VRF/VRV HVAC Systems | Working principle and benefits | HVAC 11

Поділитися
Вставка
  • Опубліковано 25 гру 2024

КОМЕНТАРІ • 98

  • @scruffy01100000
    @scruffy01100000 2 роки тому +7

    I'm an FM that just started at a new company, Mitsubishi VRF setup cooling all my IDF's, separate cooling tower setup for comfort cooling along with chillers serving FCs and data center IRC's, and a few CRAH units here and there in some labs.
    This is the first time I've dealt with VRF;s and this video was a nice primer as I just finished a day of walking roofs with our mechanical vendor and didn't have enough time to deep dive. That's the fun part of managing MEP, there is always something new to learn about and geek out when we go back up tomorrow and finish out the campus mechanical tour hehehe.

    • @jollyscaria1922
      @jollyscaria1922 7 місяців тому

      VRf systom Hvac verables refrgnt systom one unit morinfoor verbls 7 uing ficmcing log modesl vompann modelx fixinv indoof mord lifixex sompoit hvac ac systom

  • @GretschenMunch
    @GretschenMunch 2 роки тому +20

    I put a 5 head heat pump VRV unit in my house to replace 25 year old ducted reverse cycle. Could not be happier! So efficient and less expensive to run.

    • @AMJEngineering
      @AMJEngineering  2 роки тому +2

      Could you please advise the capacity of VRV unit compared to replaced one, and how much energy are you saving oer month?

    • @dingdong3124
      @dingdong3124 2 роки тому

      iijioj

    • @dingdong3124
      @dingdong3124 2 роки тому

      iyeah jyeah uuihi

    • @張鴻盛
      @張鴻盛 Рік тому

      ​@@dingdong3124😮🎉😅😢😢

  • @PigBenis4U
    @PigBenis4U 2 роки тому +14

    I work with this these machines everyday. They can give you headaches, but are still fun to work on. Nice video.

    • @AMJEngineering
      @AMJEngineering  2 роки тому +1

      Appreciate your feedback. What type of problem you are facing with them?

    • @PigBenis4U
      @PigBenis4U 2 роки тому +2

      @@AMJEngineering mainly leaks and faulty PCB or Inverter boards

    • @jamesrothwell1738
      @jamesrothwell1738 2 роки тому +1

      Rather have refrigerant piping than water. Water leaks cause damage, refrigerant leaks just cost money in the price of the technician coming out toleak test and recharge

    • @PigBenis4U
      @PigBenis4U 2 роки тому +1

      @@jamesrothwell1738 have you ever delt with a fully loaded VRV system with 200lbs of R410a? These things are a nightmare for leak checking. Refrigerant doesn't get replenished automatically like with water where you have a makeup water system.

    • @codythompson9035
      @codythompson9035 2 роки тому +1

      Absolutely hating VRF. Nothing but issues. Only tech in my office that works on the Mitsubishi that our mechanical keeps installing. Just recently had fun replacing a reversing valve on a twinned outdoor system after 1 year at a firestation. Kept getting a refrigerant overcharge alarm when defrost would occur, alarm would happen instantly before maintenance tool would refresh data. Had to use rare earth magnets on the valve to indicate position and to find which one was the issue.

  • @myaqureshi8901
    @myaqureshi8901 9 місяців тому +2

    I have 3 separate vrf systems in my house and 1 of them is water cooled. Very good.

  • @moin17basha80
    @moin17basha80 2 роки тому +6

    Very good explaining & Easy to understand

  • @gyasuddin4412
    @gyasuddin4412 2 роки тому +2

    Thanks for sharing such a easy to understand

  • @sergiomarinmaldonado3993
    @sergiomarinmaldonado3993 2 роки тому +1

    Thank you! Great material!

  • @timothyrichardson8567
    @timothyrichardson8567 4 місяці тому +1

    So How does this help with a Midwest City like Chicago where it gets 20 below zero ?

  • @ithzzmeadh5625
    @ithzzmeadh5625 3 роки тому +5

    Nice video bro.. Tell us more about HVAC systems

  • @karthikkannan6753
    @karthikkannan6753 2 роки тому

    Thanks for the valuable input... :)

  • @saitharkyaw4384
    @saitharkyaw4384 Рік тому +1

    When outdoor got errors, how will be each indoor? Are they working separately or not?

    • @AMJEngineering
      @AMJEngineering  Рік тому

      All indoors connected to the same outdoor will be out of service till you repair the outdoor. Outdoor unit is the main unit containing the compressor.

  • @muhammadkamran851
    @muhammadkamran851 2 роки тому +1

    Thank you dear sir!

  • @markegg262
    @markegg262 2 роки тому +3

    Funny, I’m fighting with Toshiba about my domestic VRF with 4 heads. It’s showing a full load COP of 3 but part load of 1.75 at std conditions. They say it’s working to spec but book says 4.4/5.

