Why 30 mA RCCB circuit breaker is used in home, Hindi

Поділитися
Вставка
  • Опубліковано 6 вер 2024
  • You learn in this video, why RCCB circuit breaker of 30 mA type is used for houses/home, in Hindi. Uses of 30mA and 300mA RCCB and residual current requirement of RCCB circuit breaker for electric shock protection, and for fire protection is explained. The safe limit of the current flow in the human body and time relation is explained. Protection against electric shock, Frequent tripping of RCCB is discussed. Educational video tutorial on electricity & electrical engineering in Hindi, 329 by G K Agrawal (Gopal Krishna Agrawal).
    The lecture is given by a person with industrial experience.
    Watch Electricity unit calculation for the house in Hindi
    • KW to electric unit kw...
    • 3 Phase Voltage; Why r...
    • Why 30mA RCCB circuit ...
    • Star delta connection ...
    LinkedIn / g-k-agrawal-09a5743b
    Twitter / gkagrawal1955
    WordPress letusshareknow...
    Blog g-k-agrawal-el...
    Facebook / gopalkrishna.agrawal.12
    #GKAgrawal #ElectEnggByDesigner #ConceptByProductDesigner #GopalKrishnaAgrawal #ElectricShock #RCCB #30mARCCB #ResidualCurrent #300mARCCB #Electrical

КОМЕНТАРІ • 273

  • @GKAgrawal2
    @GKAgrawal2  4 роки тому +4

    Membership
    ua-cam.com/channels/O31rZS4_EDYJ8CGXiRZdxg.htmljoin

  • @Vinodvinod-tq3qg
    @Vinodvinod-tq3qg 2 роки тому +1

    महोदय जी आप इतने अच्छे से जानकारी दिये बहुत बहुत धन्यवाद, हमारे आश्रम मे एसी 1.5 टन, और 1hp मोटर ,दो फ्रीज हैं कौनसी Rccb लगाये कृपया जानकारी देने का कष्ट करे

  • @RahulKumar-rs9pz
    @RahulKumar-rs9pz 2 роки тому +1

    Thank you so much sir mujhe iss knowledge ki shakht jarurat thi

  • @yuvrajpatil9668
    @yuvrajpatil9668 3 роки тому +1

    Nice video sir ....
    हम इसी व्हिडीओ के प्रतिक्षा में थे ।
    धन्यवाद सर.....

  • @ELECTRICALSGUIDE
    @ELECTRICALSGUIDE 3 роки тому +4

    Amazing knowledge sir I have 10+ year Experience in electrical industries but you are my best teacher for electrical engineering

  • @panditvishal5451
    @panditvishal5451 5 років тому +5

    sir amazing explanation of this concept never anyone explained this type now please make a video of transformer stability video REF and SEF protection practically

  • @SahaBapan
    @SahaBapan 5 років тому +2

    Sir you have given us a wonderful information about RCCB by a beautiful class teaching. I got so many important facts about RCCB from your video.
    Thank you.

  • @allinonebysk9793
    @allinonebysk9793 5 років тому +4

    Sir, your teaching style is always great 👍

  • @rajeshkhakharia933
    @rajeshkhakharia933 2 роки тому +1

    Sir, You expained so nicely!!!👌👌👌💐💐💐Many thanks for solving my query.

  • @avia3297
    @avia3297 5 років тому +9

    Very exclusive information in this video on the RCCB selection

  • @irshadansari7538
    @irshadansari7538 2 роки тому +1

    Given great Gyan

  • @kumarpankaj3437
    @kumarpankaj3437 3 роки тому

    Nice video aap bahut acha samjhate h

  • @jayshankarbhumkar51
    @jayshankarbhumkar51 4 роки тому +1

    Hii sir me apke sare video dekhta hu bahut achha padhate ho sir app. thank You 🙏imp Theory padhne ke liye

    • @GKAgrawal2
      @GKAgrawal2  4 роки тому

      Very good, apki knowledge avashya badegi.

