Watter retand line fixing actuacter fixed suppley cold water coil in passing cold up come distbuting super air dis buting custmbers ductbls fcu ahu all chilar systomed
Hi..your videos are full of knowledge and the topics covered in your videos are highly in demand. If possible, will you please make all your videos in English so that more and more people get the benefit of your videos with no language barrier ?
Sir Here if we controlled the AHU Return through 3 way valve that's ok. Whatever to be controlled some of water to flow AHU always because we can't block the AHU inlet. So here AHU water can't able to full blocked. Can able to block the amount of water less than 3 way valve 3rd way.
But actuator Chilled water in la podama chilled water out la potu vachi iruku,apd panarathala ahu ku flow suthama irukatha? Return agum valve valiya but ahu kum pogum thana?
My self seetharam am working in Dubai. I was worked two more areas but one Our site Actuators connected in supply line (inlet) why ❓I don't know could u explain me
Bro some room la vac close Ana main duct pressure athigama agum ..main duct end la antha sensor fix Pani irupainga ..aipa pressure increase agumpothu staic pressure sensor sense Pani fan speed slow panum
bro in 2 way system the bypass line connected to supply and after actuator. because we need to control ahu temperature otherwise as explained by you water is flowing through ahu coil we cannot maintain coil temperature and no need the actuatuor
Hi bro. AHU la vfd control blower motor iruku. Set point 24c reach ayita chilled water flow stop ayidum. Then temperature automatic ah increase aagum. Apo vfd yoda function enna bro? Motor speed kammi pannuna enna agum? Temperature increase aaguma illa decrease aaguma? Plz clear me
Bro..if control valve is installed in return line.how we can stabilise the certain chilled water(l/s) for particular air handler? Why it does not install in supply line??Its my biggest doubt
Ahu in inside on coil off coil .. have when temp reach that valve is close that why installed return line ..water regulating in coil ..again when temp need that time valve is open
Anna sari anna oru doubt supply linelayum motorized value iruku but nega soldra mari return layum iruku ana return la value automoticka close aita water epadi supply vazhiya return ku bypass la pogum ean na supply bypass value iallaga so how possible konjam detail la solluga illana unaga number sollugaa
Adhuku dan VFD concept pumps use pannuvanga once return line closed back pressure create agum then differential pressure sensor sence panni pump speed ah korachudum adhukaparam chiller kita oru bypass irukum illana hot well cold well concept irukum
Hi sir. நான் வேலை செய்யும் இடத்தில் இரண்டு கூலிங் டவர் உள்ளது water top up செய்ய ஒரு pump உள்ளது ஒன்றில் ஆட்டோ பில்லிங் இன்னொன்று manual filling இப்போது இங்கு aucvator use panni float fix panni ரெண்டும் ஆட்டோ use panna முடியுமா ஆனா ரெண்டு side same. Comand வந்தா என்ன ஆகும்
Sir in simple pls tell me how these 2way and 3way valves are put in chw piping Reason why only 2way, benefits of 2 way valve Reason why only 3 way,benefits of 3 way valve
Bro gas chaging procedure konjam explain pannunga.ella gas oda boiling pt epdi find out panrathu.ipo gas chaging time la discharge side gas charge pannaa Enna pblm varum konjam explain panunga bro plzzzz
சகோதரரே ! இப்போது ஒரு சிறிய சந்தேகம் 1 ahu க்கு 10 ரூம் இருக்கிறது அதில் 4 ரூம்ல கூலிங் அதிகமாக இருக்கிறது கூலிங்க குறைக்க சொல்லி கம்ப்ளைண்ட் வருகிறது .. ஆனால் மீதி 6 ரூமுக்கு கூலிங்க் தேவை குறிப்பு : bms problem and actuator valve not work ( open position ல இருக்கு ஆனால் not wotk ) vcd not (vav not ) available , two way valve இப்போது 4 ரூமுக்கு கூலிங்க் இல்லாமலும் , 6 ரூமுக்கு கூலிங்க் கொடுக்கனும் Supply line ல flow வை கண்ட்ரோல் பன்னனுமா இல்லை return line actuator வால்வுக்கு முன்னால் இருக்கும் normal gate valve close செய்துவிட்டு by pass valve control பன்னனுமா விளக்கம் தேவை ... Hot well and cold well பற்றி கொஞ்சம் தெளிவான விளக்கம் தேவை
Konjam simple aana visyam Dan 4 rooms AHU lay chilled water return line valve( before control valve) manual valve close pannunga wat ever percent you want This situation is only for non working of control valves indha madiri senja tevayana temp control panna mudiyadhu
