Це відео не доступне.
Перепрошуємо.

PEX A vs PEX B: What's the Difference?

Поділитися
Вставка
  • Опубліковано 18 сер 2024

КОМЕНТАРІ • 427

  • @RadioChief52
    @RadioChief52 5 років тому +419

    Exactly what I want. Clearly, concise information in 4 minutes and 9 seconds. All done without a blaring soundtrack. Bravo sir. Thank you.

  • @johnbalogna803
    @johnbalogna803 2 роки тому +10

    ok now I'm confused I was always told that PEX A was more resistant to bursting as it has the ability to expand and then memory retract hence the expansion tool is needed to add couplings or valves into it. PEX B is much more rigid and I would there fore expect to to be more prone to bursting in a freeze situation

  • @juancastillo5078
    @juancastillo5078 2 роки тому +11

    A couple of things I would add. The inner diameter can be different on Pex-A and Pex-B. For instance we sell Uponor pipe with Wirsbo fittings. The fittings themselves have less restrictions than other types that we sell, so there is more flow. Also, the cold expansion products are forever trying to close and are less likely, if ever to have a leak. So our plumbers really like that.

  • @bobheide
    @bobheide 5 років тому +106

    So much more straight forward and to the point. Better then most other videos.

  • @baileysservices3165
    @baileysservices3165 2 роки тому +6

    Best video on the difference between the two pipes! Un-biased, providing a fair evaluation of the characteristic of both pipes…all in just a few minutes.

    • @TheHephaestus05
      @TheHephaestus05 Рік тому

      Except he failed to mention the most important difference! PEX-B has flow restrictions from fitting being smaller diameter, whereas PEX-A uses expansion fittings and does not have loss of flow...

  • @richmac918
    @richmac918 5 років тому +11

    Good video with no wasted time talking about irrelevant stuff or some sound track that no one wants to hear. I only have experience with Pex A. I find that most professional plumbers I know use Pex A but that might be a regional thing. Couple of other differences - Pex A has a larger inside diameter for the same corresponding size (more water flow) and the expansion fittings from Uponor are quick to install and once connected the pipe can actually be rotated around the fitting without leaking. On the down side, Pex A is not as readily available as Pex B which is sold in the big box stores like HD & Lowes

  • @boby115
    @boby115 5 років тому +89

    I think you forgot to mention that PEX A with expansion fittings have very little loss in line diameter at the fittings ; where PEX B has a greater line loss diameter do to fittings. Other than that I found your video very informative and in my opinion one of the best videos out there on this subject. Keep up the good work and thanks.

    • @Diehard65
      @Diehard65 5 років тому +2

      Have you ever tried looking up to find out exactly what those head losses are and how they compare?

    • @HyperPiperunscripted
      @HyperPiperunscripted 4 роки тому +1

      you say that but if you are connecting each to the same fitting neither will be smaller or bigger than the fitting itself because they go on the outside not the inside.

    • @joshm5816
      @joshm5816 4 роки тому +3

      @@HyperPiperunscripted You are correct. The uponor system is best. You don't have the volume and friction reduction as you would in crimp pex. Half inch crimp pex fittings will reduce to three eighths at all connection in half inch.

    • @Bshwag
      @Bshwag 4 роки тому +3

      @@HyperPiperunscripted not all fittings go on the outside. expansion and crimp go inside and last longer and expansion has a larger inner diameter.

    • @peggypenland1560
      @peggypenland1560 4 роки тому +1

      How do the newest shark bite connections work with pex. Good yes? Hope so. Just wanna get rid of all copper in my houses, sick of the pin holes and the panic when we have several freezing days in a row.

  • @mattman3495
    @mattman3495 3 роки тому +8

    Most my plumbing is retrofit / replacement. Usually do 2-4 bedroom two stories with a basement. I use PEX B 10' sticks, I don't even bother with the coil. It might cost a couple bucks more but there's no hassle of the coil, especially when it's cold out. I'm not doing new builds, if I have to splice a couple together it's no big deal. So much easier to work with the sticks. I've used enough coil in my day you might have less splicing but you spend far more time trying to straighten it out.

    • @frankmontez6853
      @frankmontez6853 3 роки тому +1

      yeah for simple repairs that probably the way to go . As DIY , just made a repair on galvanized pipe and it was tough . never again hopefully . Just too unforgiving galvanized . And it was section with three close nipples , two unions , two tees and an elbow . Three lines geez

    • @MichaelMillar85
      @MichaelMillar85 2 роки тому

      most of what i have done is 10 foot sticks of pex B never had any issues are call backs.

