Experiment With RCCB

Поділитися
Вставка

КОМЕНТАРІ • 201

  • @LetsSeeInside
    @LetsSeeInside  5 років тому +16

    Dosto ye video aap ko kesa laga jarur bataie !!

    • @AchintA2Z
      @AchintA2Z 5 років тому +1

      4 pole ka rccb me to sabi phase alag amp leti hai..to trip kiu nehi hoti???aap galat bata rahi hai....

    • @FirozKhan-zw2fb
      @FirozKhan-zw2fb 5 років тому

      Firoj9352426925

    • @jamshedsiddiqui3355
      @jamshedsiddiqui3355 5 років тому

      Sir ye batao neutral & phes joint hone se rccb trip kyu nah ihoti hai to rccb lagane se wiring ki kya sefty sirf urthing aur phes se hi joint hone se hi kyu hoti hai kya Folt aur current urthing aur phes se hi hota hai please reply

    • @umairgujjar5090
      @umairgujjar5090 4 роки тому

      jamshed shab nutrul our pase brne se short breker trip ho gi jinab earthing hone par arth examal agr ap ki koi fan ki wending short ho to earth breker trip ho g i

    • @raamkumar857
      @raamkumar857 4 роки тому

      Nice

  • @jeethuutube
    @jeethuutube 2 роки тому +2

    RCCB only works if both the lines are taken from its output. If not the RCCB trips itself. It is a way of indicating that the connections are not done properly.

  • @anoopgoel2225
    @anoopgoel2225 2 роки тому +1

    Added load of meter too

  • @kamleshyadav2640
    @kamleshyadav2640 3 роки тому +1

    Kabhi bhi nutal by pass nahi hota hai bhai. Erth likege se hota hai trip

  • @makwanavijay1200
    @makwanavijay1200 3 роки тому +1

    Brother RCCB and ELCB both have different working principles just like key ped phone and Android phone...

  • @vinayjaiswal9803
    @vinayjaiswal9803 5 років тому

    बहुत अच्छा वीडियो

  • @deepakkanojiya3108
    @deepakkanojiya3108 4 роки тому

    Bhai aap mcb dubal pool ke Rccb ka praise ky h 32 ampeyr frij me kitne ampr ka hona Chai ye

  • @engineerkohat
    @engineerkohat 4 роки тому +1

    Wonderful. Great information! Soon I will post a video on this item.

  • @mossalam3431
    @mossalam3431 3 роки тому

    Good information,keep it up

  • @anilsingh-qd2xo
    @anilsingh-qd2xo 3 роки тому

    आरसीसीबी को फसल वाली झटका मशीन की तरह प्रयोग कर सकते हैं क्या

  • @vipulgamitvg
    @vipulgamitvg 5 років тому +2

    *बल्ब को ON कंडीशन में रख कर दूसरे वायर से ऊपर नीचे के दोनों पॉइंट शॉर्ट करो।*
    *क्यों कि कोई भी इलेक्ट्रॉनिक डिवाइस स्टार्टिंग करंट ज्यादा लेती है।*

  • @sanjeen2503
    @sanjeen2503 3 роки тому

    Achha video tha, lekin RCCB ke standards ke hisaab se 15 mA pe bhi trip hona allowed hai. Alag alag current level pe alag alag time limit hota hai milliseconds mein. 100 mA me ~30 milliseconds allowed hoga, 15 mA pe 500 msec. 15 mA se kam pe trip nahin hona chahiye as per standards.

    • @sanjeen2503
      @sanjeen2503 3 роки тому

      Aap ek aur low power bulb (around 1 W) se try kijiye same experiment.

  • @areejanwar9725
    @areejanwar9725 4 роки тому

    Very good teaching welldown

  • @hannanpakthini7221
    @hannanpakthini7221 4 роки тому

    RCCB kee jaanch ke lie yeh karen:
    In coming connect karne ke baadh out going ke "Line" se aek dhoosraa wire connect karne ke baadh is ke dhoosre sare ko geelee zameen ko ch'hooyen tho RCCB trip hojanaa chaahie, yeh behadh surakshith aur b'harosamand thareeqa he.

  • @zeemixvideos6485
    @zeemixvideos6485 4 роки тому

    rccb stand for?