@@lohisya_media 1 ahu 10 roomukku supply கொடுக்குது 2 மற்றும் 4 மற்றும் 7 மற்றும் 9 ரூமுக்கு கூலிங்க குறைக்கனும் மற்ற அனைத்து ரூமுக்கும் கூலிங்க் தேவை சில்லர் ( leaving temp 12 deg celcius ... entre 14 deg celcius) இப்போது எனக்கு 4 ரூமுக்கு கூலிங்க். கண்ட்ரோல் பன்னனும் Vcd கண்டுபிடிக்க முடியவில்லை .... , vav இல்லை , 2 way வால்வு தான் இருக்கு , actuator valve open position ல fault ஆகி இருக்கு , Fresh air damper low close (10 percentage open ) இப்போது எப்படி கண்ட்ரோல் செய்வது Supply dampera கொஞ்சம் குறைக்கனுமா , fresh air line கண்ட்ரோல் பன்னனுமா , Actuator valve க்கு முன்னாடி இருக்கும் நார்மல் வால்வை close செய்து பை பாஸ் வால்வை கொஞ்சம் குறைத்து வைக்கனுமா Chill water supply valve கொஞ்சம் குறைக்கலாமா
@@lohisya_media தாங்கள் சொன்னது போன்று செய்தாலும் கண்ட்ரோல் பன்ன முடியவில்லை சகோதரரே எனக்கு 4 ரூமுக்கு temperature அதிகமாக்கனும் மற்ற ரூமுக்கு அதே temperature maintaine பன்னனும் Supply line valve குறைக்கலாமா ? குறைக்க கூடாதா ?
@@abdullam.m5331 nanba automatic control valve with temperature sensor illamal room temperature maintain panna mudiyadhu neenga supply valve close panna room temperature goes to ambient temperature
Hai Ravishanker, Could you please make a video of FAHU full controls both for DX and for CW units thats compatible with VFD and BMS, Appreciate your effort to make these videos as referral to hvac field techies. Also do some videos on precision control units of Liebert ,Airedale and Emerson with its settings. Great appreciations...
Sir, ungaloda explanation ellame very useful in my life.
Sir super your teching very usbuls sir sari yor cont namper
En work oda asthivaaramae neenga than Anna!.unga notes ah vachi than konjum konjum nagathuran.No words only Thanks 🌺 Anna!
Where you working brother??
Bro .. semmaya explain pandringa.. romba usefully iruku.. inum neria videos podunga.. waiting for your updates..
Bro thanks
Today three way valve doubt vanthichi cleared panitinga bro 👍
Brother you were really helpful
Hi Ravi, Good for Leaners with your easy explanations.
Hi Ravi,
Unga vedio ellam super..innum different concept la electrical la neenga vedio pannanum... vedios are really helped....thank you so much...
Very useful message brother
Thanks sir good explain this, very use full😊
Very useful for beginners
Your all videos is well bro.
Thanks bro
Romba useful anna
Super bro ... thanks for giving useful educational video's...we expect more &more from you...
Explained super...
Good information
Hi Ravi,
Doing fantastic Great Job, keep rocking with new concepts.
Thanks
Super explanation
Thanks sir good explanation
Good explanation bro.Pls Continuously upload new videos about Hvac.
Thanks bro
Bro BMS and DDC panel pathi video pannunga bro pls....How control reaches from BMS to DDC pathi pannunga bro
In my site DDC panel erected but bms has been cancelled. But still dint control sensor not fixed
Watter retand line fixing actuacter fixed suppley cold water coil in passing cold up come distbuting super air dis buting custmbers ductbls fcu ahu all chilar systomed
Tq so much bro. Good explanation
Good explanation
Thanks
Good information broo but ...ahu , intha mathiri irukka work ku full form konjo sollunga .... request broo 🎉
@@msViswanathan-dt3dw ok
Thank you
Please add good video like this.. We need your Support for Mep Sections
Ok bro
Very good sir
Superb explanation.. upload more..
Very good boss
Good information thk u sir...
Thanks bro
Very nice explain sir
Very useful brother..hydrotest la body and seat pressure range evalavu sollanga bro..
💓 thanks sir 💓
make one video on vsd pump how do they work were it fix
Nandri Nanba
Thank you nanba
Hi..your videos are full of knowledge and the topics covered in your videos are highly in demand. If possible, will you please make all your videos in English so that more and more people get the benefit of your videos with no language barrier ?
Chiller side actuator return la irukuma supply la irukkumaa bro
Acutator wiring and machanism eapdi check pandrathu solluga bro
Thanks brother
If water flow is fine and grill temperature also good but there is no more air flow could suggest me the better opinion to reach air flow
Thaks bro
I also belongs from chennai
Sir chiler control wire and pump to chiller control wirering explain pannu sir
Sir ok but AHU to work station how to 23°+or- maintain the temperature please share video
Great!
