Rv furnace not working?

Поділитися
Вставка
  • Опубліковано 15 жов 2024
  • We are seeing furnace issues daily during the winter months and the majority of them are due to being dirty. In our part of the country bugs are heavy during the spring and summer months. It’s very common for them to build nest in your furnace, water heater, and fridge. The majority of you will most likely use your fridges and water heater during the summer but chances are your furnace won’t be getting turned on.
    You can see where I’m going with this. Without the furnace being serviced and cleaned on that first chilly day you might find the furnace not working. There are some things you can do to help keep the bugs out. Bug screens are a great idea as well as running the furnace periodically. This may be tricky in the summer when the temperature is hot. Another good practice is to blow out the exhaust and I take ports with a air compressor. Be sure to wear glasses and a dust mask. You would be surprised at what will come out. Don’t just stop with your furnace tho. While you have the air compressor hooked up do the fridge and the water heater as well.
    These few things can prevent a lot of headache down the road and keep your appliances in working order. Hope this helps and prevent you from having a long cold night without heat.

КОМЕНТАРІ • 187

  • @Johnnyledwards
    @Johnnyledwards 2 роки тому +5

    Thanks for your excellent video. The contacts on my sail switch were corroded. I removed, cleaned and applied a thin film of dielectric grease to the blades. Problem solved. Thanks so much! You saved me a fortune!

  • @alularussell778
    @alularussell778 7 місяців тому +1

    Yep ! You did it, you showed me how and now my heater works so nicely so you're our hero man and thank you

  • @leeannevarble4307
    @leeannevarble4307 Рік тому +2

    Very informative! Thank you. Checked the sail switch and it's working. But the issue is the heat coming out is just barely warm, and definitely not warm enough to heat the camper. All trouble shooting info I've read is for not blowing ANY heat....ours is blowing a little heat. I would like to know your opinion on this. Thanks again for your expertise!

    • @peakmountaincamps
      @peakmountaincamps  Рік тому +1

      Sounds like the air is going elsewhere. Very possible to have a duct collapsed or mice have tore holes in.

  • @zachy-koon
    @zachy-koon 2 роки тому +3

    We've had a recurring issue with our dometic furnace, exact same issue as described here: fan kicks on and it runs through the safety checks--every once in a while it will ignite and bring the room to temp, but then it will not re-ignite on subsequent cycles. There is no ignition (no clicking on the igniter).
    I've troubleshot the issue and the sail switch is clean and works as expected, measured with an ohm-meter. The fan kicks on so no issue with the limit switch. I jumped the thermostat wires and there were no issues. Voltage is 13.2+ (lithium batteries) at the furnace. 11-inch water column, tested at the stove, so the regulator seems to be working fine (esp. since other propane appliances have no issues).
    The first two "times" (times=several days of issues) the only common denominator was me disconnecting the propane line to test it and then reconnecting. I even had a guy come out and troubleshoot and he found no issues either. Thus, we both concluded it might be an airlock in the propane line, fixed by disconnecting and reconnecting the line.
    However, this third "time" (currently) I have disconnected the propane line, reconnected, and run the furnace, but no dice. Fan blows as normal, but no clicking/ignition. I have no clue what this could be. Any ideas?

    • @peakmountaincamps
      @peakmountaincamps  2 роки тому

      How old is the furnace?

    • @zachy-koon
      @zachy-koon 2 роки тому

      @@peakmountaincamps was manufactured in 2020, purchased the RV in 2021.

    • @peakmountaincamps
      @peakmountaincamps  2 роки тому +1

      Let me put a video together of a common issue that I’ve run into on these newer furnaces. I’ll try and get it on the channel within the next day or 2.

    • @manyfeather2knives423
      @manyfeather2knives423 5 місяців тому

      Has this vid come out? I’m having the exact symptoms as you are. Any luck yet????

    • @peakmountaincamps
      @peakmountaincamps  5 місяців тому

      I don’t recall what the title was…quick fix or something like that.

  • @icasey8314
    @icasey8314 4 місяці тому

    Great video on explanation of cold air with igniting. I had this same problem on my furnace, now one more issue... I smell propane leak from furnace.

  • @joshburum9770
    @joshburum9770 Рік тому +3

    So we had replaced the Sail Switch, then we replaced the mother board and it was still lighting and instantly going out. See about 6:16 of the video for the key that FIXED OUR UNIT! Just mentioning that the exhaust should be capped so it wasn't instantly intaking the CO2 and putting itself out FIXED OUR UNIT! Thank you all so much!! It's snowing here in SW Oregon and we really needed our furnace. :)

    • @romeoperez73
      @romeoperez73 11 місяців тому

      So do you keep it caped in the camper

  • @eddiebezzell
    @eddiebezzell 10 місяців тому +1

    Thanks so much. As funny as it sounds no other videos turned a physical switch on! I went back, checked the switch and it had been turned off!!!!
    It went back to dealer for water heater not working from new and they saod it had not been plugged in from thhe factory? Why now was the furnace switch turned off? It worked until it went for warranty work??
    Creating profit from more work maybe? You have to physically take off the panel with screws to get to the furnace and it is completely seperate to the water heater.
    If it was not for your video i was at a blank.
    Thanks

  • @alularussell778
    @alularussell778 7 місяців тому +1

    What a great vid man. Now I'm going to attempt it and I'll let you know if I blew up anything. Thank you.

