COMMERCIAL ELECTRICAL MATERIALS Apprentice Electricians Should Know

Поділитися
Вставка
  • Опубліковано 21 січ 2025

КОМЕНТАРІ • 539

  • @gregorall9779
    @gregorall9779 2 роки тому +199

    I'm retired now after 35 years in the trade, but something that I learned early on is depending where or who you're working for, you're going to hear all of these items referred to by different names. Great video for the individual just getting into the commercial side of the trade and a portion of them being used in industrial. Remember, it's not a competition to see who's better, we're all in the same trade so instead of tearing each other down, build each other up.

    • @Son_scorpio
      @Son_scorpio Рік тому +3

      That's true , I've got started in the trade I know some of them in different name .

    • @venividivici4253
      @venividivici4253 Рік тому +2

      You retired too early. Keep going :)

    • @gregorall9779
      @gregorall9779 Рік тому +8

      @venividivici4253 I'm enjoying my new job of being retired way too much!! If I had known it was going to be this fun, I would've done this earlier.

    • @bryanesquivel8784
      @bryanesquivel8784 Рік тому +2

      Your cool asf

    • @anibal5845
      @anibal5845 9 місяців тому +1

      Amen brother

  • @SparkyChannel
    @SparkyChannel 4 роки тому +109

    Hi Dustin. This is Bill from Sparky Channel. I want to sincerely thank you for mentioning the new Sparky Channel on one of your videos/instagram. For those who don't know, the original Sparky Channel got hacked and the hacker deleted my 934 videos and I lost my 182K subscribers. I have started a new Sparky Channel which now has 62 videos and 2600 subscribers. Some of the new Sparky Channel subscribers came from your channel after your announcement so I want to really thank you for that! Best wishes!

    • @mavenfeliciano1710
      @mavenfeliciano1710 4 роки тому +1

      Sparky Channel I haven’t seen anything recently by you but I thought it was because I only subscribed in my other account.
      Between the two of you I learn most of my electrical. 👍
      Sorry for your hack, and resubed. ✅

    • @farmerdave7965
      @farmerdave7965 4 роки тому +1

      Bill, thanks for the info. I was wondering where all the sparky channel videos went.

    • @aaron74
      @aaron74 4 роки тому

      What? That's horrible... No wonder your videos have disappeared from my UA-cam recommendations. MAKE A SUPER TOUGH PASSWORD!!!!!

    • @luisLopez-uz3mv
      @luisLopez-uz3mv 4 роки тому +2

      New subscriber sparky

    • @connorverreault2856
      @connorverreault2856 4 роки тому

      wow sparky, very impressed with your video out put and quality. I feel so awful for you about your channel. I hope you can someday recover from that.

  • @JayeeFromLA
    @JayeeFromLA 2 роки тому +60

    Not sure why you decided to start doing these videos but I’m very grateful. As a visual learner it took months for this stuff to click reading about it but going through these videos cuts that process tremendously. Keep up the great content!

  • @lukasvilla2657
    @lukasvilla2657 2 роки тому +14

    Tomorrow is my first day with an electrical company. I'm super nervous. I've never done this kind of work. They said I will be doing pre-fab for 6 months to a year then I will be out in the field doing 3 phase work. The cool thing is they are paying for my apprenticeship school after I'm there 60 days. I bought a bunch of tools yesterday from harbor freight because that's all I can afford. I subbed to your channel. Good information! Thanks. I'm going to just take it day by day and not get too ahead of myself. I will learn as I go.

    • @anhtuanestevez5427
      @anhtuanestevez5427 4 місяці тому +3

      Hey how’s it going now I’d love to know if you’re still doing it? I just started about a week ago from know nothing at all about anything I’m watching as videos as I go and some good help at the job

    • @lukasvilla2657
      @lukasvilla2657 4 місяці тому

      @@anhtuanestevez5427 hey how's it going? It's going well! I started off doing residential for a few months then I got an offer from a friend to do commercial work. I got a much bigger pay increase and I enjoy it more. It wasn't as hard as I thought it would be. They taught me alot and didn't throw me into the fire right away. I worked side by side with someone for a whole year and learned alot. Now I can do rough in, trims, install gear, bend pipe, pull wire, terminate panels, wire disconnects, etc. I also started at $14/hr in residential and as a 2nd year apprentice in commercial I currently make $21/hr which isn't bad for someone only doing it 2 years. Good luck!

    • @andrearosales5980
      @andrearosales5980 2 місяці тому

      Hey how's it going?​@@anhtuanestevez5427

    • @mesohunt704
      @mesohunt704 Місяць тому

      I’m curious if the job worked out for you? Im a bit over 3 years in the trade and love it more then I ever thought was possible for a job. Next week I’m kinda getting thrown in the fire to show I’m capeable of being a lead in the future. My lead is gone all week for thanksgiving and I’ll be by myself 3 days roughing in a 4K sqft house. It’s about halfway done so still have a decent bit to go. Hopefully it goes well but I’m sure some dumb shit will happen. The homeowners/builder come with 400 change orders they want done ASAP.

