Oil Burner maintenance - setting electrodes and replacing nozzle

Поділитися
Вставка
  • Опубліковано 12 січ 2014
  • This video shows you how to adjust the electodes in an oil burner and how to replace an oil nozzle.
  • Навчання та стиль

КОМЕНТАРІ • 212

  • @andrewlennox8047
    @andrewlennox8047 4 місяці тому +2

    Just wanted to say thank you. It's 930pm here and cold as heck. Furnace has been running like crap and finally stopped working altogether. Your video helped me get my igniter set and cleaned the nozzle and it's back running good.

  • @greglaggassey5151
    @greglaggassey5151 7 місяців тому +2

    I like your style of making a video .your calm.... you don't add a bunch of unnecessary information direct and to the point very professional thank you

  • @aloveforsaken
    @aloveforsaken Рік тому +3

    You saved my oil furnace bro, my gaps were completely off to the point that my furnace was stalling and also puffing out black nauseating smoke. With this my furnace is running like the 50yr old champ it once was. ❤

  • @beatfarmerfan
    @beatfarmerfan 7 місяців тому +2

    Back in the 70’s I was in the Air Force in northern Maine and worked in the
    heat shop.
    Everything was oil fired back then, boilers and warm air.
    We spent most of the summers cleaning and PM’ ing.
    The heating system for the base grade school and a few other bigger
    buildings used a big rotary type main burner, with a .75 gph gun type burner as a pilot.
    I think it was about 1990 before the Bunker C smell left my body.😄
    Your oil burner videos bring back good memories.

  • @kertrowlins3954
    @kertrowlins3954 2 роки тому +4

    Can u believe that you made this video 8yrs ago & you just helped me out BIG TIME! 1/8", 1/8", &1/2" now I'll never forget it Thank you...now if I can just figure out y my Beckett oil pump keeps stopping or flowing? Oil pump is only 1yr old & furnace shut off so I figured I'd just make sure it's getting oil & it does come out of the bleeder valve for a few seconds then nothing? I'll let it sit for a few minutes & again it acts like it's going to give me a good flow but then flow completely just fades away? But hay I'll figure it out.

    • @CookingWithXpsZero
      @CookingWithXpsZero 7 місяців тому +1

      Have you changed your inline oil filter recently?

    • @Gunma_garage
      @Gunma_garage 6 місяців тому

      My filter was so rusty and clogged. Chedk it out!

    • @tobysarsi6864
      @tobysarsi6864 5 місяців тому

      @@Gunma_garage I had the original style felt filter with the metal mesh center cylinder and when I replaced it, I also noticed it had rust particles and chunks due to contact with stray water in the heating oil which was bound to happen in a 40+ yr tank. So I switched to the newer style white fiber filter which fit perfectly and has no metal parts that will rust.

    • @FckYT-my5wz
      @FckYT-my5wz 5 місяців тому

      @@tobysarsi6864did you check the strainer inside the end of the pump housing?
      If you had large rust particles that strainer likely needs cleaned also

    • @alangray4617
      @alangray4617 4 місяці тому

      How do we get to the pressure relief part of the pump

  • @frankcastle5294
    @frankcastle5294 Рік тому +2

    Thanks a ton Keith and your instructional vids are always the best. Wanted to replace and set the electrodes on my old Beckett oil gun and this vid was exactly what I needed. Thanks again.

  • @lee18103
    @lee18103 8 років тому +8

    DUDE!!! Thank you, my bullet heater was miss adjusted(used equipment). I used a 1/8 drill bit as a gauge. Thank you again.

    • @jeffhermida4788
      @jeffhermida4788 3 роки тому +1

      using drill bit as as a gauge is genius!!!

  • @BlueSwallowAircraft
    @BlueSwallowAircraft 5 років тому

    Thanks for a very profession description of these setting and the use of the T501 Gauge.

  • @chevellesbc
    @chevellesbc 8 років тому +1

    very thorough video I followed it and it worked like a charm

  • @bongo7654
    @bongo7654 5 років тому +1

    Getting ready for winter ,great video ,thanks for posting

  • @dave0028
    @dave0028 10 років тому +1

    Great video explanation of how to set the electrodes.

