(R-05). Define Load Patterns , Diaphragms , Mass Sources ; Residential Building Design - ETABS

Поділитися
Вставка
  • Опубліковано 18 січ 2025

КОМЕНТАРІ • 19

  • @dilipngangom4198
    @dilipngangom4198 4 роки тому +1

    Why dont you model the beam supporting the landing slabs?

  • @abdulzahiraliyi8675
    @abdulzahiraliyi8675 4 роки тому +3

    1. when and why do we need to assign different diaphragm for different floors?
    2.we don't have shell element on the ground floor except rising stair and yet you assigned diaphragm, can you elaborate me about please.
    3. while defining mass source, doesn't the program consider additional load if we check only "specified load pattern"
    THANKS

    • @ehsantutorials5020
      @ehsantutorials5020  4 роки тому +2

      dear Abdulzahir.
      to check the eccentricity we need the center of rigidity and that obtains when define diaphragm, that is why I have defined diaphragm in ground floor.

    • @ehsantutorials5020
      @ehsantutorials5020  4 роки тому +1

      No the program does not consider additional loads.

    • @abdulzahiraliyi8675
      @abdulzahiraliyi8675 4 роки тому +2

      @@ehsantutorials5020 what about the purpose or advantage of assigning different diaphragm for each floor rather than assigning a single D for all floors

    • @Engrwaleed555
      @Engrwaleed555 4 роки тому

      @@abdulzahiraliyi8675 Some designers just select all the frame members (Ctrl+All) of all the stories and apply single diaphram. But I don't know when method is correct.

  • @amitdey9925
    @amitdey9925 3 роки тому

    Amazing video keep it up 👍🏻

  • @Engrwaleed555
    @Engrwaleed555 4 роки тому

    Ctrl+All and apply D1 to all of the frame. This way sloping stairs will also come into diaphram. Kya aisa theak rahe ga?

  • @mathstube1802
    @mathstube1802 4 роки тому

    can you share how to add pitch roof ( wooden truss/ steel tube truss with CGI sheet covering) loads on structure??

  • @akshaydudhane5451
    @akshaydudhane5451 4 роки тому

    why you are not assigned the IS code for sesmic & wind load ?

  • @sajidahmedsyed3256
    @sajidahmedsyed3256 4 роки тому

    U r the best

  • @c.krubhashree2074
    @c.krubhashree2074 4 роки тому

    Sir can u make video of full autocad detailing of structural members of this residential building

    • @ehsantutorials5020
      @ehsantutorials5020  4 роки тому +2

      I will make a video about detailing in of structural members in Autocad

    • @c.krubhashree2074
      @c.krubhashree2074 4 роки тому

      @@ehsantutorials5020 Sir do make it as detailed series with sp 34 guidelines explanation with audio in ur voice so that we can understand detailing of all the structural members of this same residential building

  • @shameerak787
    @shameerak787 4 роки тому

    How could get trial version of tgis software

  • @positivevibes4265
    @positivevibes4265 4 роки тому

    Why no speech, only music?. If some explanation was given it will be better for etabs beginners sir.