Many more days I didn't understand atx power supply. I was try to practical and didn't find out fault. This video watching very useful. I will be retry . And Inverter AC board your video is very useful Sir I am electronic service mechanic. Thank you Sir.
Very useful and motivated video thanks, please upload live fault finding and how to solve the problem, video Would be more helpful easily understandable. Like a practical experiment...
Desktop ATX smpsla 12v yellow wire and black ground wire touch anathunala smps off akiduchu. Fuse nalla eruku but run agala bro?... Ena check pannanum?
415v input,230v out put, 75VA transformer used in refrigeration control panel, this 75VA is primary side or secondary side? And why this transformer used in it? Please explain sir.
Transformer rated in VA because can take both resistive and inductive load(KW and KVAR). &%VA is apparent power that transformer can withstand. If you give 75VA(Vp x Ip) in primary, you can take 75VA(Vs x Is) in secondary minus losses. For LT control supply , stepdown transformer is provided. No direct 230V supply provided from outside.
நீங்கள் சொல்லி கொடுத்து விதம் மிகவும் நன்றாக இருந்தது 🙏 நன்றி 🙏👍👌
அருமையான தகவல் குருவே உங்கள் ATX POWER SUPPLY பழுது பார்க்கும் முறை யை பார்த்தேன் நானும் அதுபோல் ஒரு SMBS யை சரி செய்து பயனடைந்தேன். நன்றி
Super sir மிகவும் தெளிவான விளக்கம் நன்றி.
It was very helpful, specially block by block explanation.
Super teaching method...
You are best servicing technician.உங்கள் தொண்டு வளரட்டும்...
Super sir the practical example👍and next time to practical project
Many more days I didn't understand atx power supply. I was try to practical and didn't find out fault. This video watching very useful. I will be retry . And Inverter AC board your video is very useful Sir I am electronic service mechanic. Thank you Sir.
Hi sir
Great method of teaching sir. I have a shorted SMPS. I shall try to repair the same using your idea sir. Hope I will be successful.
Simple.and good explanation.very good sir.thank you
Great Explanation sir
Excellent explanation sir.
Rempa rempa useful sir video thank you sir ungalukku
அருமையான. தகல் குருவே
Very good
SMPS ......practical....video testing....,nalla iruku......Sir
Very useful and motivated video thanks, please upload live fault finding and how to solve the problem, video Would be more helpful easily understandable. Like a practical experiment...
Very very useful video, Thanks sir
Very useful video. pls make washing machine circuit falt finding videos
Super sir very explained,
Arumeyaana velakam super sir😃
Thanks. Good explanation.
Use full information
Thank you somuch....keep going......
You are very great👍
Super sir
Very use full information
Sir circuit epdi sir download panriga
Solluga sir
Very usefull thanks 😊
Very nice sir
Soopper video
Excellent sir
Good explanation kind send smps circuit
Super sir thank you sir
வழ்க வளமுடன்
Thank you so much sir ❤
Anna ennoda power supply la 5v mattum varudhu 12v n 3.2v varala switch on pannunadhum fan lite ah mattum move agudhu. Enna pannanum.
very useful sir
Desktop ATX smpsla 12v yellow wire and black ground wire touch anathunala smps off akiduchu. Fuse nalla eruku but run agala bro?... Ena check pannanum?
Hello do you also fix Power Supplies as in service ?
Super
சார் series bulb load கொடுத்து on செய்யும் போது bulbஎரிந்து அனைந்து விடுகிறது. Green wire and black wire short செய்தும் fan ஓடவில்லை. Please reply sir
நன்றி ஐயா
Super sir
Sir please.
automotive any car electric diagram how to c.
Please sir.
Kindly share more smps videos
Please show series bulb connection in service of smps
DVD player erukkura GND TXD RXD 3.3v port yeppadi use panrathunu solluga sir please
Circuit diagram download link mattum send panunga pls.
Sir smps components function review and circuit epadi download pandrathu sir
sir steblize board how to work circut digramoda details soluga
🔥🔥
415v input,230v out put, 75VA transformer used in refrigeration control panel, this 75VA is primary side or secondary side? And why this transformer used in it? Please explain sir.
Transformer rated in VA because can take both resistive and inductive load(KW and KVAR). &%VA is apparent power that transformer can withstand. If you give 75VA(Vp x Ip) in primary, you can take 75VA(Vs x Is) in secondary minus losses.
For LT control supply , stepdown transformer is provided. No direct 230V supply provided from outside.
Treadmill circuit board video podunga sir
Sir how to disable smps power suply over load production
Bleeder resistance 100v 10000MFD discharge resistance velue ????
Bulb watts? Sir 🙏🏻
Thank U Sir
சர்க்யூட் PDF upload பண்ணுங்க சார்
🙏
How to download circuit diagram please help sir 🙏🏻
SMPS HP Model No PC7036 auto coupler three pin control video
🙏 ஐயா, +volt, -volt என்றால் என்ன?
In dual power supply, +12v ,0v and -12v will be there. It is used in power amplifier circuits like OP amplifiers.
Sir please class
Endha circuit PDF kidaikuma?
Super
🔥🔥
THANK U SIR