  • @rollinthrulife
    @rollinthrulife 5 років тому +31

    Wow, I’ve watched two of your videos and both professional and to the point, clear concise, thanks I appreciate the education!

  • @billloesch1884
    @billloesch1884 4 роки тому +4

    My compliments, PEX Universe, outstandingly well done!!! No BS, clear, concise. Only comment is a repeat of a previous comment that the pressure drop with A is less (better) than with B, because the fittings do not reduce the effective diameter, not an insignificant difference, especially when the copper tube community points this out accurately and repeatedly. Keep up the good work. Bill

    • @PEXUniverse
      @PEXUniverse  4 роки тому

      Thank you very much Bill! Great comment, next video where we talk about that difference we'll be sure to mention it!

  • @tacampbell
    @tacampbell 3 роки тому +20

    One of the biggest differences that you didn't mention was throughput and pressure drop.
    Expansion fittings (only safe to use with PEX-A) have a wider inner diameter, meaning less flow loss than inserts with metal-crimp fittings. Of course, you want to use as few fittings a possible in any case, but with crimp fittings you lose significant throughput and to some degree, pressure with each one. When using expansion fittings on PEX-A, this is much less. This is particularly important if you are working with on-side water systems (i.e. wells) which are often set for lower water pressure than city water systems.

    • @jeandeaux2129
      @jeandeaux2129 2 роки тому +2

      There are many videos on UA-cam demonstrating that expansion fittings work with both Pex-a & Pex-b-------therefore, your advice is spurious.

    • @stipcrane
      @stipcrane 2 роки тому

      Zurn Industries makes cold expansion fittings for PEX B pipe.

    • @TheHephaestus05
      @TheHephaestus05 Рік тому +1

      This is probably the most important difference between the two and he completely missed this.

    • @derrickm9808
      @derrickm9808 Рік тому

      I measured the inside diameter of the pex a expansion fittings and the pex b crimp ring fittings and they are the same so same flow.

    • @Grejegando
      @Grejegando Рік тому

      @derrickm9808 How is that possible? Think about it for a moment. Both pipes, Pex A & B, have the same inner diameter (ID). You use an expansion tool to widen the ID of a Pex A pipe and ring so you could insert the fittings into the pipe. Notice that pushing those fittings into Pex A pipe without the expansion tool is impossible. Conversely, when you push a Pex B fitting into a Pex B pipe it goes in easily because then you'd use the crimp ring to achieve the tight grip. This just tells you that Pex B fittings are smaller than Pex A fittings since they do not require expanding the pipe in order to be able to insert them. Without a larger OD fitting of type A than the ID of the Pex A pipe there would be a huge design flaw and a guaranteed leak every time. The fittings therefore have got to be larger than those of the Pex B type. It's really a no-brainer.

  • @BT3701
    @BT3701 4 роки тому +5

    I had all my old iron piping which was pretty must closed up on the inside and reducing water flow replaced with pex B. Love it

  • @ecr-9341
    @ecr-9341 6 років тому +35

    This channel is probably the best-all-around videos for people new to PEX (like me). Informative, clear, concise, and not 25 minutes long. MAGA...

  • @edbouhl3100
    @edbouhl3100 4 роки тому +4

    I’d love to replumb with copper K but the hard water from the Colorado River and the chloroamine treatments here in Southern California have the reputation of causing pitting and leaks in as little as a decade. So for the main line from the street I’m probably going with 1 inch Pex A with expansion fittings and then as much manifold pex A piping inside the house as I can. But while I’ve got the trench open, I’m going to install a backup CPVC Schedule 80 1 inch line, capped at both ends. Cheap insurance in case of problems with the primary line.

  • @michaelsolosky53
    @michaelsolosky53 6 років тому +24

    Clear, concise, informative and to the point. Well Done!

  • @triggerbill1
    @triggerbill1 4 роки тому +6

    My question I bought a roll of pex A 1/2× 300' to replumb my home. Also plumb cabin. My brother has the yellow Appollo ratcheting stainless steel cinch tool. They said at big box hardware store can only use expansion power pex fittings . They said stainless chinch rings and copper squeeze ring will leak on type A.

  • @kerrygibbs8198
    @kerrygibbs8198 4 роки тому +4

    Good information!! I’m a do it yourself guy. I started working with PEX about a year ago. I thought all PEX was the same. Thanks!!

