COD Analysis Procedure, cod testing procedures.

Поділитися
Вставка
  • Опубліковано 5 лют 2025
  • Dear Friends, Here we are sharing COD analysis procedure, please watch this video and subscriber this channel.
    #codanalysisprocedure
    #codtestingprocedure
    #codanalysismethod
    #codtestingmethod
    #codtesting
    #labtesting
    #codtest
    #aquazone
    #aquazoneengineering
    #etptesting
    #chemicaloxygendemand
    Determination of Chemical Oxygen Demand (COD)-A Complete Procedure (Dichromate Mercury Free Method)
    What is Chemical oxygen demand | analysis of high [COD] sample | Dilution method | Science classes
    Chemical oxygen demand | COD | Calculation of COD | Chemical oxygen demand in hindi |
    3 Determination of COD of waste water | Chemistry Lab Experiments | VTU | 14CHEL17
    Chemical Oxygen Demand (COD)
    DETERMINATION OF COD OF WASTE WATER-Part-1
    How to Analyze Chemical Oxygen Demand in Water

КОМЕНТАРІ • 52

  • @saritasharma6884
    @saritasharma6884 3 роки тому +3

    Understand completely, thanks for sharing

  • @mustaquealam2388
    @mustaquealam2388 3 роки тому +1

    Good knowledge .
    Deeply explain

  • @tarunsharma-xd4jh
    @tarunsharma-xd4jh 3 роки тому +1

    Satisfied with the Information

  • @tdsontrack6241
    @tdsontrack6241 3 роки тому +1

    Thanks for this video sir. 🙏

  • @sainanamrangcharai6611
    @sainanamrangcharai6611 Рік тому

    Nice concept sir Ji 🙏

  • @jayantanaik4583
    @jayantanaik4583 2 роки тому

    Very helpful.

  • @angelneha9651
    @angelneha9651 3 роки тому

    Good knowledge 👍

  • @IndianCurrywithNeha
    @IndianCurrywithNeha 3 роки тому

    Nice explanation sir

  • @ajayawara5221
    @ajayawara5221 3 роки тому

    Nice video

  • @ShamaParveen-zo4hp
    @ShamaParveen-zo4hp 3 роки тому

    Understandcompletely
    Thanks

  • @fayazahmadmir9026
    @fayazahmadmir9026 2 роки тому +4

    Please tell you have mentioned that burette reading of blank as 11.1 and burette reading of sample 10.5.The fact is that higher burette reading means higher COD.
    When Burette reading of blank is high it means its COD is high,which in turn means blank sample has higher organic content and incubated sample has low burette reading and low COD

    • @arvindthakur8840
      @arvindthakur8840 Рік тому +3

      This is for your clearance: - please note that this is kind of back titration method. suppose you have some organic matter in the sample which shall be completely digested by some amount of K2Cr2O7, and surplus Potassium Dichromate shall be titrated with the FAS for calculation. Now in blank sample there is no impurity which means whole Potassium Dichromate is to be titrated with FAS and consumed more in Blank. that's why Blank reference is also considered in in the testing.
      hope this will help you.

  • @दिलसेपहाड़ी-ध9ल

    Sir have a question . Your Burrett reading is approx 10 to 11 how can possible this in two different normality of solutions 0.25 and 0.1N.

  • @pankajkumar2210
    @pankajkumar2210 2 роки тому

    Thanks 🙏👍🙏👍

  • @vai88888
    @vai88888 29 днів тому

    After digestion kitna DM water add kiya?

  • @sokunlehakeem
    @sokunlehakeem 5 місяців тому

    Can it be done in English? Also is it compulsory to digest the sample? Why can't we titrate it direct

  • @shikhajha4035
    @shikhajha4035 Рік тому

    Sir is there no need of COD digestor for the process to occur

  • @haripatel9468
    @haripatel9468 2 роки тому

    Thank you sir !

  • @AmolLinge-sy9of
    @AmolLinge-sy9of Місяць тому

    Sir mera blank hi green ho rha hai kya problem ho shkti hai please reply

  • @arushupadhyay2894
    @arushupadhyay2894 Рік тому +1

    Audio is very low please solve this

  • @maditetiontimenittu2869
    @maditetiontimenittu2869 2 роки тому +1

    Sir BOD,TDS,PH,DO,etc test ka video pura with regent and calculation ka banaye

    • @bhanu_sangita
      @bhanu_sangita 2 роки тому

      Bilkul sir aapka video bahut hi helpful hai.
      Plz above topic pe bhi video banaiye.

