  • @tommysteele615
    @tommysteele615 10 місяців тому +31

    Just note. In order to get all 20000watts, you have to use both of the 50A outlets. That has to feed 2- double 50A breakers in a sub panel via 6awg wire. Then from sub panel you feed your main panel to a 100amp breaker via 2awg. This gets you all of the 20000 watts. Using 1- 50A outlet only gets you 12500 watts.

    • @kevinanglin678
      @kevinanglin678 8 місяців тому

      Is this how you have yours wired up?

    • @danduv1
      @danduv1 7 місяців тому +2

      If my generator has a 50A and 30A, could I do this with the corresponding 50A/30A breakers in subpanel and 80A in main?

    • @joshsinglefooter
      @joshsinglefooter 2 місяці тому

      So what you're saying is the 12,500 powered his house. Basically, it did it with one hand behind its back. That what you're saying?

    • @lawjilei
      @lawjilei 19 днів тому +1

      Finally someone presents a solution

    • @dontbanmebrodontbanme5403
      @dontbanmebrodontbanme5403 5 днів тому

      Btw, technically, you could just feed the two 50A outlets to two 50A breakers in the main panel, but then you'd be able to mechanically backfeed power to the utilities. The way tommysteele615 describes it, since the subpanel would be feeding only 1 100A breaker, you can safely make sure that only that breaker or the main breaker is on and not both, using an interlock kit.

  • @SuperRobkar
    @SuperRobkar 2 роки тому +5

    That generator is a beast. When you install that soft starter it won’t even blink.

  • @israelgriffin585
    @israelgriffin585 2 роки тому +13

    Make sure you treat the fuel and turn the fuel switch off to let the generator shut down on its own. That will clear the fuel in the carburetor. Then turn off the power switch. Be blessed and a blessing Amen.

    • @0409jd
      @0409jd Місяць тому +1

      Also a good idea to let it run at idle for 10 min or so after being on a load to let it cool down, then turn off the fuel to bleed the carb.

  • @heimdallblows179
    @heimdallblows179 Рік тому +4

    Looking forward to your more in-depth on this beast. I am pretty much sold on the Genmax GM9000iED but this thing is really making me think. I have planned on gettin 2 Genmax and running them in parallel. That would get me by with not much extra. But the WGen20000 would power my house and I have another 50 amp line to help others out. Thank you for all you do!

    • @donelias1981
      @donelias1981 Рік тому

      I’m battling the same dilemma, I am worried about my electronics as I just had to replace a 75in TV that was only a few years old. I’m unsure if it was just a normal failure or caused by the few times we lost power and had back up for an extended period of time. Was just about sold on the GENMAX 9k which matches the Westinghouse I have now but been thinking of upgrading to a larger unit.

  • @defjamsgreen
    @defjamsgreen 2 роки тому +5

    YOU HAVE A SUPER GENERATOR AND AT 28000 WATTS , IT IS A BEAST . AWSOME VIDEO .👍👍🤗

  • @jamesprice34120
    @jamesprice34120 Рік тому +2

    I have this generator on order. My house is fully electric and uses a lot of power. The 83 amp circuit breaker is the main breaker.

  • @patrickcoleman5867
    @patrickcoleman5867 Рік тому +8

    What about part 2 show more of this monster. I sold my Generac 17500 and ordered this generator. Less then 5% THD is a game changer.

  • @Tom-In-Ga
    @Tom-In-Ga 2 роки тому +8

    I'll never need something like that but that was a great demo! Very entertaining.

  • @yonathanevan3334
    @yonathanevan3334 11 місяців тому

    Perfect design snd and power for large camper.

  • @rockystelone21
    @rockystelone21 2 роки тому +4

    That's a beast of a portable generator.

  • @utubetjc
    @utubetjc 2 роки тому +2

    Thanks Gavin. Very impressive review as expected!

  • @garden-queen2393
    @garden-queen2393 2 роки тому +2

    Amazing 👍. Great job thanks.

  • @jamesappling1212
    @jamesappling1212 Рік тому +1

    Big Dog for the Big Jobs, add a little Puppy on the side for the light work. (Small fuel saver generator or Solar for light duty situations).

  • @DIYRAYMOND
    @DIYRAYMOND 11 місяців тому +6

    I just ran my 5 ton 14seer AC unit with my predator 8750 ran it with no problem. I turned off all the other breakers while we ran the AC. Then when we were satisfied with the temperature we turned it off and ran the other breakers.

  • @jeffreypinder9398
    @jeffreypinder9398 Рік тому

    You have solar as well, you are def covered for power for the worst of weather. Great job, Gavin.

  • @SouthPawEd
    @SouthPawEd 2 роки тому +6

    I just got this generator delivered on Friday. I have it setup with 2, 50amp inlets--1 for each of my 2 panels. We have 2, 2.5 ton units. I don't know if I'll be trying to run both at the same time though. That 5 ton pulled her right down. Definitely a stout unit.