  • @amitabhakdh
    @amitabhakdh Рік тому

    Lot's of thank you sir
    Pranam 🙏

  • @PRAMODKUMAR-ii3qf
    @PRAMODKUMAR-ii3qf 3 роки тому +1

    Thanks sir for good knowledge.

  • @badalasingh9355
    @badalasingh9355 4 роки тому +1

    Bahut achha se batahe hai sir

  • @maroofwarsi3754
    @maroofwarsi3754 2 роки тому +1

    Very Super

  • @anshumantripathi3873
    @anshumantripathi3873 2 роки тому +1

    Thank you Sir

  • @maheshkokate760
    @maheshkokate760 3 роки тому +1

    Very good

  • @fernandespeter9232
    @fernandespeter9232 2 роки тому

    Sirji pranam,
    Your videos are truly inspiring.
    Is there a difference between RCCB and ELCB???
    Or is their working principle the same???
    Thanks sirji.

  • @babershaikh5399
    @babershaikh5399 3 роки тому +1

    Very informative video. Your way of explaining is superb. I slute you.

  • @gandlavenkatesh2147
    @gandlavenkatesh2147 4 роки тому +1

    Very nicely explain thank you sir i have faced one problem in one soft were office Falceling led light fixture fired shot circuit and flame came but no mcb was trips luckily we was their swith off the main supply fire controled immediately plz telme that what type of MCB we can use in this location...

    • @GKAgrawal2
      @GKAgrawal2  4 роки тому

      Watch my video on AFDD breaker for arc sensing and fire protection
      You can provide small rating normal MCB for every room.

  • @kanhaisha2601
    @kanhaisha2601 3 роки тому +1

    Sir great learn with you.sir please make a vedio on electrical standards.

  • @SS-jq9uy
    @SS-jq9uy 2 роки тому

    Very informative. Thank you for sharing this valuable knowledge. I don’t know why RCCB in my single floor house is 63A 100mA. Should I change this to 30A

    • @GKAgrawal2
      @GKAgrawal2  2 роки тому

      30mA is better. But your RCCB is 63A, do you have such heavy loads.

    • @SS-jq9uy
      @SS-jq9uy 2 роки тому

      @@GKAgrawal2 No Sir, one that I know is 1HP submersible pump in boring and usual refrigerator, RO, TV, Fans in households. For some reason if 30A may trip would it be ok to go with 40A /100mA.

  • @RajeshYadav-be7ds
    @RajeshYadav-be7ds 5 років тому +2

    I was looking for such a great video thanks sir

    • @GKAgrawal2
      @GKAgrawal2  5 років тому

      Feel happy that, you got necessary information in my video.

  • @raajeshvernekar4268
    @raajeshvernekar4268 4 роки тому +1

    Sir, Thank you for one of the best explanation in selecting RCCB.
    But I have question which one to choose 40A or 63A

    • @GKAgrawal2
      @GKAgrawal2  4 роки тому

      Depend upon load current.

    • @sunilkumar-he3ey
      @sunilkumar-he3ey 4 роки тому +1

      @@GKAgrawal2 sir mein 3kw use hota hay toh kitnay amp ka rccb lgana chahiye btaye pls

  • @shivamgupta-bj4ub
    @shivamgupta-bj4ub 8 місяців тому

    Sir, In your video Titled AC or DC which is more dangerous, you told us that for 50/60 Hz AC supply a typical value of 12 mA causes a female person to lose her ability to control the muscles. If that's the case then having 15 mA no trip threshold for RCCB won't protect the person. Please elaborate more on this.

    • @GKAgrawal2
      @GKAgrawal2  8 місяців тому

      There is time factor also to be considered. For how long we can afford shock without any jnjury, and how long breaker takes to trip. Read my article on "AC or DC, which Is more dangerous" for more detail in my website www.gkagrawal.com

  • @pankajsanwal2010
    @pankajsanwal2010 4 роки тому +1

    Sir please prepare a video in microprocessor release setting method of any air circuit breaker ( ACB) ? I think you will do . Thanks a lot .

