HVAC Service Call: Commercial Steam Boiler Fails Inspection (Manhole Cover/Gasket Installation)

Поділитися
Вставка
  • Опубліковано 10 вер 2024

КОМЕНТАРІ • 69

  • @alexibonnet2634
    @alexibonnet2634 2 роки тому +11

    Wow!! bringing back memories. Fire tube boilers I use to operate & maintain when I lived in NY. For that manhole/gasket to be in that condition
    Building Engineer not doing their job. That’s routine maintenance task. Nice job/repair like always.

    • @bunnyman6321
      @bunnyman6321 Рік тому

      Do working around boiler equipment damage hearing?

    • @JC-123
      @JC-123 Рік тому

      ​@@bunnyman6321yes

  • @samuelaranda4597
    @samuelaranda4597 2 роки тому +5

    Wow good job. I use to work on Clayton steam generation boilers. They had a operating pressure of 450 pounds. I retired from HVAC 31 years Union. I don’t miss working on steam. Be careful

  • @danwiens9830
    @danwiens9830 7 місяців тому +1

    I find it easier when you put the manhole cover back on to wire it up to a piece of pipe that is in line with the yolks and over the opening. This way you don’t run the risk of dropping it in the boiler and you can line up the gasket easily

  • @christopherleubner6633
    @christopherleubner6633 5 місяців тому +1

    Yikes. Rotted cleanout on a big boiler. That is very scary. 😮😮😮

  • @slipstreamvids7422
    @slipstreamvids7422 4 місяці тому

    We had a 150hp fire tube boiler (230 psi) that fed presses and a low pressure heating loop. The main output nozzle sprung a leak midday and roared like a jet engine for hours even with the blowdown wide open. The entire room was engulfed in steam and you couldn’t see your hand in front offyour face. The boss tied a rope around his waist and shinnyed along the floor to reach the main disconnect and threw it. We called a welder in and he spent 4 days laying bead around the nozzle and a generator truck and annealing blankets ran all night to keep the weld soft.

  • @izzybell11
    @izzybell11 2 роки тому +4

    Interesting and helpful video. Well explained. Great job 👏 JMT. And special thanks for the clip from Seinfeld 😀😎. My favorite show

  • @Oppenheimer1968
    @Oppenheimer1968 2 роки тому +12

    Please be very careful- should have been a physical LOTO (lock and hasp) in place instead of an on/off switch on gas burner.

  • @jessphilps4298
    @jessphilps4298 2 роки тому +5

    Dam that boiler room looks like a Dump - My boss would go off on me if I ever let my boiler room get like that

  • @MarioDallaRiva
    @MarioDallaRiva 2 роки тому +1

    Ahh, when that nut released?? Ahh, great sound. 👏🏼👍🏼💪🏼

  • @soloch69
    @soloch69 Рік тому +1

    I miss working on Boilers, great video keep them coming 👍🏻

  • @robertdavenport9095
    @robertdavenport9095 2 роки тому +1

    Your videos are King bro you do a very great job on all your jobs.

  • @BasketballAve
    @BasketballAve Рік тому +1

    When you can get yourself a Milwaukee impact 20v with impact rated socket ends and you’ll bust those out in 2 seconds great vid.... my truck got broken into 3 different times... all in Miami. The slick locks are a pain but since using them I haven’t been broken into...
    A curse on those who steal tools from the working man... they’re scum

    • @jrtakesthesky27
      @jrtakesthesky27 Рік тому

      Literally stealing a mans lively hood. Indeed scum.

    • @Mike-rm7vf
      @Mike-rm7vf Рік тому

      Milwaukee makes 20v tools?

  • @lnk4328
    @lnk4328 2 роки тому +2

    If you would have locked the second boiler's Honeywell RM78XX control on "Prepurge" for the night, the boiler would have been nice and cool on your return. All of the limits and safeties (ie, low water, etc.) need to stay made for this to work.

