Cause means Reason ...effect mean..asar ..yaani ..output according to input ...we put some logic in Fire Alarm panel ....we need some out put in according to our required input
Matlab h ke battery ya piwer supply yani m.ac power jisse panel ko power mil raha h ..ussem koi fault h ...fuse check kijiye ya battery ka voltage ch3ck kijiye ..ghata hua na ho
Address rahta h. Jaise 3.21 means ..loop3 and address 21 pe ..amd devcie ka type rahat h jaise MKII-AOP AAP MERA EK VIDEO DEKH LIJIYE. ua-cam.com/video/jyMOOv81PYI/v-deo.htmlsi=6gQV7Uf3jZfDIqLP
Aise ye network fault h ...aap apne panel se connected repeater panel ko check karen...koi missing y ya kisi repeater panel me koi power issue h ..baatery ka trouble h ......koi repeater panel off to nahi h ..
very nice
Thanks
Brother add programming with laptop please upload video@@superknowledge3135
Assalamu alaikum warahmatullah
Khairiyt se Hain bhai
Wa Alaikum Assalam .
Alhamdulillah..theek hain
Nice
Thanks
Mimic panel pr ek video bnaye bhai plzz
Okay....
Est3 ka Programming bare me kuch bataye sor
Uski programming software se hoti h
Panel se option nahi h
Jab mauqa milega to batayenge ..insha Allah
Possible to silence or disable all sounder in premier Al zeta panel.. Please give the advice
Yes..
I can send you the manual ..you can check .
Yes bro
Causes and effects kya hai sir
Assalamu Alaikum bhai...aapne ye video poora dekha b kya ?
Cause means Reason ...effect mean..asar ..yaani ..output according to input ...we put some logic in Fire Alarm panel ....we need some out put in according to our required input
hello sir how to add devices and how to delete devices
By Autosearch of the loop .,...it will add the connected devices and remove the disconnected device.
tx sir
Points delet keche korna please sir
Just ..remove and ..re configure
Bro What is Lcd fault in zeta premier Quatro pls how to solve this???
Check the cable connected to LCD or Display ..
Please do you have it in English
No..i will upload in English
Aap mobile ko ek jagah fix karke rakho sirji aur aawaz bhi clear nhi hai
Sorry...next time ..clear se bolunga..
Power supply fault ka kya matalb है
Matlab h ke battery ya piwer supply yani m.ac power jisse panel ko power mil raha h ..ussem koi fault h ...fuse check kijiye ya battery ka voltage ch3ck kijiye ..ghata hua na ho
Bhai please reply me
Mujhe 6 smoke add karne Hain panel me kaise Karu
Number daal diye hain
Bs add karna h panel me address bhi dena h
Mera video dekhiye ...simplicity plus wala .
Yah sim panel mein fire hua hai usko kaise adress pata kar sakte hain
Address rahta h. Jaise 3.21 means ..loop3 and address 21 pe ..amd devcie ka type rahat h jaise MKII-AOP
AAP MERA EK VIDEO DEKH LIJIYE.
ua-cam.com/video/jyMOOv81PYI/v-deo.htmlsi=6gQV7Uf3jZfDIqLP
Sir Agar sound silent 🔕 kardiya to flash Nahi band Hona Chahiye kaise thik kare
Dono ko ek hi command hoga ..
Dono band ho jayega .
Flasher bahre logon ke liye h..
Assalamualaikum one mcp not working in zeta panel how to solve this issue
Did you remove the jumper from MCP .
And addressing is done or not .. connection is ok?... Then configure the loop
Jab sound silent karte hai tab flash v band ho ja Raha hai flash Nahi band Hona Chahiye sir
Check karna hoga ke ..dono ka command ek hi h ya ..
Sir zeta k simplicity panel ma device fail bata rha ha sari divice fail bTa rha ha kia problem ho sakti ha programing ki ?
Configure karke dekhiye ...
Configure kaise karna hai
controller fault coming how can solve
Send me the image on whatsapp - +966506265122
Aise ye network fault h ...aap apne panel se connected repeater panel ko check karen...koi missing y ya kisi repeater panel me koi power issue h ..baatery ka trouble h ......koi repeater panel off to nahi h ..
Ye system mere pas hy iska keypad nh work kr raha hy sir
Hard reset karke dekhiye ..open karke clean bhi karke dekhiye ..
@@superknowledge3135 kr lita hy sir battery bhi nikali hy power off kr ke but keypad nh Kam kar raha
@@superknowledge3135 apka number mil sakta hy
Ji
Shayad faulty ho gaya ho ...
Keypad is not work
Check ..may be faulty ..or clean
Tow alarm show 1st battery and 2nd alarm loop 1 and 2
Solve kijiye .
Reset karen..agar dirty hoga to dobara ayega..clean kar dijiye .
How to disable,enable device
Dear Prabhath
Have a nice day
I will upload a new video about it.
Thanks for comment.
Dear Prabath ji
Now you can watch the video about
How to Disable and Enable a Device in premier quatro zeta panel.