Bulkhead Fitting Installation Instructions | Pressure Washing Business Equipment

Поділитися
Вставка
  • Опубліковано 9 лют 2025

КОМЕНТАРІ • 52

  • @chriss6837
    @chriss6837 11 місяців тому

    Thanks Doug.

  • @33brizzy
    @33brizzy 3 роки тому +1

    God bless you Doug, great videos!!! Thank you from Canada

  • @FrancoJeffrey
    @FrancoJeffrey 2 роки тому +1

    God be with you always in Jesus Christ name! Much love for all you do Doug! I hope to see you in the Kingdom of Jesus Christ!

  • @MrDozier23
    @MrDozier23 Рік тому +1

    Hey Doug, with the 1/2 inch barb what size hole saw did you use? Was it a 1/2 inch hole saw, in trying to bypass my pressure washer back to my tank?

    • @PressureCleaningSch
      @PressureCleaningSch  Рік тому

      If I remember correctly it was 1.25 same as 1&1/4" hole saw. I haven't used bulkheads at tops of tanks in a couple years. I use uni seal now and its the same hole saw size.

  • @Truprosoftwash
    @Truprosoftwash 4 роки тому +1

    Thanks great info needed it!!

  • @BrotherBrianHamilton
    @BrotherBrianHamilton 4 роки тому +2

    I really appreciate your videos. No filter needed with the pvc drop stick into straight sh?

    • @PressureCleaningSch
      @PressureCleaningSch  4 роки тому +1

      If your batch mixing, and/ or having to fill your tank w the lid open then I’d recommend it. That just increases the chance of getting trash in there. Since we don’t match we’re have to have our lid open to fill the tank I don’t see the need for having a filter. I feel they block the flow

  • @alwoolhouse6255
    @alwoolhouse6255 Рік тому +1

    Came here for the string tip on getting a bulkhead connector into the bottom of an IBC. Thanks.
    Those hose clips are trash, ear hose crimp clamps are far better.

    • @PressureCleaningSch
      @PressureCleaningSch  Рік тому +1

      Well I wouldn't say trash but you are correct the ear hose are better, and we use them occasionally on certain situations, but I prefer the ones I use for easier removal when needed.

    • @alwoolhouse6255
      @alwoolhouse6255 Рік тому

      @@PressureCleaningSch Yep, certainly easier to adjust/remove. And OK for low pressure applications. Just working on a project right now. I need a barbed connector in a high pressure system that will not need to be disassembled. I might prototype with jubilee clips first.

    • @alwoolhouse6255
      @alwoolhouse6255 Рік тому

      @@PressureCleaningSch I should have qualified my comment; cheap Chinese worm drive hose clamps are trash.

  • @mariaequihua8501
    @mariaequihua8501 Рік тому +1

    If I have a 3/4 fitting for my pressure washer tank what size should I use for cutting into the tank?

  • @Thetruthhurtstrump2024
    @Thetruthhurtstrump2024 2 роки тому +1

    Hey Doug I have a 2 inch suction hose that runs from my buffer tank to my pump inlet .I noticed today that on one of the hose barbs there is a small drip is that normal?

    • @PressureCleaningSch
      @PressureCleaningSch  2 роки тому +1

      No. Not normal. Need to fix that

    • @Thetruthhurtstrump2024
      @Thetruthhurtstrump2024 2 роки тому +1

      @@PressureCleaningSch any suggestions?

    • @PressureCleaningSch
      @PressureCleaningSch  2 роки тому +1

      @@Thetruthhurtstrump2024 re do the barb. Use tru Blu on the threads and heat the hose then clamp it.

    • @Thetruthhurtstrump2024
      @Thetruthhurtstrump2024 2 роки тому

      @@PressureCleaningSch ohh i see , i didn’t use heat

    • @Thetruthhurtstrump2024
      @Thetruthhurtstrump2024 2 роки тому +1

      @@PressureCleaningSch I took your advice and I used 2 clamps and now it is bone dry. I noticed two of the bulkhead fittings and both of my chemical tanks have small leaks I was told to use silicone grease? Is this true?

  • @EZchairchillen
    @EZchairchillen 3 роки тому +1

    Love your informative videos Doug!! I do have a question, if you don't mind. You said use a 90 or a straight fitting, why not use a 45 instead of the 90? My thinking is that it would improve flow

    • @PressureCleaningSch
      @PressureCleaningSch  3 роки тому

      You certainly could use a 45. Just don't wan the hose bending down or kinking is all.

  • @rckintz
    @rckintz Рік тому +1

    What size bulkhead fitting should I use for a 5.5 gpm belt drive pressure washer to make sure I’m getting the correct amount of water to my pressure washer. Should I use a 1 inch or 1 1/2 inch ?

