КОМЕНТАРІ • 136

  •  20 днів тому +22

    Please always use ferrules when clamping stranded wires. otherwise wou will create a fire hazard. the strands deform under pressure over time and mive and become lose, that increases the resistance in the connection and drives up the temperature, which in turn increases the resistance again. only exemption is if you use WAGO or similar connectors that are speciffically designed to work without ferrules.

  • @TurboDieselWeasel1
    @TurboDieselWeasel1 19 днів тому +18

    There are many ways to start a fire - this is one of them...

    • @SVSeeker
      @SVSeeker  19 днів тому +3

      Most of the other way are a hell of a lot easier than this.

    • @earlwright9715
      @earlwright9715 16 днів тому +2

      ​@@SVSeeker its still a way to possible catastrophe. Put the ferrals with noalox

    • @SVSeeker
      @SVSeeker  16 днів тому +2

      @@earlwright9715 ua-cam.com/video/tKo8oC0LHMU/v-deo.htmlsi=118Y9_je1sNKacyG

    • @Billtexan
      @Billtexan 6 днів тому

      @@SVSeeker Incredible

  • @AaronBockelie
    @AaronBockelie 18 днів тому +6

    Those breakers (dz47z-125) are going to burn again. They're not DC rated. They are not designed to quench a DC arc. They are designed for zero crossing free air arc quench with AC frequency. You're putting damaged AC rated breakers back into service for a DC application. At best, all you have is a disconnect, not a breaker.
    As soon as you possibly can, change them out for something more appropriate.
    Why are you using such large cabling? 4/0 single tray 3% drop should be good for nearly 200A at 60C temp. You have tiny wires going into your solar charge controllers - which means it should be high voltage in. Why are you not taking advantage of the HV PV by physically locating the charge controllers as close as possible to the battery bank? There's a lot going on here that seems unusual.

    • @SVSeeker
      @SVSeeker  18 днів тому

      Maybe you should do your research before offering advice?

  • @davidmason5163
    @davidmason5163 20 днів тому +32

    As a UK sparky....I'm covering my eyes!...just listening...just listening!

    • @stoerenungeheuer543
      @stoerenungeheuer543 20 днів тому +4

      🙈can never be unseen

    • @purplebooger6410
      @purplebooger6410 20 днів тому +6

      Wire ferrules- tinned copper wire- soldered ends- glue filled heat shrink tubing- dielectric grease??? 😂

    • @robertgarrett5009
      @robertgarrett5009 20 днів тому +2

      As a UK electrical engineer, I'm doing the same.

    • @narrowboatawyeganna447
      @narrowboatawyeganna447 19 днів тому +1

      The best way to cook ye cables is no tubes on the connections and bad connection , ask any welder 👍🏻

    • @tflemming287
      @tflemming287 19 днів тому

      MCBs are only rated to 70 Celsius. 158 Fahrenheit.

  • @Sandhoeflyerhome
    @Sandhoeflyerhome 20 днів тому +29

    You might like to redo the wire ends, just buy a packet of copper/silvered FERRULES ... Amazon they sell them. You already have the hydraulic hand crusher for the job, can save chopping off bits of wire trying to make things fit and those messy wire splays its hard to avoid. I did what you did then saw it done properly ... took me half a day to redo 14 batteries (X2 pos/neg) and all the joints in between, I am told it reduces burning/heating under load because its a full on better stable joint. I do enjoy these videos ...thanks

    • @djjudd566
      @djjudd566 20 днів тому +6

      Agreed. Tightening lugs onto bare stranded wire can result in strands loosening over time, pulling away, and creating more heat in the strands that are left connected. Starting the cycle again, until something gives and melts (or worse, catches fire). Get some Ferrules for the 4AWG wires.

  • @jonathancook4022
    @jonathancook4022 20 днів тому +8

    I used to think that once the boat was in the water the videos wouldn’t be as interesting or as frequent. How wrong was I about that!

    • @stco2426
      @stco2426 20 днів тому +1

      So true. I thinnk a boat is never really finished.

    • @SVSeeker
      @SVSeeker  20 днів тому +3

      Never really finished. That is true. But we are ready for a long shakedown run.

