How to check a 3 phase motor system

Поділитися
Вставка
  • Опубліковано 25 жов 2014
  • How to check a 3 phase motor system. This addresses the 3 phase motor in the system. Working through the system Motor to disconnect,overloads, contactor and fusses. Check us out at www.improvemain...
    I have a written version with simple print at www.improvemain...
    Troubleshooting a 3 phase motor system. I teach these methods and more on site on your equipment. George@improvemaintenance.com

КОМЕНТАРІ • 107

  • @kalelopaka
    @kalelopaka 5 років тому +12

    Done hundreds, this is the cleanest place I've ever seen, where's the water and hazardous chemicals, thats where I learned.

    • @electricalcontractor6944
      @electricalcontractor6944 3 роки тому

      If water and hazardous chemicals were part of an electrical system what you said you matter, but clearly that not the case, so what you stated is out of place. Electricity works the same way regardless, of where it is.

  • @fasteddie4107
    @fasteddie4107 3 роки тому +1

    Motor. Disconnect. Overload. Contactor. Fuses. Power.
    Check. Great video. Thanks for sharing this great information.

  • @mikekuknyo3329
    @mikekuknyo3329 2 роки тому +4

    Great video man. 10 yrs maintenamce...excellent suggestions...thank u

  • @mrdkoser
    @mrdkoser 7 років тому +11

    Professional and impressive use of theory. Great job!

  • @theotrotchie
    @theotrotchie 9 місяців тому +1

    Very well explained. I have slow it down and rewatch because a lot is covered in this vid.

  • @scrappydogfinance8434
    @scrappydogfinance8434 2 роки тому +18

    First test should be for voltage to ensure the circuit is actually de-energized. You should test your meter first on a known live circuit, then test on the de-energized circuit, then check on the known live circuit again to ensure your meter is actually working and not falsely indicating 0 voltage. Make sure your meter is properly rated for the Hazard category. usually 480vac 3phase motor circuits are considered CAT III. Minimum your meter should be rated for CAT IV 600V or CAT III 1000V even better. It should be certified by at least 2 independent labs like UL CSA TUV DVE for this CAT rating. Your test leads should have been inspected for any damage before use and your probe tips should have the least amount of metal exposed as possible. Ideally you clamp the COM lead to a ground away from the terminals to be tested first. and then use 1 hand to probe each terminal for voltage 1 at a time. This creates a greater distance between the two leads and lowers risk of accidental arc flash forming between the probe tips. After you are sure the circuit is de-energized then you can check phase to phase ohms on the motor windings and T leads.

    • @russelsprout2155
      @russelsprout2155 Рік тому +1

      If you don't know this you shouldn't be touching this equipment

    • @kevinb.3656
      @kevinb.3656 Рік тому

      Dude, no shit.

    • @adamkarsky473
      @adamkarsky473 8 місяців тому

      No shir huh, you copy paste that from Google 😂

  • @chandanshanaz3340
    @chandanshanaz3340 9 років тому +8

    very good testing, explaining in a simple way...

  • @wilecoyote2650
    @wilecoyote2650 8 років тому +8

    very good, correct PPE, this is the way it should be taught, very good

  • @michealplater9007
    @michealplater9007 2 роки тому +2

    I start at the other end, most faults are not at the motor, most of the time there is a protection trip, phase supply fault, overload or over temp.

  • @edgardoalfaro2307
    @edgardoalfaro2307 8 місяців тому

    Great information like the way you explain the topic

  • @MD-cd7em
    @MD-cd7em 6 років тому +3

    GREAT VIDEO!..YOU COVER BASICS AND GET TO THE POINT!!

  • @FaZeno5cope
    @FaZeno5cope 4 роки тому +1

    If you motor starts with the N.O start button and stops correctly, the control circuit is working properly and you can eliminate most of the steps shown in 30 seconds or less, then just check the power circuit and go from there. If your motor isn’t wanting to start, try manually picking it up with the seal in contact, If it starts, check start and stop button.

