RCC Column Size for 2 Storey Building & 3 Storey Building | Standard Column Size | column dimensions
Вставка
- Опубліковано 8 лют 2025
- RCC Column Size for 2 Storey Building & 3 Storey Building | Standard Column Size | column dimensions
घर बनाते समय कॉलम की साइज क्या रखे? Column Size for Construction:
कॉलम घर का एक महवत्पूर्ण अंग है. कॉलम घर के बीम और स्लैब का लोड लेता है और उसे फोडेशन तक पोहचता है. कॉलम की साइज गलत होने से घर की दीवारों में और स्लैब में क्रैक पड़ते है
सबसे ज्यादा उपयोग में ली जाने वाली “कॉलम साइज” (Column Size)
1) Column Size = 9” X 9”
2) Column Size = 9” X 12” (Recoomanded)
RCC Column Size for 2 Storey Building & 3 Storey Building and More:
1) Only Ground Floor - 9” x 9” - 230 x 230
2) Ground + 1st Floor - 9” x 12” - 230 x 300
3) Ground + 2 Floor - 12” x 12” -300 x 300
Disclaimer: This is just a guideline take your decision after taking advice from your structural designer. (यह केवल एक दिशानिर्देश है जो आपके संरचनात्मक डिजाइनर से सलाह लेने के बाद आपका निर्णय लेता है।)
Download Excel Sheet for 1000 sqft: cutt.ly/3xrFmXv
Concrete Mix Design Excel Software: bit.ly/3ljfu0k
House Construction Cost Calculator App: rb.gy/p2czsh
House Construction Cost Calculator Excel Sheet: bit.ly/2SpyiOu
Read More:
1) Free Download House Construction Cost Calculation Excel Sheet - bit.ly/2P9ZfVp
2) Free Download Slab Steel Quantity Calculation Excel Sheet - bit.ly/3bOYsmx
3) Free Download Building Estimation Excel Sheet - bit.ly/37IJ5Jc
4) Free Download Bill of Quantity Excel Sheet - bit.ly/2V4igfI
5) Free Download Bar Bending Schedule Excel Sheet: bit.ly/2uYz3Go
6) Free Download Column Design Excel sheet - bit.ly/32awf59
7) Building Bye-Laws for Planning - bit.ly/2vPw2bs
Watch More:
1) How to Draw Floor Plan by Hand: • How To Draw House Plan...
2) How to Draw House Plan Step by Step Method: • how to draw house plan... (450k views)
3) How to Draw House Plan Easiest Method: • how to draw house plan... (36k Views)
4) House Plan Drawing Step by Step(Most Popular Video on UA-cam): • How to draw house plan...
Also Watch:
1) Staircase Reinforcement Calculation || Full Estimate in Excel Sheet: • Staircase Reinforcemen...
2) Construction Estimating Using Excel || Free Download Excel Sheet: • Full Building Estimati...
3) House Construction Cost ¦¦ Calculate Cost in Excel sheet: • House Construction Cos...
4) Building Material Price ¦¦ Construction Labour Rate: • Building Material Pri...
5) How to prepare Bill of Quantities (BOQ): • How to Prepare BOQ | ...
6) How to Calculate Load on Column: • How to Calculate Load ...
7) Full Building Estimation in an Excel sheet: • Full Building Estimati...
Visit My Website: civiconcepts.com
My Facebook Page: / civiconcept
My Twitter Account: / civiconcepts1
My Instagram Account: / civiconcepts
My Linkedin Account: / civiconcepts
Disclaimer: -
The videos you are watching on my channel, I am uploading these videos just to give you an idea,
These drawings are made just to give an idea and not to challenge anyone.
I will give you just a proposal drawing. All idea mentioned in the video is to help people only.
#columnsize #RCCcolumnsize #civiconcepts
Sir, all ways your all video are informative.
Best consultant
1:43 Video concept started from.
सर् मेरे घर के कॉलम का साईज 9×9 हैं और 350 scq feet का हैं फुटिंग 3 फीट हैं और कुल 11 कॉलम हैं तो ऊपर मकान बना सकते है
Please reply sir kindly
10"×10" colum me g+1 bana sakte hai?
Mera thekedar bol raha hai 10×10 ka kolam dane k liye ... G+1 ka .. kiya ye thik hai ? 16 mm 2 or 12mm ka 4 sariya dane bol raha hai
G+2 k liye 9/12 de sakte h
Very nice
Nice video
Thanks
G+1 ghar banana hai. Colum ka size 9"×12" Rahega. Colum to colum width and length ka distance kya hona chahie? Please batana sir.
Agr column na bnaya ho plinth beam and door lenter ho to kya 1st and 2nd floor bna skte h?
Sir 10×10 size column 4 pice 16 mm,
Kitni monjil ghar hogi
Please ans?