  • @jaba512
    @jaba512 20 днів тому +6

    If you dont like commercial wire ferrules, use your hydraulic hose press and right diameter copper pipe.

    • @SVSeeker
      @SVSeeker  20 днів тому +1

      The commercial ferrules are rather thin.

    • @ciano5475
      @ciano5475 20 днів тому +6

      @@SVSeeker They are thin because they need to deform easily to conform to the connector they are in.

    • @shaynegadsden
      @shaynegadsden 19 днів тому +2

      ​@@SVSeekerthat is intentional they aren't a lug, just a mechanism to keep all the strands tight. Using flexable cables like those under a screw terminal just spreads the strands meaning you only clamp a portion cutting down the effective area of the cable, in simple terms the same as using a much smaller cable hence why even through they were tight everything overheated

  • @13kire
    @13kire 20 днів тому +1

    I know that sometimes when a cable is too thick to fit in a terminal its common to cut off some strands but this is not really recommended in high current applications. You can get some pin connectors which will crimp to your too fat cable and provide a solid copper "pin" that will fit properly in your breaker/lug. If everything is rated properly then you should avoid any heating

  • @kschleic9053
    @kschleic9053 20 днів тому +1

    One day a few years ago my local Walmart had a bin of those white plastic cutting boards on clearance for 0.50$ each. I have a stack of 80+ left in my garage today 😂 I use them for all kinds of mounts and brackets in electrical projects!

  • @eshootziscrs2868
    @eshootziscrs2868 20 днів тому +23

    Doug,
    Someone else with real knowledge will tell you this I suspect. But that blackness inside your wires is copper oxidation being heated and carbonized.
    I experienced difficulty starting an engine years ago. Changed the starter, helped a little, change the battery, that helped a bit.
    Finally changed the wires, solved all of the issues.
    I checked the ohm resistance and found there was a staggering difference in resistance between the old and new.
    Resistance creates heat which tends to create more resistance and more heat.
    As it was explained to me, electricity flows over the wire as much as through it. Having all that oxidation and carbon on the surface prevents the flow, requiring more amperage to conduct.
    I was told boats use tinned wire to eliminate that oxidation/corrosion.
    Don't know though if it matters much.
    Everything wears out eventually, even wire I guess.
    Thanks for bringing us along.

    • @KnightsWithoutATable
      @KnightsWithoutATable 20 днів тому +9

      As a former electrician, this is correct. You need to seal out the salt water air in marine applications, especially for larger wires. You can use tinned wires or you can use soldered on connectors with silicone jacketing and water impermeable heat shrink that includes an internal glue. My classmate that was from the Coast Guard that was retraining from enlisted to a Warrant Officer by going through the same industrial electrician program I was talked about this when we discussed wiring in extreme environments to ensure reliability, like for automated irrigation that uses dissolved fertilizer or there is salt water present because of the industrial process in that plant or you're on a ship at sea.
      Another thing you really need to be using on your connectors while in such an environment, especially for high amperage applications, is dielectric grease. It keeps the moisture out of the physical connections, thus keeping them from getting corrosion that will cause resistance, which causes heat, which causes more corrosion, and into a vicious cycle. You have exactly that happening on Seeker with these connectors.

    • @kingrpriddick
      @kingrpriddick 19 днів тому

      ​@@KnightsWithoutATablealso conductive (as opposed to dielectric) greases in dissimilar metal joints that can't be sealed like a terminal block. Conductive in the joint, dielectric on the joint.

    • @KnightsWithoutATable
      @KnightsWithoutATable 19 днів тому

      @kingrpriddick yes. Doing this is what you do for this type of connection. For a tight plastic connector like a Duetz connector, you can use just the dielectric grease since the pins are protected by the connector, and you are just sealing the connector using the grease.

    • @KnightsWithoutATable
      @KnightsWithoutATable 19 днів тому

      @kingrpriddick only compatible metals are used in electrical connections. This is why aluminum triplex only goes into stainless steel connectors and aluminum wiring for housing was abandoned since there were too many people trying to join it to copper wiring. It tended to cause fires.

