Design of Cantilever Slab | Civil Engineering

Поділитися
Вставка
  • Опубліковано 17 гру 2024

КОМЕНТАРІ • 89

  • @subhashhansda4612
    @subhashhansda4612 4 роки тому +4

    Thank You Mam , You are doing a terrific work for Us (Civil Engineers). You have solved all my doubts.

  • @بنمفازي
    @بنمفازي 3 роки тому

    Mam ; memorize me during my college era in Engineering 😊😊😊

  • @AdarshKumar-dl6lq
    @AdarshKumar-dl6lq 3 роки тому +1

    Allot of mistakes, effective span for cantilever salb is d+ clear span.
    As per Is code , for cantilever slab l/d ratio is 7,
    Depth is varying, but you consider maximum depth as obtained at fixed support.

  • @viplavranjan1207
    @viplavranjan1207 3 роки тому

    Very well explained 👍👍👍👍

  • @beenay18
    @beenay18 2 роки тому

    the (l/d)max value is unitless but you have put mm unit on it by mistake. overall I enjoyed your video a lot. I haven't been able to learn these stuffs from books because of my very short attention span, but I was able to understand it from your concise and to the point video. Your video was clear and engaging. Thanks a lot. I cant thank you enough. keep up the good work.

  • @saifuddin6353
    @saifuddin6353 4 роки тому +9

    Mam as per is 456 the l/d ratio is 7 for cantilever but your taking l/d as 12 please mention clause no

  • @Khonkada
    @Khonkada 7 місяців тому

    Will this Slab hold if extended freely without any support from cantilever beam below, at every juntion of Column.
    Please answer 🙏 I need to know

  • @mushtaqmirza9209
    @mushtaqmirza9209 4 роки тому

    Mam your voice is very clear
    I like it 😊

  • @sasikumartherayil9620
    @sasikumartherayil9620 5 років тому +2

    Now a days cantelevet slabs are designed for even two metre span.
    However as mild steel is not available we are forced to use Fe 500.
    With this steel depth is very high.
    Are there any suggestion to reduce depth by using compression steel etc .
    Any information madam to deal such situation

  • @sireeshjakati8377
    @sireeshjakati8377 4 роки тому +3

    Mam can u please tell how to design beams with Mz and Fy value we get from staad pro

  • @sattar0099
    @sattar0099 5 років тому

    Nice calculations and clear 👌

  • @quaisrazakhan8596
    @quaisrazakhan8596 4 роки тому

    Nicely and clearly explained (y)

  • @safdarkh786
    @safdarkh786 4 роки тому +1

    Shouldnt we use tau v equation of varying depth to find tau v for tapered end slab?

  • @beenay18
    @beenay18 2 роки тому

    which clause of which code is followed to take the depth of slab=1/12 of the overhang? I could not find it in IS:456. Could you help please?

  • @kalidass3
    @kalidass3 5 років тому +1

    Mam for Cantilever slab span/depth ratio as 7 only na.. then why should you take (span/10 or span/12)..

    • @karbeenhiwa7756
      @karbeenhiwa7756 5 років тому

      I think this is ACI318 code

    • @ItIsArpanKoirala
      @ItIsArpanKoirala 4 роки тому

      Yes i was also confused here. For cantilever it is span/7.

    • @Christopher3437-q4m
      @Christopher3437-q4m 3 роки тому

      Span /depth = 7 X modification factor ..so it will actually 10 or 12mm...so mostly 12 is taken ..so that after the design...l/d max will not be greater than (7 X modification factor). ...and hence ok in deflection...

  • @binayaksamanta863
    @binayaksamanta863 4 роки тому +5

    For effect depth calculation you take span/10 to Span/12 can you tell me the reference clause number and according to which code ??

    • @ichweinicht1858
      @ichweinicht1858 3 роки тому

      It ain't given in code it is kinda thumb rule

  • @rizwan1396
    @rizwan1396 2 роки тому

    Very informative video ma'am, mujhe ek doubt hai cantilever slab me bhi one way two way slab hota hai kya ya continuous type esa kuch hai????? Please clear my doubt

  • @jaiharris9824
    @jaiharris9824 5 років тому +3

    Thanks a lot sister I request to your previous video to make a video for cantilever slab thanks for upload this video

  • @nh4064
    @nh4064 3 роки тому +1

    Maam, Isn't it l/7 to l/10 for cantilever slab as per IS 456?

  • @adegbolaebenezer272
    @adegbolaebenezer272 3 роки тому

    Thanks for this teaching. Amazing job and good voice.
    1. Please what is the 1000mm you used for calculating the self weight of slab? (0.20x1.00x25).
    2. Please what is 'b' in the formula for checking for depth and why is it 1000mm?
    Thanks as I look forward to your reply.