  • @USNERDOC
    @USNERDOC 3 роки тому +4

    Great info! I must have missed this one when it came out. Always appreciate these more technical insight videos. 👍

  • @jeffwarhawk517
    @jeffwarhawk517 5 місяців тому

    My friend has a momentum grand design 25G as a 30,000 BTU suburban heater . He says when the temperature is 50° outside it works properly when it drops below heater shuts off and it goes into lockout mode and has to manually restart it, but does not keep his camper warm.

  • @elkarlo5330
    @elkarlo5330 Рік тому

    Superb, it was the sail switch on mine. I was thinking the bounce when traveling causes it to wear out.

  • @robertherrera84
    @robertherrera84 Рік тому

    Excellent video but I still need help… I swapped both switches and still does the same turns on and off. You can feel the heat when it starts but it goes back to cooling cycle

  • @independentfool
    @independentfool 29 днів тому +1

    After I reinstalled my furnace, it would not sustain a flame. Turns out I didnt have the exhaust poked out the trailer as far as it should. It was only 1" difference ! Now it runs fine.

  • @vaughnburrows
    @vaughnburrows 3 роки тому +2

    Thanks for taking the time to show that.

  • @ToddLowery-o1u
    @ToddLowery-o1u 10 місяців тому +2

    What is possibly wrong when it goes the the lighting process, blower turns on, you can here it click but doesn't ever lite, doest the clicking about 3 times then goes to lockout and turns off. Yes there is propane and it lites at the stove.

  • @cherylsutton2936
    @cherylsutton2936 2 роки тому

    Truly helpful illustration, my 2018 grey wolf did the exact same thing. I turn the suburban switch on the wall to warmer. The furnace ran about 30 seconds, it cut off. Now I had to watch this video to see if I did something wrong? Thanks so much… Do I leave the switch on warmer? Now the switch on the wall is not working.

  • @cary2677
    @cary2677 Рік тому

    Thanks for the video. My sail switch had some carpet fibers in it from the fan.

  • @bryanhelton9791
    @bryanhelton9791 2 роки тому +1

    Your video was very helpful...I just wanted to thank you for sharing it....

  • @madebydoug
    @madebydoug Рік тому

    Thanks for your help....yup sail switch

  • @larrymays5413
    @larrymays5413 Рік тому

    Good afternoon Josh, Just watched you Video very well presented and informative. My furnace will not stay lit. I turn it on the fan starts, I can hear the igniter activate, I can feel heat out the exhaust and smell propane. It will run for 1-2 seconds and then stop. It will do this 3 times then it will not try to ignite unless I turn it off and back on. I have good gas pressure at the stove. I do not have an outside access panel. My trailer is about a 1996 Jag by KZ 23 KZ 5th wheel. Any help would be appreciated. Larry

  • @davidfarquhar6483
    @davidfarquhar6483 Рік тому

    When I saw the airtight furnace in your trailer I smiled with delight. Instead of gonna get me some kibble and bits I'm gonna get an airtight!!
    Ok, seriously; RE: Atwood Hydro Flame Two Stage 1522 DCLP
    My furnace lights but will not sustain burning longer than a few seconds once off of pilot. So far, I have pulled the burner head out and cleaned it up as well as the Ignitor and set the gaps. The stage of burn after the pilot cuts off increased from a second or two to about 8 seconds.
    I am wondering if the gas orifice might be restricted. Same result using a different LP supply (30 litre) tank.Would you hazard a guess as to the problem?
    On order to replace are:
    1) High limit switch 37022 190 degrees F
    2) Sail switch 36680
    3) The circuit board 34696
    Any insight is welcome,
    Best, David

    • @peakmountaincamps
      @peakmountaincamps  Рік тому

      What elevation are you at? What model furnace?

    • @davidfarquhar6483
      @davidfarquhar6483 Рік тому

      @@peakmountaincamps Atwood Hydro Flame Two Stage 1522 DCLP about 13 yrs old at Sea Level
      Fridge/freezer runs on LP/AC/DC No Probs Stove lights 3 burners, all strong flame Compliments on your lightening response, humanity is alive!!
      Also of interest is on the circuit board there is a red light that flashes twice indicating "ignition failure"

  • @georgecole1311
    @georgecole1311 Рік тому

    Great video, my question is do I have to pull out my furnace to change the switch?? Can I leave it in my rv which is a 5th wheel Jayco?? Thanks

  • @tfosters01
    @tfosters01 2 роки тому

    Great video, thanks. I have the same heater and had a lot of soot so I pulled the unit and tried to blow it out and shop vac it to clean out the heat exchanger. I tried to snake it out beacause I think mud daubers got in there. Is there a baffle mid way through the ecchanger? I could ony pass the snake through 1/2 way in each direction.