Which column is strong rectangular or square
Inka steel details kia hoga? Numbers and size of bars?,
Sir contractor ne 9×14 ka size rka h G+3 k liye. Ye shi h sir kya. 6 steel bar use kiye h. 4-16mm ke aur 2-12mm ke
Its enough to resist load but .
@@vankranjit448 but what
Sir mere ek sawal mere ghar ke niche 35 column hai Mera Ghar 600sqft bana hai Lekin usme ek column damage hai Kya Mai 4floor tak bana sakta hu
Good
5 floor banane k liye
Kitna foundation ki gehrayi chahiye, aur column aur lintel ki size kya chahiye
Kya sabhi colom ko dena jaruri hai g+1 me jish colom me room nhi banega us kolom ko 9*9 ka nhi de sakte kya ki sabhi ko 9*12 ka hi dena hai
Sir aap is video me btaye ho aisi hi btao
Column size k sath sath foundation size and depth and beam Kya h btaiye sir
Video banao Sir
9*12 me 4 saria dal sakte hai 1 floor k liye
Nice
Sir mera 30 by 50 ka plot hain uspar ground floor 1 floor aur tower hain
Soil hard hain aur 1 feet ke baad hi pathar nikalne laage hain foundation ki depth aur volumn ka size kya hona chahiye
This is thumb rule method but actually It's depend upon loads and no's of stories with respect to there effective span from column to column
Sir g plus 2 or 4 rod 12 mm or 2 rod 10 mm chllega kya coLom size 10 by 12 hai jamin rock vali hai
G+2 per beam ki size kitna hona chaihe? Or top ka thickness kitna hona thik rahe ga?
सर 9 इंच बाय 9 इंच की colume पर ग्राउंड फ्लोर प्लस टू फ्लोर बन सकता है 500 स्क्वायर फीट है. 12mm का 4saria h... Ghar bana hua h
Mera to 9 inch by 9 inch par g+2 , sarya hai 12mm ka 4 pcs 1500sq feet hai. Bana hua hai 😂😂😂
10 by 10 column with 4 nos 16mm and 2 nos 12 mm .
Can i build 3 storey building.
Sir 5 floor ghar banana hai 60 gaz ka kya 8 piller dena sufficient hai?? 9×15 ka
Agar 9 inchi by 9 inchi bana diya h to us par 9inchi by 12 inchi ka column bana sakte h .. plz reply
Sir hamara gar 30 miter ka hai or hamne 1+1 cover kiya hai or hame half topi slap kana hai or aapne beem ka size 9by 12 hai to kya aapun topi badh sakte hai pl batana sir
Sir Mere building mai column span maximum 11 ft hai...all colum size 10 inch * 10 inch hai...steel 16 mm 4 nos & 12 mm 2 nos hai...kya mai 3 storey buildings bana sakta hun....now it's G+1.Soil is very good
Yes... You can
Hi, This video is very helpful. One question 9 inch X 12 inch with 4 16 mm steel in four corners and 4 12 mm steel in between 16 mm steel. Foundation depth in 5 feet minimum, can I construct G+3 residential building. 16 sq feet is distance between columns
Though this is touted as thumb rule but in actual it depends on structural design. 9 inch shorter size should be there with 12 15 18 inches sizes are better as any shorter size more than 9 inches will be protruding out of wall as wall thickness is normally 9 inches everywhere in India at least.
Sir ji 8oo sqfit me 9 by 15 de saktay hai❤
Coloms me meterilas kitna mix karna chahiye
I feel that they should just use a drill bit kind of shape for the columns to drill down the columns INSTEAD OF using straight pillar columns! 👍
Thumbnail topic 1:44
Bhaiya pond ke upar home construction cost kit na ayega 1000sq ft ke upar
Sir 2 mangila Ghar ki liye 12 mm steel 6 sariya use kar Sakti ho .plz reply
Yes kar sakte hai. 9"×12" ka colum size se
9,,x 12,,ka kollam ring sriya disdanc kiya hona chiyie
sir no of bars kitni deni h
Sir... gudam house 9.35m & 17.400m.ka he. Andar koi column nehi he,to column size & rad kese calculat kare ?
Please batai.
Stilt+5 and Depth of Foundation?
Humare yaha 7*7 ka column banate hai
Aur koi dikkat nhi hoti
9×10 पिलर अधिकतम दूरी कितनी होनी जरूरी है
250x250mm chalega for G+1??
Hello jo ghar me wall pe ekk shef jaisaaa hota h door level k. Uppr usko kyya bolte h..jaha saman rkhte h
slab k bare me puchh rhe ho kya ji
loft
@@khalidkhan-cz6tg hnji bro ryt
12mm ke 4 tmt bar wale (9*9) colum size me Ground floor ban chuka hai....1st floor ban sakta usi columm se hai kiya sir...?
sir depend on your plot size
Sir mere ghar k collum ki size 9'×12'and 9'×15' hai , sariye 12 mm k 10 sariye daale hai,kya g+2 ghar bana sakte hai?