  • @manojshelare6459
    @manojshelare6459 4 роки тому +1

    Sir maine 100 mh 25Amp rccb Gharme lagaya sahi hai ya galat plz. Ans. Me thank u

  • @ShivaprasadDabholkar
    @ShivaprasadDabholkar 3 роки тому

    Excellent and very helpful explanation. Thank you

  • @aruntechyoutube4316
    @aruntechyoutube4316 3 роки тому +1

    Nice...

  • @abhimanyualtekar7060
    @abhimanyualtekar7060 4 роки тому +1

    बढिया जानकारी

  • @rintu9080
    @rintu9080 3 роки тому

    It's very good

  • @bhawanishankarsharma2646
    @bhawanishankarsharma2646 3 роки тому

    Good explanation

  • @sumitchauhan7842
    @sumitchauhan7842 5 років тому +1

    Thak u sir u gave best knowledge.....

  • @gyanendrachamlingrai4413
    @gyanendrachamlingrai4413 3 роки тому

    Thanks for information about your experience.

  • @pccreation515
    @pccreation515 4 роки тому +1

    Great knowledge

  • @rakeshjaulkar5178
    @rakeshjaulkar5178 3 роки тому +1

    बहुत दिन से एसा ही कुछ ढूंढ रहा था

  • @ayushmanpadhy3497
    @ayushmanpadhy3497 5 років тому +1

    Great knowledge sir

  • @villagegallery8531
    @villagegallery8531 4 роки тому

    Pranaam sir, aapki har video se acchi information milta hei, kuch na kuch sikhne ko milta hei. ( sir ,ghar mein koi 30 mA - 25 Amp rccb use karta hei toh mcb kitna Amp ka use karna hoga???) Please boli ye ga sir.

    • @GKAgrawal2
      @GKAgrawal2  4 роки тому +1

      Yeh tho load per hai, but 25A sey jyada ka na hona chiyey.

    • @villagegallery8531
      @villagegallery8531 4 роки тому

      @@GKAgrawal2 rccb jitna amp ka hoga utna hi amp ka mcb lagega???

  • @mishalagrawal7032
    @mishalagrawal7032 2 роки тому

    Sir,
    Hotel use, Penal board(bus bar) se separate wire gaya hai only for geyser(2kw or 2000w) k lie, isme kitna mA ka rccb lagau.

  • @manukumar-wr7wx
    @manukumar-wr7wx 4 роки тому +1

    Good information

  • @somnathkundekar2790
    @somnathkundekar2790 3 роки тому +1

    धन्यवाद 🙏🙏

  • @harshpatel-ct8pr
    @harshpatel-ct8pr 2 роки тому

    Nice explanation
    In residence(4kw).... Which rrccb safe...

  • @bsrupa3396
    @bsrupa3396 2 роки тому

    Namastey sir. Grateful to you for your teaching. Can you please suggest a most reliable model tried and tested by you.

  • @AbhishekKumar-er4vr
    @AbhishekKumar-er4vr 3 роки тому

    Thankyou sir. Your video was really helpful.

    • @GKAgrawal2
      @GKAgrawal2  3 роки тому

      Also, You may not get this kind of information easly

  • @Ankit_M
    @Ankit_M 4 роки тому +1

    Sir RCCB lagane Ka Sequence Batao Detail Video me..,
    Aur advantage & Disadvantage Bhi Batao

    • @GKAgrawal2
      @GKAgrawal2  4 роки тому

      Watch my all other videos on RCCB

  • @alamfiroj-vlog.5451
    @alamfiroj-vlog.5451 4 роки тому

    Sir,nice your electrical. Video..milliampiear kya hota hai. Ples. Batao sir.

