Making $1,600/hr. As An Electrician?

Поділитися
Вставка
  • Опубліковано 10 вер 2024

КОМЕНТАРІ • 90

  • @munsters2
    @munsters2 2 роки тому +10

    The problem with remodeling/repair jobs is you never know what to expect. It could be a 30 minute job or it could be a 6-8 hour job depending upon what is behind the walls. Unless you arrive with a big truckload of tools and supplies, you may have to make several trips to obtain more parts or tools.

  • @wkbillweston
    @wkbillweston Рік тому +10

    GFCI doesn't require a ground. That is what the sticker is for. GFCI works on the imbalance between hot and neutral.

    • @shubinternet
      @shubinternet 11 місяців тому

      GFCI stands for Ground Fault Circuit Interruptor. Hence, the need for a good path to ground.

    • @Normbee
      @Normbee 10 місяців тому +5

      ​@shubinternet ,you can install a GFCI receptacle with no ground. If a homeowner has a 2 prong Receptacle and wants a 3 prong and doesn't want to pay to run a ground to it... then you can install a gfci with The no equipment ground sticker on it. NEC 2020 406.4 (D)(2)

  • @TheElectricalNut
    @TheElectricalNut Рік тому +3

    If you're putting an outlet in a metal box especially one as tight fitting as that then it's a good idea to put a bit of electrical tape around the outlet.

  • @carlcapello9956
    @carlcapello9956 Рік тому +3

    After watching you do the electricians job I have no love to be an electrician. I will pass on being an electrician and I will continue to look for another way to make a living. Thanks for you great videos, I enjoyed watching them and discovered being an electrician is no joke but, serious hard labor.

  • @brianharmeson3144
    @brianharmeson3144 2 роки тому +9

    GFCI does not require a ground. You're fine without it. It looks to be an ungrounded system anyway. Most likely, all 3 prong receptacles in that home should be GFCI protected because there are no ground wires to any of them. That means more work/money for you.

    • @johnsandlinjr
      @johnsandlinjr 2 роки тому +3

      As long as you mark it no equipment ground. Right?

    • @brianharmeson3144
      @brianharmeson3144 2 роки тому +1

      @@johnsandlinjr Yep, and "GFCI protected".

    • @johnsandlinjr
      @johnsandlinjr 2 роки тому

      @@brianharmeson3144 which I always find funny when it’s over the gfci lol

    • @brianharmeson3144
      @brianharmeson3144 2 роки тому

      @@johnsandlinjr I've seen that happen too. Obviously, a receptacle that is "GFCI protected" can be any receptacle on the load side of the GFCI. Of course, the "GFCI protected" stickers are only required on standard devices, not actual GFCI receptacles.

    • @frankierocca8127
      @frankierocca8127 Рік тому

      It was a self grounding gfi anyway.

  • @JohnThomas-lq5qp
    @JohnThomas-lq5qp 2 роки тому +3

    Stopped doing work for all realtors. In my area they would take at least 4 months to pay then if an old house had trouble during that time would try to blame you for it and want a free repair.

  • @samsen3965
    @samsen3965 2 роки тому +4

    Excellent and please do add a final paragraph talk to all your clips like this or as to a rough estimate of what the kind of work showed might cost the landowner. This makes your clips a lot more realistic and financially valuable. In short, a priceless piece of information that no one may otherwise find on UA-cam, thus elevating your channel even more.
    Anyways and thanks a lot for your valuable knowledge shared here.

  • @russrockino-rr0864
    @russrockino-rr0864 2 роки тому +11

    Maybe $1600 a day, not per hour. Electrician has to locate house, get tools and materials out of van, greet customer, possibly move stuff out of the way, lay down drop cloth or towel, do the actual job, sweep and or vacuum up the mess, move stuff back, explain what was done to the customer, collect payment from the customer, collect your tools and maybe a ladder, put them back on the truck or van and move on to the next job. Those things add a lot more time to your 7.5 mins. And, do you really only want to do things to code minimum I think your math is very flawed, Joel. And that job you just did is a callback waiting to happen. Thanks, Russ from Oregon-27 years in the Trade.