    • @PressureCleaningSch
      @PressureCleaningSch  Рік тому

      3/4 or 1”. But you’ll need a barb to match the inlet on the pressure washer

  • @pashagold
    @pashagold 2 роки тому +1

    RectorSeal No. 7 is good but its for metal only not plastic. I've been using Tru-Blu...

  • @premierpowerwashing6634
    @premierpowerwashing6634 3 роки тому +1

    Hey Doug great video.
    For the SH downstream drop stick should I be using a 1/2 bulkhead with 1/4 barb? Or if it better to use a 1/4 bulkhead altogether?

    • @PressureCleaningSch
      @PressureCleaningSch  3 роки тому

      Bulkhead use 1/2 inch. Then use a Poly 90 street elbow MPTxFPT then a brass 1/2 threaded X 1/4 barb into the 90.

  • @michaelc7283
    @michaelc7283 3 роки тому +1

    Hi Mr. Doug Rucker,
    I have a few questions on this tube bulkhead setup system.
    1. Can I use the inside tube setup for the pressure washer bypass? This way the water doesn't splash inside the tank or create bubbles.
    2. Is it best to keep both bypass and Hudson float on the opposite side where the water comes out on the bottom?

    • @PressureCleaningSch
      @PressureCleaningSch  3 роки тому +1

      1) yes you can do that 2) yes that’s how I do it. Less chance of creating turbulence at the outlet

    • @michaelc7283
      @michaelc7283 3 роки тому

      @@PressureCleaningSch
      Thank you....

  • @marcuswalker9172
    @marcuswalker9172 2 роки тому +1

    What size pvc pipe is that?

  • @dominickmazzeo6377
    @dominickmazzeo6377 3 роки тому +1

    Doug. Would you suggest using a bulkhead on the bottom of an SH tank to dump sh into a 5-gallon bucket? If so, any particular kind or way to install ?

    • @PressureCleaningSch
      @PressureCleaningSch  3 роки тому

      No I would not. The SH will eventually eat through the gasket causing a leak

    • @dominickmazzeo6377
      @dominickmazzeo6377 3 роки тому

      Ok… what do I use?

    • @PressureCleaningSch
      @PressureCleaningSch  3 роки тому

      @@dominickmazzeo6377 you’ll need an electric pump or some type of hand pump. Can you not fill it up when putting bleach in the tank?

    • @dominickmazzeo6377
      @dominickmazzeo6377 3 роки тому

      I have a hand pump but when the chem factory pumps me off they put it into a 15 gal carboy. I like to rig it for an easy dump into a 5 gallon bucket for when I pretreat concrete. I use an xjet for that so it’s a stronger mix. The hand pump is a pain. I’d like to put a hose to a bulkhead so I can just pour out what I need. Hose to PVC ball valve

  • @adamg.3138
    @adamg.3138 3 роки тому +1

    How well does a 16 inch run on a 5.5 2500 psi gp gx390 pump? Thinking of upgrading to a 20 inch.

    • @PressureCleaningSch
      @PressureCleaningSch  3 роки тому +1

      Should work fine just might need to change the nozzles to a bigger size. Is the 16 inch new or you had it awhile?

    • @adamg.3138
      @adamg.3138 3 роки тому

      @@PressureCleaningSch The 16 is a Whisper Wash that I’ve had about two years now. I Ran it with a Home Depot Dewalt 3.5 gpm. The pump just went bad on it last week. I rented a Pw after my pump went bad and the Whisper wash wouldn’t kick on when I hit the trigger. No pressure. I cleaned the tips and all! I don’t know what’s wrong with it. Ever since the Dewalt broke down the surface cleaner hasn’t worked.

    • @adamg.3138
      @adamg.3138 3 роки тому +1

      @@PressureCleaningSch Should I put 1503’s, 2503’s, or 4003’s ? I’ll probably order all 3 just wondering your opinion if it’ll work on the 16 inch with my 5.5. May upgrade to a 20 inch.

    • @PressureCleaningSch
      @PressureCleaningSch  3 роки тому

      @@adamg.3138 if try 2503,&25035. But not a bad idea to try them all.

  • @BadWeatherfreak
    @BadWeatherfreak 4 роки тому

    Awesome video Doug. Question what is your take on installing a bulk head vs just using drop stick by opening the lid of the tank with a 12v pump?

    • @PressureCleaningSch
      @PressureCleaningSch  4 роки тому +2

      I don’t like drop sticks and opening lids due to the off gassing causing rusting issues equipment and truck/trailer.