Це відео не доступне.
Перепрошуємо.

Dangerous Electric Work Earthing Connection With the Busbar।Electric Work with Expert Electric Men

Поділитися
Вставка
  • Опубліковано 11 лют 2020
  • how earthing works animation,
    how does earthing work,
    what is earthing,
    importance of earthing,
    tncs earthing system,
    types of earthing ppt,
    what is earthing and types of earthing,
    pipe earthing,
    what is earthing in electricity,
    what is earthing and types of earthing,
    importance of earthing,
    earthing definition,
    types of earthing pdf,
    types of earthing ppt,
    earthing systems diagrams,
    advantages of earthing,
    earthing systems diagrams,
    earthing system pdf,
    importance of earthing,
    earthing definition,
    what is earthing and types of earthing,
    types of earthing ppt,
    earthing system design,
    advantages of earthing,
    #Earthing_System_Installation
    #Earthing_Desing
    #Electric_Earthing_System

КОМЕНТАРІ • 53

  • @samuelkatherinediozarago7692
    @samuelkatherinediozarago7692 3 роки тому +8

    For people who ask or want to know why this is ULTRA dangerous,here is your answer:
    Besides from Connections etc
    1-They do use only a single rod. For redundancy and safety as well as MOST importantly to Lower the resistance,you need 3 or 4 rods connected with each other.Also Dry soil =Higher resistance Wet=Less resistance..
    2-Not tested with earth resistance meter means it is a Good as a stake in ground which may not work at all!...You place 3 rods,connect resistance meter to them and test to see if it reads the guideline ohm/resistance. Else,this is just silly rod in the ground when someone is zapped and turned charcoal black..

  • @elec3xn8tw0rx9
    @elec3xn8tw0rx9 3 роки тому +5

    My mind and intuition whispers that this type of work requires a technically equipped professional who does the job. Reading, watching and educating yourself about earthing regulations in an hour will tell you so.

  • @KezzWelbrn
    @KezzWelbrn 4 місяці тому +1

    its perfect to us the electricians.........

  • @ololmia226
    @ololmia226 3 роки тому +1

    ধন্যবাদ

  • @bobybehroozi5878
    @bobybehroozi5878 4 місяці тому +1

    You should put this covered cable inside the anti-humid tube ( Foroplast tube.

  • @Blooppenheimer
    @Blooppenheimer Рік тому +2

    4:12 mistake !: don't cut and use longer copper wire to increase the touching surface between wire anr the copper rod.

    • @learnpassearnprofessional7467
      @learnpassearnprofessional7467  Рік тому

      Thank you for your comments. Please share our videos to your friends and family and country. Like us, support us and dont forget to subscribe our channel.

    • @Blooppenheimer
      @Blooppenheimer Рік тому

      @@learnpassearnprofessional7467 i call every people in Turkiye right now to watch this video buddy. Hold tight

  • @ajaysharma9939
    @ajaysharma9939 3 роки тому +2

    Hi, can I make the pipe earthing near my plastic water tank ?
    Will it be safe?
    Please reply

  • @Radhapzr
    @Radhapzr 3 роки тому +7

    These guys do not know the basic theory of earthing in Electrical work.

  • @mohammedwashimakram4513
    @mohammedwashimakram4513 Рік тому +1

    Electric room to earth menhole how many meter fixed?

  • @negrodjxijangelo6450
    @negrodjxijangelo6450 3 роки тому +3

    how is this wrong, drive the rod in the ground connect the wire to main panel. seems simple

  • @stevenlawhon3695
    @stevenlawhon3695 3 роки тому +4

    Rods are wrong diameter 5/8 or 3/4 needed. cable too small 6awg-2awg

  • @Presso99
    @Presso99 10 місяців тому +5

    Misleading video, one rod is definitely not meeting the standards, minimum 2. When i started watching this video, i would expect them to measure the earth resistance using the earth resistance meter, if it meets 10 ohms and below, it is acceptable, of course the best is 5 ohms and below, the lower the better. If it doesn't meet, what is the next course of actions? This video doesn't show all these steps and recommendations such as how to improve the resistance by using GEM, copper mat and etc. One more thing, the ground wire clamping looks so flimsy, if someone dig the soil and accidentally pull the wire, the ground wire is slip through the grip. It is waste of time watching this.

  • @yahyakambi1191
    @yahyakambi1191 4 роки тому +5

    May I please know why these earthing is wrong and dangerous.