  • @annnorwich5857
    @annnorwich5857 3 роки тому +2

    Great video and explanations. Thank you for sharing your expertise.

  • @user-zu9ym2lw3i
    @user-zu9ym2lw3i Рік тому

    Thank you very much. This is exactly what is happening to my furnace.

  • @Nfc21d
    @Nfc21d 3 роки тому +1

    Great video I went camping this weekend with our new camper. I picked the camper up Wednesday and went camping Friday I turned the furnace on in the evening and it worked great all night cycled like it's supposed to.went to use it Saturday evening and it wouldn't lite it just blew cold air. I turned it on and off about 4 times and it finally worked I turned it off Sunday morning and then tried it when I got home and it's doing the same thing. it's a brand new unit any ideas thanks

    • @DK1able
      @DK1able Рік тому

      Did you ever find a solution? I have the same problem. The new sail switch left me with the same result.

  • @daltonbrown8048
    @daltonbrown8048 2 роки тому

    Awesome video. Very informative! What should I look for if the the fan was kicking on but no heat like in this video and now the fan isn’t even kicking on at all?

    • @peakmountaincamps
      @peakmountaincamps  2 роки тому

      I would verify power first. If you have power at the switch then I would suspect a circuit board.

  • @mkcumpston5467
    @mkcumpston5467 Рік тому

    Everything works on my SFV42Q except the propane heat. I have replaced the regulator, the control board, the sail switch, and put a shorter propane hose on (6') i stead of 10'.

  • @joelicenhour10
    @joelicenhour10 11 місяців тому +1

    Thank you for your input

  • @TheJasonVoorhees
    @TheJasonVoorhees 3 роки тому +1

    My issue is the fan runs but heat wont kick in, but, if i run the stove burner and hot water heater for a minute then the furnace heat will kick in...

  • @MainHome
    @MainHome 3 роки тому +1

    Please show the limit switch, i can hear the sale switch make contact and the ignition does start. The i burner does not stay on, it turns off like the thermostat has reached its temperature.

  • @sergiogutierrez1317
    @sergiogutierrez1317 Рік тому +1

    Awesome thank you so much, I have this exact problem, I'm gonna try it 😊

  • @deanduchene4035
    @deanduchene4035 2 роки тому

    Looking for help. Atwood furnace will go threw the 3 try starts. It’s igniting but not staying on. Replaced burner,electrodes and gas valve. Any suggestions what to try next. Thanks for your channel!!

  • @markh1938
    @markh1938 3 роки тому

    That’s the furnace I have but it looks like they installed furnace the built bedroom wall and installed kitchen cabinets around it, I have no way to access the sail switch. But thanks for the great concise video

    • @Stuffonyourknee12
      @Stuffonyourknee12 3 роки тому

      I have the same issue. I would have to break a shelf in one of my cabinets in order to remove the furnace to get to the switch. I only have the vent on the outside of my camper. I’m wondering if there’s any way to access the switch if I remove the vent on the outside but from this video I think I still couldn’t get to it.

    • @markh1938
      @markh1938 3 роки тому

      @@Stuffonyourknee12 I don’t think you can get to switch from outside. I did read sometimes tapping “gently” with hammer can sometimes free up switch. It’s not a huge problem now since we are heading into summer but we use our RV into Dec and it can get pretty chilly. I’m just amazed at the poor design or laziness that went into installing this. But I take some comfort in knowing I’m not alone, lol

    • @Stuffonyourknee12
      @Stuffonyourknee12 3 роки тому

      @@markh1938 Farther down in the comments I read someone banged on it too lol. So I tapped it with a butterknife because it’s the only thing long and skinny enough to reach. It worked! It’s warm now thankfully. My son and I froze last night. I stayed up until 1AM troubleshooting and finally gave up. I had half my camper torn apart so I could access the “reset switch” which didn’t work. We are in Michigan and do lots of early late camping too. We have the summer to figure it out, or buy a new camper 😂 I agree the design is very poorly planned.

  • @paulsmith1102
    @paulsmith1102 Рік тому

    You keep say fan or blower. You mean exhaust fan/ inducer?