Base hard rock hai
Sir 6 by 15 inch ka collums (12mm and 10mm steel ke sath) se 2 manzil ghar bana sakte hai kya..? Kaali mitti me....
No , minimum width of column should be 200 mm. So 230 mm means 9 inch lelo according to brick size
Yaar pillar ko Jamin ke andar kitna rakhna chahiye agar 3 mala bana rahe ho too
6ft
@@aamirjaasker107 TNX 🤘
Mera 90 yard(30 x 26) ka plot hai,2 diware common hai,g+1 bana raha hu,column ka distance 10 feet hai,12 colum diye gaye hai 9 x 12 ke,steel bar 12 mm(4)+10 mm(2) use kiye hai,koi paresani to nahi hogi g+1 banane se?pls reply
No..
Ring 9"hogi ya concrete Mila ke 9"
Nice question bhai
15×30 plot me kitne or kis size ke pillar hone chahiye kripya bataye
9x15 dono side me
What is about patdesign
Sir can I use 8" X 12" coloum with 4 iron bar of 16mm and 2 iron bar of 12mm Tata tiscon 550 SD for G+2 building? Distance between two coloum pillar 9 ft to 10 ft. Sir please reply🙏
12 × 12 6 rods
Layout karna sekhaye
Yes... Video available on channel
I have 9"X9" pillar size with 12 mm 6 sariya in the village, can I build 3 story(G+2)?
no
No
Never
No problem Bana sakte ho....
2 story
Sir can I use 16mm rod 4 nos 9x12 inch column
👍
1000 metre Mein Band kam kitne Baras Hota
सर मुझे 12 कॉलम का गाव मे घर बनाना है तो फाउन्डेशन मे यांनी कॉलम कितने बाय कितने के होणे चाहिये.. और कोसा बार युज करणा चाहिये...600 स्क्वर फूट... मे.. रिप्लाय करे सर..
बनाये क्या घर
appropriate size for normal residential is considered as 12" X 12". rest of the other depends upon analysis in case of increasing size further
V̲e̲r̲y̲ n̲i̲c̲e̲
G+2 ke liye hmne 9×14 ka use kiya h
We are constructing house ground plus 2 floor is column size 6inch x 18 inch is ok
CAN COLUMN SIZE BE INCREASED ON ALREADY CONSTRUCTED TWO STORY BUILDING WITH 9"X9" COLUMNS...5 EACH ON BOTH SIDES OF 5 MT X12 MT PLOT...FOR FURTHER TWO STORIES EXTENSION
G+2 Mein beem size kya hoga c1 to c2 duri 14 feet
16mm 4 aur 2mm hona chahiye
Sir column siz 9" x 12" le ki
12" x 9" le
Our house G+1with 9/9 😭😭😭
Bhai kuch problem ho rahi hai kya 9*9 column me ?
@@AdityaSingh..... no bro
My house G+2 on 9/9
My house is G+1 ..colom size is 10×10 with 6 16mm n 2 12 mm rods... can I construct G+2..?
Please guide
@@Zuventushc nohh for g+2 k liye kharcha jyada hoga ......9×12 me banao and 16mm rods
My contractor has give 25feet distance between two pillars. He has used 9x18 pillar size with 8 pieces of 16mm tmt bars. Beam size is given as 9x24 with 6 pieces of 20mm bars. It is a G+2 residential building. Is it ok ?
but the common practice for residential buildings is 12x9 pillars with maximum distance of 16ft between them.
15/15
Very strong house.
9/12me colom me 6sariya honi chahiye
Yes
Sir 1200 sq ft m ghar bnana h mujhe..3 manjil building bnane k liye pillar ka size 10"x10" de skte h with 6 rods of 12 mm.
Distance between two pillars is 10 feet.. Total 12 pillars h..
Please mera reply kre ❤💯🙏🏼🙏🏼🙏🏼🙏🏼
G+5 15"x18"
Sir g mere total nakse me 16 pillars h jinme s 8 pillar 9x9 .hai aur baki 8 pillar 9x12 kya me 3 floor ka construction kr skta hu ?
Sir I want to talk to u
Log 9×9 pe 4 storey bana lete hai kuch bhi nhi hota
jab makan girta hai tab pata chalta hai
Sir 9*12 calumn in bar
R?!
Kam ki baat karte nahi
Bekar information this information is for divert mind not complete information
3 m tak kewal bakchodi kar gya
Nice
9 by 12 kolam se 4 story ghar bana sakte he kya
9×9 inch ke column ki jgh 16×5 inch ka column bana sakte hai kya??