  • @JasonWester
    @JasonWester 2 роки тому +4

    How did the interview with Ronald go on Saturday?
    Kidding aside, you rock.

  • @michaeljavert4635
    @michaeljavert4635 Рік тому +2

    I tape the receptacle when there is bare copper grounds. It does short sometimes when not tapped. I've seen it happen, it's happened to me. Not with any work I've done myself, but work someone else did after they were gone. It only takes an extra 30 seconds and can't be too safe even if it's not necessary. It can't hurt.

  • @estevaness
    @estevaness 2 роки тому +1

    This is true, get a few calls from realtors to update to GFCI’s and or the dreaded aluminum wiring in older homes.. good vid 👍

  • @alonzomartii
    @alonzomartii 2 роки тому +2

    I replace 2 of them and I got $100 plus my beers lol

    • @Blackdynasty123
      @Blackdynasty123 Рік тому

      That sounds more reasonable they only take 5 min to replace so two receptacles for hundred bucks and some beer sounds good

  • @MA-wb1xo
    @MA-wb1xo 27 днів тому

    We use impact drills to remove the device from the boxes. That’s too much screwdriver turning 😂

  • @brianharmeson3144
    @brianharmeson3144 2 роки тому +2

    Good thing the tile guy cut the hole big enough for the gfci to fit. That's no fun when you have to drag out the diamond blade and grinder.

  • @mikeheller1225
    @mikeheller1225 6 місяців тому

    I like to add pigtails to a box like this, and just have one set of conductors coming to the device.

  • @Sebanisu
    @Sebanisu 7 місяців тому

    I do alittle bit of DIY around the house. I just learn some of this over time. The builders grade light switches seem to be the worst. I've had so many of those fail. Where terminals on the side that hold the wires just break off, or the back of the switch is broken in half.

  • @johnkulpowich5260
    @johnkulpowich5260 Рік тому

    I agree. First hour $225. Covers your truck next hour your hourly rate

  • @bahbarino4479
    @bahbarino4479 2 роки тому +2

    Pigtailed! a must. Yoke straight!

  • @djaliendenis
    @djaliendenis 2 роки тому +1

    What do you mean by service fee you are ready change your hours ???
    Maybe I missed something

  • @markcarson8566
    @markcarson8566 2 роки тому +1

    My grandad always said, if a bullfrog had wings he would not bump his ass when he landed.

  • @williamdawson6351
    @williamdawson6351 2 роки тому +1

    drill and tap the box the screws are not always good ground I know people use to use the screws as ground but times have changed.

  • @alyssaisaackson6797
    @alyssaisaackson6797 Рік тому

    Joel you need a Dewalt Electric screw driver that really speeds it up

  • @randyfitz8310
    @randyfitz8310 8 місяців тому

    I find the Klein wobble screwdrivers speed my work by about 25%, consider using them.

  • @brianasgarali4355
    @brianasgarali4355 2 роки тому +2

    Good job. Have you considered the use of a drill driver to back out and carefully drive in screws for some speed ?

  • @jerrypruden887
    @jerrypruden887 2 роки тому +1

    I always install bottom screw first

  • @nil2k
    @nil2k Рік тому

    You should look up a Klein Tools 67100, it'll make jobs like these go a lot faster. You're the first electrician I've seen who doesn't use one.

    • @ElectricProAcademy
      @ElectricProAcademy  Рік тому

      Thanks for the rec. I'm not much of a tool enthusiast so UA-cam has been wonderful for upping my game!

  • @shubinternet
    @shubinternet 11 місяців тому

    So, wait -- are those cables covered by fabric? Is this from knob-and-tube wiring?

  • @jenko701
    @jenko701 2 роки тому +2

    A fast nickel is better than a slow dime all day long.

  • @goings3604
    @goings3604 Рік тому +2

    As explained you will do 7 of these for 175 labor
    I do these for $45 laborx7=$315 an hour not even close to $1600

  • @kirkjackson7096
    @kirkjackson7096 8 місяців тому

    How did you get the plate on? The tile looked like it was behind the screws for the plate.

  • @james25980
    @james25980 9 місяців тому

    why were both wires put in on line side im curious?