  • @vancelombardi2953
    @vancelombardi2953 Рік тому

    Hi, thanks for the great info. I recently had to replace the circuit board on my furnace and now the fan will not turn off. It ignites and heats up but the blower just runs continuously even when the heat goes off. Any ideas? Thanks

  • @jray2319
    @jray2319 10 місяців тому

    I have a Wolf Pup 17JG. We haven't used the furnace in a year. It worked fine then, but now nothing. No fan, seemingly no power, nothing. From what I've looked at, including this video, it's probably not the sail switch. Would that possibly be the limit switch or something more?

    • @peakmountaincamps
      @peakmountaincamps  10 місяців тому

      I would verify power first. Both at the furnace and at the thermostat.

  • @ricksullivan7033
    @ricksullivan7033 2 роки тому

    Very informative. I have an AFMD25121 FAN NOT START. The board has a single blink. Any suggestions? I did hit the reset button as well. Nothing.

  • @skycastellanos8005
    @skycastellanos8005 3 роки тому +1

    Thank you we. are going to go try to fix this with your help

  • @jackantoine5185
    @jackantoine5185 2 роки тому

    Great information. May the dometic furnace tries to start and you can feel heat for a second then it shut off. I understand that would not be the sale switch. Any thoughts on this problem. Thanks in advance

  • @tdwagner6654
    @tdwagner6654 2 роки тому

    Great video!!! Have a question. Went to fire up our Atwood AFLD40121 last Friday evening, there was absolutely nothing. No fan, no clicking, nothing. I have the furnace out of the 5th wheel, just wonder what I should be looking for.

  • @radrussian8826
    @radrussian8826 2 роки тому

    My furnace runs. But after a while it won’t kick back on. I have to turn the power off. Leave it off for 10 seconds turn it back on and then it will fire back up. Any advice would be greatly appropriated. Thank you.

  • @bmoore3199
    @bmoore3199 2 роки тому

    My 2019 Dometic furnace will operate perfectly on shore power however it won't start up on 12.v battery. Strangly while it is running on shore power then I disconnect shore power it will continue to run for 1 to 1 1/2 minutes then shuts down. My battery approximately 20 months old and shows fully charged at 13.4 volts. Ive even attached jumper cables from my truck (has 2 batteries for diesel engine) to the rv battery and straight to the rv cables unattached to rv battery and nothing changes. I've replaced the flame sensor/igniter, cleaned the sail switch, tested the high limit thermostat even replaced the control board with a dinosaur board which I have since reinstalled the factory board. There was a recall on the lp regulator so I've even replaced it. Like I said earlier furnace runs fine on shore power just not on battery. Any thoughts ?

  • @bobcole3852
    @bobcole3852 3 роки тому

    Good explanation. Our 5 month old trailer has this issue, and no outside access. Stupid design...
    BTW, watched a bunch of videos on this and wonder why almost everyone pronounces sail like sell or cell. Sail on a boat or sale as in real estate is a libit different

  • @montemontague4298
    @montemontague4298 Рік тому

    I have an Atwood furnace. Works fine when weather is dry. When rains for a couple days it won’t work at all. Any tips?

    • @peakmountaincamps
      @peakmountaincamps  Рік тому

      How old is it? Some had a recall were they provided a bracket to relocate the circuit board so it didn’t collect water on it.

  • @ErnieTaylor-co5mh
    @ErnieTaylor-co5mh 4 місяці тому

    what will cause a power surge when starting furnace

  • @mikelazok
    @mikelazok 2 роки тому +1

    I have this same furnace. I'm having an incomplete combustion event. My exhaust tube and grill plate are black. I can also smell an incomplete burn in the fuel coming into the trailer from the vents. I shut the furnace down but need to tear into it. So you have any pointers where to look? Maybe a plugged Orifice?

    • @DilianMitev
      @DilianMitev Рік тому

      Did you figured it out? I am experiencing the same issue.

  • @deanannis7302
    @deanannis7302 11 місяців тому

    We just put a new furnace in our camper it is a jayco eagle 2022 the fan come on but it don't blow hot air what should I check or do

  • @DanielHaste-bb9uw
    @DanielHaste-bb9uw Місяць тому

    I have a serburban furnace that I've changed both sail switch and limit switch but still won't fire up

  • @andyphuong4826
    @andyphuong4826 2 роки тому +1

    Very helpful and life saver.

  • @debrarogers2512
    @debrarogers2512 Рік тому

    Blower works furnace cycles but will not light .Changed limit switch and sail switch but no change??

  • @debrarogers2512
    @debrarogers2512 Рік тому

    I’ve changed sail switch and limit switch and furnace still will not light. Blower works and it cycles but will not light

  • @Edward-ez4lr
    @Edward-ez4lr Рік тому

    Two wires on the sail switch. One comes right from the thermostat the other has two wires spliced together that goes to limit switch does it matter which wire goes where on the sail switch I look at it it shouldn't matter its just a switch

  • @joemccaulley4146
    @joemccaulley4146 Рік тому

    I have a 2008 cougar rv my furnace just stopped working! When I turn the thermostat up to kick the heat on all it does is click! I have 3 red lights on where the fuses are in my convertor box! I replaced the fuses but I got no change! Any help you could give me will be greatly appreciated! Thank you in advance for your time and help

    • @peakmountaincamps
      @peakmountaincamps  Рік тому

      Is the click coming from the furnace itself? There is a on/off switch on the furnace itself. You just have to get access to it.