  • @NH-de3km
    @NH-de3km 4 роки тому +1

    Sir,,,jmd brand ka rccb ghar ke liye a66a rahega??????please sir reply

  • @zeeraak
    @zeeraak 5 років тому +3

    i've watched your video very caefully red and blue wires are connected to source input and the 2 black wires to load
    the RCD function to load and does not trip and when you bypass the load it trips something that is puzzling me where it should trip it doesn't and where nothing is connected it trips

  • @technicalcell2602
    @technicalcell2602 4 роки тому

    Bhai sahb is bulb men pcb card hota hy jis pe bht sary electronics components lgy hoty hn jis ki wja se start men zyada current ki jerk jati hy jo definitely 100mA se zyda hoti hy is liay breaker trip hota hy. Agr ap bulb ki jga koi variable resistance lga k current ko 100mA se km pass krwaen to ye ni hoga trip

  • @rakeshsevok
    @rakeshsevok 4 роки тому +4

    Rccb actual work leakage current me karta hai, apka experiment sahi nahi hai

  • @gantakrishna3069
    @gantakrishna3069 4 роки тому +1

    Sure

  • @sushantakumarhazra2314
    @sushantakumarhazra2314 4 роки тому +1

    Clear concept gained. Thanks

  • @skilkhk1753
    @skilkhk1753 4 роки тому

    Sir, i have a modification in RCCB. If we will done this modification in rccb then rccb work in main line with inverter single wire. If main line shut down then work rccb with inverter current.

    • @ankushaggarwal79
      @ankushaggarwal79 2 роки тому

      Agar ghr mai inverter laga ho to, kya main mcb kaam nhi krta hai kya?

  • @Jaswindersingh-tv4tj
    @Jaswindersingh-tv4tj 4 роки тому

    Bro what is the name of this digital meter
    And purchase link

  • @pawanduran
    @pawanduran 4 роки тому +1

    Agr ghr pr inverter h to RCCB ko kha connect krna h plz btaye

  • @hemantpharande2567
    @hemantpharande2567 4 роки тому

    Please make video on change over MCB.

  • @shyambabushah259
    @shyambabushah259 4 роки тому

    Rcn ko input niche ya upar se hoga hai...

  • @amarpalsinghsuper
    @amarpalsinghsuper 5 років тому +1

    Good job bro. Next video ka lntzar karunga

  • @mkrishnan8888
    @mkrishnan8888 4 роки тому

    Use electrical hand gloves also

  • @prakashsharma6186
    @prakashsharma6186 4 роки тому

    I have the same make 4 pole rccb and installed it. How to be sure that it will trip in case of accident. I connected a wire from phase of my 3 pin socket and touched it with wall. Rccb did not trip. Why

  • @vishwanathmehrotra8917
    @vishwanathmehrotra8917 4 роки тому +1

    What about 3 phase 4 pole

  • @johnsagayaraaj5249
    @johnsagayaraaj5249 5 років тому +1

    What is the display meter used. Would u let me know. Waiting for reply.

    • @LetsSeeInside
      @LetsSeeInside  5 років тому +1

      This is a Power monitor. link in description for more information.

    • @johnsagayaraaj5249
      @johnsagayaraaj5249 5 років тому

      @@LetsSeeInside thank you bro

    • @nasratbeg712
      @nasratbeg712 4 роки тому

      Kya yeh powar monitor
      votege power aur amr batata hai sir

  • @peermohamed7552
    @peermohamed7552 4 роки тому

    What is the difference between 100 and 300 mA

  • @ajaykumarkushwahakumar8662
    @ajaykumarkushwahakumar8662 5 років тому

    Sir Bohot achi bata ye hai MCB avr RccB ka kitna ka fark hai

  • @skdhiman8401
    @skdhiman8401 2 роки тому

    Bhai, ye red colour me Flipkart ki JMD rccb order kri hai, iske button dusri side h.. kya bta sakte ho orginal h ya nhi

  • @prave2njha
    @prave2njha 4 роки тому

    Rccb aur elcb alag hota hai sir.
    Elcb mein earthing wire k extra terminal hote hai and elcb uska current sence karta hai.
    Rccb live and neutral k difference current ko sense karta hai.