  • @sasikumartherayil9620
    @sasikumartherayil9620 4 роки тому +1

    Good presrntation
    We have assumed 10mm dia bars.
    Provided is 8mm.
    Distributiin can be reduced to. 12 %of thickness. Provide with 8mm bars.
    What is missing in this video
    1. Behaviour of slab
    2. Behaviour of support is not explained.
    3.detailing is in complete
    Generally compression steel is provided
    Detailing at support.
    What forces are transferred to the support.
    What about torsion
    What are the support for this beam supporting the slab
    What about the overturning of slab.
    Is the support strong enough.
    Madam if you bring all these aspects your good presentation will become excellent.
    Even you forgot to draW BM SF deflection etc
    3.

    • @cwillstructures
      @cwillstructures  4 роки тому +1

      Thank you so much.
      I will keep all these points in mind.
      It's just that to cover all the points in single video is difficult.
      I have explained these concepts in my other video tutorials ( may be not in single video).

    • @sasikumartherayil9620
      @sasikumartherayil9620 4 роки тому

      There are numerous text books and yiu tubes.
      Your videos are really excellent.
      Free body diagram
      Idealisation
      Forces
      Bm
      Sf
      Deflection
      Any other forces
      Supports
      Detaili g
      Detailing dos donts
      All such parameters make a video useful.
      I mean good to excellent.
      The viewer should learn correct things.
      Many people are giving foundation size for three storied building etc. Those are all nonsense.
      All the best

  • @bhargavpatel8572
    @bhargavpatel8572 4 роки тому

    Nice Explanation... But how to take live load when designing for balcony for particular plan plz. Tell

    • @mr.perfect_456
      @mr.perfect_456 4 роки тому +1

      Take live load for balcony as 3kn/m2

    • @bhargavpatel8572
      @bhargavpatel8572 4 роки тому

      Thanx for taking time 4 me and replying.... Nice work done by you keep it up.....

    • @NirmalNikhil
      @NirmalNikhil 4 роки тому +2

      For balcony the max value will be taken as 5kn/m2 and min value is taken as 3kn/m2 as per iscode 875 :1987 part 2

  • @akankshitha8110
    @akankshitha8110 3 роки тому +1

    Please do a video for T and L beams madam.

  • @RohitSingh-xb8ic
    @RohitSingh-xb8ic 3 роки тому

    Is it limit state method or working stress method

  • @knrking007
    @knrking007 5 років тому

    I am a big fan and die hard subscriber of your channel
    I have a small doubt in this video...while taking selfweight the crossection of the beam is varying from fixed end to the end so....it should also be considered or can be neglected

    • @cwillstructures
      @cwillstructures  5 років тому +1

      You can take maximum depth in consideration.
      Thank u so much

    • @Christopher3437-q4m
      @Christopher3437-q4m 3 роки тому

      @@cwillstructures why Maximum depth is taken? What is the role of smaller depth at free end ?

    • @fistonndongalo139
      @fistonndongalo139 3 роки тому

      @@Christopher3437-q4m maximum depth just for safety factors

  • @Benza96
    @Benza96 2 роки тому

    Why did you provide 8mm bad dia which covers an area of =50mm^2 steel when the code shows that the mim should be 240mm^2

  • @md7123
    @md7123 3 роки тому

    Mention the clause or page number where effective lenght is described for cantilever slab

  • @mohamedanas1152
    @mohamedanas1152 4 роки тому +1

    In step 2 to find overall depth it is (effective depth+clear cover+bar dia/2)
    Not effective cover

    • @safdarkh786
      @safdarkh786 4 роки тому

      What is the difference between clear cover and effective cover?. Often hear these terms used synonymously!

    • @mohamedanas1152
      @mohamedanas1152 4 роки тому

      @@safdarkh786 clear cover is minimum spacing b/w reinforcement bars and bottom surface of beam
      Effective Cover means clear cover+diameter of bar/2

    • @vincentmarcelo8165
      @vincentmarcelo8165 3 роки тому

      Yes it should be either 1)overall depth - clear cover+1/2 dia of bar or 2) overall depth-effective cover

    • @mikehussain3494
      @mikehussain3494 2 роки тому

      True ...one can directly use 30mm for slab as effective cover if not given

  • @ravikumarpillai1473
    @ravikumarpillai1473 5 років тому

    Madam, what is the angle maximum and minimum we can provide for staircasr, pls

  • @santoshmandal1054
    @santoshmandal1054 Рік тому

    Dia of main bar min. 12mm liya jata h mam 8mm nhi..

  • @charlesdobronxoliveira8292
    @charlesdobronxoliveira8292 3 роки тому

    If it is of varying depth then self weight calculation will be different

  • @mohsininamdar4659
    @mohsininamdar4659 4 роки тому

    Plz mam teach us designing of structures using staad pro software.

