Pentair Mastertemp125 heater troubles - watch to the end

Поділитися
Вставка
  • Опубліковано 12 вер 2024
  • Purchased brand new Mastertemp 125 heater May 2021 with additional Pentair parts warranty.
    Worked great for one month and then began cycle of igniting, fan blowing heat, then shutting off after 3-5 seconds.
    Beware of endless cycle of being sent replacement parts only to have you have to hire qualified technicians to install them over and over, paying out of pocket each time. And finally, they’ll ask you to ship the whole thing somewhere of their choice, having to arrange your own shipping and pay expensive freight costs.
    No heater is worth this much headache and poor customer service. This unit should have been replaced and would have been if they value their customers at all.
  • Фільми й анімація

КОМЕНТАРІ • 39

  • @alexbutu9636
    @alexbutu9636 Рік тому +3

    ive been having the exact same issue and have spent days trying to figure it out and then i read the comments on this video about a technician adjusting the gas valve a quarter turn and it solving the problem, i just finished doing the same thing and it worked!!!!! but i had to turn mine half a turn because a quarter turn was still doing the same thing and shutting off after 5 seconds, thank you so much for posting what you did

  • @gregmoore5823
    @gregmoore5823 2 роки тому +5

    Everyone of these pool heater should be recalled

  • @blancaramirez1764
    @blancaramirez1764 Рік тому +4

    I am a pool repair technician. one time I had a customer who had a similar problem and the problem was a loose wire on wire harness.

    • @chiko82mx
      @chiko82mx 9 місяців тому

      what wire? i have a couple heaters with the same problem

  • @user-tx4yq7kl6c
    @user-tx4yq7kl6c Рік тому +1

    I’ve fixed the same problem in the field by changing the air flow switch even though the system is saying ignition error. Most Pentair tech support people are unaware of this solution. Your system is igniting, but the call for air is tripping a bad air flow switch.

  • @offspeedvibes
    @offspeedvibes  2 роки тому +2

    So hey guys, I empathize with your frustration, as you can tell from my video. This seems to be the worst heater and has been the worst supported product I’ve ever bought. We finally were referred by Pentair to a technician who came and fiddled with it for five minutes and figured out that it is our gas valve that was the problem. He gave it a quarter turn and it started to run. He then told us that we needed to replace the gas valve with a new self-regulating one. And he ordered that and it has been on back order for the entire summer. We still haven’t seen it.
    The most frustrating thing has been that I received no real successful support until I made a stink and posted it online and on their Twitter accounts. I really hope you find success as it’s the worst to have invested money in something and not be able to use it.

    • @countymed2000
      @countymed2000 Рік тому

      VERY BAD CUSTOMER SUPPORT , DONT BUY PENTAIR PRODUCTS ANYMORE

    • @miguelgarcia2275
      @miguelgarcia2275 Рік тому

      I have this same heater and it stopped working after 5 times of using it

    • @crashcarney100
      @crashcarney100 11 місяців тому

      I’m on my 2nd 125k I’ve missed 4 seasons. Only for Pentair to take NO ACCOUNTABILITY. I have less than 4 hrs of usage between 2 units.
      It’s a water issue. 6 service bills.
      NOT COVERED UNDER WARRANTY… UGH!
      I have my water tested…No issues

    • @jesuscarela7131
      @jesuscarela7131 8 місяців тому

      Hola tengo uno Haci me uedes ayudar

  • @MichaelSmith-ho8cx
    @MichaelSmith-ho8cx 2 роки тому +1

    My pentair unit has been bad also. Bought new. It’s gone thru numerous different parts. I still have it and plan to keep it for now but these units kind of suck for lack of a better term. I try to fix myself also. A part here and a part there. UA-cam clip and I go at it again. Warranty was parts only. Dissatisfied here too. Sorry about your situation. I’ve been able to get mine working after completely taking it apart but now it’s broke again. The main board stoped functioning

    • @countymed2000
      @countymed2000 Рік тому

      VERY BAD CUSTOMER SUPPORT , DONT BUY PENTAIR PRODUCTS ANYMORE

  • @peterkozhenevsky9500
    @peterkozhenevsky9500 Рік тому

    I have the same problem. Thanks for your post.

