How to Run Underground Power to a Shed the Easy Way

Поділитися
Вставка
  • Опубліковано 23 лис 2024

КОМЕНТАРІ • 503

  • @AprilWilkerson
    @AprilWilkerson  Рік тому +16

    Big thank you to FOREO for partnering with me on this video! Treat your significant other (or yourself) with a great gift by FOREO Sweden at the link below and don't forget to use the coupon code APRILW20 for 20% the UFO 2 collection here: foreo.se/o69q

    • @alexisbeeton5416
      @alexisbeeton5416 Рік тому +1

      I love to watch your videos - women really can do everything and you are right, we can look great too and I checked out this device, it really has cool features. Thank you!

    • @thedavesofourlives1
      @thedavesofourlives1 8 місяців тому

      get out your hair dryer/heat gun and make that down drop of PVC conform to the wall.

  • @pawsnazzy01
    @pawsnazzy01 Рік тому +46

    April, when running power to my shop build, My son had a piece of rag that he tied to some nylon string. He then went in to garage where the conduit was going to the main panel turned on the shop vac and it sucked that rag & string thru in about 2 seconds and he tied and taped the wire and pulled it back to the shop ,the whole thing took just a couple mins.

  • @michaelc.3812
    @michaelc.3812 Рік тому +131

    I’m sure others may have said the same, but it’s not allowed to run NM cable (some call it Romex, which is a trade name) in conduit that goes outdoors. If you are using cable that’s rated for direct burial, you should be okay (but good to check with inspector). So the wire from the panel to the junction box should be non-NM and something like THHN wires, but not standard NM). I’m a master electrician and ICC licensed electrical inspector.

    • @bruceyyyyy
      @bruceyyyyy Рік тому +5

      I did a similar install to get a lamp post in my yard. I used THHN in PVC conduit through the garage to an outlet on an exterior wall.
      From the GFCI exterior outlet I switched to UF-B cable but there is about 2' of UF-B in the conduit before it gets underground.
      Is this acceptable or should I change it?

    • @tomhackett3395
      @tomhackett3395 Рік тому +18

      I am still amazed that there's a type of cable that you just put in the ground directly exposed to the dirt?! Is it bad to run it within conduit for the entire length? I'm paranoid that moles will eat my electrical wires or something.

    • @jimmyyounger618
      @jimmyyounger618 Рік тому +12

      @@tomhackett3395 You should be fine. I opted for a buried primary service line instead of overhead wires for roughly a 100 yard run from the road to the house. From the meter to 2' under is in conduit, but the rest is direct burial. In service since '99 and never a problem despite driving tractors over the soppy ground above it and burrowing critters of every kind. Like you, I had my doubts but all's good! Likewise, I have various runs of direct burial lines to several outside locations and have never had an issue.

    • @kevinlynch3372
      @kevinlynch3372 Рік тому +3

      Curious what is the reason code won’t allow NM cable?

    • @lohnjones3307
      @lohnjones3307 Рік тому +16

      ​@@kevinlynch3372 It's not waterproof -it has paper inside

  • @ron827
    @ron827 Рік тому +200

    It is good practice to lay a yellow caution tape in the trench after some backfill has been added. When someone is digging in the area of the underground cable, they will encounter the caution tape before they get too close to the cable.

    • @jamesrawlings8493
      @jamesrawlings8493 Рік тому +11

      I believe the tape is required by the NEC.

    • @Windex451
      @Windex451 Рік тому +13

      I believe it should be Red

    • @hotpuppy1
      @hotpuppy1 Рік тому +3

      That won't do any good if the length of the shovel blade reaches the cable. Tile spade depth is pretty close. Caution tape won't provide any resistance.

    • @ron827
      @ron827 Рік тому +10

      @@hotpuppy1 Keep your day job. "-)

    • @txmade4371
      @txmade4371 Рік тому

      Naw.

  • @perrycollier2989
    @perrycollier2989 Рік тому +17

    April I used to work for a company that made a lubricant to pull electrical wires (romex). The lubricants are just glycerin so one might be able to save some money and just use glycerin. As always great video, very informative.

    • @normferguson2769
      @normferguson2769 7 місяців тому

      I have always used kitchen dish soap to lube the wire.

  • @dreport9433
    @dreport9433 Місяць тому +3

    This is the most informative tutorial, i have watched on youtube. No filler. No 8 minute introduction and watching you talk for those 8 minutes. You got to the point. You showed us. You educated us. Wonderful. Thank you.

    • @AprilWilkerson
      @AprilWilkerson  Місяць тому +1

      Thanks! Glad you enjoyed it. Thanks for watching.

  • @Aepek
    @Aepek Рік тому +7

    1:45 can also buy fittings to allow for different bends, if don’t wanna flex the conduit like this (sweep 90s, [also called elbows], street, bell ends, saddle bends, etc); and if don’t want to buy the different fittings (or can’t find), you can heat up and bend the conduit yourself (pvc only, as emt not gonna be heated and bend, gotta use a bender; and ABS doesn’t heat well and wouldn’t even try it, imo)…..just a tip for ppl if feel weird about flexing the conduit how April did.

  • @mattstosh6960
    @mattstosh6960 Рік тому +7

    I watched this video 3 times. You make this appear simple. I can't even find the same PVC pieces at Lowes or Home Depot. Love that ( 5:02 ) smile while dealing with not-so-easy cable. Thank you for the video....

    • @jimmac1185
      @jimmac1185 Рік тому +7

      They are in the electrical isle, not plumbing.

