  • @bjleau76
    @bjleau76 2 роки тому +3

    Great video, was extremely helpful especially the explanation of the jumper on a Hayward pool heater, Thank you

  • @vincentmeo6280
    @vincentmeo6280 2 роки тому

    What a great video now I know For 21 years I was a plumber

  • @michaelleddy3701
    @michaelleddy3701 2 роки тому +1

    Ayeee a new joisey guy .

  • @wallydesouza1
    @wallydesouza1 Рік тому

    I have a outlet from out pool heater. Pool straight out of the panel. 15 amp. Will it power this same unit ?

  • @richdevito78
    @richdevito78 Рік тому

    What would happen if u did not switch module from 240/120 or vice versa?

  • @williameisenberg1999
    @williameisenberg1999 Рік тому +2

    Hi Ron , Thanks for the video ? What kind of linesman pliers are you using can you give me the brand name . They look really nice to work with … Thanks Again Eisenberg Electric. Simsbury ,Ct.

    • @electricalron
      @electricalron  Рік тому

      Hello, these are Klein Hybrid pliers. They have built-in crimper and strippers. My favorite lineman’s pliers ever.

    • @williameisenberg1999
      @williameisenberg1999 Рік тому +1

      Thank you ,, Just ordered one !!

  • @vince6829
    @vince6829 Рік тому

    Thank you.

  • @jimamentas7190
    @jimamentas7190 3 місяці тому

    Can you use regular 12/2 with ground to connect inside heater?

    • @electricalron
      @electricalron  3 місяці тому

      if the units outside no.

    • @jimamentas7190
      @jimamentas7190 3 місяці тому

      @@electricalron could you explain why not? Just curious

  • @Inmate533
    @Inmate533 2 роки тому

    How does the heater know when the pump is running? Does the heater have a flow switch that only allows the heater to turn when the water is running through it? Sorry if this is a dumb question.

    • @electricalron
      @electricalron  2 роки тому +1

      Not a dumb question. I imagine through a set of contacts in the filter. Definitely wiring within the appliance.

    • @SqueakyHinge
      @SqueakyHinge Рік тому +1

      The heater has a pressure switch on the inlet of the piping system which will close the control circuit if that pressure sensor senses pressure - from the pump running - so the heater will run.

  • @kidR0BOT
    @kidR0BOT Рік тому +1

    Pssstttt next time wire it on the load side of the time clock that controls the filter pump. No extra breaker needed and the heat won’t run unless water is flowing.

  • @SqueakyHinge
    @SqueakyHinge Рік тому

    Why don't you have a bond on the heater? Is it because the heater is far away from the pool/pumps?

  • @markgeyer1
    @markgeyer1 Рік тому

    What AMP was the beaker (15/20)?

  • @booSackk
    @booSackk 2 роки тому

    Do you have to pull permits for every single one of ur jobs
    Can you list some examples where you dont pull permit

    • @electricalron
      @electricalron  2 роки тому

      Repairs & maintenance and I do a lot of that. Permits for any new wiring but not for changing out light fixtures or changing GFCI’s.

    • @booSackk
      @booSackk 2 роки тому

      @@electricalron thanks for replying, i almost have my masters and am looking forward to start my journey in vancouver area, always curious about the permits and doing it right. One of the jobs u had, installing light fixtures in garage with piping and motion sensor, did you need permit for that?
      Or shed wiring
      Thanks!

    • @electricalron
      @electricalron  2 роки тому

      @@booSackk Best to check with building department. It’s Canada so I’m sure it’s not the same as here.

  • @markmenner6922
    @markmenner6922 2 роки тому

    Hi Ron, on outdoor outlets for a deck does NJ code require gfci outlets and gfci breakers or is a gfci breaker with wr outlets ok.

    • @electricalron
      @electricalron  2 роки тому +2

      A circuit breaker or outlet is acceptable because it's only required to be GFCI-protected. I will tell you the outlet will be cheaper than the circuit breaker. The outlet MUST BE 'WR' which means weather-resistant.

    • @markmenner6922
      @markmenner6922 2 роки тому

      Thanks Ron

  • @wallydesouza1
    @wallydesouza1 Рік тому

    Does that pool heater have to be hard wired ?

    • @electricalron
      @electricalron  Рік тому

      No, you could attach a cord to it and plug it in I suppose.

    • @wallydesouza1
      @wallydesouza1 Рік тому

      @@electricalron like a dishwasher power cord I’m thinking. I’m just wondering if 15 amp dedicated is enough for this 400k btu gas pool heater

  • @Dr.Colone_Ucantmakethisshitup

    Rwplaving a hayward heater

  • @daviddillard8206
    @daviddillard8206 Рік тому

    Where was your sensor wire? All Hayward heaters have one.

    • @electricalron
      @electricalron  Рік тому

      Sensor for what?

    • @SqueakyHinge
      @SqueakyHinge Рік тому

      The pool water sensor as well as the pump pressure sensor and the control thermostat are all located inside of the heater. There can be options of a remote sensor control.

  • @moo-r8199
    @moo-r8199 6 місяців тому

    I dont fish the wire i just push in it with soap it faster

  • @mackfisher4487
    @mackfisher4487 Рік тому

    Why is it that some trades running their class-II wiring with no concept of dressing wires in a workmanship manner. I'm always surprised when I see HVAC equipment wired neatly some folks seem to like spaghetti.

    • @electricalron
      @electricalron  Рік тому +1

      Some just don’t care about themselves so naturally they don’t care about their work.