  • @crashcarney100
    @crashcarney100 Рік тому

    I feel your pain.
    I think I am gonna take the accountability to the Pool Manufacturer... Since they sold me the pool w/heater. I had no say in brand or style, btu’s Ext..
    So disheartening!

  • @manuelquintela4994
    @manuelquintela4994 2 роки тому +1

    Same here; we installed it in July 2022, and we have the same exact issue. Very frustrating.

    • @mikecohen5376
      @mikecohen5376 Рік тому

      I had the exact same problem. Mine showed a C05 error code. I replaced the Pentair Stack Flue sensor (Part # 42002-0024S from Amazon $11.89). Easy to do. Now it works great. But I sure would like to find out how to heat to 106 degrees.

    • @cainortiz1496
      @cainortiz1496 Рік тому

      Maybe ur trv needs to be replaced

    • @alexbutu9636
      @alexbutu9636 Рік тому

      adjust your gas valve screw a quarter turn or half a turn clockwise and it will solve your problem

    • @pierrelopez7061
      @pierrelopez7061 10 місяців тому

      @@alexbutu9636where is that?

  • @ellisrivera8081
    @ellisrivera8081 Рік тому +1

    Change the air flow switch i had fixed heater with similar problems the different is that some of then turns for 1 minute and turn off other 5 minute and turn off

    • @countymed2000
      @countymed2000 Рік тому +1

      this is a new pool heater , why should it had parts that needs to be change.

  • @fasteddie4145
    @fasteddie4145 Рік тому

    it's the thermal regulator which is basically a thermostat like found in a car....

  • @STXVIEC
    @STXVIEC Рік тому

    All those diagnostics are incorrect. Is your gas meter close? how far is the gas line? an ignition error is due to a faulty gas valve or the air intake is trapped. Seems to have nothing to do with the product pentair made. You could watch my video on my jandy heater that failed.

  • @gregmoore5823
    @gregmoore5823 2 роки тому +1

    Mine was hooked up July 18, 2022 and I’ve had the same problem every time this heater cost me $4200 and it’s the biggest piece of junk I could take five baseball bats to it

  • @MrJimmy39
    @MrJimmy39 Рік тому

    I have a mastertemp 250 as well. Just purchased from a previous owner. Its less than a year old. Heater Ignites and then shuts off after about 10-15 seconds. I switched the heater from Natural gas to Propane. I changed the Orifice and replaced with propane. Bought a regulator for propane. Any ideas what it could be? I have replaced the high limit switch and no luck.

    • @alexbutu9636
      @alexbutu9636 Рік тому

      adjust your gas valve screw a quarter turn or half turn and it will solve your problem

    • @nickhughes2742
      @nickhughes2742 Рік тому

      ​@@alexbutu9636 what gas flow valve?

  • @blancaramirez1764
    @blancaramirez1764 Рік тому

    most of the time low gas pressure coming from the main meter can cause this problem.

  • @gregmoore5823
    @gregmoore5823 2 роки тому

    I have the same thing

  • @gregmoore5823
    @gregmoore5823 2 роки тому

    Make sure it’s turned on on the inside that was the problem with mine when they installed it they didn’t turn it on take the back cover off and there’s a switch that you turn it on and off turn it on and it should work

    • @countymed2000
      @countymed2000 Рік тому

      mine cost $4000 plus , switch is turned on but still doesn't work. its brand new and customer service is telling me i need to hire and pay a pentair tech to fix it. why should i pay someone to fix something that supposed to work because its new.

  • @gregmoore5823
    @gregmoore5823 2 роки тому

    Me too

  • @gregmoore5823
    @gregmoore5823 2 роки тому

    Mine only runs for about three minutes and then it does the same thing

    • @crashcarney100
      @crashcarney100 Рік тому

      What was the error in your heater.
      Mine will flash “AFS”
      (Air Flow)
      At the shutdown shows EO5.
      This is my second unit since 5/23,
      this one at least worked through the season.
      Upon opening this past week it won’t allow me to heat.
      Daughter’s College Graduation is Sunday... UGH

    • @patriciaphillips8963
      @patriciaphillips8963 24 дні тому

      😊​@@crashcarney100