  • @billvilla7799
    @billvilla7799 5 років тому +8

    1:57 PEX-a has the highest level of cross linking...correct. However, the amount of cross linking is not the only factor to do with pipe strength and durability.

  • @SunRabbit
    @SunRabbit 3 роки тому +2

    I'm using PEX-B to make art pieces but now I really want to try PEX-A. I never even knew there was a difference. I'm especially interested in the heat-treatment and heat-resistance aspect since I'm using heat to make my pieces. Thanks for the info!

  • @jdelozier8335
    @jdelozier8335 3 роки тому +5

    Didn’t catch it if you mentioned that Pex A is more resistant to freeze damage which could result in a lot of other damages in a home.

  • @tinman1955
    @tinman1955 3 роки тому +5

    What about the chemical leaching from these pipes? Harmful? Can be filtered out?

  • @Jack97798
    @Jack97798 2 роки тому +2

    Love this! Give us the facts and your points of view up front and with quick explanations. I like very few videos. However, this is worth

  • @osmanvincent1975
    @osmanvincent1975 4 роки тому +3

    PEX-A was developed and used in German in the 1940’s and has the longest history. PEX-B started in the 1970’s,
    One of the PEX’s, probably PEX-B, had and may still have a problem with leaking fittings from too much zinc in the brass alloy.
    There is also PEX-C and PEX-D.
    PEX has three weak links:
    It become brittle and crazed by UV light, a couple months in the sun, or maybe a couple years under fluorescent lights.
    It’s chewable by rodents who want to enlarge a pipe hole
    It is slowly destroyed by oxygen and maybe other chemicals dissolved in potable water over a century

    • @barrett9631
      @barrett9631 3 роки тому +1

      Hello it looks like you made a point I heard years ago when PEX was new on the Market. I heard talk about rodents mice could shoot through the pipes and cause problems leaking. Now many years later I haven't heard of one person claiming to have a problem with rodents chewing through the pipes. Do you have first-hand knowledge of rodents causing damage to PEX pipe? I'm not trying to be smart I'm just looking for information thank you.

    • @thefix2573
      @thefix2573 3 роки тому

      @@barrett9631 ua-cam.com/video/2PzkV4JTRUY/v-deo.html

  • @sagitario12ish
    @sagitario12ish 5 років тому +8

    Well, from now I will change my plumbing materials to pex A, good video!

  • @0385cdavis
    @0385cdavis 5 років тому +4

    Yes what Bob y commented, type A has a true size diameter as to which type B using compression fitting loses size. Another type type A manufacturer also includes "Apollo" and also has atleast a 3x faster connection to fitting speed with no effort compared to a ring crimper. Another note is the fittings used in type A can be turned even after installed inside the collar rings when using a T or 90, not sure if type B has that ability. I am certified by uponor which also comes with 100% lifetime warranty on their products and the damages that are ever caused when installed.

    • @kristinnlevey9757
      @kristinnlevey9757 2 роки тому

      you seem to know your stuff... why did he say pex a has a lower bursting pressure... as I previously learned it had a higher burst pressure which makes sense since it expands so well.

    • @waboswell
      @waboswell 2 роки тому

      No effort if you have a $400 expander.

  • @JDFuchs
    @JDFuchs 4 роки тому +2

    What sold me on PEX-A is the fittings. Its immediately obvious when one is installed incorrectly. Poor crimps to PEX-B can sometimes be missed. I've also seen videos of corrosion on the crimp rings leading to leaks years later.

    • @MrWhatahelisdis
      @MrWhatahelisdis 4 роки тому +1

      I've learned that metal fatigue also eventually leads to leaks with PEX-B. Less than 5 years in some cases.

    • @justdissin7340
      @justdissin7340 4 роки тому

      What do you guys recommend to use?

  • @pauldharmer
    @pauldharmer 4 роки тому +14

    If you use pex B the fittings will down size the pipe diameter one pipe diameter, very noticeable on an outside faucet, a tub ect

    • @dannystone4258
      @dannystone4258 3 роки тому

      yeah, he didnt mention the MOST important factor of bottleneck capacity reduction.

