API 6A HYDRO TEST PSL 1. Wellhead gate valve hydro test. How to pressure test a valve. Valve testing

Поділитися
Вставка
  • Опубліковано 30 лип 2024
  • #valves #oilfieldvalve #API6A
    Welcome to everything valves. The channel dedicated to everything valves. Thanks you to everyone supporting the channel. If you find these videos helpful please like and subscribe.
    This video shows an API 6A PSL 1 hydro test being performed on a 3-1/16" 10,000 psi gate valve. Sometimes before these valves go out into the field. The user will want to have the valve tested.
    The procedure used in this video is customized to fit this field testing facilities capabilities. The requirements follow the API 6A specification for PSL 1. Different facilities can perform the test using different equipment but will follow the same API requirements.
    These gate valves are pretty straight forward. I hope this breakdown shows you how a PSL 1 test is performed on a valve. If you enjoyed this video please like and subscribe. If you have any suggestions for future videos please comment down below.
    Check out more valve videos here.
    / @everythingvalves
    For more valve information. Please visit the link below.
    theaitg.com/

КОМЕНТАРІ • 22

  • @MD.RustamAli-qj6uh
    @MD.RustamAli-qj6uh 3 місяці тому +1

    Nice video

  • @MD.RustamAli-qj6uh
    @MD.RustamAli-qj6uh 3 місяці тому +1

    thank you sir

  • @user-qx2ik7hg8h
    @user-qx2ik7hg8h 3 роки тому +1

    Great
    Can you provide other details about the test and The rest of the tests

    • @everythingvalves
      @everythingvalves  3 роки тому +1

      Thanks for the reply. I plan to make more testing videos soon. They will provide more details on how perform pressure tests. Stay tuned. Thank you very much for watching.

  • @satyeshsetty1569
    @satyeshsetty1569 3 роки тому +1

    Very informative video, Appreciate :)
    but only one thing I was not clear, I believe you said rubber gasket in between valve and flange, I think it should be metal seal right? Ex: BX, Rx seal??

    • @everythingvalves
      @everythingvalves  3 роки тому +2

      Thanks for your support. That is a good point you bring up. When the valve is going to be installed for service you would use a metal ring groove gasket. You are correct. However when we perform test on the valves we do not like to use the metal rings for 2 reasons. First the metal rings are expensive and when only function testing the valves there is no need to waste them. 2nd sometimes when you use the metal rings and torque them down. You can damage the ring groove which would then cause the valve to leak in the field. These 2 reasons are why we use a rubber or other polymer type gasket when we test. Hope that cleared up your questions. Thank you for watching.

    • @ahmedanwar4586
      @ahmedanwar4586 7 місяців тому

      This is slab gate valve

  • @vickyvignesh6194
    @vickyvignesh6194 8 місяців тому

    METAL TO METAL SEAT LEAKAGE ALLOW OR NOT

  • @haider63530
    @haider63530 4 місяці тому +1

    Hi can you explain what PSL is? I didn't find a definition and I need to know its benefit. Thank you

    • @everythingvalves
      @everythingvalves  4 місяці тому +1

      There are 3 different PSL or (PRODUCT SPECIFICATION LEVELS). The higher the level the more inspections, documentation and resources are required. If you search one of my other videos API 6A pressure testing procedure. I reference some of the psl requirements. Hope this was helpful. Thank you for the comment.

    • @haider63530
      @haider63530 4 місяці тому

      @@everythingvalves Thanks a lot. indeed I saw another video of yours and I got it, do you have any video mentioning the performance requirements (PR)?

  • @binzhao3552
    @binzhao3552 Рік тому +1

    Obviously, this valve was filled a lot sealant before hyd test, as to the present of sealant, it is hard to know if this valve past test.

    • @everythingvalves
      @everythingvalves  Рік тому

      I appreciate your comment. These gate valves utilize grease it’s a pretty common thing. If the valve truly had a seat issue grease or no grease you would see the H2O passing the seats. If you have a different method you use for these valves I would be interested to know. Thanks again for the comment.

  •  10 місяців тому

    Machine shop ffff servises 24/7

  • @tembangwenya3908
    @tembangwenya3908 3 роки тому +1

    Gearler

  • @sparksagar1
    @sparksagar1 3 роки тому +1

    I guess, the hydro test is not to be done on a painted valve body, as shown in your video.

    • @everythingvalves
      @everythingvalves  3 роки тому +1

      That is a good question. Depending on the customer requirements. It is good practice to hydro test unpainted valves. That way if there are any body imperfections you would clearly spot them. If you look in the API 6A spec it gives more details about testing. Thanks for watching.

  • @samsulhuqkhanchoudhari607
    @samsulhuqkhanchoudhari607 Рік тому +1

    Hello

    • @everythingvalves
      @everythingvalves  Рік тому

      Hello to you too sir. Thanks for the comment and support. Have a great day.

    • @perdesh1990
      @perdesh1990 10 місяців тому

      PSL 3G REQUIREMENTS
      CAN WE TEST WITH WATER

  • @Nick_papagiorgio_
    @Nick_papagiorgio_ 9 місяців тому +1

    That’s not a gate valve :/