CSI SAFE - 22 Strap Foundation

Поділитися
Вставка
  • Опубліковано 15 гру 2024

КОМЕНТАРІ • 51

  • @civilmdc
    @civilmdc  5 років тому +3

    To make a RELATIONSHIP, Don't forget to press the subscribe button with bell icon to get the latest notifications. My channel :)
    ua-cam.com/channels/w9kSuR1bTFBmaMEyD_DXvQ.html

  • @BashirAhmed-jo4zq
    @BashirAhmed-jo4zq 3 роки тому

    Really Appreciate your Series of videos on different softwares. Nice job dear

  • @manik.c834
    @manik.c834 Рік тому

    Excellent... expecting more videos . Thank you engineer .

    • @civilmdc
      @civilmdc  Рік тому

      Welcome
      Here is the full course link on CSI SAFE
      ua-cam.com/play/PL0h14oMuZXQ6l-O7aqF0hYsZbyJ7eFt1H.html

  • @SantiagoGomez-ih6rg
    @SantiagoGomez-ih6rg 3 роки тому +1

    Thank you. I wonder if it´s wrong to include a linear subgrade modulus in the beams in edge column case.

  • @asangajurel8558
    @asangajurel8558 4 роки тому +1

    If we don't check the punching, how do we determine the depth of footing? Can you please elaborate??

  • @awasay5
    @awasay5 4 роки тому +1

    I appreciate your efforts...But I want to clarify one big doubt ....As per the codes it is recommended to provided only one layer i.e bottom layer of reinforcement ...Experts say that the upper layer of reinforcement don't contribute in further increasing flexural capacity ...Also considering the economical side ...I just want to provide the reinforcement as bottom mesh for the eccentric or edge footing ...Could you please suggest how to deal with this situation .......

  • @dennysnjagy9134
    @dennysnjagy9134 3 роки тому

    Amazing. Tuned in from Kenya

  • @engayedalayed7004
    @engayedalayed7004 4 роки тому +2

    PLS MAY I GET CLARIFICATION ABOUT K SPRING COMPUTATION. BECAUSE WE USUALLY COMPUTE IT BY THIS FORMULA ( ALLOWABLE B.C*120 -AS SI UNITS )
    EX: IF ALLOWABLE BC =200KN/M3 THE K =200*120=24000 KN/M3) IS THIS PROCEDURE CORRECT OR NO

    • @civilmdc
      @civilmdc  4 роки тому +1

      I got your question.... That is also one method...
      Here is the full course link on CSI SAFE
      ua-cam.com/play/PL0h14oMuZXQ6l-O7aqF0hYsZbyJ7eFt1H.html
      and here is the lecture, where i have discussed about both method... Basic and Bowl's Approach method
      Link: ua-cam.com/video/NDfeQt8x4VY/v-deo.html

  • @markcanicula
    @markcanicula 4 роки тому +1

    what if it the column is eccentic on both x and y direction i mean the column is on the corner edge of the property line. is it possible to design the whole perimeter strap beam due to the lot is small and need all column to be on the edge of property line. thanks

    • @civilmdc
      @civilmdc  4 роки тому

      Yes it is possible

  • @erimoro3
    @erimoro3 5 років тому +1

    Excelente video, explicacion muy clara, gracias ingeniero

  • @md.ashrafulalam4732
    @md.ashrafulalam4732 4 роки тому +1

    How can i design these kind of footing in safe if i done the analysis of the building in etabs?

    • @civilmdc
      @civilmdc  4 роки тому +2

      Here is the full course link on CSI SAFE
      ua-cam.com/play/PL0h14oMuZXQ6l-O7aqF0hYsZbyJ7eFt1H.html

    • @md.ashrafulalam4732
      @md.ashrafulalam4732 4 роки тому

      @@civilmdc Thanks

    • @md.ashrafulalam4732
      @md.ashrafulalam4732 4 роки тому +1

      One thing, i have done analysis and design of a 6 storied building in etabs. Now i have to design foundation. So how can i design the foundation of the building in SAFE from ETABS file that's i wanted to know. I have seen the playlist you shared and i don't understand which one is needed me. I am in shorting time. It will be very helpful if you please specify the link of the tutorial.

    • @civilmdc
      @civilmdc  4 роки тому +1

      @@md.ashrafulalam4732 CSI SAFE 20 AND 21 Lecture

    • @md.ashrafulalam4732
      @md.ashrafulalam4732 4 роки тому

      @@civilmdc May Allah bless you.