  • @jimmyyounger618
    @jimmyyounger618 Рік тому +37

    Good work! But I'll add that 20 years ago I didn't anticipate my similar project would be more permanent than I anticipated at the time. (My purpose then was to get power to a deicer at a livestock water tank.) During this period, the PVC outlet's year-over-year exposure to the sun caused it to degrade and become chalky, brittle and inflexible. A little post movement during an unusually wet year with a super freeze cracked the riser pipe, and the hinged cover on the outlet box fell apart. If I had a do-over, I'd have gone with metal over PVC despite the added work.

    • @hamadilawson4396
      @hamadilawson4396 Рік тому

      How much more resistant to corrosion is the pvs vs. meral conduit. It it emt conduit?

    • @TheHighKirk
      @TheHighKirk Рік тому +2

      There are different grades for the PVC.

  • @glencrandall7051
    @glencrandall7051 Рік тому +11

    The hard part is digging the trench for the wire. Thank you for sharing. Have a great day and stay safe. Be careful the electrons can bite.🙂🙂

    • @keithmyers1454
      @keithmyers1454 Рік тому +2

      It took my wife two weeks to dig a 20 ft trench so I could put the wires into it, she ran into a lot of rocks, she did cover it up faster though

    • @dougb8207
      @dougb8207 11 місяців тому +3

      That's actually what I was hoping to see taught, when I clicked on the video. I've heard water pressure, maybe a pressure washer, can be a good way to go.

  • @josephknapick5307
    @josephknapick5307 Рік тому +174

    Your first run of Romex to the GFCI is a code no-no, even inside of PVC conduit. NM cable (ROMEX) is not permitted in damp or wet locations [NEC 334.12B(4)] and the inside of raceways (including PVC conduit) located outdoors is considered a wet location per NEC 300.9. Your first run should be UF cable or individual THWN conductors. If the latter, the individual conductors should be placed in conduit all the way to the source panel.

    • @jackww839
      @jackww839 Рік тому +13

      Texas has very lenient/substandard codes.😒

    • @rayrayber_
      @rayrayber_ Рік тому +6

      This is texas are codes are different from were ur from I can see

    • @DragCadRacing
      @DragCadRacing Рік тому +8

      At about 3:30, the text box says “UF cable”.

    • @josephknapick5307
      @josephknapick5307 Рік тому +5

      @@DragCadRacing Prior to that, ROMEX is used from the inside to the GFCI box....

    • @simsreject5925
      @simsreject5925 Рік тому +20

      ​@@rayrayber_ The N in NEC stands for national. These are unified codes adopted by many states, including TX, as the baseline for electrical and fire safety.

  • @jljohnson9438
    @jljohnson9438 Рік тому +5

    This video was at just the right time as I am getting ready to feed electricity from my old shed to the new garage that is right next to the shed. Watching you do this is the exact same process that I will need. Thank you.

  • @danstewart7316
    @danstewart7316 Рік тому +6

    I saw others mention the romex issue so check those comments out. I would mention that any electrical pvc pipe exposed needs to be schedule 80 and not your typical schedule 40. I am impressed with your knowledge of the burial depths, not many know that.

    • @daveroth8060
      @daveroth8060 Рік тому

      It does not have to be SCH 80

    • @njineermike
      @njineermike Рік тому +2

      ​@@daveroth8060 Yes it does. It can be sch 40 below 18" or inside the structure, but above ground and outside it must be sch 80.

  • @antzlowe7529
    @antzlowe7529 Рік тому +3

    Hey April I am a beginner woodworker from New Zealand and I have watched I think all of your videos. I cant thank you enough for all your talant and know how. You explain everything so beginners like me can do anything when it comes to woodworking. I have subcribed to your channel and look forward to seeing alot more videos once again thank you.

  • @dennishinkle5010
    @dennishinkle5010 Рік тому +3

    I ran direct burial wire and stayed away from PVC. A little extra work but worth it. You are truly great.👍♥️

    • @alamofox1
      @alamofox1 Рік тому +7

      Physical protection is required when emerging from grade.

  • @georgevanvalkenburg2560
    @georgevanvalkenburg2560 Рік тому +8

    ALWAYS READ THE COMMENTS. THE BRILLIANCE OF A COMMENTER IS NEVER OVERSTATED!

  • @Gk2003m
    @Gk2003m 11 місяців тому +4

    There is flexible conduit, outdoor rated. I used that to run AC, along with outdoor-rated speaker wire, out to my shed. The great benefits: a) flexibility allows you to maneuver around large underground obstacles; b) zero underground junctions, so no leakage or seepage of water into your conduit. It’s been a godsend for Xmas lighting, as well as for outdoor stereo audio. I can run a powered subwoofer. The garden sounds amazing

    • @MelissaHuffman-k7x
      @MelissaHuffman-k7x 6 місяців тому

      Electric code only allows a maximum of 6’ of use, for flexible conduit.

    • @Gk2003m
      @Gk2003m 6 місяців тому

      @@MelissaHuffman-k7x only if the flexible conduit has no reinforcement. Mine is reinforced conduit, and is therefore up to code.

  • @jonathanm9436
    @jonathanm9436 Рік тому +32

    Interesting code requirements. By comparison, in Australia we are required to bury the wire in conduit the whole way at 600mm (2ft), with warning tape just above the conduit. It can be shallower (not sure how much) if there is mechanical protection like concrete.

    • @Outback_Truckie
      @Outback_Truckie Рік тому +7

      Don't forget we also have to use a licenced electrician for all electrical work. 👍

    • @jonathanm9436
      @jonathanm9436 Рік тому +2

      @@Outback_Truckie True dat. 240 scares me!

    • @w.knudsen5570
      @w.knudsen5570 Рік тому +3

      Here in the states, uf rated wire may be used for direct burial.

