Manitowoc Ice Machine Harvest Issue

Поділитися
Вставка
  • Опубліковано 28 січ 2025

КОМЕНТАРІ • 58

  • @吹不要
    @吹不要 Рік тому +1

    Thank you, repairing an ice machine has been bothering me for the past few days, after I saw you adjust the water valve, I did the same with you, all the pressure is very good. Harvest is also normal.

  • @mrnapolean1
    @mrnapolean1 2 роки тому +2

    Its really cool to see how the refrigerant process works on a Ice machine.

  • @bradmironik6137
    @bradmironik6137 Рік тому

    Good content. I got a crash course on water cooled ice machines. Learned a lot about how they work and ended up with a cleaning and replacing the water valve because it leaked. This was also a harvest issue.

  • @hvactechpr7872
    @hvactechpr7872 2 роки тому +1

    We don't see water cooled stuff alot here thanks for the pointers!!

  • @youngdust6730
    @youngdust6730 2 роки тому

    Thank you bro this was extremely helpful, I was about to pull the whole reefer charge and refill it. Now I know what the pressures need to look like

  • @terranceburgess9170
    @terranceburgess9170 Рік тому +1

    Having the same issues with a manitowoc u140a under counter harvesting is taking long and the safety 2 is flashing on the board I cleaned the ice machine it did make ice but harvest time was still long

  • @miguelrojas3394
    @miguelrojas3394 Рік тому

    Thank you so much Anthony, I learn every day new way to troubleshooting thank you 🙏👏.

  • @KALZONE850
    @KALZONE850 Рік тому

    great content man. just discovered your channel. i need to get one of those magnetic testers! thanks for your time.

  • @pralaypatel7110
    @pralaypatel7110 2 роки тому

    Professional diagnosis and explanation!

  • @thesilentonevictor
    @thesilentonevictor 2 роки тому

    Great method on solving this one

  • @obedb093
    @obedb093 8 місяців тому

    are these the pressurea for all manitowoc ice machines

  • @garygordon37
    @garygordon37 4 місяці тому

    @garygordon37
    good day i has a indigo NXT manitowoc ice machine it drop ice then going into long harvest then after turning in off and on it makes ice then drop then start the second cycle after freezing then it goes into long cycle. i replace the ice thickness probe then, the board and the problem still exist i also check the curtain switch and its ok, . As i say after turning it off the on after the first ice drop, the second time around after the freeze cycle it goes into long harvest

  • @patricvandermerwe8567
    @patricvandermerwe8567 2 місяці тому

    Please help me, my Manitowoc QR450A keep on overflowing my water tray ? From Namibia Africa

  • @DakotaHeatingAndAir
    @DakotaHeatingAndAir Рік тому

    I got a compressor I believe burnt out, checked pressures and they are equal, no movement. Compressor sounds gnarly and it starts to get really hot. Hi pressure line isn't getting hot whatsoever. I'm trying to find out the cause as to why the compressor has failed, there was a company here a couple years ago from the notes that replaced the compressor once already I dont know if I should replace the txv as well.. I don't wanna get a new one in and the same problem pops up down the road. I'm going to flush all the lines with rx11 and put another drier in line to pick up any extra acids in the system. Any pointers?

  • @vaart9614
    @vaart9614 2 місяці тому

    What is the model for this ice machine?

  • @mexecomigoBrasil25
    @mexecomigoBrasil25 Рік тому

    Hello. Thanks for teaching us . with your skills! My question is how do I download the temperature hot , and cold line , chat that I see in your phone?