    • @Mike-rm7vf
      @Mike-rm7vf Рік тому

      You can split a tube in the hot pass weld and stretch the rear sheet by doing that.

  • @davemurphy7099
    @davemurphy7099 6 місяців тому +1

    I am surprised that boiler where opening for the inspection where all the manholes cover, and low water alarm not taken apart. and most manhole cover are 11 X 15

  • @nicolerennie
    @nicolerennie 2 роки тому +1

    intense! great content. I enjoyed the show clips too, surprise bonus🌟🌟🌟

  • @parmodbist414
    @parmodbist414 Рік тому

    Sir
    If you bolt & nut difficult to loose and open just warm with torch so very easy to open & time save

  • @peeonthe3rdrail414
    @peeonthe3rdrail414 Рік тому +4

    Bro why the hell are you using a pipe wrench on a hex nut? Hack.

    • @Sparky95
      @Sparky95 Рік тому +2

      They said earlier in the video that a bunch of tools got stolen from their truck, including their socket set. Even so, since they ran to the supply house, surely they could have picked up another socket set...

  • @michaelaaron1134
    @michaelaaron1134 Рік тому +1

    Man. Grab some baking paper and put a ring underneath the gasket and above the gasket. It'll seal just fine and you'll never seize on there again. If nothing else use some antiseize for the next guy, who could be you

  • @eugeneharrelson3933
    @eugeneharrelson3933 2 роки тому

    Was a control tech for boilers, use to change those gaskets all the time. Looks like a Superior boiler

  • @JohnDoe-ej1lw
    @JohnDoe-ej1lw Рік тому

    Damm as a licensed engineer I say that boiler room is nasty....great video, ive done some jobs like that in my work boiler room..

  • @johnwalker890
    @johnwalker890 Рік тому

    Good job Jumper, Looks like a large pressure cooker.

  • @robertpeters9438
    @robertpeters9438 2 роки тому +2

    No anti sieze?

  • @vernessalkic1065
    @vernessalkic1065 2 роки тому

    Loved the Seinfield reference

  • @Uppallayyaasunny
    @Uppallayyaasunny 6 місяців тому

    Super
    Nice

  • @kencolon1870
    @kencolon1870 2 роки тому +1

    This may seem like a simple fix and it is but mind u he has a man helping him picture doin this by yourself. I work in Connor I’ll boilers now local 638 nyc and for those boilers to b in this condition they are not being properly overhauled yearly like they should

    • @Mike-rm7vf
      @Mike-rm7vf Рік тому +1

      That has to be a low pressure boiler for it to have 67 float on it. They don’t open that up every year at all.

  • @stephwaylonwells3218
    @stephwaylonwells3218 2 роки тому +1

    👍

  • @meatwad600
    @meatwad600 Рік тому +1

    Crazy how careless people can get when working with pressure vessels. That's year's of neglect. 15 lbs of pressure may seem like a small amount but on a vessel that size plus all the piping it adds up. If that man way would haved failed exposing the water to atmospheric pressure the result would be catastrophic. Boiling liquid expanding vapor explosion.

  • @greekmaster1001
    @greekmaster1001 6 місяців тому

    If that supply house was in NYC it's either H&L or AF

  • @boilertech44
    @boilertech44 6 місяців тому

    Large boilers lol. When you open a drain, always open a vent.

  • @lumconline3215
    @lumconline3215 10 місяців тому

    So many things done wrong in this video, including man way cover gaskets are not some obscure size.

  • @ayoutubewatcher7009
    @ayoutubewatcher7009 2 роки тому

    nice work, be safe.

  • @anthonyd3661
    @anthonyd3661 2 роки тому

    Liked the boiler content

  • @samihabib661
    @samihabib661 9 місяців тому

    Which supply store did you find the manhole cover at ?

  • @truckvlog-387
    @truckvlog-387 2 місяці тому

    need to replace the boilers not a inspection hatch

  • @renj6531
    @renj6531 Рік тому +1

    15 pounds so that thing operates at roughly the same pressure as an average car radiator is what your telling me

  • @mangekyusharingan88
    @mangekyusharingan88 2 роки тому

    👌

  • @markae0
    @markae0 Рік тому

    How tight? Yes.