  • @DanBurgaud
    @DanBurgaud 2 роки тому

    these tiny jobs are so underrated.
    One of my neighbor's toddler lost a thumb because of no GFCI socket.

  • @patrickjholguin4447
    @patrickjholguin4447 2 роки тому +4

    You could have left the old receptacle in and used a GFCI Breaker.

  • @DougLockard
    @DougLockard Рік тому

    Did you really down steam those conductor..not knowing where they go...it's in a bath

  • @awood965
    @awood965 Місяць тому

    Tape and to use impact to tap and pigtail would have took approximately 1 minute. Just me though guess thats 8 minutes if i do 8 jobs a day

  • @JohnThomas-lq5qp
    @JohnThomas-lq5qp 2 роки тому +2

    Where's the torque driver required by NEC to secure ALL terminals, screws, & bolts ?

  • @TheSleepyCraftsman
    @TheSleepyCraftsman Рік тому

    How did your discussion with Ronald go?

  • @kgt9535
    @kgt9535 2 роки тому +3

    Yes sir. It's all about work volume, (potential) consequential referrals and repeat/loyal customers/clients.
    I'd settle for 1% of a billion over 1% of one thousand any day....high, reasonable work volume is king; just don't take on more than you can professionally deliver on. Pace yourself wisely and scale up as you go where needed. Reputation is EVERYTHING in service work, especially if you operate in a competitive market, which lends to staying on top of trends and high demands. It's ALL a process. Keep the fire in the wire 👍

  • @BigJohnson1566
    @BigJohnson1566 Рік тому

    Good intel 👍

  • @shshshs2
    @shshshs2 2 роки тому +1

    With technology is advancing why any company can’t make those GCFI receptacles smaller?

    • @donl1410
      @donl1410 2 роки тому

      @@ElectricProAcademy Leviton GFCI's are definitely shallower than competitors and are the brand I use. Your link points to Leviton, but you're installing a Lutron...The link also shows a 20 amp device, witch could be misleading for DIY'ers. Alright Leviton haters, lets hear from you.

    • @epia125
      @epia125 2 роки тому

      Leviton offers a slim GFCI receptacle.

  • @tuck6464
    @tuck6464 Рік тому +1

    This is a misleading video. More like $1600 / day, if your being honest.

  • @tylerwilliams3868
    @tylerwilliams3868 Рік тому

    im so confused ive always been told the slide in connection to and outlet was a huge no go? like you should always hoop your leads. am i missing somthing?

    • @ElectricProAcademy
      @ElectricProAcademy  Рік тому +1

      True true, we know exactly what you mean! The difference here is that GFCIs are not actually "backstabs", they just have covered, screw-in terminals. Basic receptacles, on the other hand, have a tension system that is not as reliable as a hooked and screw-tightened connection

    • @tylerwilliams3868
      @tylerwilliams3868 Рік тому

      @@ElectricProAcademy thank you for clearing this up for me!

  • @AmericanWireman
    @AmericanWireman 2 роки тому +2

    I'm a union journeyman electrician , and I've always played around with the thought of starting my own electrical service company doing things like this,
    Btw, use a small handheld drill instead of your screw driver lol

    • @AmericanWireman
      @AmericanWireman 2 роки тому

      @@ElectricProAcademy I actually live In Muncie, but I am In the IBEW, it would be frowned upon if I worked for a non union company.

  • @adrian_cool_kid2853
    @adrian_cool_kid2853 6 місяців тому

    1600 an hour what do you mean do u mean 1600 a week

  • @travalicious128
    @travalicious128 Рік тому

    Yessir I know all this and I'm a green light apprentice :) Would it not be a better ground path attaching a piece of ground to the ground screw in the back of the box instead of the actual screws used to mount outlet? Interesting...

    • @ElectricProAcademy
      @ElectricProAcademy  Рік тому +1

      This particular (old) box did not have a tapped hole for a ground screw, which is why I had my inner dialogue at 4:05 😅. Whenever possible, the dedicated ground is better, we just didn't have that option here.

    • @travalicious128
      @travalicious128 Рік тому

      @@ElectricProAcademy Got you. Thanks for the input!