  • @Improvemaintenance
    @Improvemaintenance  9 років тому +17

    Our first how to

    • @user-tf2yy8ck6z
      @user-tf2yy8ck6z 7 років тому +1

      IMPROVEMAINTENANCE

    • @theslenderman4427
      @theslenderman4427 4 роки тому

      Hey bro if i i only have 3 cables and are ground red and black so my question is i want to install a little switch fuse box can i connected only using ground red and black

    • @theslenderman4427
      @theslenderman4427 4 роки тому

      Please let me know if you can

  • @tomascolz6375
    @tomascolz6375 5 років тому

    to check the motor it's better to use isolation tester. more than 0,5 MegaOhm between ground and phases. You check the cable also.

  • @firemusic82
    @firemusic82 9 років тому +6

    Very helpful. Thanks for this.

    • @Improvemaintenance
      @Improvemaintenance  9 років тому +2

      Thank You for the feedback. If you have any video requests go ahead and post in comments and we will try and get one together.

    • @firemusic82
      @firemusic82 9 років тому +4

      I do actually...a turn to turn short. Walk us through how to diagnose a turn to turn short in a 3 phase motor.

    • @user-wb3yp4bm1k
      @user-wb3yp4bm1k 7 років тому

      Edward James م

  • @nithyanandavenkatappa5416
    @nithyanandavenkatappa5416 2 роки тому

    Please *confirm and clarify* the following;
    Is it possible to connect 3-Phase twin motor control panel in series (*two Numbers*) - for the same/ only one pump set- motor ??

  • @sharifskijr.1257
    @sharifskijr.1257 24 дні тому

    Thank you so much

  • @shanemcdaniel1509
    @shanemcdaniel1509 5 років тому

    Watch this video more than once a grasp what he is saying also watch other videos on motor Controls and how to use a meter along with the danger of 3 phase 480/ 600 volts potential ...period

  • @nickledimez4012
    @nickledimez4012 3 роки тому

    Good video!

  • @simpliciocamirino2271
    @simpliciocamirino2271 2 роки тому

    thank you for that sharing sir.

  • @surendrakverma555
    @surendrakverma555 2 роки тому

    Very good. Thanks

  • @jeffgreen7897
    @jeffgreen7897 Рік тому

    You said “never throw a disconnect under load”. Sometimes you have to throw a disconnect under load if there’s an emergency.

  • @javierferrer4634
    @javierferrer4634 5 років тому

    Excellent video thank you!

  • @dougjones4987
    @dougjones4987 5 років тому

    Good explanation thanks

  • @elevatormechanic
    @elevatormechanic 7 років тому +2

    Why are you checking the motor at the disconnect? According to your print the normally open motor starter will be open. Kinda dumb

    • @quantumfoam140
      @quantumfoam140 6 років тому +5

      Rubberneck
      He mentioned in the video that sometimes a disconnect is installed near the motor to provide a convenient point to lock out for safety. In the schematic, this disconnect would appear after the overloads and before the motor.

  • @garethmurphy8235
    @garethmurphy8235 6 років тому +1

    What are you meaning by "control voltage"? Are u meaning 24VDC from the power supply?

  • @wmhvac-r2826
    @wmhvac-r2826 6 років тому

    Great video

  • @vincentsanchez9195
    @vincentsanchez9195 4 роки тому

    I understand the incomeing control voltage but what is the incomeing line voltage?

    • @vincentsanchez9195
      @vincentsanchez9195 4 роки тому

      I ment to ask what is the difference of income line voltage and income control voltage

    • @josephdupre770
      @josephdupre770 4 роки тому

      @@vincentsanchez9195 Line voltage is coming from the motor control center or substation. Control voltage is on the secondary side of the control transformer and has been stepped down to run the control circuit.

  • @caroldj.jenkins1843
    @caroldj.jenkins1843 4 роки тому

    Can some one explain what he means by incoming control voltage? Where is the incoming control voltage on the Contactor?

  • @robertosteen6621
    @robertosteen6621 5 років тому

    To check the motor shouldn't you determinate the motor or at least check the termination? I've had instances where the motor shoots good from the cabinet but you open the peckerhead and the phases are melted together. Obviously it would cause the breaker to trip but still from the disconnect you would see the same reading if the phases were not shorted.