  • @jamesburgess3628
    @jamesburgess3628 6 місяців тому

    I will also would like to echo all the comments about this video. Straight to the point, without all the BS. I am going with Pex A for my retro fitting of my old house. Two reasons are that Pex A fittings are cold expansion and does not restrict the flow volume. But I was also lead to believe Pex A would expand in freezing situations more than Pex B. But after watching a lot of videos. They both have close to 1000 PSI before they burst. And both have similar freeze burst rate. Pex B doing slightly better than Pex A. But not a significant difference. I will be using pipe insulation on all my Pex A pipe that will be under my old house. That was built in 1905. On pier and beam foundation. Pex A is more expensive, but the big box stores are now carrying most of the Pex A pipe and fittings. Just make sure to Use Pex A fittings on Pex A pipe. There is a difference. That is the main thing I disagree with the video. There is a difference between Pex A and Pex B fittings.

  • @careymd
    @careymd 3 роки тому +1

    Nice to see a concise and to the point video on UA-cam

  • @TheJesse002100
    @TheJesse002100 4 роки тому +5

    Biggest difference is pex a is full true Id when using the expansion tool. This is very important in well systems where pex b with crimp rings reduces flow a good amount.

    • @DevilTravels
      @DevilTravels 4 роки тому +1

      Sounds like PEX-A is good for larger diameter main lines (3/4") and PEX-B is better for smaller single runs (!/2") off a manifold.

    • @michaelwright1602
      @michaelwright1602 3 роки тому

      @@DevilTravels Half inch Pex B off a manifold is roughly 3/8"... I do not understand the attraction of Pex B for this fact. I want water flow. My water pressure, and more than likely everyone else here is good on that, be it well or city water. The water flow is what makes the difference.

  • @treich1234
    @treich1234 4 роки тому +4

    No theatrics just facts...luv it

  • @markhuggett9475
    @markhuggett9475 4 роки тому +1

    I've worked for all three types of PEX manufactures, some of your information is correct and some not enough information. PEX A, B and C, have Pro's and Con's, but all three meet the strict NSF guidelines.

    • @srobeck77
      @srobeck77 3 роки тому

      theres no pros to PEX-B other than cost. inferior in every other way

  • @teel6060
    @teel6060 5 років тому +4

    Excellent video, concise and to the point without goofy nonsense and fluff. Well done!

    • @Chrominance87
      @Chrominance87 5 років тому

      Pex is manufactured with some UV resistance however, Pex was intended to be used indoors only.

  • @00HiGhGuY00
    @00HiGhGuY00 3 роки тому +8

    Zurn makes pex-b tubing that works with expansion fittings.

    • @FixthisCD
      @FixthisCD 3 роки тому

      I am having a hard time understanding that and I even looked at zurn's site. Always thought A was expansion, B crimp

    • @thefix2573
      @thefix2573 3 роки тому

      @@FixthisCD Zurn B can use them

  • @spyglass9er
    @spyglass9er 3 роки тому +2

    Interesting comment about bursting pressure vs freezing. I would think that flexibility in the PEX A is the answer to possible freezing, not absolute burst pressure of PEX B.

    • @jerrysmith9780
      @jerrysmith9780 3 роки тому +2

      Exactly what concerned me about this video.

    • @Sophia-lc9ow
      @Sophia-lc9ow 2 роки тому

      So does he mean that pex A would be more likely to burst as opposed to B?

  • @jeromesweet5047
    @jeromesweet5047 5 років тому +2

    I used to use pexA for crimping but then the suppliers stopped carrying it . Really was was softer and easier to work with than those damn rolls of pexB , especially in the colder temps. Its almost impossible to straighten out PexB below 40 degrees.

  • @areenalali
    @areenalali 6 років тому +3

    Regarding cross linking degree , I do agree with you that A has higher degree ,, but its not an advantage, as there are standards that governs the minimum cross linking degree to enable the pipe to do its function.
    Thanks

  • @naturestrail2296
    @naturestrail2296 5 років тому +13

    I'd like to see an actual freeze test of pex A vs B. The bursting pressure is lower but ice only expands so far and pex A is more forgiving upon expansion. So in a freeze situation I'm wandering if A would just expand where B might crack? Let's say if freezing water expands 9% but from what I understand can push 30,000 psi of force then stretchy pipe is better than strong pipe when neither can hold the force correct? Those are the actual figures of expansion from water to ice I've found so far. So wouldn't pex A be far better if the pipes froze?

