Anderson A2 Electric charge point Installation London

Поділитися
Вставка
  • Опубліковано 8 вер 2024

КОМЕНТАРІ • 25

  • @artisanelectrics
    @artisanelectrics 2 роки тому +3

    Great job 👍

  • @Lukieboy2010
    @Lukieboy2010 2 роки тому +2

    Great video. Keep them coming!

  • @nusermane1076
    @nusermane1076 2 роки тому +2

    You’re doing really good videos!
    I also watch Artisan Electrics and they started on UA-cam just like you did, nowadays they need extra personal for YT.
    As soon as it pays off to publish on YT you can hire a guy for YT (or at first just pass someone the videos for production as a service).
    From what Artisans say, YT really pays off as a promotion and trust building channel for the company, so I think you will benefit a lot!
    Keep good videos coming, I like it!!!

    • @maydayelectricalsolutionsl7601
      @maydayelectricalsolutionsl7601  2 роки тому +2

      Thanks Nuser that’s quite a compliment to be mentioned in the same sentence as Jordan from Artisan

    • @nusermane1076
      @nusermane1076 2 роки тому +1

      @@maydayelectricalsolutionsl7601 You’re welcome, can’t wait for more 🙂

  • @delspark
    @delspark 2 роки тому +2

    Really liking the channel 👍 I didn’t think BG did a double pole RCBO , I find Andersen chargers a pain in the back side 20 odd screws 🤬🤬

    • @maydayelectricalsolutionsl7601
      @maydayelectricalsolutionsl7601  2 роки тому +2

      No it wasn’t well spotted Learning curve for myself, thank you for the channel support

    • @delspark
      @delspark 2 роки тому +1

      @@maydayelectricalsolutionsl7601 least you can change the RCD to type A an move across, cheaper than a mistake I made doing a Tesla £120 for a type b 😤🤯

    • @maydayelectricalsolutionsl7601
      @maydayelectricalsolutionsl7601  2 роки тому +1

      @@delspark yes we usually install the Garo units on the Teslas. Extra faffing around so I try and talk clients out of the Tesla chargers

  • @hineshpatel8903
    @hineshpatel8903 2 роки тому +2

    Great video. Very informative 👏

  • @spencermichaels6524
    @spencermichaels6524 2 роки тому +1

    Smashed it mate 🔥👏

  • @electricalservicesmaroc
    @electricalservicesmaroc 2 роки тому +1

    Great ✅✌👍✅

  • @darrellobrien4416
    @darrellobrien4416 2 роки тому +1

    why didn't you run a draw rope through the cavity through a length of conduit and pull in the cable into the back of the charger an into the main board ? (Removing the conduit after getting draw rope through)

    • @maydayelectricalsolutionsl7601
      @maydayelectricalsolutionsl7601  2 роки тому +1

      I don’t think I have your skills Darrell but given the cavity I think your idea is quite a good one

    • @londontrada
      @londontrada 2 роки тому +1

      Interesting idea, I wouldn't bank on being able to pull that off though. There can be all sorts of stuff blocking cavities.

  • @Mainly_Electrical
    @Mainly_Electrical 2 роки тому +1

    Has the Anderson got PEN fault

    • @maydayelectricalsolutionsl7601
      @maydayelectricalsolutionsl7601  2 роки тому +1

      As standard the Anderson had a double pole PEN detection unit with 30ma ac and 6ma DC earth leakage detection, Anderson have just halted production for an unknown reason so can’t use them at the moment

    • @Mainly_Electrical
      @Mainly_Electrical 2 роки тому +1

      @@maydayelectricalsolutionsl7601 thanks for replying, you know your onions , keep the videos coming

  • @doma5262
    @doma5262 2 роки тому

    any surge protection?