    • @BarryBollox.
      @BarryBollox. 3 роки тому

      This

    • @samuelkatherinediozarago7692
      @samuelkatherinediozarago7692 3 роки тому +1

      @@BarryBollox. For people who ask or want to know why this is ULTRA dangerous,here is your answer:
      Besides from Connections etc
      1-They do use only a single rod. For redundancy and safety as well as MOST importantly to Lower the resistance,you need 3 or 4 rods connected with each other.Also Dry soil =Higher resistance Wet=Less resistance..
      2-Not tested with earth resistance meter means it is a Good as a stake in ground which may not work at all!...You place 3 rods,connect resistance meter to them and test to see if it reads the guideline ohm/resistance. Else,this is just silly rod in the ground when someone is zapped and turned charcoal black...

    • @new-techengineering1684
      @new-techengineering1684 2 роки тому

      @@samuelkatherinediozarago7692 thank you

  • @jimmykadaviparambil9622
    @jimmykadaviparambil9622 3 роки тому +4

    Very bad connection , chance to loose anytime between rode and wire

  • @gulzarkhan8860
    @gulzarkhan8860 3 роки тому +6

    This guy is not a Electrician.

  • @kathiroliconnect3849
    @kathiroliconnect3849 Рік тому +1

    Copper rod earth

    • @learnpassearnprofessional7467
      @learnpassearnprofessional7467  Рік тому

      Thank you for your comments. Please share our videos to your friends and country. Like us, support us and subscribe to my channel.

  • @t.gh.4023
    @t.gh.4023 4 роки тому +2

    how much deep in the earth muss the electrode conductor?
    thanks mate

    • @learnpassearnprofessional7467
      @learnpassearnprofessional7467  4 роки тому

      Thanks dear for your comments. Please share our video to your friends and country. Like us comment us and subscribe us

  • @nuraddeenibrahim4039
    @nuraddeenibrahim4039 2 роки тому

    Please add english subtitle

    • @learnpassearnprofessional7467
      @learnpassearnprofessional7467  2 роки тому

      Thank you for your comments. Please share our videos to your friends and family. Like us, comments on our videos and subscribe our channel.

  • @cederbergfitness9797
    @cederbergfitness9797 3 роки тому +1

    the green tape makes all that crap work much better ,how about using an electrician with experience

  • @SanmartinElectricidad-Obras
    @SanmartinElectricidad-Obras 3 роки тому +1

    you need more tools...

    • @learnpassearnprofessional7467
      @learnpassearnprofessional7467  3 роки тому

      Thank you so much for your comments. Please share our videos to your friends and country. Like us, comment us and subscribe to our channel.

  • @influxelectricalsolution7600
    @influxelectricalsolution7600 3 роки тому +2

    🤭🙄🙄🙄cap and jacket are in proper way but not earthing

  • @dishantgauswami4808
    @dishantgauswami4808 4 роки тому +2

    Ye konse engineer he electric to nai lag rahe

  • @benjiedingding7226
    @benjiedingding7226 Рік тому

    Shuhada,, maskara,, siokol,,, Mafi mukh.

    • @learnpassearnprofessional7467
      @learnpassearnprofessional7467  Рік тому

      Thank you for your comments. Please share our videos to your friends and family and country. Like us, support us and dont forget to subscribe our channel.

  • @jakhannew
    @jakhannew 4 роки тому +9

    This is terrible ! Extremely poor work with no understanding of electrical engineering standards.

  • @piotrpiersa5459
    @piotrpiersa5459 8 місяців тому +1

    it is not good job.

    • @learnpassearnprofessional7467
      @learnpassearnprofessional7467  8 місяців тому

      Thank you

    • @piotrpiersa5459
      @piotrpiersa5459 8 місяців тому

      @@learnpassearnprofessional7467 Look at my video, connect the earth electrode underground with a flat bar, not a cable.ua-cam.com/video/2tqXiqoiQz8/v-deo.htmlsi=Nw_muE2qu6W8lOVB

  • @dipueducation1490
    @dipueducation1490 3 роки тому +2

    This is not a right method.

  • @tahirriaz7780
    @tahirriaz7780 2 роки тому +1

    Totally wrong

    • @learnpassearnprofessional7467
      @learnpassearnprofessional7467  2 роки тому

      Thank you for your comments. Please share our videos to your friends and family. Like us, comments on our videos and subscribe our channel.

  • @mathewmm2193
    @mathewmm2193 4 роки тому +8

    Unprofessional

    • @BarryBollox.
      @BarryBollox. 3 роки тому

      Please explain

    • @chriscs9080
      @chriscs9080 3 роки тому

      This is very professional . You just missed the point where he says it's a barbeque .