    • @busterhyman6633
      @busterhyman6633 Рік тому

      can you back feed two panels simultaneously

    • @SouthPawEd
      @SouthPawEd Рік тому

      @Buster Hyman Yes. I was able to power both panels and run both a/c units plus lights/ceiling fan/tv. I want to get some meters to see how much power we're using, but for all intents and purposes, it "powered my house."

    • @brucewillis7135
      @brucewillis7135 6 місяців тому

      ​@@SouthPawEdcan you use two separate generators two power those panels

    • @SouthPawEd
      @SouthPawEd 6 місяців тому

      @@brucewillis7135 This is the only portable generator that I have seen that puts out more than 50 amps, and that's only because it has 2, 50 amp outlets that put out 50 amps each. I haven't seen any portable generators that provide more than 50 amps from a single outlet, nor have I seen power cables that could handle more than 50 amps, so I don't think that I could fully-power each panel, even with 2 generators. These panels are each 100 amps, and as it is, I feed them 50 amps each. This more than powers anything that we need, short of running the washer, dryer, dishwasher, and heating systems simultaneously.

    • @SouthPawEd
      @SouthPawEd 25 днів тому

      ​@brucewillis7135 I suppose if nothing on those panels overlapped, you could use 2 generators. On mine, the downstairs condensing unit is on panel A and the downstairs air handler unit is on panel B. The upstairs system is divided similarly. I was advised by my electrician to power both panels with my one generator.

  • @sshvulnerability
    @sshvulnerability 5 місяців тому +1

    You can put a soft start kit on the hvac compressor so it doesn't pull that much power on start up.

  • @christophersustayta5974
    @christophersustayta5974 Рік тому

    Excellent excersize !

  • @clintondoner1133
    @clintondoner1133 4 місяці тому +1

    THE BEAST!!! My 4,400 name starts with a B and it is not beast!!! Great Show!!!

  • @CycleST1300
    @CycleST1300 2 роки тому +7

    What a beast! I don't believe I'd want to feed it though, uses about 1 1/2 gallons per hour at 50%.

    • @shanew7361
      @shanew7361 2 роки тому +12

      I agree especially with Biden gas prices.

    • @lifeenglightment7977
      @lifeenglightment7977 Рік тому +5

      You will wish to have when the time comes. You’re not buying it due to the gas price; you obtain it because it ensures you the peace of mind for the rest of your family. You can not stop the natural disaster, but you can work really smart to minimize the impact.

    • @SouthPawEd
      @SouthPawEd Рік тому +4

      It's something like 11hrs on 17gal @ 50% load. However, 50% constant load is *a lot* for this generator. I got this unit a little more than a year ago and had to run it one night. Ran it for about 9hrs on just under a half tank of fuel. It ran a few lights, a tv, and my 2, 2.5 ton hvac units. For about 7hrs of that 9hrs, we were sleeping, so only the hvacs ran.

  • @OptimalTraining
    @OptimalTraining 2 роки тому +22

    With that generator you could power two houses

    • @leoschneider3570
      @leoschneider3570 Рік тому +5

      I purchased one, and one time for an extended power outage I ran one of the 50 amps to my neighbor’s house

    • @tw9433
      @tw9433 10 місяців тому +1

      I’m guessing it’s crazy loud though? I want an inverter for the quietness but love the idea of having that much power with this big boy

    • @user-ui4iv8dz3w
      @user-ui4iv8dz3w 10 місяців тому

      2 you mean 4.

    • @OptimalTraining
      @OptimalTraining 10 місяців тому

      @@user-ui4iv8dz3w , True I guess you could power four houses. 😃

  • @shanew7361
    @shanew7361 2 роки тому +3

    Great video 🇺🇸🙏💪

  • @jonlee5642
    @jonlee5642 2 роки тому +1

    Gotta do a whole house test with the duromax trifuel! Has a less then 5% tbd

  • @JM-fm7dy
    @JM-fm7dy 2 роки тому +6

    Hey Gavin, I have this gen hooked up to are house with two 50amp rv cords to run are 5ton geothermal no softstart, well pump for the geo and the frigerator. Only this i dont like about this generator is it only has an 83 amp main breaker for its distribution panel. Which is only good for 19920watts @ 240v. Each 50amp cord is only good for 12000. We can almost kill the gen out if the well and the geo turn on at the same time.

    • @GeneratorReviews
      @GeneratorReviews  2 роки тому +3

      Wow!!! you pull some serious power my friend I like that you hooked up each leg with its own 50amp plug

    • @raybees72
      @raybees72 2 роки тому +2

      My God, What's your Power bill run monthly?

