Siglent SD3055 FW Update...and some Quirks

Поділитися
Вставка
  • Опубліковано 15 жов 2024
  • Please support my content creation by using my Amazon Store:
    astore.amazon.c...
    Or anything on Amazon:
    www.amazon.com/...
    ----------------------------- Click "Show more" ------------------------------------------
    In this video I chat about the Siglent SD3055 firmware updates:
    sdm305(V100R001B01D01P15R1) (ver 1.01.01.15R1) and sdm305(V100R001B01D01P15R2) (ver 1.01.01.15R1).
    These improve amongst other things:
    Increase the trigger / UI update speed.
    Add the diode threshold setting function.
    Fix a bug in temperature measurement.
    Quirks:
    The saving of the settings for next power on can take up to a minute. If the meter is powered off before then, the settings are not saved.
    The Filter feature used in DC measurements switches a large capacitor across the input which can unsettle the reading and change the 10 Mega Ohm input impedance while it charges.
    Siglent have committed to maintaining a change log for the firmware and updating their manual to explain the way some of their "features" work.
    ------------------------------------------------------------------------------------------------------
    My website and forum:- www.mjlorton.com
    Donations and contributions:- www.mjlorton.com
    My techie channel MJLorton - Solar Power and Electronic Measurement Equipment - / mjlorton
    My Techie Amazon Store: astore.amazon.c...
    My other channel VBlogMag - For almost any topic under the sun! - / vblogmag
    My VBlogMag Amazon Store: astore.amazon.c...
    ------------------------------------------------------------------------------------------------------
    ===================================================
    Video sponsor, Pass Ltd - their websites:
    At checkout use the discount / promotion code "mjlorton" for 5% off.
    www.tester.co.u... - Test Equipment and Test-meter suppliers and
    www.calibrate.c... - Calibration and service of test equipment
    ===================================================
    $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
    Bitcoin (BTC) Donations: 1K7PeF55e7ssE7W3WVCoa7c4j2PHzy6ASv
    $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
    **********************************************************************************
    Music clip from UA-cam Music Library - Phase Three by Huma-Huma
    **********************************************************************************

КОМЕНТАРІ • 30

  • @billybbob18
    @billybbob18 Рік тому +1

    With what you're describing with the slow state update . I think this may use EEPROM to store the settings. EEPROM has a limited write cycle at around a million write cycles depending on temperature conditions. Being conservative with that sort of memory was wise. And who changes settings then immediately turn it off anyway. They should tie the power button to the update storage function. obvious fix

  • @jeffsansoterra7743
    @jeffsansoterra7743 9 років тому

    Thanks Martin. It is good to see all the deep characterization of this meter and how Siglent has been responding with updates.

  • @g1fsh
    @g1fsh 9 років тому +1

    At least they seem to be listening Martin and trying to move forward. I love the big display on this meter and with the bugs ironed out and for this price I see a very nice meter in the future. It shows how much well deserved respect these people have for your opinion.

    • @mjlorton
      @mjlorton  9 років тому

      +Gary g1fsh Thanks for the post Gary.

  • @sdgelectronics
    @sdgelectronics 9 років тому +2

    Thanks for the video Martin!

  • @DeeegerD
    @DeeegerD 8 років тому +1

    The AC filter taking a few moments to settle makes perfect sense as it takes time to charge the capacitor... Don't see a problem. They could have used a smaller value cap but I'm sure it was selected for maximum voltages and current. Short of having an array of capacitors selected by range... Just get some patience ;)

    • @balbes1165
      @balbes1165 6 років тому

      They should have implemented a digital filter...

  • @tonycstech
    @tonycstech 2 роки тому

    In comparison to ANY handheld, this multimeter shows EXACTLY HALF the resistance value measured in circuit.
    Why is that ?

  • @PapasDino
    @PapasDino 9 років тому

    Rigol has been pretty good about their change logs and in some cases has been responsive to user feedback albeit taking some time to implement. Thanks for the update, nice to see that at least they're trying! 73 - Dino KL0S

  • @ElmerFuddGun
    @ElmerFuddGun 9 років тому +5

    What's the point of having a "soft" power button then? That's when they should be saving the settings. And even if you write to flash memory every single time it shouldn't be a problem if done right. You don't write to the exact same bytes but cycle through the entire flash or EEPROM (wear levelling). Heck, even if you do it "wrong" these chips have 100,000+ to 1,000,000+ write cycle endurances. I don't see how they would need much space to save every option on this meter.
    25+ years ago people were saving machine state information when it detected a hard power off and had to save the information before the charge on the PS caps died. Limited time and memory that didn't have the write cycle life that today's chips have yet it worked fine. This has a soft power button giving them all the time they want to write data before turning off. I'm confused why they are having a problem.
    What are they using the soft power button for then? They're not using it during shutdown and they are not using it to allow a quick start up (the screen should come on instantly) so what is the point? Just to have a high standby current and a pulsing LED?!