    • @kingrpriddick
      @kingrpriddick 19 днів тому

      @@KnightsWithoutATable compatible metals still corrode faster than identical metals, that's why there are products like oxgard and penitrox

  • @jamarie1972
    @jamarie1972 20 днів тому +4

    Doug to the rescue, building it yourself you know what you’ve used

  • @anttitiilikainen8543
    @anttitiilikainen8543 20 днів тому +6

    Hello Doug! I have watched since beginning of journey. Haven't left many comments, but today. The way of saying "build it twice, build it right" (or something on that direction). In Finland we are bit more modest, "kolmas kerta toden sanoo" which is literally translated "the third time tells the truth". But more accurate translation maybe would be "third time is the charm". Any finns yet participated on building? Haven't my self noted yet...

  • @keithc904
    @keithc904 20 днів тому +3

    Nice work Captan, there is sense of freedom to get your power from the sun, no one can shut off.

    • @brianpennington4202
      @brianpennington4202 19 днів тому

      Why is it the freedom loving conservatives seem to hate solar power then?

  • @MyLilMule
    @MyLilMule 20 днів тому

    When you were lowering the dingy and the winch or whatever it was started "squealing", I had to pause the video because I though one of my Huskies was howling in the next room. 😂

  • @Graveltrucking
    @Graveltrucking 20 днів тому +1

    The power of DC electricity, the cable you showed, was well cooked. It's good to see you can produce enough juice where you don't have to run the auxiliary unless it's necessary.

  • @KnightsWithoutATable
    @KnightsWithoutATable 20 днів тому +11

    Added post watching video: That breaker is toasted Doug. Replace it. That much heat where the plastic has turned black is going to damage the internals. When in doubt on over current protection devices (breakers and fuses), always replace. I am sure that it was in the list you had in your parts to order. Should be fine to run it in the mean time, but long term its lifespan has definitely been shortened from decades to less than a year of reliability. The cutting board in the electrical box wasn't the best solution long term. The plastic of a cutting board has no fire retardants in it and the melting temperature is a bit low for it, so if things get spicy again in there, instead of a melted mounting panel, you could get a fire and burn up your wiring and breakers, causing dead shorts (fire's flames are conductive, by the way), leading to equipment damage.
    OK Doug, here is what I would have done as a professional electrician and yes, this is for marine applications and on a budget, but it is for reliability as the focus for critical systems and to protect expensive equipment. It is more that you might think is needed, but this is what it will take to prevent this problem from happening again in the future. This is all before watching the video.
    Step 1: re-do all of the wattage and amperage calculations in case you got them wrong. Include that the system is running at 110+ F in that box in your calculations and de-rate your wiring as is appropriate. You have had some hot days on the boat and the box doesn't have active cooling for it. Ambient where you are has had 100+ F for several days I am sure with it being Florida, so you need to factor that into your design. A good design rule of thumb for what you are trying to design here would be the ambient temperature that it is going to run at in the tropics at the highest (110+ F) and then another 10 to 15 degrees for aging of the wire over time and a fudge factor for thing aging over time and getting extra hot on a few days or weeks over the life of the system. You can look up how to de-rate wire amperage carrying capacity online. You probably don't have to go thinker, but you might need to choose a different jacket of higher quality for inside the box where things get toasty.
    Step 2: I would replace the short wires in that box and cut back 2 to 12 inches of wire going into the box to get fresh copper and insulation that hasn't been fried by the heat and oxidized the copper strands. I would tin the tips of the wire with solder completely (might need a torch for this if you don't have a soldering gun and use a wet rag to protect the jacket from the heat) and, if possible, get some ferrules soldered onto the ends of the wires. The ferrules need to be made out of either silver or marine grade stainless steel. Any other metal is going to cause the same problem you have here and that especially includes those brass connectors I have seen in your solar/batter/generator system. Replace the oversized connectors like you planned. Use dielectric grease (just a little dab will do ya) to keep moisture out of the connections to keep them from getting oxidation in them.
    Dielectric grease should be used on all electrical connections on Seeker, especially ones that run high current. It is expensive to buy a tube of it, but it takes very little of it to do a connection. Just a thin coating on the surface of the male end before installing is all. One standard tube could probably do all of Seeker's wiring and still have leftovers for maintenance. You should also look at tinning the ends of all large gauge wires on Seeker, along with putting the heat shrink with adhesive on it to seal out moisture from the inside of the wires before you end up having to rewire every single one of those very expensive, thick wires. The corrosion will creep up them from the ends and ruin them. You don't have to put connectors on them if they are occasional use cables since the tinning will be good enough, but connectors soldered on with heat shrink with internal adhesive is the standard practice for marine applications since it keeps out the moisture and even water, so it would let you have flooding in the engine room not lead to needing to re-wiring the engine room when you got back to port.
    If I was still living near where you are anchored, I would come aboard and help with the work, but I am on the other side of the country now, so the trip is a bit beyond my means right now.