  • @williedelgado1082
    @williedelgado1082 2 роки тому

    Have to isolate that boilers king valve. Just a thought

    • @malachy1847
      @malachy1847 Рік тому

      Proper Mechanical and Electrical Lock Out would have / should have needed to be carried out... Work Permits Issues and signed onto, Pipe Spades Fitted , Electrical Panels opened Up Fuses Pulled and Isolation Lock signed out and Fitted...Utilities Operator instructed to drain down the Boiler and Vent the Boiler, remember a Leading Hand Millwright friend of mine just got stuck into the job like that during a Annual Shutdown... in the times when Health and safety wasn't taken like it is today, but someone had broken a steam condensate line above him by a a Steam Calorifier above him, next thing a pump started and emptied hot condensate somewhere else on the plant and hot returned condensate water hit him down the back of the Neck...scared for life with third degree burns loads of skin grafts, never worked again... still in constant pain...Be SAFE, careful out there...Great Upload...

  • @Kevin-wj4ed
    @Kevin-wj4ed Рік тому +2

    Can tell no water treatment!

    • @johnwilcox4078
      @johnwilcox4078 9 місяців тому +3

      No water treatment, nobody blows down and tests those little #67 LWCO's. Because nobody cares.

    • @sc1338
      @sc1338 7 місяців тому +2

      @@johnwilcox4078I do every day at work cuz I’m bored 😂

    • @johnwilcox4078
      @johnwilcox4078 7 місяців тому +1

      @@sc1338 Well keep up the good work 👏 😉

    • @famousutopias
      @famousutopias 5 місяців тому

      As soon as I saw them just dumping the hot water content down the drain I figured there was no water treatment. Or at least not any more 🙂
      Also no one is doing internal inspections if those gaskets are like that, imo
      My two 125hp steam heating boilers have injection quills feeding water treatment and I tear them down every year for cleaning and inspection in the off season. I really don’t like surprises during heating season

  • @jeffgrant6914
    @jeffgrant6914 2 роки тому

    Good video 👍 buddy

  • @matthewclemons1574
    @matthewclemons1574 2 роки тому

    Highly recommend telling your employer you need a 36” or a 48”

  • @chippylc5262
    @chippylc5262 Рік тому

    I work on steam, LTHW, chilled water etc as an apprentice, recently experienced water hammer absolutely terrifying experience

  • @northface484
    @northface484 Рік тому +1

    I would not call those Large...LOL...

    • @johnwilcox4078
      @johnwilcox4078 9 місяців тому +1

      Me neither. Those boilers are only 50-100 hp, that's actually small. The guy said it's the first time he changed a manhole gasket,lol. But that #67 LWCO looks scary, should be a #150.

  • @vhj5803
    @vhj5803 2 роки тому

    Are you guys in NY required to have a stationary engineer license? Down here in Texas it’s required. Thanks for the videos

    • @williedelgado1082
      @williedelgado1082 2 роки тому

      Only if you're employed by that specific site. If you work for a boiler company, you don't need it

    • @EastDallasKicks
      @EastDallasKicks Рік тому

      What part of Texas you in?

  • @Kevin-wj4ed
    @Kevin-wj4ed Рік тому

    Steam boilers are a pain. Give me hot water boilers anytime!

  • @wrail5205
    @wrail5205 Рік тому

    Why did you replace the nuts ?

    • @JC-123
      @JC-123 Рік тому +1

      Why not?

  • @jneale7715
    @jneale7715 2 роки тому +1

    Watched less than 5 minutes. "Man look at that bolt"... Have you ever done engineering before!?

  • @northface484
    @northface484 Рік тому

    They over tightened the shit out of those nuts...Probably why it failed...

  • @williamsellner8855
    @williamsellner8855 6 місяців тому

    Where is the chief operating engineer?