    • @robertosteen6621
      @robertosteen6621 5 років тому

      Still an awesome video though!

    • @lanthonyperdum6430
      @lanthonyperdum6430 5 років тому

      Explain in more detail please...I’m thinking you are speaking of disconnecting the 3 power line leads and checking the motor leads in between windings is that correct ???

  • @juanleonardourena2883
    @juanleonardourena2883 3 роки тому

    Debiste seguir el tema que estaba hablando el dr nieves

  • @jasondangelo7064
    @jasondangelo7064 8 років тому +3

    why not check amperage???

  • @oscar27ization
    @oscar27ization 4 роки тому

    That disconnect didn’t need a supply side bonding jumper, since the enclosure didn’t seem to have eccentric knock outs

  • @mdmannankhan8358
    @mdmannankhan8358 7 років тому

    thanks

  • @tommygurule3496
    @tommygurule3496 8 років тому

    I have a question,how do you get a 3phase motor out of Lock Rotar Amp

    • @edcrowe6977
      @edcrowe6977 6 років тому +1

      if you remove the input voltage to the motor and make sure the motor shaft is free from any other mechanical sources , then the motor rotor should turn free within the motor housing. However, if the motor shaft fails to turn with no voltage applied , then the motor needs to be taken apart and inspected for bad end bell bearings and remove the motor rotor from the field and check for any damages there as well.

    • @edcrowe6977
      @edcrowe6977 6 років тому

      the locked rotor motor test is basically when the shaft of the motor is locked so that it cant move and then the rotor winding's are short circuited and checked that the lower frequency applied and reduced supply voltage matches the full load rated current of the motor

  • @Biginjapan85
    @Biginjapan85 9 років тому

    Hey, will checking the resistance between each phase of the motor not give the same resistance, as all of the windings are connected together in the motors terminal box?

    • @charliec8936
      @charliec8936 9 років тому +1

      +rory johnstone if you check resistance between each phase then yes the resistance should be the same as they are balanced. if they were different then they would be imbalanced and cause the motor to have a problem

    • @Biginjapan85
      @Biginjapan85 9 років тому +4

      +Charlotte Cottam As i understand the links for star/delta in the terminal box on the motor would have to be disconnected to properly test between phase to phase. As checking phase to phase with the links in will not show the fault due to the three phases being tied together in the terminal box.

    • @edcrowe6977
      @edcrowe6977 6 років тому

      In order to properly checking the motor winding resistance a megometer would be required as well. If any motor winding shows any resistance to ground. the motor field windings would have to be repaired then

    • @keyworksales6241
      @keyworksales6241 5 років тому

      Your meter may pick up small differences, however you should disconnect the motor from the circuit and test the insulation of the windings with a megger or meg-ohm-meter

  • @mauriciolopez9652
    @mauriciolopez9652 9 років тому +2

    Thank you, really helpull info. xD

  • @marktonydavis
    @marktonydavis 7 років тому +1

    Did I see a AB power flex 40 along with AB C09 DJ01?

  • @StealingLightLtd
    @StealingLightLtd 6 років тому

    Your written list is 404 error for the url.

  • @soviethammer
    @soviethammer 8 років тому

    Is the incoming control voltage 24VDC?

    • @youmah25
      @youmah25 8 років тому

      yes

    • @edcrowe6977
      @edcrowe6977 6 років тому

      sometimes the control voltage is 120 VAC if a step down transformer is used from the main power. This would all depend on the type of coil voltage used in the main contactor

  • @pbrown4
    @pbrown4 6 років тому

    do 3 phase motors not need an earth? what about neutral?

    • @quantumfoam140
      @quantumfoam140 6 років тому +1

      Peter Brown
      They do require an earth ground. In the United States it is usually the green wire as shown in the video when he shows the inside of the disconnect box.
      There is no neutral wire in a 3 phase motor. Each of the 3 phases is a hot wire.