    • @mellowrebel4618
      @mellowrebel4618 Рік тому +1

      @@Outback_Truckie WE DO HERE.HER I SHE NEEDED TO ALSO PULL A PERMIT!!!

    • @alamofox1
      @alamofox1 Рік тому +4

      US NEC also requires a minimum cover of 24 inches. There is an exception that allows 12 inches but she didn’t discuss this.

  • @clinttalmadge796
    @clinttalmadge796 10 місяців тому +9

    Not including an advisory about the length of the wire run and amperage draw dictating the gauge of the wire needed can set a dangerous situation. As a clerk in the electrical department of a large DIY store, I had many customers who wanted to run 14 or 12 gauge wire in excess of 100' to run shop equipment in an stand alone workshop. I calculated on one case that the fellow would need 4 gauge for what he was proposing. He accused me of trying to make more money off him. I told him that I was paid by the hour and I made the same if he bought the right wire, the wrong wire or no wire at all. Please consider adding such advice.

  • @mach51
    @mach51 Рік тому +8

    Nice, you can use heat gun to form the plastic conduit to fit flush against the wall

  • @lucianprescott8357
    @lucianprescott8357 Рік тому +4

    Every electrical video I’ve ever watched will state “if your not comfortable doing this work, call in an electrician”, which is sound advice. However, anyone can do the manual labor (digging trenches, running the wire, backfilling) prior to calling in the electrician, thus saving a ton of money.
    Had a project similar and ran a line 75’ from a house panel to a garage. Found out the code requirements, did the labor and then call the electrician. He was happy, because I had set up everything for him and all he had to do was set the wires in proper order. Saved 15 hundred on the project by doing some of the work myself.

    • @rosewoodsteel6656
      @rosewoodsteel6656 11 місяців тому +1

      Good advice for those afraid of doing this type of work.

  • @1956arc
    @1956arc Рік тому +4

    Nice job!
    It is important to understand voltage and amperage needs to be considered when determining depth of wire. A residential 20 amp circuit using 12/2 copper underground rated cable can be installed at a 12” depth as long as it is protected with GFCI device.
    Electrical codes can be more stringent depending on where you live so please consult an electrician or electrical inspector in your area.
    Also it is important to note that schedule 80 pvc should be used in this application.

  • @davidhoover2446
    @davidhoover2446 Рік тому +4

    Nice easy description. Don’t forget to water/air/bug seal the holes once finished.

  • @timruff9515
    @timruff9515 Рік тому +24

    Just remember you could have just back fed the underground cable so you only had to pull 5 feet or so rather than feeding all the cable through the box...

    • @bishopp14
      @bishopp14 Рік тому +4

      Yeah, I was thinking the same thing. Great video though!

  • @abbayhvhreigns7iloveyeshua650
    @abbayhvhreigns7iloveyeshua650 Рік тому +4

    Another quick project Wonderfully explained. This is time well spent on a Sunday. Thank you April, See you again Soon. Have a Blessed Week.

  • @jimpovolish540
    @jimpovolish540 Рік тому +6

    conduit the full run is a good idea as well and not much more expense and also don't forget to silicone seal those LB boxes at the building to prevent water penetration!

    • @jimurrata6785
      @jimurrata6785 Рік тому +1

      You're not supposed to run Romex in conduit. (it can guard Romex in accessable areas)
      Sealant definitely, but more likely ductseal than silicone, and possibly intumescent sealant if habitable space. Depending on AHJ

    • @luvdady
      @luvdady 9 місяців тому +1

      ​@@jimurrata6785old tale ..
      But it's definitely not fun to do compared to stranded

    • @jimurrata6785
      @jimurrata6785 9 місяців тому +1

      @@luvdady Well, I just pulled 100' of 10/3 in 3/4!!! So I hope it's good.
      Thanks for your reply! 😉

  • @ThraX_86
    @ThraX_86 Рік тому +15

    Hey April,
    Great video. The nice thing about PVC is if you run into this later on with a project again, you could use a heat gun and apply a slight offset off the metal building over the concrete lip into the ground (1:43). By just applying a few minutes of heat along the pipe, you can shape it without any fittings. I used to do this when I was an apprentice electrician years ago, and it would work great on jobs.

  • @tsjuno
    @tsjuno Рік тому +13

    I feel like it’s easier to just run the pvc underground all the way and pull in stranded wire after. I hate fighting solid wire.

    • @rosewoodsteel6656
      @rosewoodsteel6656 11 місяців тому

      I totally agree, TsJuno. In this case, she didn't run the UF in conduit the entire run, just in the vertical drops to protect the cable from grade to the wall penetrations.

  • @tsquare9168
    @tsquare9168 Рік тому +20

    You didn't put a service loop on the cable in the LB box. Where you used your foot to bend the conduit to the wall, heating the pipe with a torch would allow for you to bend the pipe to fit the contour of the wall. Also, the conduit where you fitted the male connnector, you can ream the inner edge to a smooth and tapered edge that's no longer sharp.

    • @LG-ve9us
      @LG-ve9us 7 місяців тому

      service loops are not required by code.