  • @Ulysses_21
    @Ulysses_21 4 роки тому +148

    Here in Michigan, we call the "1900 box" a four-square box. Four-square deep, or shallow for the different varieties.

    • @Ricky-iy9cx
      @Ricky-iy9cx 4 роки тому +17

      4 square deep, 4 square shallow

    • @trezzer53
      @trezzer53 4 роки тому +7

      It’s called a 4x4 where I’m at

    • @liveoak227
      @liveoak227 4 роки тому +8

      Yeah 4x4 where I'm at, and I'm assuming when he says 2100 box hes talking about the 4x4'11 boxes

    • @Swflec
      @Swflec 4 роки тому +4

      Same here in FL

    • @Swflec
      @Swflec 4 роки тому +2

      4 square, 4x4

  • @karenrachum4319
    @karenrachum4319 4 роки тому +41

    I really like your videos, in particular these two about the different devices and connectors. I am a Electrical Department supervisor at a Home Depot, and trying to be more knowledgeable about the products that my customers need to buy. Keep up the great work and thanks again from a different sort of industry professional!!

  • @arthouston7361
    @arthouston7361 4 роки тому +62

    1900 was the original part number for the 4" box sold by Bossert in the previous century.

    • @docferringer
      @docferringer 3 роки тому +4

      Thanks for that bit of trivia! I was expecting it to be the size in cubic millimeters since the metric system has been creeping in everywhere. Close, but no cigar: 1900mm = 74.8 inches vs. 4" x4 "x4" = 64 inches.

    • @24vignettes94
      @24vignettes94 3 роки тому +1

      That’s interesting. When I was in the field, we never referred to them as a 1900 or 2100. I moved to another state and realized how different the nomenclature is area to area.

    • @gerdberg4188
      @gerdberg4188 3 роки тому +1

      In NH I never heard either term in 38 years

    • @24vignettes94
      @24vignettes94 3 роки тому

      @@gerdberg4188 made it to Mt Washington a few months ago. That’s a pretty area up there

    • @barrettready1713
      @barrettready1713 2 роки тому

      I didn't know the company, but I did know it was a product number

  • @themichhiker2104
    @themichhiker2104 4 роки тому +215

    Went from "my dudes" to "my friends" to " my friend," next will be " to whom it may concern." lol

  • @ExtremeWassabi
    @ExtremeWassabi 4 роки тому +11

    I have like nearly 2-3 years experience (as a helper) but its very scattered with a lot of different contractors so your videos are a huge help. Nice to catch up on stuff I have not touched in 6 months! Greatly appreciated, thanks! In NYC its either you attempt to try to get into a union which takes years or you try your luck working for private companies that sometimes do not even hold an electrical license under their name.... Lets just say credible info is scattered -- thats if you even get coworkers that speak english.

    • @corvettefever360
      @corvettefever360 3 роки тому

      Isn't this the truth. I've been doing this for almost 20 years, & i do work in the boro's but mostly on Long Island, & it's pretty much the same thing.

    • @BerettaMLH
      @BerettaMLH 2 роки тому

      No lies detected here

    • @balance555
      @balance555 3 місяці тому +1

      What is a helper? Can't blue color trades go back to traditional terms? Your an apprentice if your learning the trade starting out. How cheap has the world got.

    • @johnsonT1798
      @johnsonT1798 Місяць тому

      As someone going through the apprenticeship after a few years of rat companies working the dog shit out of me with no chance of regular raises or health insurance, I’ll say the apprenticeship route has been an amazing change. The exposure to the different environments of electrical work from industrial to commercial and some residential has been extremely helpful in learning the trade. And the regular pay raises and opportunities for travel work are huge for me

  • @eloy.97
    @eloy.97 4 роки тому +26

    Hell yea this is my first week in commercial electric, i needed this !

    • @Steve_mos8541
      @Steve_mos8541 3 роки тому +2

      iver been apprentice for shit...damn near umm 6 weeks!

    • @Bonavire
      @Bonavire 3 роки тому

      Congrats! I've been an apprentice seven months so far, how's the trade treating you?

    • @Steve_mos8541
      @Steve_mos8541 3 роки тому +2

      @B M fine i guess, been in 3 Unions as a young man im 55, havent been in one since i left IL in 2002, one of my unions was taken over by the Justice dept. it was so corrupt, no man should be Forced, to Pay or Join ANY organization...JUST to work..

    • @Steve_mos8541
      @Steve_mos8541 3 роки тому +1

      @@Bonavire well i got very Lucky...finally i guess, im prob too old, but i do like it a lot , SO much to learn and always punch out having DONE something, etc.