Sir actuator 2 position iruku.direct & reverse.plz discuss
Please explain three way valve flow sir
Bro appidiyae ella units la vara problem pathi video upload pannunga
Wiring connection video podunga sir
I am living Kuwait working HVAC technician
Positioner explain working bro
Anna bms system eppide worku akuthu aprm etha ddc panel wire diagram epide worku akuthunu our video poduka anna
Good news
Hi bro, why actuator put in to return line?
Anna electro pneumatic positioner details sluga anna
Sir Here if we controlled the AHU Return through 3 way valve that's ok. Whatever to be controlled some of water to flow AHU always because we can't block the AHU inlet. So here AHU water can't able to full blocked. Can able to block the amount of water less than 3 way valve 3rd way.
But actuator Chilled water in la podama chilled water out la potu vachi iruku,apd panarathala ahu ku flow suthama irukatha? Return agum valve valiya but ahu kum pogum thana?
My self seetharam am working in Dubai. I was worked two more areas but one Our site Actuators connected in supply line (inlet) why ❓I don't know could u explain me
super anna
good one bro.
Balance valve function pathi podugka brom
Reason for not install the actuator in supply line? Pls reply
If we connect direct to actuator it possible to maintain cool
AHU yeppadi BMS la control pantrathu . BMS la AHU controlling concept yenna. return temperature setpoint value reach ammavidam ey AHU off aiduma
Bro, turn on super thanks option.
Bro duct la static pressure and VAV epdi work avuthunu sollunga bro
Bro some room la vac close Ana main duct pressure athigama agum ..main duct end la antha sensor fix Pani irupainga ..aipa pressure increase agumpothu staic pressure sensor sense Pani fan speed slow panum
Hi sir... please explain how to work picv.. please please please
Sir mere pas 1 actuator motor he 18 karne se very sulow andar jata he
Kia problem hosakta he
Anne chiller fcu unitil roomil temperature decrease aakale.actualtor valve Matti pathen.sheriyavale
Chilled water temperature evlo iruku bro and chilled water flow iruka inlet and outlet pressure difference evlo iruku
Super bro, enaku actuator wiring connection explain pannuga, motham moonum iruku, 24V AC input, 0-10V DC cmd and 0-10V DC feedback , ethuku kudukuraga
0-10v DC eapdi kudukuraga
Supply and activator ku ulla Enna components lam irukunu explain pannuga
Annan fcu motor spoil la eppadi kadupudikirathu
Anna basic plumbing principle video podunga na
Hello sir you told about BMS DDC penal
Anna bypass valve yappa work aakum
A.Ganesan
K.velangudi
Hello vanakkam anna Google video video Nalla Neram Re Mari Padi lehenga Marion useful Hamari World Wide Angle the Volvo Haryana gana super
bro in 2 way system the bypass line connected to supply and after actuator. because we need to control ahu temperature otherwise as explained by you water is flowing through ahu coil we cannot maintain coil temperature and no need the actuatuor
Super
Hi bro. AHU la vfd control blower motor iruku. Set point 24c reach ayita chilled water flow stop ayidum. Then temperature automatic ah increase aagum. Apo vfd yoda function enna bro? Motor speed kammi pannuna enna agum? Temperature increase aaguma illa decrease aaguma? Plz clear me
good...
Bro..if control valve is installed in return line.how we can stabilise the certain chilled water(l/s) for particular air handler? Why it does not install in supply line??Its my biggest doubt
Ahu in inside on coil off coil .. have when temp reach that valve is close that why installed return line ..water regulating in coil ..again when temp need that time valve is open
Pls upload more vedio nanba
Anna sari anna oru doubt supply linelayum motorized value iruku but nega soldra mari return layum iruku ana return la value automoticka close aita water epadi supply vazhiya return ku bypass la pogum ean na supply bypass value iallaga so how possible konjam detail la solluga illana unaga number sollugaa
Adhuku dan VFD concept pumps use pannuvanga once return line closed back pressure create agum then differential pressure sensor sence panni pump speed ah korachudum adhukaparam chiller kita oru bypass irukum illana hot well cold well concept irukum
Hi sir. நான் வேலை செய்யும் இடத்தில் இரண்டு கூலிங் டவர் உள்ளது water top up செய்ய ஒரு pump உள்ளது ஒன்றில் ஆட்டோ பில்லிங் இன்னொன்று manual filling இப்போது இங்கு aucvator use panni float fix panni ரெண்டும் ஆட்டோ use panna முடியுமா
ஆனா ரெண்டு side same. Comand வந்தா என்ன ஆகும்
VFD and BMS enna slluinga sir naa new join sir
Sir in simple pls tell me how these 2way and 3way valves are put in chw piping
Reason why only 2way, benefits of 2 way valve
Reason why only 3 way,benefits of 3 way valve
How actuator work in FCU s..? Plz
Bro gas chaging procedure konjam explain pannunga.ella gas oda boiling pt epdi find out panrathu.ipo gas chaging time la discharge side gas charge pannaa Enna pblm varum konjam explain panunga bro plzzzz
Anna posisner working principle sollunga....