  • @zishan396
    @zishan396 Рік тому

    My sample titration always exceeds blank sample by this method. Y this error occurs

  • @shivamdiwakar4610
    @shivamdiwakar4610 Рік тому +1

    Good morning sir, mere pass pure sulphuric acid hai ,mujhe 98% concentrated sulphuric acid bnana hai kaise bnaye ,plz help me sir or anyone

    • @aquazoneengineering3556
      @aquazoneengineering3556  Рік тому +1

      Purity of Sulphuric acid is 98%, you don't have to do anything. It is already 98% concentrated.

    • @shivamdiwakar4610
      @shivamdiwakar4610 Рік тому

      @@aquazoneengineering3556 okey thank you so very much sir

    • @shivamdiwakar4610
      @shivamdiwakar4610 Рік тому

      Sir stp me COD ke liye 150 temp rkhte h for 2 hour but hmare COD digester me 100 tk hi temp h toh kitna temp rakhe ham

  • @Digital_Guidance
    @Digital_Guidance 2 роки тому +1

    Dm water kya hota hai sir ne bataya tha 3:30 seconds par koi batayega?

    • @aquazoneengineering3556
      @aquazoneengineering3556  2 роки тому

      De-mineralised water, aisa water jisme TDS less than 0.9 ho. And conductivity 1.2 .

  • @chukwumaonyeka29
    @chukwumaonyeka29 Рік тому

    Please, how is sample dilution 10?

  • @bhavikamehta1434
    @bhavikamehta1434 9 місяців тому

    Kya iske reference ka link bhi upload kar sakte hain please?

  • @sandeepatiketi1268
    @sandeepatiketi1268 8 місяців тому

    Why ...we take 8000....what is it's mean

  • @chavdaharesh-vo5mv
    @chavdaharesh-vo5mv Рік тому

    Blenk 24.25 no vche Avu jove evu kaik hoi chhe

  • @mrmaniar1555
    @mrmaniar1555 2 роки тому +1

    What if we don't heat for 2 hour so the results will be higher or lower than actual results

    • @aquazoneengineering3556
      @aquazoneengineering3556  2 роки тому +1

      Could be any of them, most of the time it may show higher then actual, because digestion would not take place properly.

    • @mrmaniar1555
      @mrmaniar1555 2 роки тому

      @@aquazoneengineering3556 thanks bro I have doubt now cleared basically I am ETP and ro incharge what about u

  • @thakurduttsharma705
    @thakurduttsharma705 3 роки тому

    Each single point understand clearly

  • @dartahir6090
    @dartahir6090 2 роки тому

    Sir can you tell me which sop followed for COD determination , I want to know that sop

  • @oumnourhadj4221
    @oumnourhadj4221 Рік тому

    thank you so much ,but measure of sécurité out , normalement sous haute chimique il y'a un risque pour votre santé

  • @sheshnishad9803
    @sheshnishad9803 2 роки тому

    Sir Benzyle salicylate acid value
    Method and farmula

  • @dhananjayk130
    @dhananjayk130 Рік тому

    5 ml potassium dichromate Pipette se kyu nahi dala

  • @chakrigollapalli6062
    @chakrigollapalli6062 2 роки тому +1

    8000 is f.a s factor sir

  • @bhanu_sangita
    @bhanu_sangita 2 роки тому

    USBR technology ka video upload kijiye sir

  • @hiddenstr4098
    @hiddenstr4098 2 роки тому +1

    aap 98% h2so4 without hand gloves addition kar rahe ho or pure video me aapne kaha bhi hand gloves nahi pehna.
    #safetyfirst
    aapko lab safety ke bare me padhne ki jarurat hai..
    ye video ko dekh ke lab chemists per galat impact aa sakta hai.

  • @dilipparihar279
    @dilipparihar279 7 місяців тому

    Mughe sikhna h

  • @chavdaharesh-vo5mv
    @chavdaharesh-vo5mv Рік тому

    Hi

  • @rakeshbeniwal6505
    @rakeshbeniwal6505 2 роки тому

    Complete test BOD parameter video uploaded sir