    • @edcrowe6977
      @edcrowe6977 6 років тому +1

      no neutral wire is required only a green ground wire

  • @upakotv6457
    @upakotv6457 8 років тому +2

    i prove exellent circuit

  • @TheCommonSenseProfessor
    @TheCommonSenseProfessor 5 років тому

    Your written version and simple print link is bad.

  • @jenmagbojos624
    @jenmagbojos624 7 років тому +3

    i feel like inside the airplane

  • @hbknhry
    @hbknhry 5 років тому

    Very informative.

  • @travissmith383
    @travissmith383 3 місяці тому

    video could have been much better. Couldn't fully see what you were doing

  • @jeradLiberty
    @jeradLiberty 5 років тому

    Most 3 phase systems in the us are 480v???? Hu?

  • @tsikboiteevee6387
    @tsikboiteevee6387 4 роки тому

    interesting content keep it up! #HuertsGamz Channel

  • @charliewilley5004
    @charliewilley5004 6 років тому

    Your link to printable version doesn't work.

  • @akhileshkr03
    @akhileshkr03 8 років тому

    what is PPE ?pls explen it.

    • @soviethammer
      @soviethammer 8 років тому +1

      Personal Protective Equipment. (Safety Gear)

    • @akhileshkr03
      @akhileshkr03 8 років тому

      +Rand Mitch, thank yous sir

  • @rebelkhot3620
    @rebelkhot3620 6 років тому +1

    Make submarcible motor

  • @josephsmith6075
    @josephsmith6075 2 роки тому

    Good vid. But you talk too fast 😕

  • @3cressidas
    @3cressidas 6 років тому

    Your link to printable doesn't work.

  • @nathanmueller8994
    @nathanmueller8994 6 років тому

    No fuses & no transfer switch....

  • @mahamoodahammed3169
    @mahamoodahammed3169 7 років тому

    تمام صلى علي حبيبك محمد

  • @circuit-maker7971
    @circuit-maker7971 8 років тому +2

    Print link = 404

  • @bombebomb
    @bombebomb 5 років тому

    0:32 the truth

  • @hg2.
    @hg2. 6 років тому +6

    In an absolute sense, this is a good effort, but this is not a good "how to" video: the narration is too fast, it assumes extensive knowledge and experience by the listener. This is for experienced people only, and if they are already experienced, they don't need the instruction.
    Improvement can start by practicing the narration with no slurred/drop-offs toward the end of the sentence or idea. (Slurred end-of-sentence drop-offs alienate the listener because it shows an attitude that says "this stuff is so basic and elementary, and I'm bored with having to explain it to you.... "
    The narration should also have pauses between sentences and paragraphs, as opposed to the aggressive, pace here, which eventually sounds like an advertisement for the company, as opposed to an actual how-to video.

    • @dallas5374
      @dallas5374 5 років тому +2

      hg2 you should make a video showing everyone how it’s done....duh!!!!

    • @russelsprout2155
      @russelsprout2155 Рік тому

      How to videos shouldn't exist for electrical stuff. It's too dangerous. Only licenced electricians should be messing with this stuff

    • @hg2.
      @hg2. Рік тому

      @@russelsprout2155
      ^^ Union protectionist, right?

    • @hg2.
      @hg2. Рік тому

      @@dallas5374
      I'll look for a competitor that does it better.

    • @russelsprout2155
      @russelsprout2155 Рік тому

      @@hg2. well when someone you know dies because they're trying to be a jack of all trades then you'll understand

  • @rjsmith1630
    @rjsmith1630 6 місяців тому

    This is incorrect!! If your resistance phase to phase is low means you phase insolation is weaker and your about to phase out!

  • @gregorybeard5294
    @gregorybeard5294 8 років тому

    NEEDEED

  • @PBS-nm1uu
    @PBS-nm1uu 7 років тому +4

    to fast video is terrible

  • @koarivera9151
    @koarivera9151 4 роки тому +1

    Talks way too fast wow

  • @ronancahill2487
    @ronancahill2487 4 роки тому

    Slow down. You talk too fast. I could not keep up