  • @amazingvideos6572
    @amazingvideos6572 2 роки тому

    Bhai kon company ka rccb best hota hai aur kiya hum 63amp aur 30milliamp ka rccb use kar sakte hai bhai reply de please bhai reply me

  • @mdahmad7698
    @mdahmad7698 4 роки тому

    Nice video

  • @bijayshaw1224
    @bijayshaw1224 4 роки тому

    Apna mitar hata kar test karo bhai

  • @JM-zl8bi
    @JM-zl8bi 5 років тому +1

    Rccb line me connect karne bad MCB ki jarurat he?

  • @sumitmaheriya4211
    @sumitmaheriya4211 4 роки тому

    A company ki rccb achhi ati Hain?

  • @ChandanKumar-oh4ri
    @ChandanKumar-oh4ri 4 роки тому

    RCCB kis company ka sabse best aata hai

  • @avimango46
    @avimango46 5 років тому

    RCCB और ELCB दोनो एक जैसे नहीं होते !

  • @FreeCircuitLab
    @FreeCircuitLab 5 років тому +5

    Bhai sabdhani se kaam karma next part me,(lagta h shock khayenge aap)
    Aur bataiye yeh RCCB ki offline market price kitna hai?

  • @rajivmetal
    @rajivmetal 5 років тому +1

    Market me kitna kitna Amp ka RCCB milta hai? Or price kitna se start hota hai?

  • @ajaybnl
    @ajaybnl 5 років тому

    Arre bhai sahab RCCB Shock se bachne ke liye hota hai.

  • @vijaybhaipatil4735
    @vijaybhaipatil4735 3 роки тому

    घर में कितने Amp की आरसीसीबी लगाए , सिंगल फेज पावर में ?

  • @inderpalsingh1426
    @inderpalsingh1426 5 років тому +1

    Sir rccb ghar me two lagani padege one inverter one for main???

  • @commentonvideo
    @commentonvideo 2 роки тому

    Bhai kya jeebh lagaa kar test Karna tha kya..........

  • @pankajparmar6070
    @pankajparmar6070 5 років тому

    क्या प्राराइस है....☺

  • @jijikocharekar8447
    @jijikocharekar8447 4 роки тому

    Nice sir

  • @vigneshkumarbe8258
    @vigneshkumarbe8258 4 роки тому

    will harmonic current affect rccb function since some harmonics produce zero sequence current ...

    • @SwitchgearTrainingClasses
      @SwitchgearTrainingClasses 3 роки тому

      Definitely Harmonic affect in RCCB working but some company make special RCCB for that kind of application

  • @sanjaypadale3278
    @sanjaypadale3278 4 роки тому

    मजा नही आया
    जब phase बॉडी को touch होता हैं तो ट्रिप होता हैं या नही ये दिखाना चाहिये था
    ताकी हम इसे खरीदी कर सके

    • @SwitchgearTrainingClasses
      @SwitchgearTrainingClasses 3 роки тому

      Is video me sahi btaya gya hai kyo aap test button ki madad se be check kr skte hai

  • @faiyazkhan08
    @faiyazkhan08 4 роки тому

    Sir Agar ghar may 3 led tube light 3 9volt led bulb 1 iron led tv aur refrigerator iske lia kitne ampier ka RCCB lena hoga

  • @TECH-known
    @TECH-known 4 роки тому

    16 amp ka mcb me gharka kitna load or kya kya chala sakte hai

  • @asdfg-qu6go
    @asdfg-qu6go 4 роки тому +1

    Ye digital meter kon sa he
    Ye meter mujhe Lana he

  • @horedey2994
    @horedey2994 4 роки тому

    Vii 25A mcb ka sat kitna amp ka rccb lagana ha

  • @niladrinaskar6596
    @niladrinaskar6596 4 роки тому

    House warning main ketna amper ke elcb hona chiya?

  • @bikasKumar-ot1tf
    @bikasKumar-ot1tf 4 роки тому

    Search protection device main ek video banai

  • @noutyboymali3928
    @noutyboymali3928 5 років тому +1

    आपके पास जो मीटर हैं उसका नांम ?
    Price?