    • @naturestrail2296
      @naturestrail2296 5 років тому +2

      @TerraTN if so I'd recommend using the same copper crimps as other pex which can be used as well on pex A. Metal shrinks as it gets colder so that should solve that

    • @frankgorgone4879
      @frankgorgone4879 5 років тому +3

      Matt Reisinger on UA-cam has a few great videos on these subjects. Check out his page

    • @frankgorgone4879
      @frankgorgone4879 5 років тому

      Brandon Bailey ua-cam.com/video/WMEbIxj4kRs/v-deo.html&feature=share

    • @frankgorgone4879
      @frankgorgone4879 5 років тому

      Sorry her is one of the right direct links ua-cam.com/video/fT2ftQ_ab-w/v-deo.html&feature=share

    • @waysaunut
      @waysaunut 5 років тому

      ua-cam.com/video/OOeBJ8mDr8Q/v-deo.html

  • @IggyDalrymple
    @IggyDalrymple 3 роки тому +1

    According to "Integrity Repiping" Pex B also has expansion fittings but he admits that it's stiffer and a bit more difficult to work with. In his video he does NOT seem to be using Pex A expansion fittings because he shows using a special expansion adapter head on a regular electric expander tool.

  • @RighttothePointDIY
    @RighttothePointDIY 4 роки тому +5

    Brilliant! Exactly what I needed to know in 4 minutes! Thanks.

  • @volbster2
    @volbster2 5 років тому +1

    I plumed my 3,000 sqft house with copper in 98', all the cons you mentioned about Pex B is nothing compared to working with copper. Cons with Copper: hand rotation cuts with pipe cutter, sanding each end, adding flux, heating just right, sticking solder in the joint, sniffing out leaks, hoping your house don't burn down, dealing with stiff straight tube that can not be bent, undoing solder joints, I had a burst water pipe from a freeze, wrong cut? Cha-Ching $$$ screwing up can be expensive. So I'm really looking forward to all the cons with Pex B on my next project.

  • @marito242
    @marito242 4 роки тому +3

    Other thing to consider is the cost of the crimping tool versus the expanding one, of course I talking about a battery one, you will hate the manual expanding one very early In to you day.

    • @dancampbell972
      @dancampbell972 4 роки тому +2

      Ya, but you don't have to got to the gym after day of expanding with a hand tool!

  • @starlee7680
    @starlee7680 4 роки тому

    Very professional introduction on PEXA and PEXB. Recently years PEXa is increasing , the PEXa pipe extrusion machinery seems available in more and more machinery manufacturers.

  • @Accumulator1
    @Accumulator1 2 роки тому

    Very informative fast facts without any slow chatter. Deciding if A or B for my DIY jobs. I like A with expansion fittings(less restrictive) & flexible pipe. I don't trust the Shark oring connectors so would not use. Chemical leaching on A is a concern. I don't understand what problems the less chemical bonding with B would be?

  • @casperwolf813
    @casperwolf813 4 роки тому +6

    Really good video. Straight to the point.

  • @danielbuckner2167
    @danielbuckner2167 2 роки тому

    "Up-on-'er" Bwahahahahaha!!! Damn... that was great. Best thing you've ever said kiddo.

  • @RKmndo
    @RKmndo Рік тому

    Also check out PE-RT and expansionable Zurn Pex B piping.
    PE-RT pipe is recyclable, and allegedly stands up to chlorine/chloramine.

  • @jaimedpcaus1
    @jaimedpcaus1 2 роки тому +2

    Very nice! So, all connection fittings can go on A or B Pex. Except for expansion fittings which can only go into Pex A. Did I get that correct?
    It's very critical to me about your mentioning of chemical leaching! I can only imagine greatly and bad things such as Cancers from getting chemicals onto a person's body after many years of getting showers...!

    • @irafair3015
      @irafair3015 2 роки тому +2

      As soon as I heard chemical leaching I drew back a bit. Now I'm not so sure I want to use PEX just for that reason alone.

    • @mandyt8178
      @mandyt8178 Рік тому

      I cancelled a repipe job once I learned about the chemical leaching in PEX A. We are replacing copper pipes with lead solder and no point in replacing with more troublesome pipes. Have any scientific studies been done?

  • @mwilliamson3989
    @mwilliamson3989 4 місяці тому

    Thanks so much for this information I really appreciate it.

  • @koontoonsproductions6700
    @koontoonsproductions6700 Рік тому

    Yo, thank you, my guy! got right to the point and answered every question I had. Dayum Boyeee!!

  • @emartinez6584
    @emartinez6584 5 років тому +3

    THANK YOU I LEARNED A LOT WATCHING THIS .