  • @Lowzone73
    @Lowzone73 9 років тому

    my Beckett settings were a lot further apart and further away. as you said, some vary, just mine were almost twice those settings as my nozzle is a .85 and 80 degree which may require a greater gap. GREAT video informing about the location above the nozzle. subscribed!!

  • @henrypauley4877
    @henrypauley4877 3 роки тому

    You saved me I had no idea how they had to be adjusted and it worked thanks so much sir

  • @bigpardner
    @bigpardner 8 років тому +3

    Thank you. It would be nice to see removing and replacing the assembly

  • @ianjuby
    @ianjuby 4 роки тому +2

    Just to let youse know, not only was this video highly informative and educational, it was the reason I ordered parts from youse guys and not the competitors. :)

  • @cthulhu472
    @cthulhu472 7 років тому +8

    I was just recently hired by Beckett Corp as an assembler nanda this video has really helped me understand the measurements of the electrode to nozzle ratio better and how to put the burner toghether properly thank you and wish me luck sir.

    • @diastoleny
      @diastoleny 2 роки тому +2

      So how's the new job 5 years later?

    • @Skrub
      @Skrub 9 місяців тому

      @@diastoleny6 years…think he’s still got it?

  • @rodgraff1782
    @rodgraff1782 5 років тому +12

    Good video. I wish people would pay more attention to servicing the electrodes. We replaced them on every annual service, as I have seen a lot of bad delayed ignitions from electrodes that looked good but had hair line crack or pits in the porcelain that shorted the spark to ground intermittently.

  • @want2no2
    @want2no2 9 років тому +1

    Great Video, was having problems for over a month and wasn't sure how to set the electrodes. My Burner is working just fine now. Thanks for the video!!!

    • @99quintinsnapshot
      @99quintinsnapshot 8 років тому

      +want2no2 You finally got off your damn ass and fix your burner.

    • @_BigTimer85
      @_BigTimer85 2 роки тому

      @@99quintinsnapshot Been seeing quite a few of these comments from you. STFU

  • @treysmith7206
    @treysmith7206 6 років тому

    Followed your measurement for the gaps, she's running and purring like a kitten. Thanks!!!

  • @dj-specializedmixes2157
    @dj-specializedmixes2157 8 років тому +2

    thank you so much! This vid helped a lot!!! very appreciated

  • @MegaCyberleader
    @MegaCyberleader 2 роки тому +3

    YA KNOW YOU SAVED ME 3GRAND SHOWING ME HOW TO FIX THAT. tHANKS sorry for the caps I was excited.

    • @markw2266
      @markw2266 Рік тому

      I love the positively in the comments section. Yours was a winner. Not everything on UA-cam is fantastic advice but this one seems pretty good.

  • @topcatceo
    @topcatceo 8 років тому +11

    Awesome video very clear, very thorough, leaving nothing to guess. Awesome !!!!! :)

  • @hediewiebe2128
    @hediewiebe2128 2 роки тому

    i appreciate the concise information and very good demonstration.

  • @Templar777_K9
    @Templar777_K9 2 роки тому

    Very informative. This video makes a good refresher of my heating course at NEIT ( NEW ENGLAND INSTITUTE OF TECHNOLOGY).

  • @joxtv5538
    @joxtv5538 Рік тому

    Watching, beautiful oil burner electrodes invention, thanks for sharing

  • @simonmarakalu66
    @simonmarakalu66 10 років тому +6

    Thanks for explanation I like it.

  • @hatchman3708
    @hatchman3708 6 років тому

    Thanks, I had mine adjusted to far forward, burnin the tips of the electrodes

  • @breakingfree7869
    @breakingfree7869 3 роки тому +1

    Thank you for this easy to understand video. I didn't want to take a course in HVAC like other videos. I had new parts, just wanted to know how to set the electrodes and your video got my furnace going again. Thanks again Sir.

    • @rollzolo
      @rollzolo 2 роки тому +1

      We can take UA-cam university..learning alot staying home. Just no roofing. Stay safe

    • @CL-ty6wp
      @CL-ty6wp 2 роки тому

      @@rollzolo My oll man lost his best friend to falling off the roof. Heights and electricity I have much respect for.

