Looks like an issue with voltage spikes from the buzzer, probably doesn't have sufficient capacitors or diode spike suppression. My KSGER works fine even with the buzzer, but it is hardware version 2.1S so I guess they fixed it.
Hi. I have a T12 BC3 tip (Hakko technology, a clone), I checked the ohms it's not OL but the workstation reboots when I use this tip (it's new. The soldering workstation is a T12 from KSGER). Any way to repair this tip? Thank you. God bless, Rev. 21:4
I had this issue randomly in the past.. without any action this issue is no longer present. Maybe I have changed the AC connection by 180 degree (but I'm not sure about this).
Looks like an issue with voltage spikes from the buzzer, probably doesn't have sufficient capacitors or diode spike suppression. My KSGER works fine even with the buzzer, but it is hardware version 2.1S so I guess they fixed it.
You're probably right. Or can it just be a software bug in the firmware?
Hi. I have a T12 BC3 tip (Hakko technology, a clone), I checked the ohms it's not OL but the workstation reboots when I use this tip (it's new. The soldering workstation is a T12 from KSGER). Any way to repair this tip?
Thank you. God bless, Rev. 21:4
I had this issue randomly in the past.. without any action this issue is no longer present. Maybe I have changed the AC connection by 180 degree (but I'm not sure about this).