  • @jenniferhamm3118
    @jenniferhamm3118 5 років тому +1

    Thanks so much... I wasn't sure which pex was installed in my house and as I tinker, I've been using Nibco from Menards but was concerned about whether I was using the right fittings or not. Good to know you can use the same fittings regardless of the A or B originally used.

  • @HBSuccess
    @HBSuccess 6 років тому +7

    PEX A is "Real PEX" in my book and many pro installers who started using it for radiant jobs in the '80's... this is the stuff that can withstand slabs jutting, freeze/thaw, concrete trucks running over it, etc. etc. Expensive and well worth it if you're installing something you can't easily access later. To me, the current "Big box" craze of homeowners running PEX B all over the place with dozens of crimp/barb fittings is a future disaster waiting to happen. Every one of those crimp sleeves represents a potential leak IMO. I hope I'm wrong, but history repeats LOL. Furthermore there are now concerns about PEX B supporting all kinds of microbial growth on the inside of the pipe. Another time-bomb waiting to bite everyone IMO. If you're going to run PEX B for domestic plumbing then use a 'home run" system and manifold, and avoid as many fittings as you can. Just my .02. Me - I'd probably still run copper.

  • @gsftom
    @gsftom 2 роки тому

    Excellent video. Great info w zero bs.

  • @Grejegando
    @Grejegando Рік тому

    I'm not a fan of Type A, not only is it more expensive but sounds like Lego to me. Also there are no long-term studies on the grip between the expanded pipe/ring and the pipe itself and how it is affected by prolonged heat. If a heat gun can have that immediate effect of the pipe (I realize we are talking about high heat) then heat for longer periods might also have an effect. Those pipes are approved for hot water usage so anything could go wrong there over time.
    The only advantages I see of a Pex A piping system are flexibility especially when working in narrow spaces and the lower pressure drop due to larger fittings.

  • @realdogful
    @realdogful 2 роки тому

    Great presentation. Clear, concise and to the point.

  • @tommyranger1
    @tommyranger1 3 роки тому

    Which would you use for 1) connection to lawn irrigation from well. 2) house plumbing with Culligan purification system.??

  • @johnells9895
    @johnells9895 Рік тому

    PEX is being considered more now for home made swimming pool solar heating. Which best resists higher concentrations of Chlorine and other chemicals not found in City water?

  • @byronewhite
    @byronewhite Рік тому

    Expansion fittings are now available for Zurn Pex B

  • @allansayers6149
    @allansayers6149 4 роки тому +5

    In all of the years i've been around these 2 products,I have never seen pex A have a hairline split down the side, unlike pex B.

  • @JUDALATION
    @JUDALATION Рік тому

    one major benefit of pex A is the fittings for pex A have a larger radius for water flow...

  • @classicbikerx3588
    @classicbikerx3588 Рік тому

    Answered my question in the first minute, thank you!

  • @jamescalifornia2964
    @jamescalifornia2964 3 роки тому +2

    I like the colored one better. Feel happy with colors while you work 👌😁

  • @malcurtis3028
    @malcurtis3028 4 роки тому +1

    Which is better for underground installation?

  • @DCS026
    @DCS026 4 роки тому +1

    Thank you for just getting to the point.

    • @PEXUniverse
      @PEXUniverse  4 роки тому +1

      I'm glad you enjoyed the video!

  • @erowley462
    @erowley462 5 років тому +14

    My bad, I thought this vid was about PEZ....carry on.

  • @bennycohen4777
    @bennycohen4777 3 роки тому

    PEX-a is harder to manufacture then PEX-b because the crosslinking process is done on the production line, thus the extrusion process is much slower the PEX-b or PEX-c, because you have to allow the needed time for the peroxide doing the crosslinking process under high pressure and heat to take place whereas PEX-b or PEX-c the crosslinking is done after the pipe is made either in steam of gamma radiation treatment. PEX-a is done in a "starving fed system" whereas PEX-b and PEX-c are flood fed system.

  • @user-bj4lp3fr1o
    @user-bj4lp3fr1o 2 роки тому

    Zurn a manufacturer of pex b says you can use expansion fittings.

  • @ronh9384
    @ronh9384 5 років тому +4

    I like Pex A better and have the tools for the expansion fittings but I did not know about the leaching issues with pex a which concerns me. It would be nice if someone would come out with a version of pex b that allows me to use my expansion tool with either Uponor or Souix expansion collars.