    • @JM-fm7dy
      @JM-fm7dy 2 роки тому +2

      @@raybees72 its like $240 a month on average for really bad insulated 1900 square ft, 1960 built house and everthing in are house is Electric.

  • @tonyd3266
    @tonyd3266 Рік тому +1

    Property 1: FL: The more I watch these videos, the more I like the idea of a generator under $800 and a $200 walmart window AC unit that runs on 110v. (im in FL so not concerned with the high KW for heating). not having natural gas on property is a huge limit locally. Property 2: I have free "dirty" natural gas - in a rural area with mining and frequent power outages for 6h-3d, at least 3 times a year. there we do have freeze warnings. Anyone else running a dirty nat. gas line off a wellhead into one of these ? what, if anything, do you put inline to filter water/etc and regulate pressure?

  • @athenanimbuss6826
    @athenanimbuss6826 2 роки тому +7

    We need something like this as a backup tothehouse. It is about the same price as a whole house generator but save you about $10 - $15k on the install 👍❤️🙏

    • @GeneratorReviews
      @GeneratorReviews  2 роки тому +4

      Plus you need to get a permit and neighborhood association approval for those you’re talking about this one when you move you could take it with you or sell it
      Thanks for watching thanks for subscribing👍🏾😊💯

    • @athenanimbuss6826
      @athenanimbuss6826 2 роки тому

      @@GeneratorReviews Good info!👍❤️🙏

    • @athenanimbuss6826
      @athenanimbuss6826 2 роки тому

      @@johnjohnssouthernexposure5421 Nice 👍❤️🙏

    • @robertduncan2742
      @robertduncan2742 2 роки тому +5

      When the powers out all the things needed won't be needed such as permits or neighbors approval or HMO fees everyone will be asking you to hook theres into your for power. That's why I'll never live in those areas. The gen looks great and a great review

    • @SouthPawEd
      @SouthPawEd Рік тому +2

      That's why I bought this one over a true back-up generator. For $2,500, I had both of my panels wired up, so that's the only cost I'd leave at my house if/when we ever moved since the gen can come with us. Compared to sinking all that cost in a stand-by unit that would probably be left with the house during a move.

  • @richardmccoy8628
    @richardmccoy8628 Рік тому +1

    That was awesome. What all do I need to run the house? I have a 50 amp plug. Already coming out of my box with a 200 amp.

    • @GeneratorReviews
      @GeneratorReviews  Рік тому

      The very first thing you need to do is install a soft start on your compressor then you’re gonna need a 9000 W generator

  • @brandonmurphy4657
    @brandonmurphy4657 10 місяців тому

    I run everything in my home on a 7000/10.5 geni . Including two mini split units

  • @jonlee5642
    @jonlee5642 2 роки тому

    Check out the microair softstart

  • @anthonyb1426
    @anthonyb1426 Рік тому +1

    Question for you, I am also considering getting this generator but with that 50 amp Inlet isn’t that only capable of moving roughly 12,000W? So do you have some sort of special set up that you’re utilizing the rest of that generator power?

    • @GeneratorReviews
      @GeneratorReviews  Рік тому +2

      12500W on the 50amp inlet box, you can still use the plugs on the generator or wire each leg to its own 50amp plug or two inlet box

  • @billdee814
    @billdee814 Рік тому

    This big generator maintains 60Hz.. perfectly during loads. My 12000 Druamax on propane fluctuates between 58 and 60 while running my 120volt microwave.

    • @theMister07
      @theMister07 Рік тому

      Time to level up or switch to a brand like Champion that can handle the pressure

  • @carlwheeler3403
    @carlwheeler3403 Рік тому +3

    The max output in that configuration is going to be 12kw (50amp * 240volts = 12kw)

  • @westinghouse
    @westinghouse 2 роки тому +1

    Thanks for sharing!

    • @GeneratorReviews
      @GeneratorReviews  2 роки тому +1

      Thanks for watching
      Looking forward to future collaboration with you.

    • @joeriddell1
      @joeriddell1 Рік тому

      @Westinghouse can you explain how (and if) you can run two cords out of the 50 amp outlets into 1 200 amp house panel? Thanks!

  • @StrongManMattt
    @StrongManMattt 2 роки тому +2

    you do any videos with any of the Echo generators yet?

    • @GeneratorReviews
      @GeneratorReviews  2 роки тому +2

      Not yet but I will get one soon thanks for recommending it

  • @drdexter33
    @drdexter33 Рік тому

    Nice demo!. Just wondering if there's a duel-fuel (propane) version of this model.

    • @GeneratorReviews
      @GeneratorReviews  Рік тому +1

      Thanks! I’m sure there will be a kit for it soon to convert to tri fuel

  • @mdunbar04
    @mdunbar04 2 роки тому +4

    Make sure u do a video of the soft start installation

  • @HappyHands.
    @HappyHands. 2 роки тому +1

    Sorry if you said and i missed it... But what was the total wattage and average amperage use when you had everything on?