  • @WorstElectrician
    @WorstElectrician 4 роки тому +31

    This is so convenient ,i just got hired today and our company is working on a commercial site

    • @Automationacademytv
      @Automationacademytv 4 роки тому +2

      Nice one

    • @WorstElectrician
      @WorstElectrician 4 роки тому +5

      Tom Garbo Thanks,i’m still in trade school so i’m gonna make all the mistakes i can while i’m still in school.My boss told me that Florida doesn’t have a lot of industrial sites,so we’re not gonna he bending much pipe at all but it’s still good to learn it.Since i’m the youngest guy at the job (18) he told me to expect to get teased a lot by the older guys Lol

    • @smackflack5771
      @smackflack5771 4 роки тому

      Ummm. U sweep the jobsite. This wont help

    • @WorstElectrician
      @WorstElectrician 4 роки тому +3

      Tom Garbo i got financial aid so i used that to buy a code book.I also purchased an UGLYs book last week.Ill definitely keep that in mind about the harness Lol

    • @ashleydecker2687
      @ashleydecker2687 4 роки тому

      You'll be carrying alot of conduit and alot of item chasing lol

  • @Kusv583
    @Kusv583 Місяць тому

    Thanks for these videos to basic electrical components. I am started a new job next week with a local electrical supply company just working in their warehouse picking orders and delivering them to contractors. This has helped me greatly in becoming familiar with some of the common parts. 😊

  • @92dboatright
    @92dboatright 4 роки тому +22

    Through out my work and schooling I had never heard it called a 1900 box. Always been a 4 square or 4 square deep. Learn something new every day

    • @Jpeveto44
      @Jpeveto44 4 роки тому

      Southeast Texas here, we always call them 1900 or 2100 boxes but also know them as 4 square because we get a lot of travelers here.
      Industrial Electrician/Instrument Tech/Analyzer Tech of 25 years.

    • @cameronkirkland4168
      @cameronkirkland4168 4 роки тому +1

      I was wondering if I was the only one who never heard the name 1900😂😂

    • @crazyrmj2580
      @crazyrmj2580 3 роки тому

      I always thought it was called junction box but when I entered the field it was either 4x4 by box or 1900

    • @nick68511
      @nick68511 3 роки тому

      Same here in Ohio. At least in my area

    • @LucasGresham610
      @LucasGresham610 3 роки тому

      Always kind cool to hear what guys call things from definitely parts of the country. around here we call them 4x4 combo deep.

  • @wesboothe6507
    @wesboothe6507 4 роки тому +5

    Dustin, please do more of these on commercial electrician work. Always enjoy your videos, thanks man!

  • @kylehurley9103
    @kylehurley9103 4 роки тому +4

    I love your content by the way. I was just given my first apprentice, and I told him to check out your videos in his spare time!

  • @edgerrr
    @edgerrr 4 роки тому +16

    The 'mc' in mc cable stands for 'metal clad'.

  • @zfrenchy1716
    @zfrenchy1716 3 роки тому +1

    I am not an electrician, just a fire alarm guy working with conduit sometime.
    6:42
    just one question, why blank cover has marking says "inside box side" ? For me both side look the same.

  • @mikenormandy9250
    @mikenormandy9250 4 роки тому +5

    Would love another video of this as you could def cover Conduit Bodies and anything else you missed like wire pulling materials like bird cages, baskets, fingers, bullets, sister hooks, etc! Great video!

  • @cristobalmorales5552
    @cristobalmorales5552 4 роки тому +2

    Thank you for explaining and teaching us about these commercial materials. This coming Monday is my first day of work in commercial electricity and I found this very helpful. !! Keep up the good work!!

    • @adriangamino3642
      @adriangamino3642 4 роки тому +2

      How did it go!??? I also start in a few days and I am excited!

  • @2inchfromtheground
    @2inchfromtheground 4 роки тому +6

    1:21 in my experience, city, county and state, hiding a junction box is against code.
    I know that's not what he meant, but some people might take that wrong

    • @Mr.Sparks.173
      @Mr.Sparks.173 3 роки тому

      In Canada a junction box just needs to remain accessible. As long as an electrician can get to it and service them, its good.
      That means hiding them in an attic or crawlspace is a-ok by code. Same with tucking them up into drop ceilings.

  • @Mr_Gray_1995
    @Mr_Gray_1995 Рік тому

    I’m just getting into it. Thank you for the help. I’m taking my own notes but videos like these are great for newcomers and those who would like quick refreshers.

  • @ramonnote1997
    @ramonnote1997 4 роки тому +2

    Excellent video for people learning electrical work and Great UA-cam channel Att (Rivera Electrical service LLC) from Puerto Rico 👍🏻

  • @gregorymartinez8294
    @gregorymartinez8294 3 роки тому +1

    Dope hat!! I work in commercial but I do EMS, low voltage controls for grocery remodels but I deal a lot with these materials. I have to pend pipe and your videos are amazing. Appreciate what you do

  • @kristopherleslie8343
    @kristopherleslie8343 9 місяців тому

    I’m a low voltage guy and absolutely needed this. Thank you ❤❤

  • @rickalejandro7720
    @rickalejandro7720 4 роки тому +11

    Not to take anything away from you brother your awesome this is just for the apprentices. I'm a 9 yr commercial journeyman electrician out of San Antonio Tx. Great video I watch all your content, The 1900 boxes or 2100 refer to cubic inches in the code book, used for the calculation of the box fill.

