, and ur tutorials

  • @dilipsharma1568
    @dilipsharma1568 Рік тому

    Very good sir. I also created this project by himself for practice before u uploadedwith extra feature with auto manual and manual open close button dunction

  • @arvinmistry9744
    @arvinmistry9744 Рік тому +2

    you are very good thank you i learn some logic

  • @ShivaKumar-pk7zj
    @ShivaKumar-pk7zj Рік тому +1

    EXCELENT video very good.
    Thank you.

  • @sonurock7625
    @sonurock7625 Рік тому +1

    Very good session sir

  • @puranmal32
    @puranmal32 Рік тому +1

    Very interesting and helpful video

  • @masumahmed2142
    @masumahmed2142 Рік тому +1

    very goooooooood

  • @vladimirdzodzak5589
    @vladimirdzodzak5589 Рік тому +1

    Ok Is good, but isnt good use to Y out as paraller kontakt. Is Ideally changed for internal Merker.

  • @mohantyagi5740
    @mohantyagi5740 Рік тому +2

    Similar programme being employed for Metro trains.

  • @kvong615
    @kvong615 Рік тому

    Thank you great video

  • @karthikeya6508
    @karthikeya6508 Рік тому +1

    Thanks 👍

  • @asifmallik3742
    @asifmallik3742 5 місяців тому

    why u used T0 , you should explain addressing of T0

  • @payalsharma6199
    @payalsharma6199 Рік тому

    Sir can u explain why did u take x1 and x3 as normally close and in series as when x0 is pressed they will still in close comdition

    • @mumbles1justin
      @mumbles1justin Рік тому

      X1 and X3 in rung 1 are “software interlocks” to prevent forward and reverse from being energized at the same time. In a real application, you would use a software interlock along with a mechanical interlock and an electrical interlock to provide three stages of safety to prevent short circuit when using a reversing contactor.
      But the example in this video is not actually usable as is on physical equipment only on software/ virtual based application.