Aspen Hysys Dynamics- Water Hammer/ pressure surge in pipeline

Поділитися
Вставка
  • Опубліковано 4 січ 2025

КОМЕНТАРІ • 5

  • @davidzhang401
    @davidzhang401 29 днів тому

    Thank you for your sharing

  • @Sk-vk7fr
    @Sk-vk7fr 11 місяців тому

    I kept this calculation on hold as I had no idea how to show water hammer in pipeline.. thanks a tons

  • @FUbaidullahR
    @FUbaidullahR 4 місяці тому

    Thanks for your content sir could u please make a detailed video on it

  • @hanifnajmi4832
    @hanifnajmi4832 5 місяців тому

    HYSYS family is a thermodynamic based simulator where it uses Bernoulli's Equation to solve the hydraulic calculation. However, please note that the momentum factor is not account in both steady-state and dynamic solvers which is important in the hydraulic transient study. The results shown may not reflect the actual pressure surge phenomenon and ultimately, not able to capture the max.pressure/ highest peak during the surge event. That's part of the reason why surge study is preferably carried out on other simulators like PIPENET, AFT, etc instead. Just my honest opinion.

  • @ziaman8808
    @ziaman8808 11 місяців тому

    Hi Rahul, thanks for great video. This enlight me on dynamics of pressure rising. However in my case pressure is not rising when I keep VLV-100 full open and VLV-101 full close. what is the boundary PF-specification? whats the stream has Pressure or flow specification and stream ( understood to be Pressure spec of 49.3 bar). Moreover, could you please advise where may go wrong with my sim. Best Regards.