Column size and sariya details for 1 storey,2 storeys,3 storeys, 4 storeys & 5 storey house
Вставка
- Опубліковано 9 лют 2025
- Disclaimer - This video is for educational purposes only. Copyright Disclaimer under section 107 of the copyright act 1976, allowance is made for "fair use" for purposes such as criticism, comment, news reporting, teaching, scholarship and research. Fair use is a use permitted by copyright statutes that might otherwise be infringing. Non-profit educational or personal use tips the balance in favour of fair use.
Column size and sariya details for 1 storey,2 storeys,3 storeys, 4 storeys & 5 storey house
In this video we know about column size and sariya details for Single storey building, double Storey building, 3 storey building, 4 Storey building & 5 storey floor building and also know about what is minimum and maximum distance between two-column. Ek manjila Makan, do manjila Makan, 3 मंजिला मकान और 4 मंजिला मकान के लिए कॉलम का साइज और सरिया क्या होना चाहिए. column size for G+0, G+1,G+2,G+3 Building construction.
#RCCColumnStandardSize #ColumnReinforcement #ColumnHeight
Topic Covered:-
Columns sizes for various floors
Column size and sariya details for 1 storey,2 storeys,3 storeys, 4 storeys & 5 storey house,
building design
various column sizes
what is the column size for the g+1 building
minimum column design
g+1 building design
column design
minimum size of column
column size for ground story building
different column sizes
apartment building column sizes
building design by staad pro
column size for 1 storey building
column size for 2 storey building
column size for 3 storey building
column size for 4 storey building
column size for g+0 building construction
column size for g+1 building
column size for g+2 building
column size for g+3 building
RCC Column Standard Size
RCC column standard size
the standard size of the column
standard column size residential building
RCC column size calculation
Bar Bending Schedule Basics: Especially for Freshers Civil Engineers (Bar Bending Schedule Part-1) Kindle Edition
amzn.to/3uvEMNo
My Social Media Link:-
Telegram Link:-
t.me/yoursengi...
Facebook page:-
/ yoursengineer
Facebook group:- / yoursengineer
Twitter link:- / yoursengineer
Instagram link:- / yoursengineer
Pinterest:- / _created
Linkedin:- / vishal-goel-17426a48
Website:- myengineeringsupport.com
Accessories I Use for making Videos
Mic I use - amzn.to/3r5f1S6
The laptop I use - amzn.to/3ayYNu3
Laptop Stand I Use- amzn.to/3cnILpj
_______________________________________________________
LIKE | SHARE | SUBSCRIBE FOR MORE VIDEOS LIKE THIS
~
THANKS FOR WATCHING! -ENJOY
===============================
Apka videos bahut help karta sir ji.... Nice video making
Thanks
Thankyou so much sir, bahut videos dekha par doubt clear nahi ho raha tha , par aapne sare doubts clear kar diye .. very informative video 😊🙏👏👏🤗🙏
My pleasure 🥰
बहुत सुंदर जानकारी
Thanks🙏
Sir ghar ka hight bota dijiye
Bahut badiya hai sir
Thanks🙏
Your all video very helpful us🙏
Thanks 🙏
Too good God bless you
Thanks 🙏
Very good Sir🙏
Thanks a lot for helpful information Sir 👍
My pleasure🙏
Great video
Thanks
Informative
Good explanation 👏👍👌
Thanks
Video acha h.
Lakin bohot fast chala rahe ho.
Screin shot leynay may dikkat hoti h.
Bohot acha. Ji
Roof beam Ka same aise hi video banaye sir please...
Check on channel
Thank you Sir
गुड जॉब
U Really right Sir, Thanks
My pleasure🙏
Good evening sir
Thank you so much
Thank you sir❤
Columns ka designing structure load ke hisab se Calculate krna hota aise Andajan krna Dangerous ho skta h....islie hameha Load ke hisab se Column design krwaye Structural Engineer se jarur consult kre....
Super
Thanks🙏
Sir ham 1,2,3 Manjila makan ke liye faundesan khudai+ jali L size kitna rakhna hai,khudai kitna karwaye, abhi2 manjila de rahe hai please bataiye sir
6 * 18 size colume chalega kya ...... Niche parking aur upar makan keliye .... 6 inch bricks work karana hai.....
2 manjil me kalam aur bim size 15ft duri rakhanr par kya hoga
Sir video is very important for us, sir what to take column size, and steel for P+5?
Contact for structure drawing 9996656740
Thanks.