    • @nc3826
      @nc3826 4 роки тому

      It would be nice if someone would come out with a version of PEX A with a copper liner for portable water lines... Since they make PEX-Al-PEX tubing thats designed to be used in heating application, so a PEX-Cu is do able...until then use copper for portable water lines...

    • @stephenallred8629
      @stephenallred8629 3 роки тому +2

      Recently watched a video by Integrity Plumbing claiming that Pex B made by Zurn is expandable and therefore compatible with Uponor fittings.

  • @KrazyKajun602
    @KrazyKajun602 Рік тому

    what is the difference between Pex pipe and black polyethylene and also which is better to use for underground use to outdoor faucets?

  • @MarkMinistries
    @MarkMinistries Місяць тому

    I want to make sure I bought the correct pipe how do I know if my pipe is pex B?

  • @ronh9384
    @ronh9384 5 років тому +1

    I found your website last night and the UA-cam channel today. You should mention the UA-cam channel somewhere in the top of the page header on the website. Some really good info on the website and UA-cam channel. And a good source for supplies.
    Ron

  • @BornToFly4031
    @BornToFly4031 4 роки тому +2

    The word temperature is not spelled correctly...good info though, thanks.

  • @KrazyKajun602
    @KrazyKajun602 3 роки тому +3

    Can you tell me then why is Zurn claiming there Pex-B can be used with expansion ?

    • @michaelwright1602
      @michaelwright1602 3 роки тому

      It can, it is pretty much like Pex A, expansion and all, including the battery operated tools, though with different heads than what comes with the Uponor tools. But, you can use the uponor expansion tool with the Zurn. Now, try to find Zurn Pex, I cannot find it, sticking with Uponor Pex A.

  • @rugslug6024
    @rugslug6024 4 роки тому +6

    I’ve have used copper. Cpvc. Pex A and B they all have there limitations
    Don’t be fooled by Advertising if installed right. They will all last a long time

    • @beerbeforebreakfast
      @beerbeforebreakfast 4 роки тому

      Just dont put cpvc where it can be jostled at all.....CRACK....SPEWWWW...🙀🙀🙀

  • @wallacemedeiros9980
    @wallacemedeiros9980 4 роки тому

    Very informative and straight to the key points. Great video and thank you!

  • @Adam666i
    @Adam666i 2 роки тому

    Pex B connectors have very tiny inside diameters decreasing the water flow pressure. Expanding Pex A connectors don't cause dimension changes issue

  • @zigarooSJunk
    @zigarooSJunk Рік тому

    i waa wondering, i saw in store 3/4” PEX pipe which were white and another one which was white but the interior was black. what’s the difference? does it use same crimping ring….etc.

  • @asasmith5639
    @asasmith5639 4 роки тому +1

    Excellent information. Thank you..

  • @KM-rw4td
    @KM-rw4td 4 роки тому +1

    Thanks for the information
    Which is better for outdoor freezing weather?

    • @PEXUniverse
      @PEXUniverse  4 роки тому

      While all three PEX A, B, and C are able to withstand the cold, PEX A and B are the most commonly used. PEX C is not as durable as the other two but with either choice A or B they will work great.

  • @radondar9230
    @radondar9230 3 роки тому +1

    Another downside to pex b is that the fittings go inside the pipe - which constricts the water flow.

  • @dean7324
    @dean7324 5 років тому

    Great videos. Concise and to the point. Thank you.

  • @donniemorris9743
    @donniemorris9743 4 роки тому +1

    What ever you do don't use it outside where sun will be hitting on it . It will weather rot quick. l learned that the hard way . It is a inside tubing only.

  • @Jgriffin0808081
    @Jgriffin0808081 5 років тому +17

    I thought the red is the exact same as blue, just different colors to identify hot or cold domestic water, and that orange pex is for radiant heating...

    • @frankgorgone4879
      @frankgorgone4879 5 років тому +8

      Jgriffin0808081 you are correct about the red, blue and white pex.
      The orange is oxygen Barrier pex used in heating it keeps the oxygen out of the system which will deteriorate your heating system if it can migrate through the pipe.

  • @christinamarina6008
    @christinamarina6008 4 роки тому

    Extremely informative. I wandered here trying to figure out how to tee a pex pipe, and figured I'd better know the difference before I got started on my project (honestly didn't even know there were two different kinds til this video. Starting from scratch here). Thank you!

  • @nwlady1844
    @nwlady1844 5 років тому +2

    Thanks! great concise info

  • @briha3142
    @briha3142 2 роки тому

    I’ve heard that Zurn also makes a superior PEX A and B. But you didn’t mention that name brand. Is it not available where you are at?