    • @michaelchris270
      @michaelchris270 2 роки тому

      Should of went w a Daikin they’re a reason they trademarked VRV

  • @jasonallen2498
    @jasonallen2498 2 роки тому +5

    Big warning though...sometimes the refrigeration piping sizing, which is tricky, gets installed wrong and you start killing compressors. When this happens you get stuck with the problem because the mnfr says it is not their fault and the installer will refuse to take responsibility for it...so you go thru pain and $ until you get frustrated and rip it all out and start over.

    • @AMJEngineering
      @AMJEngineering  2 роки тому +7

      Yes you are right, thats why every manufacturer has its own sizing design software for pipe arrangement and sizing. I have experience in this as I used to work few months in Mitsubichi electric company.

    • @jollyscaria1922
      @jollyscaria1922 2 роки тому

      Vrey good jolly

    • @Jlopez2207
      @Jlopez2207 Рік тому

      True

    • @paulmcclung9383
      @paulmcclung9383 Рік тому +2

      Get your layout, run lengths, and elevations; then vet the design with the manufacturer.

  • @wonyoon1931
    @wonyoon1931 2 роки тому +8

    All new homes should be equipped with the VRF systems. I think the lack of proper training is the reason for the HVAC contractors in the USA not installing them.

    • @AMJEngineering
      @AMJEngineering  2 роки тому +6

      Also their higher cost is another main reason.

    • @michaelchris270
      @michaelchris270 2 роки тому +3

      @@AMJEngineering agreed 8-20k install compared to a 30-70k install

    • @muhamadromdoni5501
      @muhamadromdoni5501 6 місяців тому +1

      Us are 4 types of season and extreme weather. With the current economy, do you think average American family can afford it?

  • @shenoyglobal
    @shenoyglobal 2 роки тому +5

    Is Hybrid VRF system best for 7000 Sq ft residential G +2 storey home in Florida?- considering Mitsubishi

    • @WTTvlogs
      @WTTvlogs 2 роки тому +3

      Yes it will be beneficial for your residential building in your electricity savings and increase your system efficiency ..I recommended to you diakin vrf ..diakin is a top most in vrf system
      We installed mostly diakin unit in UAE and Middle east .

    • @shenoyglobal
      @shenoyglobal 2 роки тому +2

      @@WTTvlogs I understand there is one hybrid vrf with higher seer from Mitsubishi?

    • @AMJEngineering
      @AMJEngineering  2 роки тому +1

      Yes vrf system is your best choice. Actually mitsubichi and daikin are on top list. Just look for the best price.

    • @michaelchris270
      @michaelchris270 2 роки тому

      No ! Go VRV

  • @MansourGhadhban
    @MansourGhadhban Рік тому +1

    Very good

  • @workhardforit
    @workhardforit 2 роки тому +3

    We’re using full DC inverter Hitachi and Mitsubishi Heavy Industries air conditioners in our home-all 5 units almost running 24/7.
    Our bill is just around $100 a month, we live in the tropics and we have one of the highest rates in terms of utility costs in Asia but I’m pretty happy with my bill now.
    We used to pay upwards of around $200-300 a month for just two conventional units a couple of years ago.
    Yeah the units are expensive as hell but that is a small price to pay for machines that are reliable, insanely quiet, and provide us extreme comfort for extended periods of time.

    • @ryanleeds1973
      @ryanleeds1973 2 роки тому

      wait until they start to break down😅😆

    • @AMJEngineering
      @AMJEngineering  2 роки тому +1

      Thanks for this great information

    • @michaelchris270
      @michaelchris270 2 роки тому

      That’s bc it’s a variable compressor it works on capacity load. 👌 it’s working how it’s designed for your climate most VRV/VRF systems have a blueprint of the house and system install etc

  • @babaolowo35
    @babaolowo35 Рік тому +1

    THANK you

  • @timothyrichardson8567
    @timothyrichardson8567 4 місяці тому

    Is There a Certified Class I can take on this System along with HVAC-R?

  • @Jlopez2207
    @Jlopez2207 Рік тому +2

    Initial expense is high the turn around on money back takes a long time. But if you use the compressors year around they dont last especially with 410

  • @marwan75
    @marwan75 Рік тому

    Is it good for an apartment of 3 bedroom? (In terms of power)

  • @wallacekung
    @wallacekung 2 роки тому +2

    hi sir, why the energy efficiency of VRF @1.07 kw/ton is so low?

    • @AMJEngineering
      @AMJEngineering  2 роки тому +2

      because VRF is a smart system technology, its purpose is to reduce energy consumption of conventional split systems. conventional split systems efficiency range between 1.6 to 2.2 kw/ton. VRF acts similar to what VFDs do in chillers and pumps, gives only the required flow @ the required compressor partial load therefore, saving a lot of energy. the number 1.07 kw/ton was based on one study only made in UAE. More data should be gathered from different projects at different locations around the world to came up with accurate number and compare it with water cooled chiller or air cooled chiller plants.