Gud...
Thanks
3 way Valve or PICV valve - Pressure independent control valve actuator oda connect aagirukum
Sir hydraulic valves working explain
Hi sir actuater auto mood not working how to manual open
Which voltage in achivetor valve
Hi sir please explain two position direct couple actuator
Can u teach us about accumulator charging control valve?
Super sir
சகோதரரே ! இப்போது ஒரு சிறிய சந்தேகம்
1 ahu க்கு 10 ரூம் இருக்கிறது அதில்
4 ரூம்ல கூலிங் அதிகமாக இருக்கிறது
கூலிங்க குறைக்க சொல்லி கம்ப்ளைண்ட் வருகிறது .. ஆனால் மீதி 6 ரூமுக்கு கூலிங்க் தேவை
குறிப்பு :
bms problem and actuator valve not work ( open position ல இருக்கு ஆனால் not wotk ) vcd not (vav not ) available , two way valve
இப்போது 4 ரூமுக்கு கூலிங்க் இல்லாமலும் , 6 ரூமுக்கு கூலிங்க் கொடுக்கனும்
Supply line ல flow வை கண்ட்ரோல் பன்னனுமா இல்லை return line actuator வால்வுக்கு முன்னால் இருக்கும் normal gate valve close செய்துவிட்டு by pass valve control பன்னனுமா
விளக்கம் தேவை ...
Hot well and cold well பற்றி கொஞ்சம் தெளிவான விளக்கம் தேவை
Konjam simple aana visyam Dan
4 rooms AHU lay chilled water return line valve( before control valve) manual valve close pannunga wat ever percent you want
This situation is only for non working of control valves indha madiri senja tevayana temp control panna mudiyadhu
@@lohisya_media
1 ahu 10 roomukku supply கொடுக்குது
2 மற்றும் 4 மற்றும் 7 மற்றும் 9 ரூமுக்கு கூலிங்க குறைக்கனும் மற்ற அனைத்து ரூமுக்கும் கூலிங்க் தேவை
சில்லர் ( leaving temp 12 deg celcius ... entre 14 deg celcius)
இப்போது எனக்கு 4 ரூமுக்கு கூலிங்க். கண்ட்ரோல் பன்னனும்
Vcd கண்டுபிடிக்க முடியவில்லை
.... , vav இல்லை , 2 way வால்வு தான் இருக்கு , actuator valve open position ல fault ஆகி இருக்கு ,
Fresh air damper low close (10 percentage open )
இப்போது எப்படி கண்ட்ரோல் செய்வது
Supply dampera கொஞ்சம் குறைக்கனுமா , fresh air line கண்ட்ரோல் பன்னனுமா ,
Actuator valve க்கு முன்னாடி இருக்கும் நார்மல் வால்வை close செய்து பை பாஸ் வால்வை கொஞ்சம் குறைத்து வைக்கனுமா
Chill water supply valve கொஞ்சம் குறைக்கலாமா
@@abdullam.m5331
Which room you want to less the temperature that AHU return line valve partially close and open the bypass line 75 % it will
@@lohisya_media
தாங்கள் சொன்னது போன்று செய்தாலும் கண்ட்ரோல் பன்ன முடியவில்லை
சகோதரரே எனக்கு 4 ரூமுக்கு temperature அதிகமாக்கனும் மற்ற ரூமுக்கு அதே temperature maintaine பன்னனும்
Supply line valve குறைக்கலாமா ? குறைக்க கூடாதா ?
@@abdullam.m5331 nanba automatic control valve with temperature sensor illamal room temperature maintain panna mudiyadhu neenga supply valve close panna room temperature goes to ambient temperature
air compressor topic panunga bro
Particularly air compressor pathi enna topic bro illana full ah venum ah
Hai Ravishanker,
Could you please make a video of FAHU full controls both for DX and for CW units thats compatible with VFD and BMS,
Appreciate your effort to make these videos as referral to hvac field techies.
Also do some videos on precision control units of Liebert ,Airedale and Emerson with its settings.
Great appreciations...
Please explain wiring connection diagram
Sir please explain in English or Telugu , Nice video your sharing but I can't understand tamil or otherwise put or add english subtitles
Ok bro definitely I do in telugu