  • @darrellmendiola3495
    @darrellmendiola3495 2 роки тому +1

    Great info. Thanks

  • @johnpetrowski6854
    @johnpetrowski6854 2 роки тому

    Thanks for the video. I have this furnace and it does not blow out exhaust Like it used to and is leaving soot outside. any idea what is causing this? the unit is 3 years old

    • @peakmountaincamps
      @peakmountaincamps  2 роки тому +1

      My guess would be dirty combustion chamber. Very common to have insects build nest and there.

  • @martinoverla4922
    @martinoverla4922 Рік тому

    Will the future pull it easy

  • @bike4him589
    @bike4him589 2 роки тому

    I have a Dometic with no easy access. The blower comes on I hear clicking but the gas never ignites. I have a new propane tank, the stove top burners are getting gas. If the sail switch also controls a gas valve then I'll take this unit out and check the sail switch. but I'm just not sure. Any ideas?

  • @TorbertTrio
    @TorbertTrio 3 роки тому

    HELP PLEASE!! 😩
    We live full-time in our Montana 5th wheel.
    we are a missionary family but due to Covid... are ‘stranded’ State-side.
    We are in SouthEast TX. Today is day 1 of a very strong ice-snow front coming.
    We are seeing that our HEAT FURNACE is not blowing, clicking, igniting.... nothing. 🥶
    Cant bring it in... since we live in it. Mobile RV repair is backed up.
    ❓’water’ was in the ignite area when my husband went to light it.
    WHAT COULD POSSIBLY BE OUR PROBLEM?
    TIA 🙌🏻👍🏻

  • @robertoneal9111
    @robertoneal9111 Рік тому

    Have a furnace that lights up for 30 seconds and shuts off. What could be wrong 🤔

  • @EdnaPhythian
    @EdnaPhythian Рік тому

    I changed my sail switch but still having the same issue. What else might I try? It runs through the safety mode but never lights.

  • @ironcitypete1
    @ironcitypete1 3 роки тому +1

    My furnace fan will not come on. I have bypassed the thermostat and replaced the circuit board but the fan still won't kick on. The board LED will blink error code 1. Applying voltage directly to the motor will spin up the fan. Any ideas on what else I can check?

    • @peakmountaincamps
      @peakmountaincamps  3 роки тому +1

      have you verified that you have power? possible blown fuse? could also be the reset breaker on the furnace.

  • @tomkluck5261
    @tomkluck5261 2 роки тому

    I replaced the limit switch but the furnace continues to turn off. Should I replace the sail Switch? I thought because it starts heating it wouldn't be the sail switch. ??

    • @peakmountaincamps
      @peakmountaincamps  2 роки тому

      Have you tried blowing the exhaust port out. Sometimes if there is the blockage it will burn for a bit and then go out. You could also try cleaning the electrode.

  • @jamesbondaygee
    @jamesbondaygee 3 роки тому

    Hey bud. My Atwood Furnace was fine just until yesterday. Now fan won't even start. Checked fuses. Not the issue. What is the likely cause in your opinion? Thanks, James

  • @keeleyafleming
    @keeleyafleming 2 роки тому

    Thanks for the video. I have an atwood model 7920-11. I can turn it on sometimes it works for 45 minutes then shuts off. Never to restart again for hours. Any suggestions?

  • @matthewhooks452
    @matthewhooks452 2 роки тому

    It’s summer. Something in my furnace is making a whomping sound like it wants to come on by itself even though it’s in off position.
    Turned it on just to test, everything worked. I shut it off. 5 minutes later it started womping sound again.
    I had to pull the fuse. Any idea what could be causing this?

  • @sully-alacumba
    @sully-alacumba 3 роки тому

    Very good! Thanks for the fine video which I found very helpful.

  • @takeitallin6882
    @takeitallin6882 2 роки тому

    Any chance that is an Atwood AFMD 30121... which is what i have. It looks very similar mine.

  • @dennyo5085
    @dennyo5085 3 роки тому +1

    My furnace will go thru the safety's then I hear some clicking, it will not get warm but will run for several minutes before shutting down. Any suggestions?

  • @tomkluck5261
    @tomkluck5261 2 роки тому

    I have a Suburban SFV-35Q 35,000 btu furnac and when I turn it on it seems to run fine for about 3-4 minutes. Blower starts, it ignites, blows hot air then just stops. Does not seem to turn off and cool down, just stops. Any thoughts?