  • @olegs79
    @olegs79 4 роки тому

    8:00
    That box looks very busy.
    We use the grey boxes with the 5/8 inch and 3/4 knockouts for bx and 3/4 pipe. Anything bigger and you can use a knockout for larger sizes. You probably won't have that many pipes or bx collecting in one box. Unless it's a pull box around a panel.

  • @racheleast688
    @racheleast688 3 роки тому +1

    Next size up from 1900 is the 11-B. There's also an 8-B which before I learned what it was I called it an octobox.
    Spring nuts can be ordered without a spring. They are called strut nuts.

  • @outragedpi3
    @outragedpi3 3 роки тому

    For those north of the border.
    4x4 box, Bullnose receptacle cover (decora/standard), mud ring, steel stud box, gang box (device box), different from a cut in box, L16/Twins, AC90 (where is the spool?), Connector/coupling/liquid(or concrete tight), 4x4 blank cover, 12x12 JB (would never need a box that big for residential, useless in commercial), relay, contactor, spring nuts/spring nuts that someone broke the spring off, unistrut (deep/shallow), EMT/Rigid Conduit, Flex

  • @vgmijpn8ball
    @vgmijpn8ball Рік тому

    Thanks. I am an engineer who works in maintenance of PLCs and such, and get tossed facilities electrical work sometimes and just have to go thru piles of random electrical to figure out what to use, now I have a better idea.

  • @sstanek7555.5
    @sstanek7555.5 4 роки тому +5

    Gonna get a hoodie for Christmas this guy is good at explaining, I've done that before...

  • @kiwies38
    @kiwies38 4 роки тому +4

    it's called a 1900 box because back in the day it's catalog number was 1900. At least that's the story here in Chicago. As far as those other materials, the trade names here are so different that I just had to turn the video off because I didn't want to confuse them.

    • @aaron74
      @aaron74 4 роки тому

      That's what I've heard too.

  • @andrewgauer3572
    @andrewgauer3572 2 роки тому +2

    This guy is so good at explaining things.

  • @joew4202
    @joew4202 2 роки тому

    9:39 you say add logic to analog circuit. Relays only handle digital circuits. Digital = on/off. Am I wrong ?

  • @illestofdemall13
    @illestofdemall13 4 роки тому +17

    1900 was the original part number for the 4x4 box.

  • @jaredthompson1522
    @jaredthompson1522 4 роки тому +2

    Could you maybe do a video about magnetic and manual motor starters with ladder diagrams? I’m doing motor controls in school and having a hard time understand ladder diagrams for motor starts. Like how do you figure out where auxiliary contacts, overload contacts ect are on diagrams and motor starters. Love your content man. Thanks.

    • @Volcker1929
      @Volcker1929 4 роки тому +1

      jared thompson UA-camr "Watch Wes Work" video called "CNC Machine Stuck in Emergency Stop" will help you out.

  • @METALKILLSemosNpunks
    @METALKILLSemosNpunks 3 роки тому +1

    This is pretty much all we use in NYC. Whether it’s skyscraper or a townhouse.

    • @XLGaming
      @XLGaming 2 роки тому

      same near the Chicago area.

  • @joejoe6949
    @joejoe6949 4 роки тому +2

    Try this use a 3/4 mud ring on 5/8 drywall best fit.

  • @rapsnack9329
    @rapsnack9329 2 роки тому

    I been working in this company for around 2 months and your equipment look way better than what I’m using. Like those single connectors and doble gang connectors I’ve never seen

  • @adolfodibiasio9235
    @adolfodibiasio9235 4 роки тому +1

    Hi Dustin, not sure if you have already but I could not find a video on single phase vs 3 phase. Thank you. Keep up the great work!!!

    • @dallas5374
      @dallas5374 4 роки тому

      Adolfo DiBiasio hire a professional.

  • @dharokpwnage
    @dharokpwnage 4 роки тому +12

    Another name that some people call flex by is “greenfield” especially in and around Chicago area.

    • @dharokpwnage
      @dharokpwnage 4 роки тому +1

      Another thing is people might call the industrial covers “garvins”

    • @racheleast688
      @racheleast688 3 роки тому +2

      It's greenfield on the east coast too.

    • @boblang5829
      @boblang5829 3 роки тому

      it's greenfield if it has no wire in it. MC has wire in it.

  • @inve
    @inve 2 роки тому

    As someone who is going to be running the MC cable (but not connecting to the fuse box) throughout my place, I appreciate your videos; thank you! Due to our location, companies demand huge money, and many use interns to run the cabling at $150/hr! Of course, the interns stop watches videos, plays games, questioning everything, calling friends, etc. and I refuse to pay $10,000 to run MC cable! This helps me understand the lingo better, especially when ordering or talking with my inspector. Don't worry interns, there is still enough work for you in the future, and growth isn't stopping any time soon.