  • @RyanBrem0504
    @RyanBrem0504 Рік тому +12

    Another thing: if you do put in a gfci or outlet outside, be sure it is a weather proof

  • @Immolate62
    @Immolate62 Рік тому

    Just did a similar project running 50 amp service from from "main" panel to my shop (who builds an 1,100 sq ft shop with only two 15 amp circuits?). I had to chase it across the entire attic in the house so I used 6 AWG Romex to the edge of the house with no conduit, then put a junction box to connect to 3/4 inch flexible conduit. The conduit came down the wall outside, buried two feet under ground for a 13 foot run across to the shop then up to an LB and into the shop, all one continuous 38' bit of conduit and using 6AWG THHN. The shop is 32x32 concrete block. The conduit continues inside for the very short run to the sub panel (about 18").
    I could have gotten away with an 18" burial, or I could have used UF to simplify things a bit, but I'm glad I went the way I did.
    I had a good friend who is a licensed electrician help me with the attic work since I'm too old and inflexible for that rather cramped space. It was really just securing the Romex and splicing the Romex to the THHN in the junction box. He knocked it out in under an hour. Thankfully it was a reasonable cool Florida day in March with heavy cloud cover, so the attic wasn't dangerously hot, which is the default setting for Florida. I did the trenching myself, and learned all about the surprisingly lax codes for PVC thickness and burial depth for irrigation in Florida. Don't ask me how I know. Let's just say that if you made a pipe out of Playdoh, it would be sturdier.

  • @nyetloki
    @nyetloki 6 місяців тому +1

    Just to clarify, the GFCI should be BEFORE the underground cable run, not just anywhere on the circuit. So at the panel (gfc breaker) or an intermediate GFCI outlet as you did.

  • @bobniles1928
    @bobniles1928 Рік тому +58

    The Romex you used from the panel to the outside receptacle is a violation. Conduit outside is a wet location. You should have used UF.

    • @michaeld9682
      @michaeld9682 Рік тому

      Link please

    • @bobniles1928
      @bobniles1928 Рік тому +2

      310.1 O(C)

    • @jakesmith2341
      @jakesmith2341 Рік тому +2

      Thank you. I won't make the same mistake. Hopefully it won't make a difference either way.

    • @scwfan08
      @scwfan08 Рік тому +1

      Like it says on the screen at 3:28.
      So she didn't even follow the rules she statet herself 😂

    • @GageDrums
      @GageDrums Рік тому +5

      @@scwfan08 lmao yup.. UF.. Underground feed.. Not nm-b.. Crazy people with no research make how-to videos. She also did 220v outlets in her garage and ran multiple outlets off the same breaker.. For 220v..she shouldn't be making electrical tutorials lol

  • @wayneburba9457
    @wayneburba9457 Рік тому +3

    For your offsets near building, instead of your foot, a happier blow dryer or heat gun on low slowly over conduit will mold conduit .

  • @rubenmorales5830
    @rubenmorales5830 9 місяців тому

    Your awesome April I wish I had half the talent you have! Thank you for all you do!

  • @tjanecki
    @tjanecki Рік тому +1

    What a great vid, thank you! Also like the helpful and respectful comments. Thanks everyone!

  • @mikeslater6246
    @mikeslater6246 Місяць тому

    I see a lot of good information from other commenters about using underground as opposed to romex. I've heard this from other sources. The only thing that I would add to the comments about this video is instead of running the full length of the cable that's going to start at your GFCI through that piece of conduit going into the ground and then to the shed, I would pull a string into that conduit and then pull the three or four feet necessary from the underground exit point of the conduit back up to the GFCI outlet box.

  • @sherwoodstolt1027
    @sherwoodstolt1027 3 місяці тому

    In my county you also need to pay a small fee, get a permit and have it inspected prior to filling the trench. Later on if you sell the house, get a new mortgage or get homeowners insurance they will make you to sign a form stating no electrical work was done without a permit and inspection.

  • @WillysPerformanceCycleCtr
    @WillysPerformanceCycleCtr Рік тому +10

    This is a great idea and instruction set. I have a detached building that I need to run power to and will use your method! Thanks so much for your intuitive videos! Have a great day April!

  • @sparkythebuilder
    @sparkythebuilder Рік тому +15

    Nice job. The only thing I saw that was not correct is you ran standard NM-b cable from the inside to the box that will have the GFCI. NM cable is not rated for wet locations and any conduit installed outside is considered a wet location due to condensation. To get around this you can run the cable directly into the back of the box that will have the GFCI.

    • @k4x4map46
      @k4x4map46 Рік тому

      yeah I was going to ask that very same question even looking up the romex color codes...great observation!

    • @NiHaoMike64
      @NiHaoMike64 Рік тому

      Or put the GFCI indoors, that will protect the GFCI itself from temperature extremes so it would last longer and provide a good place to plug in a Homeplug adapter for extending network to the remote location.

    • @gregbell2117
      @gregbell2117 Рік тому +1

      I thought GFCIs only protected what was plugged into them, not the circuit they were on?

    • @sparkythebuilder
      @sparkythebuilder Рік тому +5

      @@gregbell2117 You can wire them to protect everything downstream of the GFCI by using the LOAD terminals on the device.

    • @rupe53
      @rupe53 Рік тому

      @@NiHaoMike64 ... these days they make GFCI outlets with WR printed on them to mean WET RATED so they will last outside.

  • @olddawgdreaming5715
    @olddawgdreaming5715 Рік тому +2

    Thanks for sharing April, worked out good and SAFE too. Fred.

  • @w.knudsen5570
    @w.knudsen5570 Рік тому +2

    Code for how deep to run your conductor is 24 inches without protection. If the run is under a sidewalk, driveway, etc you may have it 12 inches under such protection. Recheck the NEC. I did when I ran power to my shed a year a year ago. It had not changed since I was in a NEC class back in the 90's.

    • @kevinbowers4394
      @kevinbowers4394 Рік тому +5

      Column 4 of table 300.5 in the NEC is what she referenced for her depth. She's running a single 20A 120V circuit with a GFCI and that allows her to use that 12" depth.

    • @nyetloki
      @nyetloki 11 місяців тому +1

      GFCI is the protection, for a 120v 20a circuit with a UFb rated cable.

    • @LG-ve9us
      @LG-ve9us 7 місяців тому

      @@kevinbowers4394 yep, people gotta read all the code, it's not always clear at first glance...

