A Minimum quantity of water required to initiate the chemical reaction between water and cement to form a paste is known as consistency of cement. Standard Consistency - It is that cement consistency which will allow the Vicat plunger to penetrate to 5-7 mm point from the bottom of Vicat mould is known as standard consistency. There is no time limit .It is just like liquid limit test.
Sir....isss test me penetration value 5 to 7 milne ke liye time required kitna hein?kitna time me niddle 5 se 7 tak rukna sahie....ya time ka koi matlab nahi hein?mera matlab hein niddle penetrat hone ka time....
मै हे आपका सिमेंट Cansitansi गलत है मेरा नाम Gautam v kadam.है मै ACC LTD मै 41 Year's sarvic cement technisyan था अब मैं रिटायर्ड हू आप जोभी करते हो सब गलत है.मेरा Contec no.9769097064
Actually he's saying R8 about humidity but we can't able to change the atmospheric conditions for the precise betterment of this test. That should be required when we need high level of precision thanks.
You can start the test from 26 % water content , go on increasing until you get required reading for standard consistency. Please see whole video for clarification.
It is just a assumption to fillup sufficient paste in mould... If you have to required more cement then take it,,,,, it does not matter what is the weight required but it give impotant about to fillup the mould a minimum weight should be taken & i.e 400gm
Big salute to u n ur team.
So nice of you
Thnq sir........ye video dekh kr bahot kuchh sikhane ko mila aur sir thoda upakarn ke bare me batana chahiye tha
Please see video with interest you will find your answer.
Sir, I think while testing room, water Temperature should be 27⁰C ± 2⁰C hona chahiye,
and Humidity 65% ±5%
please iseke bare me thoda bataye...
Sir,,, prime coat and tack coat par video bnay full ditels me 🙏🙏🙏💖
Already posted
Sir, please explain the limit of consistency ?
Sir, could I take 500gm of cement and add 23% of water by weight of cement in first trial?
SCT perform karne ke liye Kitna time period tak plunger ko penitrate karne Dena hai
See the video with interest you will find your answer .
@@HIGHWAYGUIDE i seen this video without skipping but I not got my answer please tell us.
I got only one time period which is for making paste and filling in mould with in 3-5 min but I never got pentrating time for SCT
A Minimum quantity of water required to initiate the chemical reaction between water and cement to form a paste is known as consistency of cement.
Standard Consistency - It is that cement consistency which will allow the Vicat plunger to penetrate to 5-7 mm point from the bottom of Vicat mould is known as standard consistency.
There is no time limit .It is just like liquid limit test.
How consistency affect on mix design??
Sir....isss test me penetration value 5 to 7 milne ke liye time required kitna hein?kitna time me niddle 5 se 7 tak rukna sahie....ya time ka koi matlab nahi hein?mera matlab hein niddle penetrat hone ka time....
Please see full video with interest.
Nice
thanks sir,
very detailed explain sir
Hope to watch my full video on any subject to have clear idea about pertaining subject.
good job wt of next video
Sir What is the Difference Between Normal Consistency and Standard Consistency
Both are same.
Normal consultancy and standard consultancy are same?
There are both same
Bro normal consistency =gadapan
Or consultancy =salah hota hai
I mean before learn write thereafter ask answer
Sir plizz explain Air permeability method in hindi.. Plizzz
OK wait for 15 days
Bhaut sukuriya 🙏
It was very helpful. Thank you.
Tq sir
Nice video...Thanks for this.
Keep on watching
but humidity should be 90%.
Do you know what does mean by 90 % humidity ?
मै हे आपका सिमेंट Cansitansi गलत है मेरा नाम Gautam v kadam.है मै ACC LTD मै 41 Year's sarvic cement technisyan था अब मैं रिटायर्ड हू आप जोभी करते हो सब गलत है.मेरा Contec no.9769097064
Actually he's saying R8 about humidity but we can't able to change the atmospheric conditions for the precise betterment of this test.
That should be required when we need high level of precision thanks.
@@gautamkadam4067 sir hamare cement ka water percentage kitna hone se cement quality acha hai hum janenge kese
Sir 400gm chahi ye na
nice video sir...very helpful video
Ty Bhai
Great explanation 👌👌👌 thankss sir
Thanks
So nice of you
thanx sir
Good video sir
Thanks
Explanation% Quantity of water from to from
You can start the test from 26 % water content , go on increasing until you get required reading for standard consistency. Please see whole video for clarification.
Sir, could I take 500gm of cement and add 23% of water by weight of cement in first trial?
300gms he q lete hai ans please
Because 300 gram is sufficient for filing the mould , you can take 400 or 500 gram no problem
Why 300 gms not 400 gm
Because 300 gram is sufficient , if you want you can take 400 gram.
It is just a assumption to fillup sufficient paste in mould...
If you have to required more cement then take it,,,,, it does not matter what is the weight required but it give impotant about to fillup the mould a minimum weight should be taken & i.e 400gm
Thanks Sir
Sir plizz explain Air permeability method in hindi.. Plizzz
OK
Thanks sir