  • @saradhi56
    @saradhi56 Рік тому

    Just a quick question: I believe both Power per volume and KLa won't be similar at scale up. How do take the next step plz?

    • @MarloesPeeters
      @MarloesPeeters  Рік тому

      kLa is hard to measure but is possible (see other videos). You might want to employ some empirical formula to determine kLa; common equations often depend on vs and Pg/V, thus why Pg/V is often considered to be similar to kLa. Hope this helps