  • @rebrus1930
    @rebrus1930 Рік тому +1

    Wow! You just solved an issue for me, I was just looking at it wrong, Thanks!

  • @Aepek
    @Aepek Рік тому +9

    Always have fun watching and seeing what you do next April. Your vids are always fun, filled with different info; and can tell you enjoy doing each project 👍🏻
    Also do like the voiceover and are always TALKING TO US, every step of the way, thx.
    Cheers✌🏻

    • @AprilWilkerson
      @AprilWilkerson  Рік тому +4

      Thanks! Glad you like them. Thanks for watching.

  • @louroberts5567
    @louroberts5567 Рік тому +1

    Good morning, April! Thanks for another great video. This project is actually penciled in on my "GET IT DONE" list for the warmer weather. Have a great week! God bless.

  • @dcfan1107
    @dcfan1107 Рік тому

    PM screwdriver...cool. I bought a couple of sets from Walmart back in the mid 90's. Made in USA. Never seen anyone else use them. Still have them.

  • @richardphillips2405
    @richardphillips2405 5 днів тому

    Great video. I was wondering if the open pvc in the ground would allow insects to get into the house or building.

  • @dalematherly5394
    @dalematherly5394 Рік тому +3

    Others may have said it, but direct bury cable has to be 2’ deep regardless of what material your risers are.
    Shallower permitted if entire run in conduit.
    This is to protect wire from damage from digging.

    • @nyetloki
      @nyetloki 11 місяців тому

      False. GFCI protected UFB cable on a 120v 20a circuit can be direct buried at 12 inches.

    • @TheHavocdog
      @TheHavocdog 7 місяців тому

      ​@nyetloki Only in schedule 80 conduit.

  • @deview123
    @deview123 Рік тому +4

    I take it that Romex wire you used was solid wire? When I did underground wire pulls, I always ran conduit from one end to the other, then pulled stranded wire. It’s a little extra work, but it’s easier for one person. Thank you April for another great video

    • @daveroth8060
      @daveroth8060 Рік тому

      They don’t make stranded Romex cable fool.

    • @deview123
      @deview123 Рік тому +1

      @@daveroth8060 yes I know. I was referring to thnn individual stranded wire

    • @rosewoodsteel6656
      @rosewoodsteel6656 11 місяців тому

      No $hit Sherlock. @@daveroth8060

  • @robertjames-life4768
    @robertjames-life4768 Рік тому +3

    A fish tape also helps get wire through conduit. 👍

  • @lnsdetailingmechanical5440
    @lnsdetailingmechanical5440 Рік тому +5

    In Australia we need to be 600mm minimum deep with warning tape 100mm above the conduit. Also pull your cable through first then make you joins. It makes for a much easier and quicker job without the struggle. Anyway different regulations for different states and countries. Good to see your having a go and not scared to get your hands dirty 😊well done and look forward to seeing your next job 👍👍

    • @alamofox1
      @alamofox1 Рік тому +1

      She is in violation of NEC 300.5. 24 inch minimum cover for direct buried cable.

    • @LG-ve9us
      @LG-ve9us 7 місяців тому

      @@alamofox1 no, 24 inch min for direct buried cable if not GFCI protected... she alludes to this in the video... 300.5 column 4. 12 inch if GFCI protected and 20 amp max circuit.

  • @electricianron_New_Jersey
    @electricianron_New_Jersey Рік тому +1

    It's decent but here in the northeast the UF (which stands for "underground feeder") will undoubtedly fail. I fix and repair stuff like this all the time and always install the PVC for the full run.

  • @71160000
    @71160000 Рік тому +2

    When using an LB you always want to bring the wire into the LB through the long straight side and out the 90 degree side. Doing it backwards as you did with the first LB makes it far more difficult.

  • @dienekes4364
    @dienekes4364 Рік тому +2

    It would have been nice to show how you wired that into the breaker box. Once in the shed, that wire could go anywhere; into a sub-panel, into a single outlet, into a lighting setup, but wiring it into the breaker box at the source is pretty much the only option (unless, maybe, you are connecting to an existing plug?).

  • @DanO530.8
    @DanO530.8 22 дні тому

    Ive always put the wire in each piece first especially corners or elbows then i would glue the conduit just depends on the job really and anyone’s preference.

  • @James-mv9qx
    @James-mv9qx Рік тому +2

    In Australia we are not allowed to do any electrical work without a licensed electrician, even changing a switch or wall socket! If you do it on your own, home insurance will not pay out if your house burns down. It's costing me about US $4000 to run single phase power about 200 feet to my shed.

    • @jefffrayer8238
      @jefffrayer8238 Рік тому +2

      Yup, need more goverment running every little thing in our lives.

    • @rosewoodsteel6656
      @rosewoodsteel6656 11 місяців тому

      I'd make sure my insurance company didn't know that I changed out the switch. :)

    • @rosewoodsteel6656
      @rosewoodsteel6656 11 місяців тому

      Yep. It took me 6 months and a variance for my county to grant me a permit to build my shed. They took $300 for the permit/variance and didn't even require an inspection. -Just big brother grabbing a piece of the action..@@jefffrayer8238

  • @albatross5466
    @albatross5466 Рік тому +6

    The conduit coming out of the ground should have an expansion joint. You don't need to use UF cable, you can use any cable that has an insulation rated for wet applications. THNW is a lot easier to pull. UF can be used for direct burial. The 12' burial is for 125V max 20 A max.

    • @Zach_Miller
      @Zach_Miller Рік тому +2

      This was direct burial

    • @albatross5466
      @albatross5466 Рік тому +1

      @@Zach_Miller I thought I saw a conduit from grade to the cabinet. No?