  • @deeppatel9624
    @deeppatel9624 3 роки тому

    thanks bro

  • @kundan9902
    @kundan9902 4 роки тому

    Hello dear, your rccb is totally defective as per leakage current ratting.

  • @technicalsaumil3938
    @technicalsaumil3938 5 років тому +1

    Rccb Kitna ka liye ho bhai market se

  • @DharmendraKumar-ep1ei
    @DharmendraKumar-ep1ei 4 роки тому

    Sir kya ye double phase agricultural monoblock pump pe work karega kya?

    • @engineerkohat
      @engineerkohat 4 роки тому

      Yes you should use three phase version of this.

  • @durgeshyadav-yg6qf
    @durgeshyadav-yg6qf 5 років тому

    Appne jo mitar use Kiya hai uska Keya name h

  • @mybharat-sr7sq
    @mybharat-sr7sq 4 роки тому

    Sir series canicsan kysa huta hai

  • @AnilKumar-uk1fs
    @AnilKumar-uk1fs 4 роки тому

    Kya rccb ka electric water rod me use KR sakti h Kya , protection k leya

  • @electricbanglahelp
    @electricbanglahelp 5 років тому +1

    Good video 👍👍

    • @m.s.sharukhkhan5923
      @m.s.sharukhkhan5923 5 років тому

      Rccb trep kregee 75 mm wayar sot hone se bhi trep ho jate h

  • @suryaselvaraj3209
    @suryaselvaraj3209 4 роки тому

    sir i have one doubt short circuit and over load time rccb will trip or not?

    • @engineerkohat
      @engineerkohat 4 роки тому

      Sure. It is a circuit breaker with extra feature.

    • @hannanpakthini7221
      @hannanpakthini7221 4 роки тому

      @@engineerkohat ... I differ u. Not all RCCBs have Overload tripping.

  • @RajeshKumar-kg6nl
    @RajeshKumar-kg6nl 5 років тому

    इस प्रक्टिकल के लिये elcb teste लेना चाहिए उस पर मिली एम्पियर मैं रेटिंग होती हैं

  • @shashankr5988
    @shashankr5988 5 років тому

    Sir which resistence its inside sir?

  • @sanjaytamang2187
    @sanjaytamang2187 5 років тому

    Sir MERA pass 10kva ka gernitor Hai kya me gernetor ki safe ki liye gen set ki out put me kitna ampire ka mcb lagna hai our kun se mcb lagana hai plz reply

  • @dharmveermandal3674
    @dharmveermandal3674 2 роки тому

    Shoket ke upar Jo lagaye hai usake name

  • @sahilmehta27097
    @sahilmehta27097 5 років тому

    Rccb ko inverter output me kaise connect kare usme sirf line out hota hai neutral to hotta nahi?

  • @yasirmehmood6669
    @yasirmehmood6669 4 роки тому

    RCCB ko agr solar k bd inertor sa jo out nikalti h us ma lgay r neutral na lien to ya kam kray ga ya ni ,,,,

  • @chandangantayat7068
    @chandangantayat7068 3 роки тому

    100ma matlaba kya he sir , kucha pata he kya

    • @SwitchgearTrainingClasses
      @SwitchgearTrainingClasses 3 роки тому

      100mA means = 0.1A
      Basically ish sensitive rating ki RCCB commercial or offices me use karte hai

  • @adarshsoni4652
    @adarshsoni4652 5 років тому

    Video to Jhakass hai

  • @saifmalikbarabanki8033
    @saifmalikbarabanki8033 5 років тому

    ek bat samajh me nahi aa rahi hai RCCB se MCB me कनेक्शन diya to erth lagne par pahle MCB trip karega ya RCCB

    • @hiteshvariya9827
      @hiteshvariya9827 5 років тому

      Rccb karega because current differences two phase or neutral me aya he wo sif 100ma he while Mcb to short circuit me treap hogi