  • @beenay18
    @beenay18 2 роки тому

    which book is it from?

  • @SanjayKumar-gy8et
    @SanjayKumar-gy8et 5 років тому

    do u design building structure on chargeable basis ??

  • @Er.Rahul__kumar71
    @Er.Rahul__kumar71 Рік тому

    Mam please slow bataye to acchi tarah se samaj me ayega

  • @a2sirfanclubshorts246
    @a2sirfanclubshorts246 4 роки тому

    In Area of steel formula (BxD) is missing after the bracket ends.

  • @zeust.v.857
    @zeust.v.857 4 роки тому

    Mam ye width of support kaise nikaal please bataeeye

    • @Christopher3437-q4m
      @Christopher3437-q4m 3 роки тому

      Support is actually the wall and generally it's width is 230mm taken...u can see in many plans of building design, width of wall is 230mm or sometimes it will be 300mm ...this is in case of external walls ... internal walls will have half width of external ones

  • @StephenSairo
    @StephenSairo 5 років тому +2

    Thanks for the videos but we need real working projects

  • @Rimjhimvideo
    @Rimjhimvideo 3 роки тому

    Thanks

  • @mahendrakumar8955
    @mahendrakumar8955 5 років тому

    Mam kya yah LSM method se hai

    • @cwillstructures
      @cwillstructures  5 років тому

      LSM

    • @sasikumartherayil9620
      @sasikumartherayil9620 5 років тому

      Sasi Kumar Therayil
      8589070815
      designersasikumar@gmail.com
      Madam I have already subscribed your channel
      Kindly inform when you add
      Slopping slabs
      And mat slab

  • @SoumyaRanjan-ls5ce
    @SoumyaRanjan-ls5ce 4 роки тому

    L/d = varying from 10 to 12 ... IS Code 456-2000 page no.??????

    • @SoumyaRanjan-ls5ce
      @SoumyaRanjan-ls5ce 4 роки тому

      Why Don't we determine the Depth from Deflection formula..????

  • @civilengineeringbasic
    @civilengineeringbasic 5 років тому

    What to do if it's fail in shear?

    • @NirmalNikhil
      @NirmalNikhil 4 роки тому +1

      Shear failure can be prevented my providing shear reinforcement in the form of stirup or bent up bar in the case of slab design the alternate bent up we provided near the support not only prevent the negative moment but also prevent shear failure

    • @Christopher3437-q4m
      @Christopher3437-q4m 3 роки тому

      @@NirmalNikhil what's the step if we fail in deflection?

    • @mikehussain3494
      @mikehussain3494 2 роки тому

      If we fail in shear ..we have to redesign the slab by taking another depth ...at every check fails, depth should be changed and redesign again...

  • @veekshits2098
    @veekshits2098 3 роки тому

    Why did you Stop making videos?

  • @NitishKumar-vs3vw
    @NitishKumar-vs3vw 4 роки тому

    10 mm bar ko assume kiye h na

  • @harbhamaodedara7520
    @harbhamaodedara7520 4 роки тому

    please let me know how to interpolate

    • @cwillstructures
      @cwillstructures  4 роки тому

      ua-cam.com/video/6At39ulPXXU/v-deo.html you can watch this video tutorial

  • @amritanshumaiden
    @amritanshumaiden 5 років тому

    Please can you limit the distribution steel to minimum

  • @sanjeevreddy1756
    @sanjeevreddy1756 5 років тому

    Will u teach staadpro?

  • @Premkumar-ve9xr
    @Premkumar-ve9xr 5 років тому

    Super work sister

  • @sowmiyaseelan7533
    @sowmiyaseelan7533 4 роки тому +1

    Tq mam

  • @mdubedhasmi8115
    @mdubedhasmi8115 5 років тому

    I want a contact numbr where i can learn design of structures

  • @arundey6673
    @arundey6673 5 років тому +1

    SISTER ISSE ACHHA VIDEO AUR NAHI HOTA. HEAQRTIEST THANKS. Arun dey

  • @ezhilarasan3776
    @ezhilarasan3776 5 років тому

    Pls do moment distribution method for beam and frame

  • @RAHULRR10
    @RAHULRR10 Рік тому +1

    where are u rushing,plz take ur time and go slow..

  • @IshwarSingh-bp5tp
    @IshwarSingh-bp5tp Рік тому

    L/7 and L/10 to 12 is not clear

  • @Er.Rahul__kumar71
    @Er.Rahul__kumar71 Рік тому

    Padati to ap accha hai mgr express ke tarah bhag rhi

  • @zeust.v.857
    @zeust.v.857 4 роки тому

    Please mam

  • @nothing.713
    @nothing.713 2 роки тому

    Very bad way of teaching mam some points are not mention.