This is not a fact that the fuse was open there is a reason behind that, this video doesn't totally show true. As per my experience if this fuse opens near the capacitor, you should always get another defective material in the inverter, fuse only reacts as open may be any supply of IGBT gate terminal or DC terminals shorted. If you change only the fuse, the new fuse will blow again.
There are several reasons that fuse will get blow.... It's a basic thing that every Engineer will check the near by things properly before replacing the fuse. After replacing ,..the fuse was not blown it was working fine and till now there is no issue.
Romba nalla iruku... Good informative video👍👍 keep doing the same
Very Informative video keep sharing knowledge glad to see you❤
Very simple & useful.. Please post how to repair Inverter too.
Ok soon
it is good. May God bless you.
Must USE Proper PPE
Noted
Control PENAL, then you know that you are dealing with professionals ;D
May be that was a technical term my colleague used to say
Excellent bro. Good information
Thanks brother💓😊😊😊keep supporting and Share it to other biomeds also which will be usefull for them
Informative 👍 Good 🔥🔥
Thanks brooo
The background music is more deadly than HV capacitors.
😮oh okk
test lamp connect in series to discharge battery how you make that pls ❤
please share your contact details I will explain you
Good🔥
Thanks bro💓
Super sir 👍
Thank you sir,,,Keep supporting
Good Brother
Thanks bro😊😊
Useful. thanks
Glad it was helpful!
good
Thanks brother...keep supporting💓💓💓
Nice
Thanks bro
Machine is giving 2 and 4 no fault on s-19 intermittently so what could be the reason for fault kindly suggest
biomedicaldiaries@gmail.com pls mail me the issue in brief
Is there 19 pulse board in dental xray
No bro dental xray is different
Hello sir I have a problem with Siemens mobilett xp Eco 2015
Error 6 & 13, did you can help me plaz?
Please mail me at biomedicaldiaries@gmail.com
Can you tell me how to do troubleshooting in Allengers Mars 3.5
Is it u are facing issue
possibility depends on , which fault led is glowing..............
Yes bro,Forget to mention
How to contact you brw about biomedical repair in hospital i have some doubt??
Pls contact 9629429028
Mujhe bhi sikna hai repering sir
Sir mere pas yz100 machine hen ur wo xpuse mian msla kar rahen hen jesy xpuse karte hen tu pechen jah rele wali jaga sy sparking hojati hen
Hi, can u pls tell me in English, i can understand Hindi little bit
@@BiomedicalDiaries whatsap number send m plz
This is not a fact that the fuse was open there is a reason behind that, this video doesn't totally show true. As per my experience if this fuse opens near the capacitor, you should always get another defective material in the inverter, fuse only reacts as open may be any supply of IGBT gate terminal or DC terminals shorted. If you change only the fuse, the new fuse will blow again.
There are several reasons that fuse will get blow....
It's a basic thing that every Engineer will check the near by things properly before replacing the fuse.
After replacing ,..the fuse was not blown it was working fine and till now there is no issue.
I have got a generator problem on canon Mobile x-ray machine.
How can I contact you?
I dont have the service manual for that brother
Hello Rakib Hussain,Biomedical engineer,I have problem with c arm.... Could you please help me with your contact so that I can explain
biomedicaldiaries@gmail.com
Service mannual
I don't have the service manual
Hwo to fix network 24000 error
can you share me the equipment make and model details?
ভিডিও তে মিউজিক না দিলে ভাল হয়
Pls type in English