    • @peakmountaincamps
      @peakmountaincamps  2 роки тому

      Possibly a high limit switch

    • @tomkluck5261
      @tomkluck5261 2 роки тому

      @@peakmountaincamps Replaced the limit switch, tested outside of trailer and it ran for 10 minutes and I shut down. Put furnace back in trailer and it ran for 8 minutes and stopped again. Would it start heating if sail switch is no good?

  • @tonyringo4128
    @tonyringo4128 2 роки тому

    Thanks for the info, I have a hydroflame model number fa7916 that I couldnt find a combustion air tube for, any ideas on how to replace one, or where to find one? Any info would be appreciated. 👍🏻

  • @armandocepeda7763
    @armandocepeda7763 2 роки тому

    Thank you for the great video. It helped a lot. Keep up the good work.

  • @jackantoine5185
    @jackantoine5185 2 роки тому

    My domestic furnace is only two years old but it will try to start you’ll feel a minute of heat and then it goes right off it will do this continuously no three times and then shut off. Any ideas. Thanks in advance

    • @peakmountaincamps
      @peakmountaincamps  2 роки тому

      Sounds like an igniter to me. Could also be the circuit board.

  • @sharonknudson4154
    @sharonknudson4154 2 роки тому

    Liked, I have a Surburban SF35, and tried to change sail switch. Old switch says its 3A . replacement part says 1.5A, at first the blower would turn on, but now it does not. Is it possible to get a sail switch that it like the original?

    • @peakmountaincamps
      @peakmountaincamps  2 роки тому

      The blower should come on regardless. My guess is you have a blown fuse or thermostat is not calling for heat.

  • @homerguerrero
    @homerguerrero 3 роки тому +3

    Great video! How did you remove that type of furnace?

    • @peakmountaincamps
      @peakmountaincamps  3 роки тому +1

      Most just have 2 screws on the back side holding them down. You will have to remove the ducts by twisting them until the notches line up and slide out. You will also have to remove the exhaust tube from the outside. Other than that you will just have the 4 wires and the gas line. Pretty simple removal depending on where the manufacturer placed it and how accessible it is.

    • @homerguerrero
      @homerguerrero 3 роки тому

      @@peakmountaincamps the access is like an umpa lumpa cave. its definitely a sail switch, I give its bang on the housing and it turns on! once reached to desired temp; it never comes back on (with no bang)
      ill give it a look over tonight.
      Now, question, how difficult is it to switch over to to the ones with the exterior housing? im assuming its just part and labor and cutting the RV?

    • @Stuffonyourknee12
      @Stuffonyourknee12 3 роки тому

      @@homerguerrero OMG I wish I would’ve seen this last night. It would’ve saved my son and I a very cold night. I just banged on it and it’s WARM!!!! Ahhh! Thank you

    • @homerguerrero
      @homerguerrero 3 роки тому

      @@Stuffonyourknee12 I too was excited about this! Lol just make sure you only bang the housing with a wooden stick to avoid damaging other components of the furnace! Also, when you replace the sail switch, it’s beefier, so it won’t happen again

  • @normanschmidt209
    @normanschmidt209 2 роки тому

    My furnace turns on makes a clicking noise heats up for 10 seconds then shuts off the clicking noise never stops? Any ideas?

  • @lorialbrecht6792
    @lorialbrecht6792 Рік тому

    I just pulled mine out and cleaned the sail switch today. It was clogged with cat fur and wouldn’t ignite.

    • @peakmountaincamps
      @peakmountaincamps  Рік тому

      Very common in trailers with pets. Also common in trailers that are smoked in.

  • @DareCdn
    @DareCdn 3 роки тому

    I have an Atwood 7916 II furnace(Stamped on the circuit board is 06-235132-001) in a 98 Palomino popup camper, the furnace stopped working last year when I needed it the most, so I have been trying to figure it out, so far I have replaced the Sail Switch, Limit Switch, Electrode, and the Propane Tank regulator and thermostat. The furnace worked for a couple of days, then I tested it again a about a week later and I get nothing. Fan goes on, I here clicking, it tries three times and just runs the fan for another 30seconds and that's it, it keeps trying but without success. My only other thought is the Circuit board, what do you think?? Any help would be greatly appreciated.

    • @peakmountaincamps
      @peakmountaincamps  3 роки тому

      It could be a circuit board but not as common. Most shops can test the boards to see if they are working properly. It sounds to me like you have a gas issue or a spark issue. Where you have changed the regulator I would say spark.

  • @MR.KNOWITALL1982
    @MR.KNOWITALL1982 3 роки тому

    what if your working remotely trying to help someone, I need a schematic of a heater/AC system. Is there a place I can download them? Also, Can you get a complete schematics for the RV your working on? All the wiring diagrams I have found have wiring that is a different color??