    • @road8248
      @road8248 20 днів тому +3

      Very through advice and possibly the longest comment i have ever read on UA-cam. 9/10

  • @michaelardai9703
    @michaelardai9703 20 днів тому +2

    Many breakers are not rated for fine-stranded wire without ferrules...

  • @richardchalmers7324
    @richardchalmers7324 20 днів тому +3

    Doug,
    Its time to improve the terminations.
    Lugs & Bootlaces are not just for good looks.
    Loose terminations = Heat and Corrosion.....
    I would redesign to include room for larger junction boxes with room for airflow or a heatsinked back panel. The closer you can install your batteries to the controllers the better to reduce cable sizing where possible - Low voltage and resistance are your enemy when dealing with DC.
    I know you know this and I know you know better but I don’t think you respect it enough to do better.

  • @Totelrecall
    @Totelrecall 20 днів тому +9

    Could also try ferrules?

    • @wheel2keel
      @wheel2keel 20 днів тому

      Don't know for 0000

    • @ki6hzs
      @ki6hzs 20 днів тому

      Good catch, boy that copper cable cost a bundle.
      Looks like you should be good to go now. 👍🏼

    • @jrt2924
      @jrt2924 20 днів тому +1

      ​@@wheel2keel There is. Sure aint most common size but i Bet that would help a bunch.

    • @wheel2keel
      @wheel2keel 20 днів тому

      ​@@jrt2924typically I use ferrules for control circuits but not 00 or 0000

  • @JimbleKimble769
    @JimbleKimble769 20 днів тому +3

    Doug. Please. For the Love of God!!!!!! USE use some G.D. Glue filled wire ferrules with the tinned copper heat shrink tubing, and soft edge dielectric flux pellet's, in the cereal outlet next to the raisin bran marshmallow wheelbarrow. Ya Ding Dong.

    • @paulmiller6277
      @paulmiller6277 15 днів тому

      Yes the black wire is copper oxide it's not a conductor and formed buy copper reacting with oxygen in the atmosphere the heat has probably seeded up the oxidation. Were the black copper cable the negatives ? Negative copper wires seem to oxidise quicker.
      Tinned cable and hermetically sealed connectors will work alot better.

  • @TexasVeteranPatriot
    @TexasVeteranPatriot 18 днів тому +1

    With that fine strand hi-flex wire you really need ferrules on the ends.

  • @vainwretch
    @vainwretch 20 днів тому +3

    If you notice the screws that clamp down the wire are only making a small amount of contact with the wire.
    If you put lug's on the end of the wires and soldered them into the lug's it would make a better connection.
    Kind of like the lugs for automobile battery cables.
    The arcing that is causing the burnt spot on the end of the wire is also causing less contact and starving the amount of current getting through the wire to that screw down connection causing the heating problems.
    I don't think you necessarily have to replace the block with a smaller one.
    I know you will figure it out.

    • @earlwright9715
      @earlwright9715 16 днів тому

      And causes expansion and contraction with the load , causeing heating and burning

  • @DHMFSSIHTA
    @DHMFSSIHTA 20 днів тому +1

    Doug, if tinned wire isn't feasible, glue lined heat shrink can get a good moisture/salt tight seal between the insulation and the lug. A few more ABC fire extinguishers wouldn't hurt. Some lawyer named Murphy might sneak aboard and set the cabin on fire when you're rounding the horn.