    • @Bapuji42
      @Bapuji42 Рік тому +1

      wtf I get paid $22/hr to run MC

    • @inve
      @inve Рік тому

      @@Bapuji42 are you an intern or electrician?

    • @Bapuji42
      @Bapuji42 Рік тому

      @@inve lol apprentice obviously
      What's an intern?

    • @inve
      @inve Рік тому

      @@Bapuji42 haha, right! Sorry about that.
      It’s common practice for companies/firms to bill there apprentices and interns out at near full rates. Law firms do this all the time, so do plumbing and electrical companies.
      Sad they don’t pay you more, considering what they charge.

  • @FrezoreR
    @FrezoreR 8 місяців тому

    I love how comprehensive this video is!

  • @keithgrimsleeper978
    @keithgrimsleeper978 4 роки тому +2

    Love your videos trying to get into electrical right now. Definitely teaching me alot.

  • @arthouston7361
    @arthouston7361 4 роки тому +25

    Important note about contactors: the ones used in HVAC equipment are "definite purpose" contactors. You CANNOT use them for a different purpose, such as controlling lighting in a store. Contactors for lighting are MUCH more expensive, and are listed and approved for the purpose. Definite purpose contactors have a definite purpose that is NOT lighting a store. Make sure that any contactor you install is listed for the purpose. I'm just sayin'.....

    • @Tennesseememphis
      @Tennesseememphis 2 роки тому

      4 inch square memphis tn

    • @richt5986
      @richt5986 Рік тому

      You could use any contact anywhere as long as the amps is what is rated for the contactor.

    • @richt5986
      @richt5986 Рік тому

      I do lighting controls with contactors that are only meant for 12 V and I have other lighting contactors That are rated for 2hundred amps at 480v

    • @arthouston7361
      @arthouston7361 Рік тому

      @@richt5986 Actually, no, it is against the national electrical code to use anything except an approved contactor for lighting. You cannot use an HVAC “definite purpose contactor,” which is why I mentioned that. The difference in cost between a definite purpose contactor and one that is listed for use as a lighting contactor is about 10 times.

    • @richt5986
      @richt5986 Рік тому

      @Art Houston sorry not the point. I may have not explained better. You can use any contactor for whatever as long as it is rated correctly by the amps and volts

  • @travislmcdonald
    @travislmcdonald 3 роки тому

    I work mostly in refineries. We use a bunch of strut and spring nuts. Most of the time we rip the spring off the spring nut.

  • @XLGaming
    @XLGaming 2 роки тому

    Something weird, my house is wired with EMT and 1900 boxes with mud rings. I don't know why that's code in my area, but it is. I honestly hate it because if I ever want to add an outlet or something, I have to run conduit and use octagon boxes or 1900 boxes! Plastic boxes and Romex isn't allowed here! There's even industrial covers in my basement where there isn't drywall!
    Something else that's weird is how they wired the house.
    There is one 15 amp circuit that supplies power to almost all the lights on the main floor, outlets in the living room, outdoor outlets, and lights in the back yard. That seems like a lot of devices for a single 15-amp circuit.
    Theres also a single outlet in the master bedroom that is on the same 20-amp circuit as the bathroom outlets. The rest are tied with the lights on a 15-amp circuit.
    If that's not weird enough, the garage outlet is on a 15-amp circuit with the outdoor lights and the laundry room lights. i don't understand why they used a 20-amp circuit for one outlet next to the breaker panel, but used a 15-amp circuit for the garage, where you have high-power tools!
    Not to mention, 2 separate bedrooms share a circuit, and the office shares the upstairs hallway circuit.
    Even my bathrooms all share one circuit for the outlets, and another for all the lights.
    TLDR: My house is wired weird!

  •  4 роки тому +1

    1900 is an old catalog number. 4 square in the south. I loved working in DC. More so than in the south.

    • @racheleast688
      @racheleast688 3 роки тому

      Except parking is a pain. I've been in and out of DC, but mostly the NoVA area.

  • @djscrizzle
    @djscrizzle 2 роки тому

    Not to be a fly in the ointment, but there's PVC coated rigid conduit, called Rob Roy in the field. Also, threadless connectors can be gotten for type RMC conduit, so you're not threading it.

  • @BudoThePaladin
    @BudoThePaladin 3 місяці тому

    I'm only 3 years into the trade so far, but personally I prefer using the type of MC connectors that use a nut and tighten with two screws whenever possible over a snap in connector, they're easier to install.
    Edit: forgot to mention the 2nd part that's better is if you have a change order for whatever reason whether it's the location of a lighting changing or a desk's location, these types of MC connectors are also easier to remove when needed. Just better for the long term.

  • @hippo-potamus
    @hippo-potamus 2 роки тому

    How does the "industrial cover" secure in the "1900 box" when the box you showed only had 2 screw mounts on opposite corners yet the cover had 4 screw holes on each corner???