  • @Ratman_Bejo
    @Ratman_Bejo 3 роки тому

    how are you, sir, my name is Mr Ratman from PT Indira Dwi Mitra, one of the suppliers of the riello brand oil gas burner located in Indonesia,
    and thank you for the info on the repair of nozzle oil for the riello burner, always greet you with success

  • @pauleohl
    @pauleohl 10 років тому +3

    You were helpful. I saw that your new electrodes have points ground on the ends. Mine were burnt off. I ground new points with a conical mounted stone in the drill press. A block of wood with a 3/32 hole drilled horizontally guided the electrode as the stone ground the point. The electrodes had to be bent because they were now too short.
    It all worked out fine. Thanks for the video.

    • @99quintinsnapshot
      @99quintinsnapshot 8 років тому +1

      +Paul Ohlstein You finally got off your damn ass and fix your burner.

    • @LibertyDIY
      @LibertyDIY 7 років тому

      Good info. I recently bought a new burner tube that came with a new burner gun and electrodes. The electrodes were not able to be adjusted to spec and carefully bending them with a pair of grips was the solution I ended up with also.

    • @tablespoon888
      @tablespoon888 2 роки тому

      I'm having problems with my boiler firing..the electrodes are not potty anymore...I adjusted the best I could and got it to fire..are the points important?

    • @pauleohl
      @pauleohl 2 роки тому +1

      @@tablespoon888 Yes, the spark jumps easiest and hottest from nice sharp points formed from clean smooth cones. If they are too far gone, replace the electrodes.

    • @rodgraff1782
      @rodgraff1782 Рік тому

      When your electrodes are spent, just replace them. They are cheap.

  • @patrickmurphy3
    @patrickmurphy3 10 років тому +1

    That's a great video and it really helped me tackle this project. Thanks again

    • @99quintinsnapshot
      @99quintinsnapshot 8 років тому

      +Patrick “KidsTooTall” Murphy You finally got off your damn ass and fix your burner.

    • @patrickmurphy3
      @patrickmurphy3 8 років тому

      I did. A year ago

  • @suffolkdowns182
    @suffolkdowns182 7 років тому +4

    Good stuff, nice job, thank you.

  • @donrondel8240
    @donrondel8240 Рік тому

    Clear concise accurate video. thanks very much

  • @TheFirstgoldking
    @TheFirstgoldking 9 років тому +4

    Thanks good usefull information..

  • @NoneMechanic101
    @NoneMechanic101 3 роки тому +1

    Great video. Thank you!

  • @randolphr
    @randolphr 9 років тому +3

    Thank you VERY much !!

  • @josemamani2580
    @josemamani2580 4 роки тому +1

    Excellent job, thanks

  • @ronsbeerreviewstools4361
    @ronsbeerreviewstools4361 7 років тому +1

    Thanks , a very good video.

  • @rogerbedardjr8135
    @rogerbedardjr8135 7 років тому +2

    Good info, thanks!

  • @BaFunGool
    @BaFunGool Рік тому +1

    Great Video, Well Done. Been on the nozzle - electrode rodeo ride many times in 40+ yrs.
    Often finding undersized nozzles via homeowner penny pitching.
    In many areas homeowners seek budget fuel from bulk carriers lacking service contacts, sometimes they receive cocktailed oil #4 - #2 mix.
    #4 oil still around, #6 totally gone. "Todd" rotary cup burners almost extinct.
    Myself as LMP having oil, pay my provider for service contact as insurance when I'm out of town.
    Wife calls - they run, service guy always gets a $50 tip, no matter what.
    Once my oil guy [good friend] came to set a few mouse traps, wife was standing on a chair freaking out when I was out of town. Thereafter got a cat from the shelter.

  • @mikee3997
    @mikee3997 Рік тому +1

    Thanks when I went to HVAC school we use to use a carpenters wood ruler to set gap and distance. Now I should look for a gauge like you showed easier I’m sure

    • @jfk64kennedy95
      @jfk64kennedy95 Рік тому

      i just replaced my Beckett leads today, the lead kit, included the small, cheap, stamped metal Beckett gauge, thankfully, $41 at my local plumbing supply house

  • @MrOso88
    @MrOso88 3 роки тому

    thanks for the help really nneded that video to readjust my electrodes

  • @davidhinton3595
    @davidhinton3595 5 років тому +1

    EXCELLENT video!!! A+++++

  • @labbeaj
    @labbeaj 7 років тому +3

    See how shiny that is? That is how the nozzle assembly should look after a year!