    • @jacobrobbins6181
      @jacobrobbins6181 Рік тому +1

      ​@@albatross5466The conduit was only used to get the cable to the bottom of the trench on either end. She didn't run pipe the length of the trench.

    • @nyetloki
      @nyetloki 11 місяців тому

      ​@@albatross5466 you have to protect the UFB from depth to above. Anything above depth up to 8 feet needs conduit.

    • @albatross5466
      @albatross5466 11 місяців тому

      @@nyetloki I incorrectly assumed that she had run conduit for the full length of the trench. Others have pointed out my misunderstanding. Thanks and Merry Christmas.

  • @username-mc7jw
    @username-mc7jw 8 місяців тому

    Exactly how I ran power to my back-yard cabin. Perfect!

  • @TexasCanuck
    @TexasCanuck Рік тому +3

    the hard part is digging the trench - that is the part I thought you found an "easy" way to do :)

  • @felixfromnebraska8648
    @felixfromnebraska8648 Рік тому +2

    Thank you, April. I enjoy your videos very much. They are continuously researched and demonstrated perfectly.
    Thanks for all you do in the community. Felix

  • @DoctorNoMD
    @DoctorNoMD Рік тому +1

    Thanks for this video, April. I'm thinking about a project in our yard, and this gave me some great things to think about in my planning.

    • @AprilWilkerson
      @AprilWilkerson  Рік тому

      Awesome! Glad it was helpful. Thanks for watching.

  • @garageworker
    @garageworker Рік тому +9

    You are very brave to show an electrical project on UA-cam.

    • @LG-ve9us
      @LG-ve9us 7 місяців тому +1

      lol, yeah all the armchair inspectors come out of the woodwork...

  • @JohnMark1313
    @JohnMark1313 9 місяців тому

    It is good to check local codes. You mention the depth using pvc and a gfci but looks like you only used that to get into the trench and actually ran the UF cable by itself in the trench. Here, that would be more like 24" deep. They do sell fittings for rigid conduit that are compression so no bending or threading needed.

  • @benh554
    @benh554 Рік тому

    in a pinch for small diy wire pulling projects, liquid hand soaps works just as well

  • @JeronimoStilton14
    @JeronimoStilton14 Рік тому +1

    Not sure how I feel about that strap on the outside. Leaving polymers in a stretched configuration can lead to creep, or in the winter could snap. PVC may be slightly resistive I don't feel like consulting my textbooks over it but just something to consider. I am sure they make small curve segments for the PVC.

  • @Mikidy303
    @Mikidy303 Рік тому +10

    I'm torn. I'm too lazy to do this myself, and I'm too cheap to pay someone to do it for me. I guess I'll keep running an extension cord to my neighbor's house until I get motivated.

    • @jefffrayer8238
      @jefffrayer8238 Рік тому

      April really does nice work but I'll do it my way. It's just a shed, not a machine shop. Nothing that a 14ga, especially a 12 ga. extension cord can't handle. Outside house plug is Ground Fault protected so just plug it in, bury it under grass and call it good. If someone hits it with shovel nobody gets hurt because of ground fault. Extension cord would probably last 15 years but if insulation does break down ground fault shuts it off. If ya sell the place just cut cord off below ground and let next owner worry about it. Out buildings add little value, wired or not.

    • @jimmac1185
      @jimmac1185 Рік тому

      @@jefffrayer8238 If the shovel only hit the hot wire, the GFCI would do nothing and that would still be a dangerous situation.

    • @LG-ve9us
      @LG-ve9us 7 місяців тому

      @@jimmac1185 no, if the hot wire is faulted the GFCI will trigger.

    • @jimmac1185
      @jimmac1185 7 місяців тому

      @@LG-ve9us gfci stands for ground fault circuit interruption. If there is no ground fault, there is no interruption. An AFCI would trip in this instance, but not a GFCI.
      Unless you are saying the “ground” would be contact with the dirt? Maybe, if it was really wet it might trip.
      Also, my comment was from a year ago, I don’t remember what is going on in this video and I’m not going to watch it again.

  • @nusermane1076
    @nusermane1076 Рік тому +3

    Nice video again 👍
    Consider adding also Ethernet cable whenever you run cables between or in buildings, it comes in sooooo handy if you need to expand your Wi-Fi on your property … yes, Wi-Fi mesh works, but there are many draw-backs, so good ol‘ wire is a good thing to put in.
    If you can use cat7, from my experience it’s not much more expensive than cat6(a), but shields against all kinds of interferences ;)
    Cheers 🥂

    • @royreynolds108
      @royreynolds108 Рік тому +3

      Ethernet cable nor coax should be included together with power wires in the same conduit. Use separate conduits in the same trench.

    • @nusermane1076
      @nusermane1076 Рік тому +3

      @@royreynolds108 Yes, that’s true.
      And, even if direct burial wires are a thing, conduit between buildings is definitely worth it, to avoid digging later again, if some changes are needed 😉

    • @canlib
      @canlib Рік тому

      Nah

    • @jack6539
      @jack6539 10 місяців тому

      If running copper utp cable, your nw performance will suck badly. Running utp in parallel with power without shielding is guaranteed to hobble your performance. Worst case I saw was when some Muppet actually wound the utp around the power cable. If using fibre, no problem ( but b3st to have it in its own conduit as its more fragile. Standards state that utp must only cross power cables at a 90degree angle.

  • @HighCountryRambler
    @HighCountryRambler Рік тому

    Great work April. I was running a direct burial line out to my barn, I flunked my inspection because I crossed a driveway at 16" depth, not 18". Geeezz.

    • @RobertBeck-pp2ru
      @RobertBeck-pp2ru Рік тому

      Codes are meant to be followed. Eighteen inches is the minimum. Play it safe. Go 24" or even 30".