  • @balexan530
    @balexan530 4 роки тому

    This electrical box is usually called a 1900 Box because that was the original part number from Bossert almost a hundred years ago. It is the most common box used when a simple SwitchBox is not large enough.

  • @garbo8962
    @garbo8962 Рік тому

    For commercial work always purchased panels & junction boxes without KO'S so I could make KO'S to line up with handy unistrut saving an offset . Also used steel EMT fittings instead of POS garbage die cast fittings.Have to be careful with handy gangable wall cases. Boxes from different manufacturers often will not gang together. Love the 12 by 12" JB with built in MC connectors & ground bar. If you are going to connect a critical motor or motor that will turn on & off more then say 30 times a hour best to go with a made in USA NEMA full size real deal starter ( Square D & Allen Bradley ) starter rather then inferior IEC contactors which most will not allow you to replace contacts.Flex = greenfield.

  • @ralphramsey82
    @ralphramsey82 4 роки тому +2

    I appreciate these videos that take you back to the basics. 👍🏻

  • @jwoutdoors1451
    @jwoutdoors1451 3 роки тому +2

    Currently in the HVAC trade but thinking about switching to electrical and working to get my masters and own my own business one day

  • @taylorhill7756
    @taylorhill7756 Місяць тому

    Thanks Dustin, I'm getting ready! 💪

  • @Madsleepy
    @Madsleepy 2 роки тому

    As and electrical estimator that was never in the field, I really appreciate your videos especially this one.

  • @Qvinner
    @Qvinner 3 роки тому +1

    In Canada the first two are called 4x4’s and 4x4 duplex covers lol but I’m guessing the name 1900 comes from Iberville’s product number

  • @RodgerFeahr
    @RodgerFeahr Рік тому

    On a commercial jobsite you will have a set of documents including, drawings, specifications, and submittals. In these cases it is important to understand deviation in materials may not be acceptable.

  • @kyleblume6530
    @kyleblume6530 4 роки тому +1

    I am a carpenter. And we were doing a demo job, which included gutting a kitchen. And our electricians had to move lights, add outlets, add switches, and segregate lights. But the drywall was already up. And couldn’t rip it apart. How do electricians feed wire thru a wall without being able to get in from the attic or remove the drywall???

    • @thetxrebelslas6897
      @thetxrebelslas6897 4 роки тому

      kyle blume I worked new residential electrical for a while and we cut “transfers” in the Sheetrock at studs to drill through the stud and fish, then run the wire through.. after installation or running, we would screw the piece we cut out back onto the stud and the sheet rockers would patch the cracks..

    • @kyleblume6530
      @kyleblume6530 4 роки тому

      The guys that did our drywall didn’t cut any drywall aside from the new sockets being installed. And the new round holes for light cans in the ceiling.

    • @thetxrebelslas6897
      @thetxrebelslas6897 4 роки тому +1

      kyle blume gotcha, the ceiling was probably the easier of the two.. they do make extremely long drill bits that allow us to hook a wire on the end of and drill through Walls, Joyce’s, and fire blocks.. it’s a lot of hard work though, not cutting or removing Sheetrock when moving runs or plugs and switches.. depending on how far the relocation is of course.. if it was only a couple inches to a foot of moving around it’s doable from the “Demo hole” from removing the fixture or outlet.

    • @thetxrebelslas6897
      @thetxrebelslas6897 4 роки тому

      Of course Dustin could give you the proper technical terms and ideology behind how we go about doing things like that!😂

    • @kyleblume6530
      @kyleblume6530 4 роки тому +1

      I was figuring a video would be slick

  • @Penguin545
    @Penguin545 Рік тому

    I remember watching this video shortly before I started my first job in electrical (didn’t know what any of them did) and then a couple months in (had a good idea what most of them did), and now 18 months in I can say that I am familiar with everyone of these materials. 🤓

  • @Josephhoward28
    @Josephhoward28 Рік тому

    I had been looking for a career path for several years now. I kept thinking that because my birth dad and his brother and his father and my mom's father were all electricians that maybe I got the spark in me!😂 A few people kept talking me out of it and said that's a bad reason to go into it.. well finally one day I said "enough's enough! I'm tired of being financially unstable and not good husband material because I can't provide! I'm going to apply and go back to school." The next day I called out of work at my roofing company and drove down 3 hours to Phoenix to a training school. The school put me in touch with a very large Commercial contractor in Phoenix and I was hired later that week. I start in two weeks and I know literally nothing about this field. I'm glad I found this channel, I'm probably going to devour all of your videos over the next week before my job starts. THANK YOU!!!

