Sir grade 1 sand q le rahe hain usme fm bahot zyada retain rehta hai aggregate kam karna hoga 9 cube mould q 6 cube generally use hota hai 3 cube for 7 days n rest 3 cubes for 28 days 3 cubes 3days k liye kya use karenge acceleration curing k liye N cube mould 150 mm each hona chahiye Firm cube weight above 7.5 kg must hai n minimum breaking force 225 kn v hona hai sir g
@@ShaniKiVaani sir ye cement ka hai 150 mm concrete cube ka hai fir Opc ka v video dijiye sir g Cone test k bare me Sdt, extripping, los angeles, flakiness, sieve analysis of grade 1 aggregate n of grade 2 aggregate , sand sieve analysis test,cube vibration test, softening point, penetration, ductility, kinematics viscosity, emulsion test, lime test, docket weight test etc se related v video dijiye sir g as per is code
Very interesting.. civil se nhii huin toh bhi mann kr rha h dekhun... Nice Shani bhai
Thank you bhai
Congratulations 🎉
One of the best ❤️
Thank you sagar ❤️🙏
Very nice thanks for sharing
Good information 🙏
Informative 🤞
Nyc video 👌
Very nice sir ji
Nice video
Wonderful 🎉
Thank you 🙏
Helpful video thank you 👍
Thank you
Good bro
Waiting for next ✅
👍👍
Good
Nice
Thanks
👍👍good
Super sir
Great work
Thank you
Concept clear ho gya
Helpful video
Nice bro
Nice sir
Nice video for cement testing
Good job 👍👍
Supar
Very nice
Very nice 👍👍
Thank you 👍
❤❤❤❤❤❤
Very informative 🔥
Vibration Rpm 12000+-400
2min
Room temperature 27 degree +-2 h ji @shani ki vani
ji
opc 53 grade and ppc ultratech is any difference in strength and if yes than how much
Petrolium gelly oil kya hota hai sir kaha se milta hai kya cube me lagane ke liye dusra oil bhi use kiya ja sakta h
ji bhai koi bhi chalega jo ap ko saste me mil jaye
Sir insteed of paper ,pls explain on black board or white board .so v can see properly.
ok
Bhai next video to bna do iske aage ki . aadhi information leke kaha jayenge hum
ok ager kuch puchana hain to contact me on whatsapp 9559239246
Good.. But vibration is 12000+-400 not 14000.
Dimensions of rod(length×dai)=600mm×16mm
yes bro 👍
Happy Birthday bhai. Part yaad se dena
jarur
14000 nhi hota 12000 hota hai bhai +- 400
Hi bro. App tho cement industry vala nahi hai bai.
12000+-400 RPM hota hai vibration machine ka speed
Yes broo❤
Which zone's sand will be use for this process.
only use standard sand 2mm passing 1mm retained 1mm passing 500mic retained 500mic passing 90mic retained .
Hey sir within how many days the curing can be done
3day & 7 days & 28 days
Is it c39 or no
affter casting qube put in the humidity Chamber.. ?
Video to bhot acchi hai pr apki awaj hi nhi aayi apne kya kya kha
ok
Isko khola ne me konsa number ka pana lagta he
After water adding only two minutes mixing
Sir grade 1 sand q le rahe hain usme fm bahot zyada retain rehta hai aggregate kam karna hoga
9 cube mould q 6 cube generally use hota hai
3 cube for 7 days n rest 3 cubes for 28 days
3 cubes 3days k liye kya use karenge acceleration curing k liye
N cube mould 150 mm each hona chahiye
Firm cube weight above 7.5 kg must hai n minimum breaking force 225 kn v hona hai sir g
nahi bhai cube size 70.6 × 70.6 × 70.6 hota hain and for ppc grade ke liye 16 n/mm² and 22 for 7 days 33 for 28 days .ok 👍
contact me 9559239246 .
@@ShaniKiVaani sir ye cement ka hai
150 mm concrete cube ka hai fir
Opc ka v video dijiye sir g
Cone test k bare me
Sdt, extripping, los angeles, flakiness, sieve analysis of grade 1 aggregate n of grade 2 aggregate , sand sieve analysis test,cube vibration test, softening point, penetration, ductility, kinematics viscosity, emulsion test, lime test, docket weight test etc se related v video dijiye sir g as per is code
ok
স্যার এগুলা সেখার জন্য কোনো বই আছে
Take water from Buratte
Bhai aap ka udhar quality Kam milega kiya
nhi bro
Good but vibration 12000+-400 only 2 minute vibration
Sir compaction ke liye use ki gae rod standard nahi hai
ji right 👍
Woh mould ke neeche kya hei..
Khuli he kya bottom woh mould ka
Your Propotion ratio is not Correct ??
Density of Cement and Sand is Not Same. You shoud take Volume CEMENT , SAND , AGGREGATE
Mai to freez me rakhunga.
kyu
@@ShaniKiVaani strong banne ke liye
ppc ya opc or strength kitne
Vikat mould hight
Mixing proper nahi kiya konsi lab
kiya h
3+4 kahase ayi sir
According mortar cube formula. P+3/4*8
Bhai 12000+- 400 ata Hain
Hello Bhai Kaise Ho MAi rahat Obra se Video editor Rahat pahchane bhy apna Number dijiye phon reset kiya hu number delet ho gya😜
6306089943
Tamping rod is not standard
Why is standard sand used?
Please reply fast I have my viva
ok wait
@@ShaniKiVaani okay
The main reason for using standard sand is to eliminate its effect on the reported strength of the mortar cubes.
@@ShaniKiVaani thank you
Worst procedure followed... No way it is as per IS 4031 testing..
Tempting rod sahi nahi h
ok
Tamping rod not standard
yes
Sir apka number dedo please 🙏
6306089943
Good
Nice sir
Nice
Very good
Good
Nice sir
Nice
Good
Nice sir
Nice
Good