    • @HighCountryRambler
      @HighCountryRambler Рік тому +1

      @@turdferguson12 I live on a ranch in very rural Colorado out in the middle of God's country. Prior to building the house I built a barn, I was bringing new service in from county roads to barn (4 miles). The only way ANY public utility will bring in new service is with a electrical permit, which are governed by states who share the same codes.
      I chose to trench 2 inches deeper, rather than spending winter and nights freezing in the dark. Plus my welders and barn heaters don't make good pasture ornaments.

    • @SmallSpoonBrigade
      @SmallSpoonBrigade Рік тому

      @@RobertBeck-pp2ru Yes, the code is intended to be more or less the minimum that is acceptable. You can go above it to the extent that the gear and budget exists, but code does get updated over time for situations where it proved to be insufficient.
      It may not seem like some of this is a problem, but things like the spacing on outlets does typically address a problem, just not always an obvious one.

  • @BigGuy8059
    @BigGuy8059 Рік тому +4

    In my state, conduit can't have Romex in it. It has to be THHN individual wires. Also, PVC or direct burial Romex has to be down 20 inches, unless you have concrete above it. And you left out the part about the building inspector having to measure and approve your trench depth before you fill it in. But of course, every place can have different rules and procedures. It pays to find out your area rules.

    • @lstownley
      @lstownley Рік тому +1

      12" depth ok for direct burial cable where ...residential...

    • @rosewoodsteel6656
      @rosewoodsteel6656 11 місяців тому

      The conduit is only protecting the vertical drop at the buildings. There should be no problem with this in your area if you are using type UF Romex, like April is using. What code # indicates this?

  • @donfrank4429
    @donfrank4429 Рік тому +1

    just ran 10/2 UF to my BBQ shed in conduit into a sub panel, with 2 8 ft grounding rods

  • @mafosa8519
    @mafosa8519 Рік тому

    Sometimes heating the cable at the turning point helps it bend easier.
    In cold climates the outer coating can micro crack.
    Nice job though!
    Larry

  • @lorenmeyer5290
    @lorenmeyer5290 Рік тому +1

    Always love watching and listening to your install April!

    • @AprilWilkerson
      @AprilWilkerson  Рік тому

      Thanks! I'm glad you enjoy my channel. Thanks for watching.

  • @stevewilde4430
    @stevewilde4430 3 місяці тому

    Hi April, great video. I am wiring a new shed. When I attach my LB fitting to the outside of my home, and also the shed, and add a small length of pvc conduit to the LB fitting to get through my shed and also the rim joist of my home, can I switch over to a metal junction box on the inside of my shed and also the inside of my rim joist? From there, I would run to my breaker box for in the home. I would also run inside wire within my shed to any new outlets, switches, lights, etc. from the junction box in my shed. Thanks

  • @durangodave
    @durangodave Рік тому

    you can also use a heatgun to heat the conduit and shape it how you need it. this saves stress on the straps

  • @HomeDIYSStuff
    @HomeDIYSStuff 2 дні тому

    Let the hole saw work. Manhandling it will cause it to split in half over time. The housing can't take that rough handling unless it's all metal. Heat the tubing to shape it. Any heat gun will work. lol Otherwise over time it'll pull the screws out. Take your time and think it thru. You go girl!

  • @ForgetU
    @ForgetU Рік тому +4

    Put gfci inside garage and pass your wire as you did. gfci won't need waterproof box.

  • @hunterscott7592
    @hunterscott7592 Рік тому

    I do similar things on my properties…however I like to run continuous conduit in case I need to add another wire or upgrade the installed wire sometime down the line

  • @bobbycorrigan7969
    @bobbycorrigan7969 26 днів тому

    I used direct burial to my shed. But you did good job.

  • @timothydeering1695
    @timothydeering1695 Рік тому +1

    Romex was not allowed in conduit years ago. Has that changed?

  • @TheHavocdog
    @TheHavocdog 7 місяців тому +1

    I didn't see any strain relief for the conduit going into the ground. The conduit can be heaved or pulled down due to frost.

  • @adambilal42
    @adambilal42 Рік тому +1

    all the best april
    New ideas thank you

  • @williamwinder3466
    @williamwinder3466 Рік тому +3

    1:25 You need to ream the inside of the pipe. The inner edge can damage the wire.

  • @BearCreekWoodworking
    @BearCreekWoodworking Рік тому +3

    It seems to me that so many content creators avoid showing electrical installations on the videos. However, April you are brave enough to make electrical videos time and time again. Congrats to your “Can Do Spirit “!!! 😃👏

    • @AprilWilkerson
      @AprilWilkerson  Рік тому +1

      Thanks! Yes, people love to rake me over the coals for these videos but always show what I did and how I did it. Thanks for always watching.

    • @DanTheisen
      @DanTheisen Рік тому +5

      True. Content creators who are not electricians really should not, in my opinion, demo electrical work. I do a little work around my house, have consulted electricians about what I do, but I won’t put electrical work on video. I love April’s channel and work, but don’t consider showing clear code violations as “brave”.

    • @richardroffers2530
      @richardroffers2530 Рік тому +1

      @@DanTheisen Well stated. I agree 100%...IMO, read the code. Follow it. If something is not clear, ask an electrician. Do the work, but don't advertise it.

    • @rosewoodsteel6656
      @rosewoodsteel6656 11 місяців тому

      What were her violations, Dan? @@DanTheisen

    • @DanTheisen
      @DanTheisen 11 місяців тому

      @@rosewoodsteel6656 read the top rated comment. The one right under April’s. And please know my words are directed at Bear Creek’s comment. I continue to watch all of April’s videos and love what she does, generally.