    • @Biglittlemack
      @Biglittlemack Рік тому

      How’s it going man… how long did it take to catch your balance as an electrician? I just started 4 days ago and still feel like i know nothing

    • @Josephhoward28
      @Josephhoward28 Рік тому

      @@Biglittlemack I got fibromyalgia and insomnia and started missing work and then got fired. Staying at my friends small trailer in a small town I used to live in and learning framing. My electrician company was toxic. Had to file harassment complaints w EEOC against my manager and most the guys on my crew were pretty cold. My foreman however said I was one of the best apprentices they've had in a long time. I guess my longterm plan is be humble, minimize expenses and God willing someday start my own LLC doing something I already got experience in

  • @unkeptimpaler
    @unkeptimpaler 4 роки тому +1

    Hey Dustin I hope you pick up the video grind again soon I’d love to see some of your day like even if you wore a go pro and recorded your day or your most annoying things you come across. I’m an apprentice 6 month’s in and I enjoy your content and wanna see more day by day struggles like how you would solve getting a wire around a corner when roughing or stripped screws stuff that happens but not often and cause a big struggle for you. It’ll give me some experience or tips on my own day to day. Much love keep up the good work my dude

  • @kylehurley9103
    @kylehurley9103 4 роки тому +1

    Maybe it’s just AZ but I have NEVER heard of a 1900 box. We call them 4S boxes here lol.

  • @samv2783
    @samv2783 4 роки тому +4

    In my area flexible metal conduit is called greenfield. I assume that was originally a brand name.

    • @davidgagnon2849
      @davidgagnon2849 3 роки тому +1

      That's what I learned it as, too. And the weatherproof or Raintite, as Dutin referred to it as was called Sealtite.

  • @Benny_From_NY
    @Benny_From_NY 2 роки тому

    In nyc we use all those commercial grade material in residential high rises

  • @Baz1122
    @Baz1122 2 роки тому

    I start my apprenticeship this Monday I’m excited I’m doing commercial

  • @jps12872
    @jps12872 4 роки тому +1

    You gonna do PVC and fittings, also liquid tight and fittings. We do a lot of underground with PVC schedule 40 & 80

  • @inecronomicsi4285
    @inecronomicsi4285 Рік тому +1

    My favorite part of doing switches is when you discover at the final that one of your lovely coworkers has tied in the wrong switch legs at the rough-in stage.
    Not just tied into the power pigtail... No..
    Tied-in to the wrong 2gang switch box entirely 😅 (side by side in the wall but in different rooms 👍)
    Not *that* hard to fix... But.... Yeah 😅🥳

  • @400080vikkash
    @400080vikkash 4 роки тому +1

    Usually called a 4 square box or 4 11/16 box but then depending where you are people call it differently

  • @charlesjcobb
    @charlesjcobb 3 роки тому

    Here in the East we all call MC cable, BX cable. When it was being developed, there several versions being tested. A experimental, B experimental, C......., their names were shortend to AX, BX, CX..... The Bx won out and the name stuck. So, around here that's what we all call it. We call armor jacket (bx with no wire) , Greenfield. But that's another story

  • @Steve_mos8541
    @Steve_mos8541 3 роки тому +1

    so 1900 is what we call 4 square and the 2100 is the 4 11 or four eleven right?

  • @mperron3
    @mperron3 Рік тому

    Would someone please post a link to that sweet 12 by 12 junction box.... That can accept MC cables so easily.

  • @Rinkyu
    @Rinkyu Рік тому

    Conduit fittings, connectors have threadings and couplings dont

  • @Darisiabgal7573
    @Darisiabgal7573 3 роки тому +3

    The gangable boxes are a pain, but they are a hell of a lot more durable than the blue plastic boxes that flip around in the wall. That romex is “acceptable” in houses, barely. I don’t think the rodents in our area have learned that 120VAC is a bad thing to eat, fair number of plastic chews.

  • @theroadking547
    @theroadking547 8 місяців тому

    Where did you get the junction box from?

  • @vsprice1
    @vsprice1 4 роки тому +1

    Thank you, I have been wanting you to make a series of videos like this love the channel

  • @ivovim2504
    @ivovim2504 3 роки тому

    Just came across your video - Amazing. Very informative. I am getting into the commercial electrical as well and this helps a lot. Stay safe.

  • @jamesconklin120
    @jamesconklin120 3 роки тому

    Been in the commercial field for the past 25 plus years , recently been working in Hospitals and medical buildings , the company I’m with now uses most of the material you mentioned , except the snap in connectors , we use the locknutables 🤪 , better to use when you fish mc cable down a wall and install a cut in box , Also the mc cable in hospitals has to be Hospital Grade ( FYI , industrial covers is also called raised covers )

    • @LucasGresham610
      @LucasGresham610 3 роки тому +1

      As a service electrician I prefer the locknut MC connectors as well.

    • @jamesconklin120
      @jamesconklin120 3 роки тому

      @@LucasGresham610 well we know how bulky those locknutable connectors are especially if you fishing down a wall into a 4”sq box that already has a snap in double barrel connector in it 🤦‍♂️ A lot twisting involved, not a fun fishing trip

    • @mistanipples4958
      @mistanipples4958 2 роки тому

      Thinking about dropping hvac school and going to commercial electrician, mind if I ask how much u make? I’m trying to get a feel for what pays most

    • @jamesconklin120
      @jamesconklin120 2 роки тому

      @@mistanipples4958 It Depends on where you live , and what kind of commercial work , you could get on with a company doing government contracts and make bookoo bucks or get in a union

  • @jameshaas5680
    @jameshaas5680 4 роки тому

    This first company to make the 4x4 box at early turn of century. Its part no. For the box was 1900. It has carried through the century

  • @bryanduchane2371
    @bryanduchane2371 2 роки тому

    Been out of distribution since 2015 and this was a to down memory lane.