  • @aarondalton3105
    @aarondalton3105 3 роки тому

    I have a 2001 wild wood 28 ft camper suburban heater will not do anything also the refrigerator will not light on the propane side but the Also hot water tank will not light but the stove will work I tried lighting them manually

    • @peakmountaincamps
      @peakmountaincamps  3 роки тому

      sounds like a regulator issue to me. When you attempt to light one of the other appliances with the stove burning does the flames drop?

    • @erikcable1755
      @erikcable1755 2 роки тому

      low voltage

  • @rogerstradley2268
    @rogerstradley2268 2 роки тому

    thanks for the help.

  • @markstutsman5882
    @markstutsman5882 3 роки тому

    my furnace is just like the one you used,the furnace will light and run for about 45 second and the reset switch kicks out and shuts everything down,thermostat also have any suggestions where to look

    • @Qingeaton
      @Qingeaton 3 роки тому

      Did someone install a filter for the furnace? They aren't supposed to have them and slowing down the airflow can cause strange behavior. If you don't have a filter on the intake, never mind, but if there is one, try it without.

  • @RojoFrijol
    @RojoFrijol 2 роки тому

    My atwood blower comes on, after a few seconds I hear the igniter clicking, it ignites the propane but only for a few seconds, then starts to click again, then ignites for a few seconds. Continues that cycle 3 times then shuts down. Would that be the sail switch?

    • @erikcable1755
      @erikcable1755 2 роки тому

      not the sail switch, dirty electrode lost signal to gas valve

  • @ThePeopleVerse
    @ThePeopleVerse 2 роки тому

    Hi, thanks for this video.
    Do you have an online source that regular folk can buy our parts at good prices?)
    Seems out local (50 miles away) rv places think their stuff is made from gold...

    • @peakmountaincamps
      @peakmountaincamps  2 роки тому +1

      Welcome to the Rv industry. It’s all overpriced. Amazon would be your best pricing but with that being said you don’t get the knowledge of a Rv technician or someone who will take care of you should issues arise with the product when buying from Amazon.

    • @ThePeopleVerse
      @ThePeopleVerse 2 роки тому

      @@peakmountaincamps Thanks for the reply.
      Yeah, I get that about the tech. The wife and I built our house, our monster truck and the hotrod, but still have someone "tune up" the hvac, and someone to build the transmissions as we just don't know all we need to know. Same goes for the rv. I guess the hardest part is figuring out how they put this thing together so we can get at what needs getting at....if you know what I mean.
      Thanks again

  • @tjatkinson88
    @tjatkinson88 2 роки тому

    Good stuff man, Thanks!!!

  • @jakegotto
    @jakegotto 2 роки тому

    I'm having an issue when at higher elevations. Heater works fine at 6000 ft. Anytime I head into the mtns of Colorado my heater does not want to light. Have you ever ran into this problem?

    • @peakmountaincamps
      @peakmountaincamps  2 роки тому

      What’s your propane level at? Also battery voltage. I’ve never had a furnace do that but I have had a couple fridges that wouldn’t operate at high altitudes.

    • @jakegotto
      @jakegotto 2 роки тому

      @@peakmountaincamps ya it can be a new bottle and running off generator power and still won't ignite. Come back down the mountain and it works perfectly.

  • @larryreese9072
    @larryreese9072 3 роки тому

    Atwood furnace on my RV stop working altogether it a 8525 IV DCLP no clicking no blower will not come need help, thanks

    • @peakmountaincamps
      @peakmountaincamps  3 роки тому

      Verify 12v power to the furnace first. If there is power there then verify that the thermostat is working. If both check out I would say most likely a circuit board issue. Could also be limit switch if equipped.

  • @savannahrei8674
    @savannahrei8674 3 роки тому

    I took my furnace out of the RV and was surprised to find water in the pan below the exhaust pipe near the combustion chamber. Its either condensation water or somehow is leaking in from outside. Is this normal?

    • @peakmountaincamps
      @peakmountaincamps  3 роки тому +1

      You will get condensation which shouldn’t be a problem as long as it the electrical components remain dry.

    • @lancewright21
      @lancewright21 Рік тому

      No it’s not

  • @PedroCancel
    @PedroCancel 3 роки тому

    I have a 1977 skyline noman that has a Duo-therm 65900 series ac dcdirect spark ignition furnace piolot light does go on motor does run howeve it will not heat when piolot light is on its extremely low almost a dot but when you go fron piolot to the on postion piolot turns off motor keeps running but no heat help. What can my problem be?? Help a newbe

    • @peakmountaincamps
      @peakmountaincamps  2 роки тому

      My guess is it might be time for a new regulator on your lp tanks.

