thanks for the nice video, please one question regarding the holding regisers, you used the hexa address 8501 and you have chosen the related bits among of 16 bits, my question that i am really confuesd of how to convert any bits from bit 0 to bit 15 into decimal number, is there a methode that helps me to understand better, because it is not clear to me, for example you chose bit 12 and you converted into decimal , can you please explain it . thx
Will this setup work for altivar 930 vfd with Modbus TCP and s7-1200 Ethernet switch? Will a normal Ethernet cable work between altivar modbus and s7-1200 Ethernet switch?
@@AutomationBD Correction 2 wire cable cable. Plc side 9 pin connector in 3 and 8 number pin connection. Drive side rj 45 connector in 4 and 5 number pin connection.
It was great and complet.
Thanks for stay with us.
excelente video !!
Gracias por este conocimiento, sufrí mucho para parametrizar el modbus en TIA portal, pero ahora ya tengo un nuevo poder !
Thanks for stay with us.
TOP PROFESSOR! FUNCIONOU PERFEITAMENTE .
Thanks for stay with us.
Amazing!!!! thank you very much and blessings
Thanks for stay with us.
thanks for the nice video, please one question regarding the holding regisers, you used the hexa address 8501 and you have chosen the related bits among of 16 bits, my question that i am really confuesd of how to convert any bits from bit 0 to bit 15 into decimal number, is there a methode that helps me to understand better, because it is not clear to me, for example you chose bit 12 and you converted into decimal , can you please explain it . thx
You can used PC calculator. There selection programmer. There you easily change bit to decimal number.
Thanks for stay with us.
Make a video sir on how to configure profibus communication with Tia portal to abb dc drive
Wait for me I will make a tutorial about this
Do you have the connection diagram between the source, the PLC, the VFD and the motor?
Will this setup work for altivar 930 vfd with Modbus TCP and s7-1200 Ethernet switch?
Will a normal Ethernet cable work between altivar modbus and s7-1200 Ethernet switch?
❤❤
Is this modbus TCP or RTU?
TCP
@@AutomationBD esa comunicacion es RTU, el TCP es con client y server
What is the type of modbus cable you use??
2 wire cable cable.
Plc side 9 pin connector in 3 and 8 number pin connection.
Drive side rj 45 connector in 4 and 5 number pin connection.
@@AutomationBD Correction
2 wire cable cable.
Plc side 9 pin connector in 3 and 8 number pin connection.
Drive side rj 45 connector in 4 and 5 number pin connection.
😊😊😊😊😊😊