  • @wheel2keel
    @wheel2keel 20 днів тому +3

    You make absolutely get content.... Thanks

  • @Hawk_eye
    @Hawk_eye 20 днів тому +2

    Thanks Doug 👍

  • @sayaka23
    @sayaka23 18 днів тому +1

    If there was a fire in the engine room and it was blocking the compaino way as it was hydrolic oil and gas cylinders and diesel on fire could people escape the cabins?

    • @SVSeeker
      @SVSeeker  17 днів тому

      Go out the escape hatch into the pilothouse or one of the two portholes into the water. But I will want to know why you were so stupid as to ignore the fire alarm.

  • @kapytanhook
    @kapytanhook 20 днів тому +1

    Very cool you manage to get these projects done on the water like that. Seems so difficult to get supplies. Enjoy it out there

    • @SVSeeker
      @SVSeeker  20 днів тому

      It's not that bad. But I have my truck at the marina and I have learned most of the supply houses in Pensacola.

  • @johnmallette3143
    @johnmallette3143 20 днів тому

    Tkzz for sharing.,.,.,peace

  • @tomwilson3013
    @tomwilson3013 20 днів тому +1

    Have you set up a solar dump load so you aren't wasting solar production? Victron stuff makes is fairly easy to set up.

  • @Sailingengineer74
    @Sailingengineer74 20 днів тому

    Cutting boards are fantastic for creating things ! Cheap from Swedish Ikea, you get 1,5mm cutting bord, I use em as separating material sheet between dissimilar metals onboard

  • @Snarggle
    @Snarggle 18 днів тому +1

    Dc doesn't mess around...

  • @joopterwijn
    @joopterwijn 20 днів тому

    Good job captain

  • @collinwerth9886
    @collinwerth9886 20 днів тому

    Yay uploads

  • @Deutschehordenelite
    @Deutschehordenelite 20 днів тому +3

    Would crimping the ends prevent this from happening?

    • @SVSeeker
      @SVSeeker  20 днів тому +1

      Certainly would not hurt but letting it get hot once in loose lugs sort of starts the ball rolling and it was old cable to begin with.

  • @mikkei3532
    @mikkei3532 20 днів тому +22

    your problem with burn brakers is connetcion - put a little metal tube on this tiny copper cables and this solve problem !!!!!!!!

    • @buellb0y
      @buellb0y 20 днів тому +5

      * breakers
      *connection
      *lube

    • @buellb0y
      @buellb0y 20 днів тому +2

      FFS my man…

    • @purplebooger6410
      @purplebooger6410 20 днів тому +5

      They are called wire Ferrules! Tinned copper or silver Ferrules and tinned copper wires combined with solder and glue infused heat shrink! Best stuff for long term use at sea! I slide my ferrules on and tighten the bolt so that it leaves a crimp in the ferrule deep enough to get all of the threads of the junction connector then solder the ferrule on and cap the end with glue filled heat shrink sealing the wire and ferrule together. Finish it off with a dollop of dielectric grease and it’s done for many years!

    • @robertgarrett5009
      @robertgarrett5009 20 днів тому

      Or just wrap the tri rated cable ends with copper wire if your not lugging it.

  • @blueelectricfusion
    @blueelectricfusion 20 днів тому

    surprised your running 4/0... I wired my truck with superflex 00... awesome stuf... pricey... but worth the exapense.... don't forget to check your resistance across the circut. it does reduce losses but also heat. 😅

  • @evil_me
    @evil_me 19 днів тому +1

    Id recommend trying noalox and using ferrules.

  • @cloudsculptor1
    @cloudsculptor1 20 днів тому +7

    There's me thinking it was about the northern lights !

    • @jamarie1972
      @jamarie1972 20 днів тому

      We in the Uk was treated to a great Aurora Friday.

  • @Buck1954
    @Buck1954 19 днів тому +1

    I didn't realize that a wire could get fried if the receptacle for it was too large. Good thing to know.

    • @SVSeeker
      @SVSeeker  19 днів тому

      Just started with a bad connection and slowly spread from there.