  • @priceandpride
    @priceandpride Рік тому

    Even though it only took you 7 minutes do the techs take the full hour to make the home owner feel like they are getting their moneys worth?

    • @ksehzi
      @ksehzi Рік тому

      You charge for 1 hour, usually first hour is higher priced to cover cost of the trip. Home owners would rather you be in and out then standing around or sitting in the van. You could always tighten connections at the panel but if you touch it then you're liable. 1600/he would require rapid turnover. I think.

  • @persona250
    @persona250 Рік тому

    that cabling looks 70 years old ....

  • @DjGho5t1
    @DjGho5t1 2 роки тому +1

    How did you get the ground in?

    • @MannyAguilarJr
      @MannyAguilarJr 2 роки тому +1

      It's probably a grounded metal box which grounds the GFCI when it's screwed on. if not then there should be a sticker placed on the face plate "no equipment ground", stickers should be in the receptacle packaging. He could've also drilled and tapped the metal box to add a grounding pigtail and screw instead of relying on contact of the screws and yoke like my first answer. But he used the first method I mentioned.

    • @brianharmeson3144
      @brianharmeson3144 2 роки тому +1

      It's not required. There probably isn't a ground anyway by the looks of the cloth covered conductors.

    • @frontman4u243
      @frontman4u243 2 роки тому

      Correct, Brian Harmeson. BX is not observed by the code and does not offer a low impedance, effective ground-fault current path.

    • @brianharmeson3144
      @brianharmeson3144 2 роки тому

      @@frontman4u243 I met one of your employees a couple weeks ago (parts runner) at the supply house (KR). Really nice kid. I told him how much I enjoy your videos.

    • @donl1410
      @donl1410 2 роки тому +1

      @@ElectricProAcademy Pre 1960 BX is type AC cable and is recognized. The armor clad is grandfathered as an EGC, but does not meet current standards, and when possible should be replaced. Your tester indicated correct, so it's either being grounded by the AC cable armor (if that is the system) or by external individual EGC on the back of the metal boxes. Either way a better alternative is using a self grounding GFCI, (Leviton) readily available in my location.

  • @MrShack246
    @MrShack246 Рік тому

    Ronald would have done it in 4.

  • @homerwinslow9047
    @homerwinslow9047 2 роки тому +1

    You put both the line in the load on the same terminal. Big mistake. Go back to school

    • @thorasguardselectrician2013
      @thorasguardselectrician2013 2 роки тому +1

      Depends if the rest of the circuit needs to be GFCI protected or not. Video didn't show what else was on that circuit.

    • @1patrickx
      @1patrickx 2 роки тому +5

      How do you know the second circuit was meant to be load. Quite often you will need to put line in and line out on the line terminal. You only use the load, if you have a down stream circuit that needs to be ground fault protected by this receptacle. Go get a refund from your school and learn real life application..

  • @JohnGorman355
    @JohnGorman355 2 роки тому

    Haste makes waste!

  • @networkedperson
    @networkedperson 2 роки тому

    why do you use links to promote a company that is famous for fighting worker rights and undermining human rights? How does that align with your "values"?

    • @fusion772
      @fusion772 2 роки тому +1

      What company are you referring to?

    • @stans5270
      @stans5270 2 роки тому

      Try that with ignorant people.
      Tell your WORKERS that they aren't slaves.
      They can go and work for someone else ANYTIME.
      GOOH with that BS.
      QUIT and work somewhere else. It's people like YOU that caused the AUTO industry to need a taxpayer buyout from the government.

    • @thorasguardselectrician2013
      @thorasguardselectrician2013 2 роки тому

      @@fusion772 that's what I was thinking 🤔

    • @networkedperson
      @networkedperson 2 роки тому +1

      @@fusion772 you seriously can't figure it out?

    • @fusion772
      @fusion772 2 роки тому

      @@networkedperson You're insufferable

  • @markcarson8566
    @markcarson8566 2 роки тому

    You are not a master, a dumb apprentice maybe, you are not with in the NEC

    • @JasonWester
      @JasonWester 2 роки тому

      @@ElectricProAcademy You are a terminally optimistic person. Very refreshing.