  • @rotlerin
    @rotlerin 9 років тому

    As a resident of Merseyside UK, I just love that t-shirt Martin. By the way, the video's cool too!

  • @leppie
    @leppie 9 років тому +1

    They should just save the settings when it soft power-off. But, does it have a way to do reset to defaults if something messed up?

  • @Coolkeys2009
    @Coolkeys2009 9 років тому +1

    Why didn't they write the firmware to save the settings just before it powers down? At least they're not wearing out the flash by saving every control change to it.

    • @mjlorton
      @mjlorton  9 років тому

      +Coolkeys2009 Valid point. I think they will be reading these comments and hopefully they can provide an answer.

  • @Eric4711
    @Eric4711 9 років тому +3

    Where can I get the new firmware? I don't see it on the Siglent site.

    • @mjlorton
      @mjlorton  9 років тому

      +Eric Hospel Hi Eric, I've asked Siglent to respond to your question. I know they gave it to me ahead of time so I think it should be up on their site soon..but I'll let them confirm.

    • @Eric4711
      @Eric4711 9 років тому

      +mjlorton Thanks Martin. I did get a version of the 15R2 firmware and the problem is fixed!

    • @mjlorton
      @mjlorton  9 років тому

      +Eric Hospel Brilliant, thanks for posting the feedback.

  • @SteelBlueVision
    @SteelBlueVision 9 років тому +1

    Oh, I see they have "fixed many other problems," according to their release notes. How informative!

  • @krish2nasa
    @krish2nasa 7 років тому

    Hi Martin, Did you try (Filter On and Off VDC test) with 10GΩ input impedance setting?

  • @mread42
    @mread42 9 років тому

    Martin, thanks for this, did you get a chance to asses the temperature measurements ? At the moment it is very inaccurate, ( reads about 4 C high ), using my sdm3055 with a k series thermocouple and 15R1 firmware, and I want to use it for some data logging.

    • @mjlorton
      @mjlorton  9 років тому

      +Martin Read Hi Martin, I did not take the time to properly assess the temperature issue but that's the key issue 15R2 is supposed to correct. If I have the time I'll role back my update and see if I have the same issue.

  • @SatyajitRoy2048
    @SatyajitRoy2048 9 років тому

    If it has got a large filter cap, then why is it overshooting when you disconnect and connect the input ? Where is it getting the extra voltage from ? Would you please consider tearing down the multi meter and show where exactly things happening which is causing this issue?

    • @CZDrMike
      @CZDrMike 9 років тому

      +Satyajit Roy I think that perhaps this overshoot has to do something with inductance of wires (just my theory)

    • @SatyajitRoy2048
      @SatyajitRoy2048 9 років тому

      +CZDrMike It could be, but as there is a series resistor it should not reach the highest value and then comes down to the actual. If you see the point when the probes are connected, then it starts by showing some milli volts (due to the incomplete integration period or something), but all of a sudden it goes 10.2436V and then settles down to the value. If it is due to inductance then its a bit difficult to charge the internal cap at that fast rate. I am assuming there is input series resistor which is certain for input protection mechanism. So the inductance factor might not work as per my views. Another point is, when the filter was disabled, then the overshoot didn't occur and the same inductance factor should have worked if it was meant to be the reason. Its interesting fact and I just cant find why its happening. However, if Martin is confident enough to let us see how the inside looks and the input sections are, then it will certainly reveal some of the interesting facts that we might be looking for :)

    • @mjlorton
      @mjlorton  9 років тому

      +Satyajit Roy That's certainly a consideration if I can grab the time. The Signal Path does a look inside in his review so you may spot something there in his video.

  • @Sainology
    @Sainology 9 років тому

    SD "M" not SD :P

  • @kaybhee6
    @kaybhee6 4 роки тому

    can u measire less than 1 milli ohm

  • @pratwurschtgulasch6662
    @pratwurschtgulasch6662 4 роки тому

    China #1

  • @kyoadam1593
    @kyoadam1593 3 роки тому

    You should hack it