3 PHASE INDUCTION MOTOR WINDING CHECKING

Поділитися
Вставка
  • Опубліковано 18 бер 2022
  • #motor,#winding,#windingcheck, #shorts
    📚📚📚📚📚📚📚📚📚
    Training Course & Electrical Practical Guidelines Available
    1.Begineer - Industrial Automation course ||PLC||HMI
    2.Electrical - Handbooks - 200 Books
    3.Electrical Notes || Practical Guidelines || Standards
    4.Electrical Calculation|| Excel Sheet
    5.Electrical - 5 Android App
    6.Basic Electrical Engineering - தமிழ்
    7. Hydraulic & Pneumatic Training
    8.VFD Training
    9.Power Systems Protection Training
    10.Electrical Schematics Reading Training Course||Tamil||English With Subtitles
    👆👆👆👆👆
    If u Wants
    Kindly Contact below Mail (or) What's up
    electricalinfo.ta@gmail.com
    (OR)
    Message
    Electrical Info - தமிழ் on
    WhatsApp Number
    Msg (or) Call
    +918838515341
    wa.me/message/HTHJQG25J25BJ1
    Urs ELECTRICAL INFO - தமிழ்
    Thank you
    Official
    Electrical Info - தமிழ்
    Whatsapp Groups
    Join
    Click Here
    👇👇👇👇👇
    chat.whatsapp.com/JlhNvO6YwJ3...
    How To Test Three - Phase AC Motors
    The basic steps in ascertaining the health of a three-phase AC motor are given below:
    (a) General Inspections
    (b) Earth Continuity and Resistance Test
    (c) Power Supply Test
    (d) AC Motor Winding Continuity Test
    (e) AC Motor Winding Resistance Test
    (f) Insulation Resistance Test
    (g) Running Amps Test
    General Inspections
    For the three-phase motor, do the following:
    (1) Check the appearance of the motor. Check for burnt, damage to body or cooling fan or shaft.
    (2) Manually rotate motor shaft to examine bearing condition. Look out for smooth and free shaft rotation. If shaft rotation is free and smooth, bearing is possibly in good condition, otherwise consider replacing, repair or carry out further diagnosis.
    (3) As with all testing and inspections, the motor name plate provides valuable information that will help to ascertain the true health of the motor. Examine the name plate thoroughly and compare values of running amps test (see below) with name plate value
    Earth Continuity and Resistance Test
    With a multimeter, measure the resistance between motor frame (body) and earth. A good motor should read less than 0.5 ohms. Any value greater 0.5 ohms indicate trouble with the motor. Further troubleshooting maybe required
    Power Supply Test
    For three phase motors, the expected voltage for a 230/400V system is 230V phase to neutral and 400V between each of the three phase supply lines. Check that the correct voltage is applied to the motor using a multimeter. Ensure the terminal for power supply is in good condition. Check the connection bar for terminal (U, V, and W). For three phase motors, connection type is either Star (Y) or Delta
    AC Motor Winding Continuity Test
    Using a multimeter, check the continuity of motor winding from phase to phase ( U to V, V to W , W to U ).Each phase to phase must have a continuity if winding is OK. If any particular phase fails the continuity test, your motor is probably burnt.
    Please see how to identify three phase windings for proper winding identification. U, V, W is a European winding designation.
    AC Motor Winding Resistance Test
    Check the motor winding resistance or ohms reading using a multimeter or ohmmeter for phase to phase terminal ( U to V,V to W ,W to U ).The ohms reading for each winding must be the same (or nearly the same). Remember that the three phases have identical windings or nearly so!
    Insulation Resistance Test
    Insulation resistance failure of an electric motor is one of the first signs that the motor is about to fail. For a three phase motor, insulation resistance is usually measured between each motor winding or phase and between each motor phase and motor frame (earth) using an insulation tester or megger. Set the voltage setting of the insulation resistance tester to 500V. Check from phase to phase (U to V, V to W, W to U). Check from phase to motor frame (earth) (U to E, V to E , W to E ). Minimum test value of motor insulation resistance is 1 Meg Ohm (1 MΩ). See how to measure insulation resistance of Electric Motor
    Running Amps Test
    With the motor running, check the full load amps (FLA) with a suitable meter or preferably a clamp on meter and compare with the name plate FLA. Deviations from rated FLA could signify problems with the motor under test
    Tags:
    3 phase induction motor advantages,
    a 3 phase induction motor is essentially a,
    a 3 phase induction motor is mcq,
    a 3 phase induction motor has,
    3 phase induction motor basic electrical engineering,3 phase induction motor construction and working in tamil,
    3 phase induction motor chapter,
    3 phase induction motor diagram,
    3 phase induction motor design,
    3 phase induction motor diploma,
    3 phase induction motor dol starter,
    3 phase induction motor drawing,
    3 phase induction motor design calculations,
    3 phase induction motor electrical dost,
    3 phase induction motor efficiency formula,
    3 phase induction motor head,
    3 phase induction motor full course

КОМЕНТАРІ • 36