My pleasure😌
Nice information sir... just need one clarity .. for g+4 can we use 12"x14" colum with 4x 16 bar and 2 x 12 bar ...mistri aise hi bata raha hai..sab jagah bana hua hai
@@Pragyanand01 sahi hai itna hi har jagah lagta hai
kitna kharcha aaya total complete hone mai
Sir humhara 2 manjil hai column 10×10 hai aur usme 4 sariya 12 mm ki hai aur usme stripes 6/5.5 mm ki hai to sir es se koyi problem hoga kya?
Thanks
My pleasure✨✨✨
Roof beam and slab Ka BHI banaye AISA video
Already available on channel pls check
Thanku so much for making this owsome vid, pls tell G+5 me kya column size rhega or kon se bar use krne padenge.column distance 14×11 hai.
For 5 storey,G+4 building the size of an RCC column should be 12”x 18” (300mm x 450mm) with 4 bars of 16mm and 4 bars of 12mm Fe500 Steel with m25 grade of concrete and stirrups of T10@6″C/ ...
2 manjila ghar ke liye column ka rod size 12 inch ka and no of bar 6 ye best hein ya 16 inch ka rod and no of rod 4 , konsa best hein
Please add cost also in this series it will be very helpful
Noted
Plz make video on- Beam size .
Tomorrow will come pls wait
Bhai main 4 majila ghr bnwa rha hu kya mujhe sujhav de skte hai
Yes contact me
Thinku sir
Sir ye kaise pta chalta h ki yha itna storng column aayega ya ye kitna load bear krega?
Helo sir mene 9*9 colum pe grund flor banay he ab me G+1 banana he kiya bna sakta hu mere ghar ka aria he 28×40 total 15 colum he ples raply
Yes you can
Sir ji sabhi type ki beam ke liye koi bhi video availabe nahi he youtube par please sir aap baniye
Ok boss
@@myengineeringsupport thnx sir muje laga nahi tha apka reply itna fast aayea...😃😃 feeling awesome
@@myengineeringsupport and sir jis tarah se apne is video me column ko samjhaya he wesa hi beam wali video me samjana. and thnx in advance for beam video
My pleasure 😘
Sir G+3 keliye column size 10" by 16" provide kar sakte hain ? Or beam size 10" by 15" provide kar sakte hain ?
size of an RCC column should be 12”x 12” (300mm x 300mm) with 6 bars of 12mm Fe500 Steel with m20 grade of concrete and stirrups of T8@6″C/C.
Acha . Lekin 10" by 16" dene se kuch problem hoga kya . In future 1 manjila bhi uske upar banana hai .matlab G+4
@@PMPlansDesign 12by 12 is sufficient and you have to change the reinforcement must go from down to up with 16mm of 4 and 12mm of 2 rods thnku
Is,This,coulm size is applicable,for both type of building commercial and resedential.
No only residential
15 fit*15 fit room hone me koi dikat to nai hoga
Sir g+2 ke liya 4 tho 16 ka or 2 tho 12 ka de sakte he or size 12"*12" Plz reply sir
Yes
Sir hum g+2 house bna rai mera reinforcement 6 nos 12 mm gadha 4 foot dept or footing 8 mm spacing 4 inch or pose ka size 10×12 kya yeh save hein g + 2 storey ke liye please reply me sir
Can I use 9" X 24" columns for G + 6 building? Thanks in advance
No consult with structural engineer
😁
Can i use 9 + 15 columms for G3 Residential Room. We used 25 mm steel bar in maine colum nd 12 mm 2 nd 3 flor ??
12 ft * 17 ft room without centre beam possible?
Sir mera ghar ground flower + 2 flower he or 9×15 ke collam size rakhi he ithana sahi he kya
Sir,
My house with only ground floor was constructed in 2010 with only 10mm ×4 rod. Nw m planning to built 1st floor on tht house what should I do nw?
No mt bnana
@@myengineeringsupport sir can you guide me if i want to construct 1st floor bcoz my family is big wht should I do for the strength?
sir can you please clear k ye thumb rules frame structure klye hai ya load bearing structure qu k deehat mai mostly load bearing structures bnty hai.
Hi,... Sir... How are you... I hope... You are well.... Sir mera apse ek sawal hai ap please uska jawab dena.. Please....
Sir hamne ghar banaya tha 1 story home... Column ka size diya tha 9 into 9 or ghar ka area ha total 865 square feet hai... Sir hamre ghar me total 15 column lage hai...10 se 8 feet ke duri par . Or ab hm chahate ki uske upar or ek or story banana hai... Tho kya hm bana sakte hai ki nahi only or ek story ghar badana hai.. Matalb 2 manzil banana hai.... Foundation ka work tha 5 into 5..and depth 5..
..
Second manzil ka sariya kya rakna hai ab... Pehle manzil ka sariya 10mm or 12mmm use huwa hai...
