Troubleshooting a 5 HP Submersible Irrigation Pump. McDonald Motor Gould Pump Combo.

Поділитися
Вставка
  • Опубліковано 8 вер 2024
  • Troubleshooting and diagnosing a 5 horse power submersible irrigation pump that was not performing. See some oscilloscope data at the end of the video.
    I didn't have a camera with me for the onsite diagnosis, but that would have been great footage to see the lab scope data before and after. I just had an amp clamp with me when I pulled the pump, but would have been nice to see exactly what was going on.
    The failure was due to a combination of minor issues that should have been corrected. The pump and motor was fine after a good service. Performance was restored by correcting the steps shown in the video.

КОМЕНТАРІ • 2

  • @gallowaylights
    @gallowaylights Рік тому +1

    That was a quick fix, not! Great detail 😅

    • @gorgeoutdoors
      @gorgeoutdoors  Рік тому +1

      The more a guy looks, the more issues he found! The pump is kicking ass, its a performer. Runs 25 rotors over 500 feet away.