  • @BourneAccident
    @BourneAccident 3 роки тому

    Nice video. Thanks so much.

  • @jcstevegigs
    @jcstevegigs 3 роки тому

    Great info thank you!

  • @bobmarwood4232
    @bobmarwood4232 5 місяців тому

    Most helpful, thank you.

  • @lfdvidinc
    @lfdvidinc Рік тому

    Great video , you didn’t explain the ongoing painful life of an oil burner mechanic being on call 🤣🤣🤣 let’s not forget the never ending winters for us in the trades 🤟

  • @GSPenrithLTD
    @GSPenrithLTD 2 роки тому

    great video

  • @smestel
    @smestel Рік тому

    Awesome video!

  • @biglyon123
    @biglyon123 6 років тому

    Very nice video ....

  • @HarmonHeat
    @HarmonHeat 5 років тому

    Thanks a lot for the info bud. I'm gonna try to fix my mom's and save her some money! Edit: last night I took the igniter apart and cleaned it up and she's back in business. Thanks again!

  • @diytwoincollege7079
    @diytwoincollege7079 10 років тому +1

    Thanks for the info and great explanation.

  • @TerriInBC
    @TerriInBC 7 років тому

    Thank you

  • @gustavovelazquez13
    @gustavovelazquez13 6 місяців тому

    Great video! Thanks for you time doing it. I was looking for something like this. I wonder if you could/don't mind to share the document used to ilustrate the video. Would be nice to have that information printed for the next guy who will be in cherge of this Oil Furnace that I'm troubleshooting.

  • @Samos12
    @Samos12 4 роки тому

    Do you know what the consequences are of an electrode to high or too low above the nozzle, or the tip too close together? If I can't be exact, is it better to err on one side vs the other? Thanks!

  • @kommoncents5853
    @kommoncents5853 5 років тому

    My electrode tips are pretty close to yours, but had trouble understanding the gauge. As long as the furnace ignites right away and burns as it should with the right flame, am I so to speak okay with the electrode setting ?

  • @pamungkas5999
    @pamungkas5999 5 років тому +3

    Where am I can buy this one? Would you mind to give me the link?
    Thanks

  • @BMWang2020
    @BMWang2020 5 років тому +1

    thanks for your video.may i ask another question abt boiler.I changed boiler control computer UTCtime by mistake abt 3month ago.i was not ware that should not be changed.now the computer cannot display the trend at all.only can display shorttrend.can you help me to recover it,thaks a lot.i do not remember the UTC before change,so canot putback the time.from history also have no any information

  • @oakvue45
    @oakvue45 7 років тому +2

    Our old Montag keeps the electrodes firing as long as the unit is running...I think it's safer than trusting the cad-eye to detect no burning....I added an eye for extra safety. The down side is the electricity used by constantly firing the electrodes!

    • @CL-ty6wp
      @CL-ty6wp 2 роки тому +1

      Even with the old transformers you should have a flame sensor. If your trans or electrodes go, your tank of oil ends up on the floor. But yea it definitely seems to raise my electricity bill in winter

    • @oakvue45
      @oakvue45 2 роки тому +1

      @@CL-ty6wp We just had our place rewired and 4 new circuits added...now we heat with Electricity and our old Montag is resting...That old thing is built like a tank.

  • @Taras-Nabad
    @Taras-Nabad 4 місяці тому

    Good video

  • @bradw778
    @bradw778 5 років тому +2

    Curious about something. is the 1/8th" gap separation written in stone? I just did my furnace and the gap is a bit wider. The furnace starts up smooth and the flame looks good inside. Seems to run really well, but if the gap is an issue I'll pull it out and change it. Otherwise I'll just run it.

    • @KeithSpecialtyStore
      @KeithSpecialtyStore  5 років тому +1

      The 1/8" gap is only a rule of thumb. Each heating system can vary and you should use the instructions for it. Since it is running good, leave it the way you have it.