  • @ronrowhani8428
    @ronrowhani8428 3 роки тому

    1900 box is called four square in California.

  • @stevewilson3522
    @stevewilson3522 4 роки тому +5

    Lovin' the Letterkenny big shoots!

  • @Bad-Karma
    @Bad-Karma 2 роки тому

    I have been trying to find that Arlington/Hubbel 12x12 or 14x14 for quite a while now. Neither company seems to list it on their site. Does anyone have a part number on that thing?

  • @Berzerk29
    @Berzerk29 4 роки тому

    I looked it up. They're called 1900 boxes because that was the original part number from the manufacturer Bossert.

  • @richardsherman152
    @richardsherman152 3 роки тому

    Who is going to be making that can with the MC connectors?

  • @Bapuji42
    @Bapuji42 Рік тому

    What's your opinion on the use of red devils with MC connectors?

  • @edew9180
    @edew9180 4 роки тому +1

    Good basic info, but we have some different lingo here haha! Good vids, keep em comin!

  • @vandoo66
    @vandoo66 3 роки тому

    Yup! There’s way more but this was a great overview. Commercial rules!!

  • @sirnordeng430
    @sirnordeng430 3 роки тому

    You hide your joints in that 1900 box??? You hand roll or pre rolled?

  • @richt5986
    @richt5986 Рік тому

    1900 box was the part number for steal city in the early 1900s. Ita actually NOT CALLED A 1900 box anywhere but the east coast. That is a slang term. The correct term is 4 square deep or shallow.

  • @steve-tm6nh
    @steve-tm6nh 4 роки тому +2

    Great video. How about one on all the different emt clamps.

  • @omarsandoval5025
    @omarsandoval5025 Рік тому

    Random question, I am located in Lincoln, Nebraska and MC cable is literally not allowed. Inspectors don’t accept it, and won’t ever ever pass it! How do inspectors justify prohibiting it here, if code obviously allows it, hence why MOST states use it. And if it’s illegal in all jobs, idk why all parts stores still sell it.

  • @goudagames8408
    @goudagames8408 4 роки тому

    Are commercial public buildings and apartment complexes in the US required to use halogen free cable against toxic gas released when heated like in Europe ?

  • @Alex-jo2oi
    @Alex-jo2oi 4 роки тому

    Started working in the shop so I have to know every single part. I’m putting together foreman’s lists for different jobs and dropping them off. It’s pretty cool. I’ll be getting in eventually as well.

    • @adrians.1154
      @adrians.1154 3 роки тому

      stockman?

    • @Alex-jo2oi
      @Alex-jo2oi 3 роки тому

      @@adrians.1154 material handler. same shit.

    • @adrians.1154
      @adrians.1154 3 роки тому

      @@Alex-jo2oi nice, im about to start as one, any tips?

    • @Alex-jo2oi
      @Alex-jo2oi 3 роки тому

      @@adrians.1154 stay on point write everything down and keep a list of the break times. Don’t ask the same question more than once. Don’t show up on their lunch or break. If you have stops to go to don’t mess around until at least after you drop everything off. Ask questions about the jobs and be interested. Learn as much of the material as you can. Show them you’re serious about the job and don’t be arrogant. Put your ego to the side. Embrace the dumb things you might do and learn from it.

    • @Alex-jo2oi
      @Alex-jo2oi 3 роки тому

      @@adrians.1154 almost forgot an important one. Take initiative and don’t wait for them to tell you what to do.

  • @gl0wbot768
    @gl0wbot768 2 роки тому

    Hey thanks! I'll be checking out the channel!

  • @nickroeder7512
    @nickroeder7512 2 роки тому

    When I read the title of the video I was like oh let's see what he goes over. Then realized here in Chicago everything that must be commercial everywhere else is just considered the basics here that's even used in residential.

    • @XLGaming
      @XLGaming 2 роки тому

      I live near chicago, and my house is also commercial for some reason!

  • @mikeholland8968
    @mikeholland8968 4 роки тому

    Good video! Anyone know If M/C CABLE can be used in cellulose insulation? Not sure if it can harm the casing. Having trouble finding info on this!

  • @gorillawarfare7523
    @gorillawarfare7523 2 роки тому

    Relay and contactor are different terms. A contactor is in a relay which also has a solenoid.

  • @barrettready1713
    @barrettready1713 2 роки тому

    Love this now to find the residential one

  • @pleappleappleap
    @pleappleappleap 2 роки тому

    What exactly is the difference between tubing and conduit?