  • @ssaw88
    @ssaw88 20 днів тому +4

    Make sure your using the combiner box to get the highest voltage your system can handle from the panels. This will lower the amps and significantly reduce the heat. I have 8kw of solar panels and 40kwh of battery at 54.6vdc

  • @earlwright9715
    @earlwright9715 16 днів тому

    Ferrals and maybe noalox

  • @Chris-ut6eq
    @Chris-ut6eq 20 днів тому

    Ever thought of putting some temp monitoring (thermocouple) on power connections? I'm considering it for a future solar project so I get overtemp warnings before things get super hot. That black stuff on the copper looked like it might have been from the insulation being cooked.

    • @SVSeeker
      @SVSeeker  20 днів тому +1

      No. I simply touch stuff to see how it's doing. : )

  • @StaticSift
    @StaticSift 20 днів тому

    Thats so awesome your living this journey.. Youre living the dream. Here I am sitting in the NOC at onegas monitoring servers..

    • @SVSeeker
      @SVSeeker  20 днів тому +1

      Cool. Do you know I was a DBA on the 15th floor at ONEOK?

    • @StaticSift
      @StaticSift 20 днів тому

      @@SVSeeker yea thats what actually brought me to your youtube, seen a news article. Thats so cool. Onegas is the former child company of oneok, im sure some of your former colleagues are with us now and vice versa.. I love this company, and from what i hear oneok is the same.

    • @StaticSift
      @StaticSift 20 днів тому

      @@SVSeeker i work hand in hand with our dba's here in the noc.. currently learning redhat

  • @captaintoyota3171
    @captaintoyota3171 20 днів тому +1

    Really too it your motto to heart Steve. Ive been a procrastinator on my projects for a decade. But last 3months ive rebuilt an entire 1997 subaru. Feels good to make progress. What'd you work on today?

  • @DeKempster
    @DeKempster 20 днів тому +20

    Fucking use wire ferrules

    • @sbrunner69
      @sbrunner69 20 днів тому

      Fucking be nice dick face.

    • @briansaben5697
      @briansaben5697 20 днів тому +1

      Why are you fucking swearing? 😂

  • @bigangelman
    @bigangelman 20 днів тому

    You need to put your panels in a series and get up to 48vdc, the wire sizes can handle the load better

  • @TheREALJosephTurner
    @TheREALJosephTurner 20 днів тому +2

    "It used to be a cutting board." As an amateur radio operator who builds his own antennas, I've uttered that exact phrase many, many times!

  • @KamikazeWombat
    @KamikazeWombat 20 днів тому

    Lol what were the dolphins doing? Splash competition?

  • @Vitoandolini13
    @Vitoandolini13 16 днів тому +1

    Patients is a virtue possess it if you can often found in women seldom found in man

  • @nickwulf
    @nickwulf 20 днів тому

    “You cannot possibly please everybody, you are not a pizza”

  • @eddiereichel9354
    @eddiereichel9354 19 днів тому

    I was under impression "oxi guard" or similar stuff is less about conductivity is it is preventing corrosion which hinders conductivity.

    • @SVSeeker
      @SVSeeker  19 днів тому

      Well, the stuff I have says it improves conductivity.

  • @DenHvideHund
    @DenHvideHund 20 днів тому

    how many amps are running through those wires ?

  • @democracymmmk
    @democracymmmk 17 днів тому +1

    When are your going to start cruise for science?

    • @SVSeeker
      @SVSeeker  17 днів тому

      Next is a long shakedown and then we will be ready. Got to wait on the Captains License to come through too.

  • @banditfet
    @banditfet 20 днів тому +2

    for the connections going into the terminals where you have the multi stranded wires, id recommend using pin crimps/bootlace crimps it will give you a lot better connection

  • @ssaw88
    @ssaw88 20 днів тому +1

    Also use anti corrosion paste

  • @theonly9
    @theonly9 19 днів тому

    @7:47 I thought my cat was screaming lol.