  • @mickhumpage4017
    @mickhumpage4017 4 роки тому

    Hi, just found this video, very informative. However I have a Karcher HDS555, I replaced the diesel injector and it does not give a spray when turned on. Just a 1 line stream, any advices would be appreciated. The fuel pump filter has been cleaned and the system purged.

    • @CL-ty6wp
      @CL-ty6wp 2 роки тому

      no nozzle or severely crudded up.

  • @anntalbot1071
    @anntalbot1071 8 років тому +1

    I posted the question about the beckett model AF15 burner. Where could I talk with a parts person to see if there are different length electrodes for this burner.

    • @cthulhu472
      @cthulhu472 7 років тому

      ann talbot contact the Beckett Corporation online and they can assist you on what to do, have a wonderful day😊

  • @sandroyarlequeponce2754
    @sandroyarlequeponce2754 7 років тому +1

    excelente

  • @mikestanovich6179
    @mikestanovich6179 7 років тому +1

    When my Igniter Failed, I had fuel leaking out the bottom of the Housing on my Heated Pressure washer.
    The Burner works well now, but when it fires up, I get a steady drip drip drip of fuel out the bottom. The drip stops as soon as I shut off the pressure washer wand and the flame goes out. I cannot find the source of the leak. I have read that some techs replace the internal insulation in the Heater body -- Is that a possible source of this Dripping? What else should I look for or replace? This is a 3 year old burner that has probably only been used for a hour or two TOTAL.

    • @miketaylor6282
      @miketaylor6282 3 роки тому

      I think you have a very small crack in your nozzle that isn’t revealed until under pressure from the fuel pump.

  • @kennyplay5982
    @kennyplay5982 4 роки тому

    Question. I have a Slant fin, winter summer hook up but I Do Not use hot water. I have an electric hot water heater. It say minimum nozzle is 1.00 80A... I was told that is a lot of oil being used. And then was told I could use a .85 because I don't use hot water, only furnace... Any thoughts on this ? Thx

  • @joeprete7424
    @joeprete7424 4 роки тому

    @Keith Specialty Store ...Can you tell me if Beckett Electrodes can be used in a Reillo Burner? Beckett's Electrodes are $15 and Riello's are $50, and the Service center tells me they are much the same, despite the price difference. Please give me your opinion. Thank You! ...Joe

  • @smsmetal
    @smsmetal 9 років тому +1

    SIMPLE !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!BASICS !!!!!!!!!!!!!!!!!!!!!!!!! REALITY !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! THX !!!!!!!!!!!!!!!!!!!

  • @lorraineoliver6451
    @lorraineoliver6451 3 роки тому

    thank-you.

  • @epsems1794
    @epsems1794 2 роки тому

    I just received my waste oil burner package similar to yours. How would I safely connect the ignitor module for the electrodes.

  • @anntalbot1071
    @anntalbot1071 8 років тому

    for a Beckett model AF15 seris oil burner I asked for electrodes for this burner when they came they were 1/4 " longer to set the right distances tolerances they are too long how to get the right part . the parts store says I have the right part what to do the furnace was purchased new 13 years ago

  • @bluelinebigfoot
    @bluelinebigfoot 2 місяці тому

    Graçias!

  • @blackhawk32b4
    @blackhawk32b4 4 роки тому

    Good video. Only thing You did not show how to remove the whole nozzle unit from the burner?

  • @perryfree3903
    @perryfree3903 6 місяців тому

    Just get you one of those orange plastic Beckett Z gauge my go to

  • @AIRMANBEAR
    @AIRMANBEAR 3 роки тому

    ARE THE WILLIANSON BURNER ADJUSMENTS ABOUT THE SAME AS YOU SHOWN

  • @captaincaptain3287
    @captaincaptain3287 6 років тому +1

    I have an AFII 85. The fan motor doesn't want to shut down after the burner stops. I have a Texas Instruments fan control switch 1NT21L-2616 but I can't find any info on how to adjust it. Can you help me?

    • @stevenfreeman6852
      @stevenfreeman6852 6 років тому

      my fan motor also runs for awhile after the burner shuts down. i have found this is normal. is is not adjustable. it is set at 140 degrees, and 170 degrees

    • @captaincaptain3287
      @captaincaptain3287 6 років тому

      My fan would run long after the burner stopped and push cold air out of the vents. Turns out, I had to replace the circuit board. One of the relays was bad. Now the fan shuts off after about 2 minutes. I thank you for your reply Steve.

