How to connect armed and disarmed LEDs to your IDS x-Series alarm system - with tutorial

Поділитися
Вставка
  • Опубліковано 9 січ 2021
  • How to connect armed and disarmed LEDs to your IDS x-Series alarm system

КОМЕНТАРІ • 18

  • @duncangeach8970
    @duncangeach8970 Рік тому +1

    Clear and concise. Thank you for this value adding tutorial

  • @selebogorichardmolebatsi4209
    @selebogorichardmolebatsi4209 2 роки тому +1

    U tube helped bigtime with regard to my job and other things...

  • @warrenpfo
    @warrenpfo 3 роки тому +2

    Thank you. Very helpful as always I will be doing this over the weekend.

    • @warrenpfo
      @warrenpfo 3 роки тому

      Quick question can dc power run 75m to power the led's or will i get too much voltage drop and rather should i put a secondary power supply in my garage rather than try feed it off the alarm panel in the house.

    • @ecologicaltime
      @ecologicaltime  3 роки тому +1

      for LEDs 75meters is fine, if you use quality cable (copper) you should have no issues.

  • @hencoannandale5895
    @hencoannandale5895 3 роки тому +1

    Done and dusted. Thank you once again for an awesome explanation. Enjoy
    Ecologicaltime projects.

  • @sexualposition
    @sexualposition 3 роки тому +1

    Excellent video.

  • @jaars911
    @jaars911 Рік тому

    Please do a tutorial on how to use the programmable outputs on 805

  • @caswellndlhovu8990
    @caswellndlhovu8990 2 роки тому

    Thanks for the video, is it possible to program an output to give 12V when alarm is ready? I want to connect a relay to allow me to see if alarm is ready via relay action.

  • @amybulteel4764
    @amybulteel4764 Рік тому

    Hi! I’m trying to figure out why my alarm forces me to bypass my outside beams before arming?
    We want the beams on and connected to the alarm system but cannot see how to do that. The alarm says “not ready to arm” with the outside beams zone number.
    Thanks so much for your help.

  • @wianbotha5979
    @wianbotha5979 2 роки тому

    Hi, can i add a Led without a relay? I just need to show when ita arm on on stay arm. Do i then need a resistor ?

  • @plonkster
    @plonkster 3 роки тому

    Sadly I don't have the nice LCD panel. I have the simpler panel. I've programmed Paradox and Texecom alarms myself but this one has me a little stumped. Trying to set one of the programmable outputs to follow so I can read that with an ESP8266 WiFi chip (through an opto-coupler) to incorporate into homeassistant.

    • @plonkster
      @plonkster 3 роки тому +1

      Aaah nevermind. If I read it properly in binary it says "34" which is the PGM output on the first keypad. Seems I can only have one output assigned to this event. That's a pity.

  • @jimhoward1655
    @jimhoward1655 2 роки тому

    Does anyone sell this premade and ready to install?

  • @shahengovindpershad8599
    @shahengovindpershad8599 3 роки тому

    Hi my alarm led turns green on away arm only but not stay arm. How do you activate to turn on for stay arm as well?

    • @ecologicaltime
      @ecologicaltime  3 роки тому

      it is shown in this video

    • @caswellndlhovu8990
      @caswellndlhovu8990 2 роки тому

      Hi, I also have the same issue, away armed is fine, but stay armed does not activate the output, is there some additional config for 12V on the output? I also need a 12V output for chime zones so I can trigger my Google speakers to announce if I have someone outside the house.