    • @SVSeeker
      @SVSeeker  19 днів тому +1

      Some days it sounds like wolfs howling. : )

  • @carlhaynie8710
    @carlhaynie8710 20 днів тому +2

    When it comes to high current connections, it’s always important to have wide and firm “gas tight” contact to the cable to keep the connection reliable and keep out water and other contaminants. Your good wire appears to have had a good clamp force, but only a very small area of contact which means that the wire would eventually burn as well. I suggest a crimp on connector on the wire end and then a bolt down terminal block. I also suggest soldering after crimping. I’m not fond of the European style terminal blocks that crimp raw wire under a screw, especially with stranded wire. You can crimp on and solder ferrules that alleviate somewhat the problem bare wires but don’t put solder under the clamping screw.

  • @achristianson4059
    @achristianson4059 20 днів тому +1

    Wow… how close was this to turning into fire?

  • @burlatsdemontaigne6147
    @burlatsdemontaigne6147 20 днів тому

    Doug; telling forklift batteries how to behave.

  • @tflemming287
    @tflemming287 19 днів тому

    Sir, you require ferrules.

  • @wrighr01
    @wrighr01 18 днів тому +3

    Seems you have an unlimited supply of everything… who cares what breaks? , you just keep fixing it. What ever happened to the original purpose of this junk boat? , we yet to see anything. Keep up the great work selling the garb(age).

    • @SVSeeker
      @SVSeeker  18 днів тому

      You will never achieve your goals without patience.

  • @smca7271
    @smca7271 5 днів тому +1

    Surprised you don't listen to comments from people with more experience , I thought you were all about learning .

    • @SVSeeker
      @SVSeeker  5 днів тому

      I've been surprised how many people think they are God's Gift to mankind who actually are just full of shit. That's not you is it?

    • @smca7271
      @smca7271 5 днів тому +2

      @SVSeeker you sound hostile?. Are you still having fun.

    • @SVSeeker
      @SVSeeker  4 дні тому

      @@smca7271 You sound like a dick. I'm don't have fun with dicks. : )

    • @smca7271
      @smca7271 4 дні тому +1

      @@SVSeeker pleasant sailing

  • @quadcam24v
    @quadcam24v 20 днів тому +2

    Too many hot pockets.

  • @IndependantMind168
    @IndependantMind168 18 днів тому

    Just keep an eye out for that copper coated aluminum crap. It's junk.

  • @jonathancook4022
    @jonathancook4022 20 днів тому +2

    Also, I think Doug is one of the kindest and most down to earth guys on UA-cam

  • @4GH440
    @4GH440 19 днів тому +7

    As a sparky my best recommendation is - spend the money and hire a marine electrician. If you are insured I just hope your insurance company never sees this video.

    • @SVSeeker
      @SVSeeker  19 днів тому +1

      Absolutely not. Worst advice ever. People need to learn to do this shit themselves. There are plenty of idiots that don’t know shit and will call you.

    • @SVSeeker
      @SVSeeker  19 днів тому +1

      And insurance is for people with too much money and two little skill.

    • @gregharding7329
      @gregharding7329 19 днів тому +6

      @@SVSeeker well lad you just keep doing what your doing and when your boat burns down around you for simple fact you screwed up you will never be able to say you were not warned.

    • @SVSeeker
      @SVSeeker  19 днів тому +2

      @@gregharding7329 Oh for fuck sake. Pussies like you have been predicting doom for decades now. Grow a pair. ua-cam.com/video/X29lF43mUlo/v-deo.htmlsi=CKqepJWRca2OSZKw

    • @gregharding7329
      @gregharding7329 19 днів тому +6

      @@SVSeeker That the best you got sunshine. Someone gives you real world advise that actually knows what they are talking about and you talk insults. As soon as you commented and I quote "And insurance is for people with too much money and two little skill." it told me all I want to know about you.

  • @countryboydesign6541
    @countryboydesign6541 20 днів тому

    Might want to look into aluminum wire for that to handle the heat and power

    • @jackdbur
      @jackdbur 20 днів тому +2

      Nooo .especially NOT in a marine application 😮

    • @jsvalina3503
      @jsvalina3503 19 днів тому +1

      Noooooooo, would be way worse.

  • @brianmahoney4156
    @brianmahoney4156 20 днів тому +1

    did anyone ever tell you that you look exactly like craig venter