Please reply
Ok column me steel kya use kiya
@@myengineeringsupport column me steel 6 bar use kiya tha 10mm ke 4 bar or 12mm ke 2 bar or 6mm ka square box 6inch ki duri par kiya tha.... Kya ab 2 story add kar sakte ki nahi....
*sir 6mm ka rod kab use houtha hai*
Light structure me
Sr, please btaye ki ek room 10*10 and ek bathroom 6*4 ko banane le kya cost aayegi
Sir partition wall 4" aur 6 " ho to internal column kaise ayenge.please btayiye
Means?
G+2 k liye 9×12 column thik rahega kya 4, 16mm aur 2, 12 mm bar k sath ?
Yes
@@myengineeringsupport Thank You so much Sir 🙏
My pleasure🙏
Sir main 2 manjila imarat banana chahata honnn usmain 4 room hoga kitna cost ayeega
Plot size btao brother
Sir ji ghar ka hight bhi bota dijiye
Sir 3 story keliay 12 mm ki 8 bar use kr sukta Hain aur ye kaesa rahe ga jbke column to column distance 7 feet hae aur plenth beam main konsi bar perfect rahe gi
Ok h plinth beam minimum 12mm
Sir plenth beam main kitni rod honi chahea keon ke 3 story hae
Sir m G+4 ke liye column ka size 9/15 le skta hu aur mere column to column distance 14 ft h aur ush m 12 mm ka 8 dia use kr skta hu
Yes bro
@@myengineeringsupport sir kya aap ke no mil skte h
Plz g10 ka btaiye sir
Hello sir Mera ghar G+2 hai 55 ,24 aur jis me 18 kalam 9 12 ke 6 12 ke baar hai kya Mai G+3 kar Sakta hu
Yes
@@myengineeringsupport As! Useful information
I want to discuss basement
Sirmujhe 20*25 ka hall banwana hai or Starers bhi banwane hai lekin callum side me hi chahiye beej meek bhi nahi to size or bar keya rakhe
Approx 7lakh
Thanks ji for knowledgeable vedio. But your reply in Thanks, ok, good only but you are not replying to those who are asking for suggestions.
Thanks sir ap say ye poochna tha kay 5 story building kay liey jo column size or rienforcement rahy ga footing say wo uper 5th floor tak jaty jaty same size or rienforcement rahy ga ya kam hoga ya barhy ga or beam or slab ka size or rienforcement ground floor say leky uper 5th floor tak jaty jaty kiya thickness or bars may koi diffrence ayga beam or slab kay ya nai plz reply zaroor krna sir.??
Aap upar jate huye column size or reinforcement size km kar sakte ho jitna km load utna km size kr sakte ho
@@myengineeringsupport mera matlab hay kay jo column footing say jitnay size or rienforcement ka nikal raha hy or 5 th floor tak jaey ga to is surat may column ka size or bars neechy say or uper tak kiya same dimension or bars rahein gy ya koi tabdeeli ayegi uper waly columns may ..matlab kay jo bars column may hain os say uper wala column ki bar os say zyada thick hongi ya less hongi dia may..???or sary floor same construct hongy aik jesy
It's totally depends on your budget
Sir yadi ek building me sabi column size ek Saath Lage ho to iska kya matalab hai.
Pls tell G+4building me ground and first floor ke baad dealer coloum size kar raha hai is it right
Upper ground tak 9x18 uske baad 1st floor pe 15x9
Then upar ke 2 floor 12x9 or 9x9 karra hai
Please answere
Yes no problem size km ho sakta h par bars nhi
Sir mera 27*25 fut mey g+1 ghar k liye 10"×10" colum size diya or 12 mm 6 nos tmt bar diye or colum to colum distance 3.5 meter diya kuch problem hoga keya? Plz advice 🙏
No it's ok
Sir hamari jaga 18x21 he or hamara busment he or hamare total 8 coulm he or centar me coulm nahi li lekin 1 coulm se dusre coulm tak 18 feet bhim liya he or hamare coulm me 16 mm ke 4 or centar me 12 mm ke 4 Siriya use kiya he or upar bhi yahi he or flor 3 me chhoti coulm liya he or use coulm me 16 mm ke 4 or centar me 12 mm 2 siriya use kiya he or flor 4 ke coulm me sabhi coulm me 12 mm ke 6 siriya use kiya he to muje dar lagraha flor 3 ke coulm or flor 4 ke coulm o load le sakti he ya koi problem asakta he reply
No problem
🙏🙏
Thanks brother🙏
@@myengineeringsupport 💐Welcome
My pleasure🙏
@@myengineeringsupport Sir, ground level (जैसे-rural areas) पे cement,reti की Quantity टोपली मे किस तरह ले जाती है । इस बारे मे एक video बनाईए my humble request please. 🙏
What about 6 inch thick size columns
Sir hamne 3 storey mandir ke liye 16 mm ke 8 sariye liye h thik h kya
Sir 5 manjil makan me 12 mm 4 aur 16 mm 2 to koi dikat
Yes
Kya dikat
Sir ji 9/12 colum me 4bar 16mm our do bar 12 mm ke de ke g+4 normal house bna skte hai our ek colum se dusre kolum ki duri 10 fit ya 11 feet ho ....