  • @caseycooper5615
    @caseycooper5615 Рік тому

    I've never fully understood the attraction of UF cable. If you have already dug the trench, why not use PVC the whole way? In my estimation, this allows wire to be upsized when needed without digging a new trench. Plus, UF cable is so challenging to cut and work with, not to mention its lack of mechanical protection.
    But that's my little nitpick. I appreciate how well you presented everything.

    • @SmallSpoonBrigade
      @SmallSpoonBrigade Рік тому

      I think the only benefit is that if you have to rerun the wire, fishing it around two 90 degree angles can be a pain. But, by the same token, if you've got the wiring through properly sealed conduits the entire way, the likelihood of needing to do so is also greatly reduced.
      Also,it's worth using a bit of sand around the wire/conduit in the ground. It makes repair and replacement easier and if you decide you need a larger, conduit it's easier to remove the one you've got. Plus, it's a bit of a warning to anybody that is digging that there's this sudden unexplained sand coming up, perhaps there's a wire or a pipe down there.

  • @brentbeatty4171
    @brentbeatty4171 7 місяців тому

    Thank you for your time making this video

  • @jonanderson5137
    @jonanderson5137 2 місяці тому

    With all the digging and time invested, people should consider bringing a sub-panel to sheds and garages.

  • @craigyarmulasr1845
    @craigyarmulasr1845 Рік тому

    Great video. I didn't realize how many different code's there could be. Very informative.

  • @DrGreenGiant
    @DrGreenGiant Рік тому +9

    Very interesting to see different electric standards across the world! This wouldn't be legal here in the UK.
    Might be worth specifying in your video which standards you come under when doing work on electrical work so people don't get (unintentionally) misled into doing something dangerous because they trusted you.

    • @JonEHolland
      @JonEHolland Рік тому +6

      This isn’t legal in the US either.

    • @rosewoodsteel6656
      @rosewoodsteel6656 11 місяців тому

      Other than her not being a licensed electrician, could you name the code violations, Jon? I'd like to know what she did wrong, not trying to be a pita. @@JonEHolland

  • @raterus
    @raterus Рік тому

    I had to do something very similar when I installed wiring to my well house during the construction of my home. I'm not an electrician, and this wasn't exactly "easy", it's just the way it has to be done! You don't want to do in-ground electrical work the wrong way though!

  • @frederickwise5238
    @frederickwise5238 Рік тому

    Yep ran such a line with underground #10 cable and conduit, out to my pond and on to my outbuilding. So my next door neighbor runs an extension cord thru the fence and uses my electricity at his outbuilding. Im gonna have to break the line at the pond and rig a way to disconnect the rest of the line till its needed.

  • @jrpritchard1622
    @jrpritchard1622 Рік тому

    great video thanks for sharing the tips with the pvc conduit have a great week

  • @hotpuppy1
    @hotpuppy1 Рік тому

    If you are going to go that shallow, best to place a layer of sand over the wire then concrete patio blocks over the sand so that if anyone hits it with a shovel, they will know something is down there. Yes the GFCI will shut off the power, but who wants to go through the trouble of fixing a cut cable?

  • @shopart1488
    @shopart1488 7 місяців тому

    I believe you will find romex is not all in conduit which is ran outdoors. You may want to check this out for sure. I know we do not do that in the area I live in.

  • @kennethtomlinson9617
    @kennethtomlinson9617 Рік тому

    Love your work, ma'am, an good to see a fellow Texan !

  • @عبودالتركي-د7خ
    @عبودالتركي-د7خ Рік тому

    Very beautiful work. I also love carpentry

  • @Aepek
    @Aepek Рік тому +3

    4:45 haven’t finished watching the vid (so it’s possible what about to add as a tip was used)
    Another TIP for outside or anywhere using conduit or fittings or penetrating structures w/ holes and want to seal up holes for bug protection and weather……DUCT SEAL. Great stuff that has been around and used for very long time, and comes in bricks or small tubs (similar to spackle containers, but I’d pay for the brick kind as usually cost usually less when compared to amount getting, and can use in many different places and save it for future use). Also, yes, “can” fire stop and caulk the penetrations and in some areas I’d go that route, but say inside an LB, Duct Seal is what want to use, NOT any type of product that comes in caulk tube, imo, as can be difficult & messy. Also, yes, for ppl who gonna ask or want to know, can use the correct rated spray foam type material for inside electrics, fittings to seal up holes/air gaps, and then can caulk with exterior sealant etc….around the LB for more protection).
    Ok, back to the vid😁✌🏻

  • @ryanhamilton9709
    @ryanhamilton9709 6 місяців тому

    I do think you are a hard worker and u r very knowledgeable on electric wiring sorry for the stupid comments I made

  • @Jcewazhere
    @Jcewazhere Рік тому

    How about a catio to go with the notacat door from a while back?
    It'd probably be similar to the composter you made, lots of hardware fabric and dimensional lumber.

  • @EagleMacCassady
    @EagleMacCassady Рік тому

    I dont know what the NEC is where you are, but it is not recommended to run romex in conduit, it can get really hot being that it cant breath, the sheath on the romex needs to breath, romex is intended to be run on its own, that's why the sheath is put on it, when running in conduit you should use THHN/THWN wire.

    • @rosewoodsteel6656
      @rosewoodsteel6656 11 місяців тому

      What NEC code # is that, Eagle? My understanding is you can use UF in conduit, as long as the conduit is large enough, but it would be a lot easier to go with the THHN/THWN, absolutely.

  • @brad9257
    @brad9257 Рік тому

    I'm surprised you didn't run conduit under the ground too as it would protect the wire with settling rocks. Pretty easy to do.