  • @kenfes1912
    @kenfes1912 2 роки тому +1

    Do you think there's a chance you may have just been slightly low on refrigerant? Because you were low on both sides.... And when you adjusted the valve your pressures did change... I'm just wondering if you didn't have enough refrigerant. It ran a long time before on that old valve and it was set at that pressure before for all those years... But I have seen those valves go bad especially when the units off and water still running down the drain

    • @REFRIGERATIONKITCHENEQTECH
      @REFRIGERATIONKITCHENEQTECH  2 роки тому +1

      At first I was thinking low charge but my suction pressure was really good and my sheet of ice was even right across so I didn’t go that route. When I got there, the unit was off and there was water going down the drain so that also pointed me in the direction of a bad regulating valve

  • @_thepK
    @_thepK 7 місяців тому

    what if my freezing time is too long? harvest time is ok, but freeze time getting around 40-50min instead of 20-25mins, after 25min im gonna manually switch to harvest and its going well, but if i dont manually switch to harvest it gonna be overfreezed. can you help me?

  • @pavelspilberg9310
    @pavelspilberg9310 2 роки тому

    Good job at usually 👍

  • @Colt-wr6wx
    @Colt-wr6wx 2 роки тому

    Well done.. those water valves are a pain sometimes

  • @khayberadil
    @khayberadil Рік тому

    awesome

  • @Supanova70
    @Supanova70 10 місяців тому

    So mine is not making ice. water and parts clean new pump/ice sensor/water valve/water probe was replaced. Evap never getting cold enough to make ice.

  • @youngdust6730
    @youngdust6730 2 роки тому

    By chance do you have a good place that I can find manuals before call manitowoc?

    • @REFRIGERATIONKITCHENEQTECH
      @REFRIGERATIONKITCHENEQTECH  2 роки тому +1

      Partstown will have some and on Manitowoc’s site they will have all the service manuals.

  • @juanrios7632
    @juanrios7632 Рік тому

    Great info! One question, what would you have done if this was an air cooled machine? Would you have added refrigerant to increase those pressures? Keep the videos coming wr all benefit from them. Thanks again.

    • @REFRIGERATIONKITCHENEQTECH
      @REFRIGERATIONKITCHENEQTECH  Рік тому

      If I had low head the issue could be a low charge, a restriction (potentially the TXV) or an inefficient compressor. Would need to see the suction pressure to make a more accurate assessment

    • @hh-oq8gc
      @hh-oq8gc Рік тому

      Got one 100 psi suction , 200 high side , had bad water level probe machine had been running without water compressor cool to touch and liquid line not hot ? Compressor??

  • @Rolitorres
    @Rolitorres 2 роки тому

    Where Is the valv what did adjust?

  • @cdanskipp
    @cdanskipp 2 роки тому

    All i did was Cleaned a machine like this and now it's not producing ice. You got any suggestions on why it would not work afterwards

    • @cdanskipp
      @cdanskipp 2 роки тому

      It's a about a 2005 model

    • @REFRIGERATIONKITCHENEQTECH
      @REFRIGERATIONKITCHENEQTECH  2 роки тому +1

      Is the curtain on correctly, water probes hooked up, water in the trough etc. Too many things could go wrong, the led’s on the board should point you in The right direction

  • @deanmohamed7575
    @deanmohamed7575 2 роки тому

    Thank you for this water cooled ice machine troubleshooter. Quick question: I changed one of these valves several years ago and i think if you are changing the water valve, you do NOT have to recover the refrigerant right? I totally forgot.

    • @REFRIGERATIONKITCHENEQTECH
      @REFRIGERATIONKITCHENEQTECH  2 роки тому

      Yes, it is connected to the Condensor and based on the pressure in th Condensor, it tells the PRV how much to open/close.

    • @deanmohamed7575
      @deanmohamed7575 2 роки тому

      @@REFRIGERATIONKITCHENEQTECH thanks :)

  • @earlsimmons7742
    @earlsimmons7742 Рік тому

    What if it's not?

  • @FJB-bl8xg
    @FJB-bl8xg 2 роки тому

    Great Thumbnail.

  • @shine-cg9uf
    @shine-cg9uf 2 роки тому

    🇺🇸❄👍💪 great troubleshooting skills very helpful. NHL playoffs next week

  • @harrydickson4575
    @harrydickson4575 2 роки тому

    👍👍👍