Sir humne 70 fit hight leni hai starting colom size kya rhega
Sir low rise buildings mid rise buildings hai rise buildings kitne floor
Hallo sir, mare Ghar ke construction me 15 foot column ki length rakhi hai our column 9*18 inch column liya hai ye sahi hai kya sir our abhi bheam pooting se 3 foot uchi pe liya hai kitna mm ke our kitne road use kare
*Bheem ka kya size houna chahiye wo bhi boliye please*
Already video available on channel pls check
Deep kitna korna he
Can we use 9 by 15 column for g+2 . Because wall size is 9 inch
Sir, ghar k base me 16 mm Char column size 9*9 ha upar ja krr column ka diameter Kam hota ha to 12 mm Char me baad me 6 mm ka churi usse G+4 utha skte h kya???
Sir we used 9*14 columns, with 4 16mm and 4 12mm rods for g+3 with all 8mm rings, is this okay ...can the building sustain..
Sir jaise jaise buildin bante jaye column ka size b kam sakte hai ??? Jaise ground floor 12"×18" fir first floor 12"×16" fir second floor 12"×14", is tarah har floor pr km bhi krte jaa skte hai???? Pls pls reply
Bilkul kr sakte ho
G+4 Mai column size kab kam karni chahiye...hamare engineer ne ground floor ko 9×21 ke column Dale pr 1 floor kon 9×18 Kiya...ye chalta hai kya..
Nhi bhai engeriner 🤔 to kabhi asa nhi karega isse column mai bo strength nhi rehegi
10x10 for G+1 is it ok?
Yes
Sir G+2 floor ke liye 9x12 colom me 12mm ke 6 rods lesakte hai?
Yes
Sir please tell me soon ...instead of 12* 12inch ...can I take 9*15
Not recommend
20*20 hall me kitne ka beam bhare
Column to column distance kya hai
May I use 4 nos 16 mm rod for 10"×10" column and beam for two storey house?
Yes you can
meterial kiya hisaab se mila na chahiye
Colum ke size ke sath colum ki duri kitni rakhani chahiye
G+3 floor ke liye 9x12 ke colom me 16mm ke 6 bar use kar sakte hai
Plot size 18 x 30 and colom to colom distance minimum 7feet and maximum 10feet
Yes you can
Can I use 4 nos 12mm Tata 550 TMT bar for G+1 ?
Yes
@@myengineeringsupport my contractor want to do brick shuttering for column upto plint beam. Is it good or bad?
Not good as plywood shuttering
@@myengineeringsupport if I do proper curing then, can I do brick shuttering sir?
Sir 30 × 50 ka plot hain 2 manjila
Column ka size kitna hona chahiye
Sir, mere ghar ka plinth level ground level se 7 ft hai. Two storied building hoga. Abhi column kiya hai (10*10) aur 6nos 12 mm bar, aur beam kiya hai (10*12) 5nos 12 mm and extra top 12mm, slab hai 5 inch. Isse koi dikkat to nehi hoga. Please reply 🙏
10 /10 ka kalam pa 16 mm ka TMT Bar dakar kitna manjil ghar bansakta ha?
4 storey
sir 5 storey building me footing konsa best h slopped ya stepped?
Depending on soil conditions
Sir Apne Puri video me Column ke Ties ko Stirrups bola hai.....
Difference is In columns we call them Ties and In Beams we call them Stirrups.
Apne jo (G+4) Five Storey Building ki details btate time 8 no of bars wali drawing show nahi kari.....
These are Thumb rules (basic rules) for understanding.....Nice video 😊
8mm and 6mm mix karke deya hain stirrup
Mera collum 9 by 24 ka h ye kya sahi size.... Aur kitna manzil jaa sakta.... Hai.... Distance 2 collum k beech... 13.5 feet h... Plz sir riply kariye
G+5
Can I use 9"*9" column size for G+1 floor and 4 no of 16mm size rod
Yes
@@myengineeringsupport Thank you and God bless you ❤