How to test 3-Phase motor winding insulation

Поділитися
Вставка
  • Опубліковано 31 січ 2025

КОМЕНТАРІ • 16

  • @athilaldurry5880
    @athilaldurry5880 13 днів тому

    Good job continue please test the cables please ❤❤

  • @athilaldurry5880
    @athilaldurry5880 13 днів тому

    Many thanks for useful information ❤❤

  • @metrowash
    @metrowash 10 днів тому

    Thanks so much!

  • @mcdonnellsinc
    @mcdonnellsinc 4 місяці тому +7

    can you please tell the 3.1k viewers the name of your business, so we can avoid having you "troubleshoot" and misdiagnose our equipment 😅

  • @indikaudayasaranga988
    @indikaudayasaranga988 28 днів тому

    Thank you bro.

  • @amandeepchahal007
    @amandeepchahal007 9 місяців тому

    Good job 👍

  • @DallasAutoDiag
    @DallasAutoDiag 7 місяців тому +2

    As far as i know a 3 phase motor windings are not suppose to have any continuity between any given 2 phases. just like between any given phase and the motor case. in your testing when there was 0 resistance between 2 phases on motor 1 you said "this is good" which is actually not. and the opposite happened on motor 2. in addition, you were suppose to hole the test button for a minimum of 60 seconds to see if there is any drop in the resistance. in short, Hi resistance=good, Low resistance or a 0v reading=bad.

    • @LifeOfEngineering-dm7fk
      @LifeOfEngineering-dm7fk  7 місяців тому

      Thnak you so much for your response I will make sure that I will provided you right information but Thank you.

    • @bobbauvian7700
      @bobbauvian7700 6 місяців тому

      if phase wires are not connected in a 3 ph motor, how will the motor run then? I think may be we all need to learn more.....

    • @Josh-px6xb
      @Josh-px6xb 4 місяці тому

      3 phase motor windings WILL have a resistance reading between the windings . If it didn’t that mean it would be a bad motor. All the windings are tied together

    • @bobbauvian7700
      @bobbauvian7700 3 місяці тому

      Oh OK I got it. not sure if I am correct. but in the motor electric box, where all the wires are. if everything is disconnected then the windings are not connected. correct?

    • @Josh-px6xb
      @Josh-px6xb 3 місяці тому

      @@bobbauvian7700 dual voltage motors won’t be connected for an example . (If you have a 9 lead motor)

  • @WNAZ-WALA
    @WNAZ-WALA 2 місяці тому

    Thanks for the

  • @richardlang2185
    @richardlang2185 4 місяці тому +3

    This video is incorrect how to use this FLUKE tester and incorrect how to test motor for Insulation Resistance. Insulation Resistance on motor is done by Polarisation Index PI what this FLUKE tester provides.

  • @argelgus
    @argelgus 5 місяців тому

    No No No