    • @erikcable1755
      @erikcable1755 2 роки тому

      adjust pilot light and change thermocouple

  • @cs9575
    @cs9575 3 роки тому

    Great video. I have a old Hydro flame that's in a 1997 Toyota Itasca. It wasn't turning on so i bypassed the thermostat and clamped the 2 thermostat wires together and it wanted to start but motor was struggling to turn. I took the unit out and got the fan to work great. But now whenever I put power to the unit it turns on regardless of thermostat wire positions and fan wont turn off until I remove power by disconnecting it from battery. I only bench tested this without gas connected. Any idea why it just keeps running and wont turn off? Thanks so much. Any help would be highly appreciated!

  • @johnlamanna2120
    @johnlamanna2120 3 роки тому

    My dometic furnace is doing the exact same thing. I removed the sail switch and checked continuity and it was showing open, then short when you moved sail. I compared to new sail switch and got same reading. I even had the sail switch still wired and started furnace and manually moved sail, and it still would not ignite. What's next?

  • @janarawson1819
    @janarawson1819 2 роки тому

    Our heater kicks on, but the fan never clicks on. Could it still be this part?

    • @peakmountaincamps
      @peakmountaincamps  2 роки тому

      The heater shouldn’t ignite if the fan isn’t blowing. The way they are setup up has several safety procedures that it will run through first before ignition. The fan blowing is one of them.

  • @bc-guy852
    @bc-guy852 2 роки тому

    Brilliant! Thanks!

  • @freddiesanchez752
    @freddiesanchez752 2 роки тому

    Do you have part numbers for the switches? Thank you

    • @peakmountaincamps
      @peakmountaincamps  2 роки тому

      They vary from furnace to furnace but if you can get us the model number of your furnace we can get you the part number.

  • @jmm866
    @jmm866 2 роки тому

    Just bought a brand new 2022 with a similar furnace. Ran out of propane and now it wont ignite. Any tips??

    • @peakmountaincamps
      @peakmountaincamps  2 роки тому

      I would start by flipping the reset switch and see if that makes any difference

    • @jmm866
      @jmm866 2 роки тому

      @@peakmountaincamps
      So is the reset switch the black switch on top?

    • @peakmountaincamps
      @peakmountaincamps  2 роки тому

      @@jmm866 yes

    • @jmm866
      @jmm866 2 роки тому

      @@peakmountaincamps
      Ok. So I already tried switching it off for a minute or so and it just continues to not ignite. Fan comes on but nothing else. I lit the burners and they work. I also switched the fridge and water heater to gas hoping to purge system further. They are all lit too.

    • @peakmountaincamps
      @peakmountaincamps  2 роки тому

      @@jmm866 if fan blows but doesn’t ignite i would definitely lean torwards a sail switch as it is much cheaper than a circuit board. The scenario seems weird that either of those would be the culprit but without being check it personally I would say start with a sail switch as they are pretty cheap.

  • @victorhebert5774
    @victorhebert5774 3 роки тому

    I remove my furnace Atwood 8535-11. Clean everything change burner and clean element, put everything back together. But I think I cross the wire ground to positive and positive to ground its spark and now have nothing. What can be wrong? Thanks

    • @peakmountaincamps
      @peakmountaincamps  3 роки тому

      Hopefully you just blew the fuse but you very easily could have burned up the circuit board.

    • @victorhebert5774
      @victorhebert5774 3 роки тому

      @@peakmountaincamps Thanks, you mean the fuse on motor. Is there a fuse inside or work like a breaker. Says 10 on it

    • @peakmountaincamps
      @peakmountaincamps  3 роки тому

      @@victorhebert5774 there is a 10 amp fuse in the fuse panel in the trailer and then there is a breaker switch on the furnace

  • @stephinebarteni2729
    @stephinebarteni2729 11 місяців тому

    My furnace clicks but it dose ignite or start up from their

    • @peakmountaincamps
      @peakmountaincamps  11 місяців тому

      Could be a number of things. I would verify that you have propane to the furnace first off and then verify that you have 12volts at the furnace.

  • @thyhangman
    @thyhangman 3 роки тому

    I would add a simple ohms check on the sail switch to verify if it's opening and closing instead of 'guessing' js.

  • @billysingh5319
    @billysingh5319 3 роки тому

    I have a 1999 golden falcon i tried to start it this weekend and its sounded like it was stuck and the blower motor wasn't spinning and it didn't ignite ? Does anyone have an idea what it could be please.

    • @peakmountaincamps
      @peakmountaincamps  3 роки тому

      You can attempt to push start the motor if it’s bound up by rotating the blower wheel. To do this the furnace must be on and you’ll need access to the blower wheel. Once the furnace is on you can give the wheel a nudge to get it spinning. Be aware that if this is the issue that wheel will break free and spin at high rpm. So don’t try and break it free with your fingers...a flat blade screw driver should be fine. If this method works you might be looking at a new motor.

  • @Thorntonfamilyhomestead
    @Thorntonfamilyhomestead Рік тому

    Where are u located