  • @surajgurung5856
    @surajgurung5856 4 роки тому +1

    While Applying the column load, Should we use factored load or unfactored load?? help plz.

    • @civilmdc
      @civilmdc  4 роки тому

      Unfactored loads.....
      And bearing pressure... Use Allowable bearing pressure

    • @surajgurung5856
      @surajgurung5856 4 роки тому

      @@civilmdc while in manual calculation of raft foudation, stress on soil, sigma (6)= P/A + Mx/Iy + My/Iy, which load should we use, P, Mx, My factored or unfactored???? plz help

  • @engr.md.titumirhasan5595
    @engr.md.titumirhasan5595 4 роки тому

    Sir, In foundation design why consider only service load combination not ultimate factored load combination. in load combination what should check using ultimate load combination. From Etabs should we take only dead and live load why not seismic load effect. pls sir.

  • @allinfo321
    @allinfo321 5 років тому +1

    When I check Punching Shear it says "N/C" not calculated. Please help

    • @civilmdc
      @civilmdc  5 років тому +3

      Software will never calculate punching shear for strap foundation (A foundation connected with beam).
      Because beam will restrict the punching... it will restrict the punching of foundation......
      For Example: If you have slab and columns only (Means with no beam), then there is a chance of punching shear,...........
      But if you have slab with beams and columns... there is almost no chance of punching.
      I hope this will clear your question.

  • @ILOVEUSAFIFTY
    @ILOVEUSAFIFTY 5 років тому +1

    Thank you, Bro!

  • @ILOVEUSAFIFTY
    @ILOVEUSAFIFTY 5 років тому +1

    Bro! You're from which country (If you don't mind)?

    • @civilmdc
      @civilmdc  5 років тому +1

      No issue... from Pakistan

    • @ILOVEUSAFIFTY
      @ILOVEUSAFIFTY 5 років тому

      @@civilmdc am also from Pak...Thanks anyways...Bro

  • @Johnny-pz3ch
    @Johnny-pz3ch 4 роки тому

    Thank you kind sir!

  • @roshansharma1655
    @roshansharma1655 5 років тому +1

    why have the punching shear design not checked needed some clue??

    • @civilmdc
      @civilmdc  5 років тому

      I have watched the video again.
      I forgot to check the punching shear check...
      It is simple to check shear check..... And you have to Must check the punching shear check....
      For that.. Go to display and select.. Punching Shear check...
      You will see the details of punching shear check.

    • @civilmdc
      @civilmdc  5 років тому

      I have watched the video again.
      I forgot to check the punching shear check...
      It is simple to check shear check..... And you have to Must check the punching shear check....
      For that.. Go to display and select.. Punching Shear check...
      You will see the details of punching shear check.
      If you still face any issue please let me know

    • @roshansharma1655
      @roshansharma1655 5 років тому

      @@civilmdc can i get to know if the N/C comes after checking the punching shear. Even after changing the footing thickness the punching shear did not come less than 1.
      how can we make it less than 1 .
      any suggestion or further video would be fruitful for all the viewers.

    • @fadifadi-ug5cp
      @fadifadi-ug5cp 5 років тому

      @@roshansharma1655 n/c means punching shear is not calculated because beams prevent slabs from punching.

  • @shaheershafat4599
    @shaheershafat4599 3 роки тому

    What about shear reinforcement in beam.

    • @civilmdc
      @civilmdc  3 роки тому

      You can also check.

    • @shaheershafat4599
      @shaheershafat4599 3 роки тому

      @@civilmdc where ?? Pls help

    • @civilmdc
      @civilmdc  3 роки тому

      @@shaheershafat4599 display, go to show beam design...

    • @shaheershafat4599
      @shaheershafat4599 3 роки тому

      @@civilmdc Display type to transverse rebar?

    • @civilmdc
      @civilmdc  3 роки тому +1

      @@shaheershafat4599 Yes

  • @Kniightwolff
    @Kniightwolff 19 днів тому

    This is 16 not 22 👎

    • @civilmdc
      @civilmdc  17 днів тому

      @@Kniightwolff it is lesson number 22..
      Here is the full course link on CSI SAFE
      ua-cam.com/play/PL0h14oMuZXQ6l-O7aqF0hYsZbyJ7eFt1H.html