  • @mikeythegreat242
    @mikeythegreat242 3 роки тому

    Just changed the oil pump on a Rheem furnace. Now everything the furnace blower Kicks on you can smell oil. Is this normal for a just changed pump. I can't find any leaks.

  • @charlessanders1342
    @charlessanders1342 6 років тому

    have Fire lake horizon oil furnace. electrodes are 1/2 9/16 apart...won't light unless you turn air pressure down to 5 psi from 12-13 psi.no adjustment for electrodes.

  • @littlespressurewashing
    @littlespressurewashing 2 роки тому +1

    Great video #littlespressurewashingservice

  • @tribulation138
    @tribulation138 6 років тому +2

    What if i buy a different size nozzle that sprays less oil? Will that save me money?

    • @daviddurham4875
      @daviddurham4875 6 років тому

      tribulation13

    • @forfrigsakes3330
      @forfrigsakes3330 6 років тому +2

      Not necessarily, could cost you more money, you want the proper size nozzle for your house/furnace, a smaller nozzle will just make the furnace run longer and if not set up or rated for your furnace will just soot it up and make a mess and possibly ice up and destroy your chimney.
      Best way to save on fuel is to have your furnace cleaned and maintained annually by a qualified technician with proper analyzing tools.

    • @mrdanforth3744
      @mrdanforth3744 6 років тому +2

      If you use a smaller nozzle you must adjust the air for proper combustion. The result will be that the furnace must run longer to produce the same amount of heat. And if you get really cold weather it may not be able to keep up.
      The whole furnace system must be sized and adjusted to suit your needs. A smaller nozzle won't necessarily save anything if you have to burn the same amount of oil for the same amount of heat. It will just take longer to warm the house.

    • @wiley0714
      @wiley0714 5 років тому +4

      You want to save money don't buy a smaller nozzle buy a nice throw blanket

  • @blbseauxmuchjake3877
    @blbseauxmuchjake3877 2 місяці тому

    Thanks, Keith! Youda gouda 🧀

  • @lansingdelee5553
    @lansingdelee5553 8 років тому

    Miller oil furnace won't ignite getting fuel can ignite manually then runs OK once it reaches the thermostat setting shuts off OK but when it starts back up loads with fuel but won't ignite. what's the problem?

  • @myhealthtoo
    @myhealthtoo 9 років тому +2

    My furnace turns off by itself and sounds like rumble sometimes then light goes on then I have to reset and turns back on.
    I have the temp set to 62 because its vacant right now

    • @AndrewAttard78
      @AndrewAttard78 6 років тому +1

      I have the same problem. I'm assuming it's because it's dirty. Do you remember how you fixed it?

    • @johnpicarojr.4618
      @johnpicarojr.4618 6 років тому

      cad cell replacement is needed

    • @johnpicarojr.4618
      @johnpicarojr.4618 6 років тому

      cad cell replacement is needed.

    • @keaters123
      @keaters123 6 років тому

      Wen was your furnace serviced? Change the oil filter , nozzle. It's failing to ignite , if your nozzle and filter are good and it's still failing to ignite, it could be your ignition transformer.

    • @jeffreyjohn2037
      @jeffreyjohn2037 5 років тому

      @@johnpicarojr.4618 wrong. Call a technician

  • @palangnar3588
    @palangnar3588 5 років тому +1

    Hi, thank you for this video, i have a question, my burner is a old Beckett series A,AF model burner, i have been using 1.10/80W nozzle, i just wonder if it is right one, also on the burner does it say the what nozzle size to use ?!

    • @jeffreyjohn2037
      @jeffreyjohn2037 4 роки тому +1

      You shouldn't tinker with an oil burner. Call a professional.

    • @palangnar3588
      @palangnar3588 2 роки тому

      @@jeffreyjohn2037 No way , i have been service it for 20 years man, i actually know better then some of service men just come to get your money.

    • @jeffreyjohn2037
      @jeffreyjohn2037 2 роки тому +1

      @@palangnar3588 what is the safety timing for your control?