  • @nilakanthamishra9190
    @nilakanthamishra9190 9 місяців тому

    Very interested.

  • @rickysambilay6520
    @rickysambilay6520 2 роки тому +1

    im a beginner for VRF,,, can you upload for wiring in indoor at out combination

    • @MelodyMan69
      @MelodyMan69 6 місяців тому

      Imagine a "Daisy Chain" from 1st Indoor to each of the other Indoor than to the Outdoor. It is a 2 wire 1.2mm shielded cable.

  • @envitech02
    @envitech02 2 роки тому +2

    Great video!!

  • @qasammukri6122
    @qasammukri6122 Рік тому +1

    Thanks

  • @mathewmathunny7514
    @mathewmathunny7514 8 місяців тому

    Nice one

  • @myaqureshi8901
    @myaqureshi8901 9 місяців тому

    Very cool.

  • @kbombers45
    @kbombers45 2 роки тому +3

    What if the whole building needs to be cooled and all the units need cooling, they suck and are a scam. Like 30k for one unit. I have seen them manufactured, very difficult to work on and manufacture.

    • @AMJEngineering
      @AMJEngineering  2 роки тому +1

      If all building needs cooling at the same time then better to go for chillers option. VRF are a great option in residential buildings, with every dwelling unit having its own outdoor unit.

    • @peteygr
      @peteygr 2 роки тому +1

      You are a pessimist. Keep buying old technology and paying a fortune for the utilities.

  • @abyisac5547
    @abyisac5547 2 роки тому +1

    👏👏👏

  • @rajiulraji856
    @rajiulraji856 3 місяці тому

    Suupp ❤

  • @_tamilinithu_
    @_tamilinithu_ 2 роки тому

    👍❤️

  • @mustaquekhan945
    @mustaquekhan945 Рік тому

  • @StuartGalvin-v3e
    @StuartGalvin-v3e 3 місяці тому

    49054 Halvorson Cove

  • @eugeneb3682
    @eugeneb3682 Рік тому +2

    Romans 8:31
    if God is for us who can be against us?

    • @KWTxrulz
      @KWTxrulz Рік тому

      Quran 1:5
      You ˹alone˺ we worship and You ˹alone˺ we ask for help.

  • @igorfreitas2841
    @igorfreitas2841 3 роки тому +3

    👍🇵🇹

  • @AntoinetteFanny-l8s
    @AntoinetteFanny-l8s 3 місяці тому

    Young Maria Jackson Barbara Gonzalez Scott

  • @Jc124
    @Jc124 Рік тому

    Only downside is how expensive the boards are in the condenser 😂

    • @Jlopez2207
      @Jlopez2207 Рік тому

      They are probably coming from china they have a monopoly

  • @JonalynSchismenospk
    @JonalynSchismenospk 3 місяці тому

    Martinez Sandra Perez Dorothy Walker Nancy

  • @ACTSElectricalDept
    @ACTSElectricalDept Рік тому +1

    hello

  • @angelesrivero4213
    @angelesrivero4213 Рік тому +1

    "Hi gents!" Ok, bye

  • @AntoinetteFanny-l8s
    @AntoinetteFanny-l8s 2 місяці тому

    Young Brenda Wilson Ruth Anderson Frank

  • @dirkstephenson20
    @dirkstephenson20 3 роки тому +12

    Lazy use of robot reading.

    • @AMJEngineering
      @AMJEngineering  3 роки тому +19

      It is more time consuming than using own voice. English is not my native language so a clear voice maybe preferred by most people.

    • @kirillfedtsov
      @kirillfedtsov 3 роки тому +3

      Dicken haha! Nice video, though

    • @MelodyMan69
      @MelodyMan69 6 місяців тому

      Yeh. The alternative might have been a Japanese Guy.

  • @IHF625
    @IHF625 2 роки тому

    There is no rocket science involved here , look at carrier air-conditioning models and units with simple work method and efficient carrier air-conditioning is best rest others companies come up with some stories in mechanism for there product sales and marketing.

    • @AMJEngineering
      @AMJEngineering  2 роки тому +2

      😒 it seems you're carrier sales person

    • @0x-X-x0
      @0x-X-x0 2 роки тому

      @@AMJEngineering lol seems like it xD

  • @jameskaranja1982
    @jameskaranja1982 2 роки тому

    Noneses upregate our tenolog

  • @MacadamMarcus-y1x
    @MacadamMarcus-y1x 3 місяці тому

    Lee Ruth Taylor Dorothy Miller Betty

  • @Jlopez2207
    @Jlopez2207 Рік тому

    A piping nightmare

  • @cryzz0n
    @cryzz0n 2 роки тому +1

    Very good explaining & Easy to understand

  • @markarvinalfaro
    @markarvinalfaro 5 місяців тому

    Thankyou