  • @ricdonato4328
    @ricdonato4328 5 років тому

    Very good video, now I understand the difference. We installed white PEX from Home Depot, they said it is PEX-B. Yes, it has a memory, our 25 foot coil was a bugger-bear working with. To allow us to unroll it we used our muscles and a heat gun, it took a long time getting it straight enough for our eighteen foot run, then used two Sharkbite connectors. Because of the PEX-B memory, at present my thinking is I will not again use PEX-B.
    At 1:17, the graphic reads “pressure and tepmerature...”, it should read “...temperature...”.

    • @VC-Toronto
      @VC-Toronto 5 років тому

      It's sometimes not easy to find Pex-A at the consumer level, as it's often only stocked at plumbing supply stores, but now with all the online options, has become easier to source out. The installation tool is not cheap, but may be available to rent.

  • @hj8607
    @hj8607 4 роки тому +1

    A few incomplete comment bits . Pex-a Will burst at a lower pressure (though higher than you would ever allow in home plumbing ) HOWEVER Pex -a will survive the expansion of a freeze much more likely than Pex-b . (you can't expand Pex-b to fit expansion fitting that Pex-a is primarily used with .)

    • @pterafirma
      @pterafirma 3 роки тому

      That sounds intuitively correct, but do you have any empirical data about freeze performance of A-vs-B?

    • @hj8607
      @hj8607 3 роки тому +1

      @@pterafirma The plastic itself is not going to crumble when frozen so the only force is the expansion of the freezing water . And water expansion will come no where near the expansion force of huge stretch that happens in putting pex A onto a fitting . (for sure Pex A exceeds Pex B and both far exceed the burst point of copper). (no empirical evidence but I am sure some one has some)

  • @jeffmucha
    @jeffmucha 4 роки тому +7

    Where did you get your data that Pex-A leaches more chemicals than Pex-B. Could you post a reference please?

  • @boots7859
    @boots7859 4 роки тому

    Great video, short, too the point, no useless visual or grating musical distractions.
    Also, you look like a young Kai from Lexx, and not sure why the better cross-linking of Pex-A is of any use since overall Pex-B seems to have superior ratings on things like burst pressure. PS- Can you straighten out the Pex-B with a little heat from a heat-gun?

    • @thefix2573
      @thefix2573 3 роки тому

      no it will melt. Collapse further.

  • @fun782house
    @fun782house 5 років тому +7

    thank you , way more help ! then the none helping LOWES employees

  • @Lemming32
    @Lemming32 5 років тому +1

    My plastic Pex manifold is bogus. The plastic fittings get warm from the hot water and leak. Any advice? Female brass fittings on my plastic manifold OK?

  • @livinglifemyway7349
    @livinglifemyway7349 2 роки тому

    So can I use pex A with standard pex fitings and can I use Pex A with CINCH rings/ clamps not using the expanding tool but just slipping on the pex A on the fitting and use a cinch clamp? thanks

  • @dr.j9080
    @dr.j9080 2 роки тому +1

    I have not used pex so I have been doing some research. I initially was sold on Pex A but have come across some videos that make me hesitant to go with A. One thing, Pex A cannot be used with the cool Viega manifold system. Another reason, some of the fixtures like Delta or Kohler do not readily accept that expansion connections. Is there a work around to these problems?

    • @johncaper68
      @johncaper68 2 роки тому

      You should be able to use pex a or b on the manifold since it's a compression connection. As for fixtures there is a 1/2" pex x 3/8 compression fitting. Take the compression nut and ring off and the supply line screws right to the fitting. You can get these for pex a or b, expansion, crimp, compression etc

  • @brianpiersol9412
    @brianpiersol9412 8 місяців тому

    Chlorinated water effects on A & B piping? discuss that too

  • @gogogeegee76
    @gogogeegee76 3 роки тому

    Dear sir,
    Would you agree that PexA is better in houses that suffer frost attacks yearly, ie that it is easier for pex A to 'bloat' due to ice expansion and then move back to its original size?

  • @Kirtirajsardesai
    @Kirtirajsardesai 2 роки тому

    What if I use sharkbite push connector on a pex-a will it reduce the pressure ?

  • @dontaenoel4774
    @dontaenoel4774 4 роки тому +1

    Do you have any details on PE-RT piping?

  • @jeffw8057
    @jeffw8057 4 роки тому

    Great and concise summary. Thanks!