  • @mikeruby1
    @mikeruby1 3 роки тому

    Thanks

  • @jermaineb3202
    @jermaineb3202 3 роки тому

    Nice

  • @NOBOX7
    @NOBOX7 5 років тому +6

    Bro those electrodes are like 1 inch form the nozzle

    • @btbt7496
      @btbt7496 4 роки тому +1

      I saw the same thing. The specs shown show 5/16", not 1/2.

  • @corey________________1589
    @corey________________1589 3 роки тому +1

    I’m trying to figure out what nozzle assembly i need so i can order it from you guys. Can anyone help me out?

    • @joebump7034
      @joebump7034 3 роки тому

      When you remove the cover to the boiler on the inside should be a sticker with the information

  • @rizabalanca2788
    @rizabalanca2788 2 роки тому +1

    That's what I'm talking about thank

  • @kimtarr2328
    @kimtarr2328 Рік тому

    Would you need to set electrodes if just changing the nozzle

  • @shawncahill8519
    @shawncahill8519 3 роки тому

    Can somebody explain to me why I had a service technician come in here and clean a brand new Thermo Pride furnace standard start shutting down I had to reset it was on lockout I reset this 5 times now it's running and I smell nothing but oil common oxide coming up to the floors in the trailer is this caused by him not doing this properly is it improperly installed nozzle or is it the igniters

  • @wilmorris4225
    @wilmorris4225 8 років тому

    The tips on mine are not pointed but squared off and blunt. How do I measure the gap in this case??

    • @LibertyDIY
      @LibertyDIY 7 років тому

      You can try to adjust them to spec and you might be able to get them close enough, or you can get new electrodes for ~$15

    • @oakvue45
      @oakvue45 7 років тому +1

      The electrodes should be squared off just like they come from the factory....Measuring gap is edge to edge and height above the center of nozzle is to edge of electrodes

  • @normanmitchell1631
    @normanmitchell1631 3 роки тому

    When and why did they change the height of the electrode from the tip c/l from 7/16 to 5/16?

    • @AmericanFarmerHVAC2024
      @AmericanFarmerHVAC2024 Рік тому

      Smoother lightoffs, works better in colder situations when the oil is thicker in viscosity.

  • @Randomgearhead
    @Randomgearhead 2 роки тому +1

    U just saved my ass. Heard my furnace not ignite and checked my electrodes the tips were burnt off and way out of adjustment. Took them to the bench grinder to make a nice point and adjusted them. Hit the reset button and it's back burning better than it has in years.

  • @davidfalensbirth2031
    @davidfalensbirth2031 Рік тому

    Awesome video! PleAse no music next time!

  • @rondoschiavoni8840
    @rondoschiavoni8840 8 років тому

    might be a stupid question however Ill ask you anyway, once a oil burner fires up, does the transformer continue making the arc spark in front of the nozzle or not?

    • @Lecon60
      @Lecon60 8 років тому

      +Rondo Schiavoni Your transformer should shut down. If it does not the flame sensor is not working. (Its the electric eye attached to the transformer)

    • @rondoschiavoni8840
      @rondoschiavoni8840 8 років тому

      IN OTHER WORDs THE TRANSFORMER IS NOT needed TO KEEP THE FLAME BURNING UNTIL THE WALL THERMOSTAT in your home TELLS IT TO SHUT OFF?

    • @bigpardner
      @bigpardner 8 років тому

      +lecon chuitt What keeps the flame going then, once the flame is established as long as oil spray keeps coming the flame is maintained?

    • @rondoschiavoni8840
      @rondoschiavoni8840 8 років тому

      so the bottom line is after the transformer electrodes spark the flame to get it started , then the cad cell sees the flame and shuts off the transformer and it the flame stays burning by the pressure and atomized spray until the oil pump shuts down then the flame stops,is this correct?

    • @bigpardner
      @bigpardner 8 років тому

      Rondo Schiavoni Like you, I'm not so sure. No straight answer yet. I'll have to read up on it.

  • @briansomershoe4166
    @briansomershoe4166 3 роки тому

    👍

  • @darrealemerick8685
    @darrealemerick8685 3 роки тому

    I found a way to test if you got them right use a stun gun works real well.

  • @kevinshea4776
    @kevinshea4776 9 місяців тому

    After removing my nozzle, a metal rod was inserted behind the nozzle. Is that normal and why was that there?