  • @rajeshmahakulkar5640
    @rajeshmahakulkar5640 5 років тому +2

    Very good sir

  • @CaracCompressor
    @CaracCompressor 3 роки тому +1

    Very nice 🔥🔥🔥

  • @chanduzalte8492
    @chanduzalte8492 3 роки тому

    बढ़ियाँ.. आज confusin दूर हुआ
    फिर भी एक प्रश्न है
    अगर series test lamp के दो point पकड़े तो rccb ट्रिप होगा?
    मतलब की जब मेरा शरीर bulb के series में रहेगा तब rccb ट्रिप होगा?
    धन्यवाद

    • @GKAgrawal2
      @GKAgrawal2  3 роки тому +1

      हाँ , कयोंकि पैर थरती को छुयेगा ।

    • @chanduzalte8492
      @chanduzalte8492 3 роки тому

      नहीं नहीं सर
      मैंने series के दोनो लीड मेरे दोनो हाथ में पकड़ रखी है.. और current मेरे बॉडी से bulb में जा रहा है… लेकिन मेरा पैर
      धरती को कही भी टच नहीं होगा तो?

  • @rahul_ee_19
    @rahul_ee_19 4 роки тому +1

    Sir, is there any need of earthing when we are using RCCB in building? Can we avoid the use of earthing as it increases the overall cost of wire?

  • @jaylegalbytes3211
    @jaylegalbytes3211 3 роки тому +1

    Great Sir

    • @GKAgrawal2
      @GKAgrawal2  3 роки тому

      This has exclusive information.

  • @hkfano362
    @hkfano362 4 роки тому

    Sir ager incomer.300ma hai output mai 30ma rcb hai.ager earth leakage.hota to.phelay kaunsa.trip hoga.thank a lot.aap ke jawab ka mujhe intejar rahega

  • @Arif-kz4fi
    @Arif-kz4fi 3 роки тому

    Ghar me invater single wire se wiring kiya hua hai to wanha rccb lagane se main our invater ka load chalega

  • @satishkumarmaurya7440
    @satishkumarmaurya7440 4 роки тому

    Sir inverter ki output se lekage hoga to usame rccb use kr sakte hai kya
    Please btaye ya 1 video bnaye

  • @VikasKumar-lx5di
    @VikasKumar-lx5di 5 років тому +1

    mst video sir ji

  • @debrajmazumdar325
    @debrajmazumdar325 2 роки тому

    Sir plz inform mee 1000 waat load '30mA' lagaye.?? Meri House mee.???

  • @jamivenugopal4768
    @jamivenugopal4768 2 роки тому

    Sir iam worked in r&d department electrical. Main db having elcb 63amps 100ma . In one distribution mcb 15amps that connected two switch boards. Without connected equipments mcb on condition elcb tripped what happen leakage current crosses 100ma ? Please answer me

    • @GKAgrawal2
      @GKAgrawal2  2 роки тому

      One possibility is that switch boards have problems like dust, moisture, cut wire etc

  • @kpjangir1903
    @kpjangir1903 Рік тому

    sir hme ghr m sari msb 16 ki 7 lgi hui h to kitne amp ki mcb lgay 30 mili to ho gya or amp kitna lgaay 32 ya 40

  • @harr992
    @harr992 4 роки тому

    Thanks sir . Sir ek bat puchni thi aap se .
    Rccb main types hote hai .
    A, AC , in main se home k liye kon sa sehi hai .

  • @patelparthmahendrabhai2951
    @patelparthmahendrabhai2951 4 роки тому

    good teaching

  • @NANA-gh8vh
    @NANA-gh8vh Місяць тому

    32amp mcb me rccb 30ampr lga skate h sir

  • @nisargkumar5912
    @nisargkumar5912 3 роки тому

    Sir main line me RCCB lga hua hai , ek hi neutral hai aur inverter se ek main wire hai to inverter ke output me RCCB and MCB lga sakte hain? Please batlaye.