    • @saifmalikbarabanki8033
      @saifmalikbarabanki8033 5 років тому

      @@hiteshvariya9827 thank you so much

  • @electro7939
    @electro7939 4 роки тому

    Thank You sir 💐❤️

  • @sunilkumar-he3ey
    @sunilkumar-he3ey 5 років тому

    Sir 2kv aur 3 kv kay load pay rccb kitnay amp ka hona chahiye
    Agar 3kv kay hisab shay rccb lgaya jaye toh ghar par kisi member ko current lga toh kya rccb trip hogi kya btaye pls
    chahiye jyada shay jyada amp ka rccb ghar par install hay
    Toh rccb trip hogi agar ghar mein kisi member ko current ata hay jayshay fridge mein kabhi kabhi current lagtha hay toh kya rccb trip hogi btaye pls

  • @yashvardhansingh1228
    @yashvardhansingh1228 5 років тому

    Bhai yah sab experiment Mila hai UA-cam channel per

  • @venkataramana-vr1jj
    @venkataramana-vr1jj 5 років тому

    Hello sir this one using the battery charging process reverse polarity

  • @sunitmahapatra9841
    @sunitmahapatra9841 5 років тому

    Dost e jo rccb ke baad board lagaya hai or uske baad jo device lagaya hai oo keya hai

  • @chandanchauhan4938
    @chandanchauhan4938 5 років тому

    Nice

  • @nirmalvaniya6093
    @nirmalvaniya6093 5 років тому

    What's is different RCCB & RCBO.
    How to check practical Trip function

    • @SwitchgearTrainingClasses
      @SwitchgearTrainingClasses 3 роки тому

      RCCB only for Leakage current protection
      But RCBO gives Overload, Shortcircuit and Leakage current protection

  • @raisahmedshaikh8634
    @raisahmedshaikh8634 5 років тому

    Nice,

  • @kotlilive
    @kotlilive 5 років тому

    This is a RCD (residual current device) not RCCB (residual-current circuit breaker )

  • @mohammedbd1698
    @mohammedbd1698 4 роки тому

    Thanks

  • @gunneetsingh1232
    @gunneetsingh1232 4 роки тому

    bhai 100mA ka mtlb h if koi particular load agr 2 amp le rha h and continueous 2 amp ja rahe h rccb se and kisi ke touch krne se wo 2000 mili amp agr 2100 milli amp jane lg gye to wo trip hogi. ye experiment to useless tha bhai meko to smjh hi ni aya iska motive 😅 rccb sirf trip krke dikha rahe ho app isse kya proof hua ?

  • @khageswarnayak2177
    @khageswarnayak2177 5 років тому

    Rccb through a/c chala skate hain

  • @shashankr5988
    @shashankr5988 5 років тому

    Sir kithna k ohm ka resistene iska ander he?

  • @Deepakkumar-wh9ne
    @Deepakkumar-wh9ne 5 років тому

    Wo meter kaunsa hai

  • @kamleshkunvariya120
    @kamleshkunvariya120 5 років тому

    Nice guidance ELCB

  • @birendranegi419
    @birendranegi419 5 років тому

    घर के कितने RCCV कितने एम्पीयर कि लगवायें

  • @abdullashaik8489
    @abdullashaik8489 5 років тому

    Please change your bypass connection test onese phase bypass please

  • @vivekkumarmishra3876
    @vivekkumarmishra3876 5 років тому

    Sir aik 100 ml amp ka rccb 2 pol ka hai but o trip kr ja rha hai bar bar, aior jb rccb ko jb Bay pas karke mcb ko on karte hai to bilkul sahi chal rha hai, please btaiye n kya karu SIR

  • @suvankardas4431
    @suvankardas4431 4 роки тому

    Rccb input output বুঝবো কি রকম বলো দাদা

  • @atikkhan2957
    @atikkhan2957 4 роки тому

    Sar inwarter ki wyring kisye kary Rccb me csnfuz hu

  • @mukeshmixingnirmali8088
    @mukeshmixingnirmali8088 5 років тому

    Sar mera rccb jmd kampani Ka hai 40 mp hai par tip nahi karte par tipar kam karte hai

  • @Ankit_M
    @Ankit_M 5 років тому

    Sir Bohot Hi Achhi Information Di,
    Aur RCCB Ko Energy Meter Ke Baad Ghar Me Lgane Ka Sahi Sequienc Aur Kitne Load Ki Lagegi ispar Bhi Detail Video Banaye

  • @shaik.humayoon9969
    @shaik.humayoon9969 4 роки тому

    👌boss