Godiva Prima: Vehicle mounted Fire Pump test.

Поділитися
Вставка
  • Опубліковано 27 січ 2025

КОМЕНТАРІ • 14

  • @serpepintiati7734
    @serpepintiati7734 27 днів тому

    My pump is not increasing pressure

  • @GlenB1989
    @GlenB1989 Місяць тому

    Can you explain what happens when you select high pressure on the crossover? Does it just open a valve or does it actually start the high pressure pump spinning?

    • @truck-tek
      @truck-tek  Місяць тому +1

      It diverts the water flow through a restriction , causing high pressure with a lower volume of water. This is governed by a 50bar safety valve which opens if pressure exceeds 50bar. This happens whilst also making low pressure at a high volume. This is a 2 stage pump. World series twin 3010.
      3000 ltr of water per min at 10 bar (low-pressure)

    • @GlenB1989
      @GlenB1989 Місяць тому

      Thanks for the reply.

  • @captainotto
    @captainotto Рік тому

    Are you able to pump saltwater with those pumps? LP impeller is Aluminium but the rest of the pump is stainless. That should mean corrosion issues.

    • @truck-tek
      @truck-tek  Рік тому +1

      Yes you're correct. We don't pump from salt water as nowhere near the sea. It would work if you did but would have to flush out with fresh water after and not advised. The LP impeller is cast aluminium the HP is stainless and the body is aluminium.

  • @jarydwilson6706
    @jarydwilson6706 Рік тому

    Can you confirm where the primer hose attaches to please, is it attached to the inlet manifold behind the collector head or does it attach somewhere different? A diagram would be great. Cheers

    • @truck-tek
      @truck-tek  Рік тому

      By primer hose do you mean the suction hose to pull water from a open source or what actually creates the vacuum?

    • @jarydwilson6706
      @jarydwilson6706 Рік тому

      @@truck-tek thanks for replying - i mean the hose coming from the primer that attaches to the priming port. Where is the priming port located?

    • @jarydwilson6706
      @jarydwilson6706 Рік тому

      @@truck-tek the Prima 4010 has a reciprocal primer fitted behind the pump, this has 2 red hoses that attach to the pump to remove air from the casing, im trying to work out if they attach to the discharge side of the pump or the inlet side of the pump?

    • @truck-tek
      @truck-tek  Рік тому +1

      @@jarydwilson6706 this is a 3010 with prima primers that run on a electro magnet clutch.
      they are mounted either side and join to a check valve to the rear of the pump via a hose each side.
      This valve is then mounted to the low pressure side which sucks the air from the casing. I'll try get a pic if it lets you upload them on here.

    • @jarydwilson6706
      @jarydwilson6706 Рік тому

      @@truck-tek Thanks again for your reply, that would be great. Cheers

  • @ranjesekoistiawan8901
    @ranjesekoistiawan8901 Рік тому

    what is the solution if the suction power of the pump is weak or not strong enough?

    • @truck-tek
      @truck-tek  Рік тому

      if it isnt making vacuum to pull from open water
      It has a Vax leak somewhere
      Usually the piston primer seals are split
      Or it's drawing in air from.somwhere