  • @akashsenta3601
    @akashsenta3601 3 роки тому

    I going depth into ground leakage current increase or decrease?
    Please explain, sir

  • @KuldeepSingh-zk8eg
    @KuldeepSingh-zk8eg 3 роки тому

    sir plz reply . i am install RCBO L&T C63 300ma COMPANY arond 3 kw load my house plz suggest me 300ma 63 amp safe for human shock or i am install 40 amp 30ma RCBO

  • @jitu2089
    @jitu2089 5 років тому

    Sir ji mera doubt parallel operations of 2 generator pe h..... Maine kahi pe ye Padha h ki synchroscope ,synchronising switch k across connect hota h... ye Sahi h kya,,, or ye synchronising switch TPST switch h.....sir agar ye Sahi h to plz ye btao ki synchronising switch ya TPST switch ACB(air circuit breaker)me hota h kya.iska mtlb synchroscope ACB me connect hota h,,, plz reply sir

  • @MuthuKumar-xt8hr
    @MuthuKumar-xt8hr 3 роки тому

    Sir what is the maximum allowable current flow through human body

    • @GKAgrawal2
      @GKAgrawal2  3 роки тому

      Watch my exclusive video on AC or DC which is more dangerous. You will get the answer.

  • @MrSAHANSHEEL
    @MrSAHANSHEEL 5 років тому

    Good teaching method

  • @munaswain854
    @munaswain854 4 роки тому

    Sir meter to- 32A MCB, 30A RCCB to split AC to house canect , right sir bataye

  • @gulfwork6511
    @gulfwork6511 3 роки тому

    Super ❤️ babaji

  • @dilipsolanki3534
    @dilipsolanki3534 4 роки тому

    Very good video

  • @hemantvashist1906
    @hemantvashist1906 3 роки тому

    Sir 200 mamp ke load ke liye kitne amp ki MCB ya rccb use kar sakte h
    200 milli amp load hote hi rccb trip ho jaye please tell me sir

  • @av8480
    @av8480 4 роки тому

    Gharo mai Kitne RCCB use krna chaahiye....
    Aur uke connection kaise hone chahiye......?????????
    Please reply

  • @bhavinmaru4024
    @bhavinmaru4024 3 роки тому

    Great sir...

  • @babukartik6124
    @babukartik6124 2 роки тому

    Whether 500 ma is safer or 50ma?

  • @shakirelectrical7281
    @shakirelectrical7281 4 роки тому

    thanks great effort.

  • @clarkkent4872
    @clarkkent4872 2 роки тому

    Whether 30mA sensitivity RCCB trip when turning on submersible pumps?

    • @a.ksingh2244
      @a.ksingh2244 2 роки тому

      Yes bro.. but not when we press the green button.. it trips when the input power is supplied in starter... So, i have left the power plug switch for starter as always ON mode.. Then no problem at all

  • @pushpakbhangale2689
    @pushpakbhangale2689 5 років тому +2

    Hello sir,
    Electrical standard refer kane ke liye koi site hai to please link send kijiye.

    • @GKAgrawal2
      @GKAgrawal2  5 років тому

      BIS India, You will have to buy standards.

  • @metrohardwareandelectricst6097
    @metrohardwareandelectricst6097 4 роки тому

    Really good 🙏🙏

  • @nasi666
    @nasi666 3 роки тому

    Mere Ghar me 2 fridge, 5 fan , 4 tube light ,7 9waat ke bulbs hai 2iron press hai 3 led TV 3 wotar Hiter hai to muje kitne MM Ka wire our kitne Ahmper ki MCB our Rccb lagani cahi ye

  • @sk2953
    @sk2953 3 роки тому

    Sir mera ghar mei dp mcb 32A ka hai but uskei badd rccb laga hai jo ki 40A/100ma. Kya ampiear difference sei koi dikat hai or 100ma rcc sahi hai ya fir 40 ya 60 ma rccb sei change kardu

    • @GKAgrawal2
      @GKAgrawal2  3 роки тому

      40A ki koi dikkat nahi, RCCB 30mA ka hona chahiye.

  • @maheshmishra6902
    @maheshmishra6902 4 роки тому +1

    Sir 30 mA wali RCCB m agar residual current bd jaye 30 mA se upper ho jaye to RCCB trip hoga ya nhi???

    • @GKAgrawal2
      @GKAgrawal2  4 роки тому

      Trip hoga. Mera video RCCB breaker in Hindi dekho.

  • @sunilkumar-he3ey
    @sunilkumar-he3ey 4 роки тому

    Sir geyser 3kw use kartha hu instant geyser jo hay
    Ushmay kitnay amp ka rccb lgana hoga btaye pls

  • @SarkariResultsGyan
    @SarkariResultsGyan 4 роки тому

    Sir kya hum 1ho ki summersible me rccb ka istemal kar sakte hai?

  • @beasthawck5604
    @beasthawck5604 3 роки тому

    Hello sir, agar 16 amp rated rccb mein se 20 amp current flow karenge tab kya hoga. Please bataye

  • @balasahebwadewalemalipatil623
    @balasahebwadewalemalipatil623 5 років тому

    Sir Rccb lagane ke bad invhartr wiering kise kare is par jankari dedo.

  • @shivshankarsingh1402
    @shivshankarsingh1402 4 роки тому

    Hii, sir I have 3 AC 1 ton apart from other minor load like 3 led tv 1 fride 260 ltr , 1 washing machine 500 w , 1 induction cooktop . What rating RCCB to be used . And which one 3mA or 100 mA . Kindly reply sir

  • @patelbhavin007
    @patelbhavin007 5 років тому

    great video sir

  • @user-vd9ok7zd9i
    @user-vd9ok7zd9i 5 років тому +1

    Sir 25 amp rccb me agar 30 amp load lega to kya hoga ??

  • @mdaadilfiroz3525
    @mdaadilfiroz3525 4 роки тому

    Rccb lgata hon to kya main Mcb lgana hai ya nahi?

  • @user-ii1bp1ps3j
    @user-ii1bp1ps3j 3 роки тому

    Sir 7.5hp 3 phase motor ke liye kitne ampere ka rccb lgaye plzz Rply me sir

  • @goutomsamadder8651
    @goutomsamadder8651 4 роки тому

    Sir aap jenius ho

  • @sahilshaikh6290
    @sahilshaikh6290 Рік тому

    Mere ghar main l∆n 0.03 hai sir vo bahot trip hoti hain to 30 ml ka ripless karde kya

    • @GKAgrawal2
      @GKAgrawal2  Рік тому

      Koi equipment ghar kaa kharab hai. Shayad water heater. Ek, ek karkey sab equipment off karkey dekho

  • @dharmarajumredkar2764
    @dharmarajumredkar2764 2 роки тому +1

    कितने Amp का बिठाना चाहीये

  • @badalasingh9355
    @badalasingh9355 4 роки тому

    Nice video sir

  • @KHATU195
    @KHATU195 Рік тому

    Sir lod off krne pr v Mera Rccb trip hota hai
    Suddenly nhi 1hours.03hour
    Ame Kya krna hoga
    Factory me..

    • @GKAgrawal2
      @GKAgrawal2  Рік тому

      Shayad aap koi load ON kartey honge, usme leakage hogaa.

  • @gsriderktdbullet2630
    @gsriderktdbullet2630 Рік тому +1

    👍👌

  • @srikanthpradhan642
    @srikanthpradhan642 4 роки тому

    Rccb 30amp ka lagaye mcb kitna amp ka Laguna chahiye sir total watt 500 ho toh

  • @bhaskaryadav4884
    @bhaskaryadav4884 4 роки тому

    Thanks