    • @GeneratorReviews
      @GeneratorReviews  2 роки тому +1

      Sorry but I didn’t focus this test on the watts used I will add the meter on the next one.

  • @Kyle5371
    @Kyle5371 Рік тому +1

    I just ordered one of these generators. I would like to have an auto transfer switch.
    My question is what parts do I need to have this fully installed. A full parts list would be very helpful.
    Any advice on parts or brands is helpful.
    Thank you for you time and knowledge.

    • @GeneratorReviews
      @GeneratorReviews  Рік тому

      Hey Kyle
      Get your Inlet box kit plus lock out kit your 50 amp power cable I would say around 25 feet you’ll be all set.

    • @Kyle5371
      @Kyle5371 Рік тому +1

      Would I get two so I can run the full 100 amps?

  • @mikemurray8423
    @mikemurray8423 2 роки тому +1

    I want to see the 9000 w gen power the ac with the soft start, or do you need two in parallel, and what about that 23% vs 5% harmonic?

    • @GeneratorReviews
      @GeneratorReviews  2 роки тому

      Definitely less than 5% is acceptable anything more I don’t run it. I think the 9000 will power with the soft start no problem. The thing you have to consider is you never know when the AC is going to kick on, so you might be running the microwave or washer and dryer and then the AC decides to kick on and over load the generator.
      Thanks for watching thanks for subscribing

    • @modemer
      @modemer 2 роки тому

      If you are referring to my post about the 23% harmonics, I found my mistake when I looked it up. THD is 5%.

  • @Randy-vk7pj
    @Randy-vk7pj Рік тому

    Gavin, would a Westinghouse 15kw dual fuel generator be powerful enough to run a house with a 3.5 ton and 2 ton split ac units? Not interested in a stand-by generator because I want the ability to move the generator to different location if the need arises. The 27 kw you tested is out of stock but the smaller duel fuel 15 kw is available. I like the ideal of powering my entire house if that need ever arises.
    Thanks, Randy

    • @GeneratorReviews
      @GeneratorReviews  Рік тому

      I would recommend you make sure it puts out a pure sine wave before powering the central A/C

  • @Randy-vk7pj
    @Randy-vk7pj Рік тому

    Do you have to worry about the generator damaging sensitive appliances because it is not a inverter style power source?

    • @GeneratorReviews
      @GeneratorReviews  Рік тому +3

      This model actually has less than 5% THD it’s not like the other construction style which has over 25% THD
      So it actually puts out pretty clean power and it’s pure sine wave

  • @patrickcoleman5867
    @patrickcoleman5867 Рік тому +1

    Omg this has a pure sine wave and a THD of 5 do the still make this I can’t find it anywhere I would sell my Generac 17,000 and get this

  • @seymourscagnetti1413
    @seymourscagnetti1413 Рік тому

    This is one serious machine. It sounds like a municipal power sub-station coming online. Quick question Gavin, do you know if anyone manufactures a "V-TWIN" powered inverter generator? Thanks.

    • @GeneratorReviews
      @GeneratorReviews  Рік тому

      It does sound like that but it’s an awesome generator, that’s a great question I don’t know any V twin inverter generator🤔

  • @crazygravy437
    @crazygravy437 2 роки тому +1

    Nice Video. I just purchased this generator and awaiting shipment. I’m looking for a power inlet box but all the highest related wattage I can find is around 12,500 watts. Is your inlet box rated for 28kw or will it be ok to use one rated 12.5kw with this generator?

  • @mkvinsley3848
    @mkvinsley3848 Рік тому

    This was a great video! Learned a lot. Could I install 2 inlet boxes and wire each to a single 200 amp breaker box with each going to a 50 amp generator breakers to utilize the full 20k capability?

    • @GeneratorReviews
      @GeneratorReviews  Рік тому

      That’s a good idea. You probably have to talk to your electrician see if that’s possible.

    • @user-ui4iv8dz3w
      @user-ui4iv8dz3w 10 місяців тому

      Or run a line to your neighbor so y’all can share the cost of a 3k generator.

  • @MrPatdeeee
    @MrPatdeeee Рік тому +1

    I agree with you kind Sir @ time 2:43; where you said, "You don't have to do this". Which is break all the circuits \ in the panel. And it really has never been that; with the larger Generators these days.
    And even it does not need, or IF you are NO using/or turned off those users; in the large amp users. Which I feel is the best way to transfer in small Generators.
    So, for with this BIG Generator; NOTHING will happen in 99.9% of the times when you leave the circuits on. And think about this. How many times has lightning killed the power and then it comes back on. So there is NO difference. For most ALL big users; of amps; have electronic protectors; for fast on and off power.
    This is: in most ALL thermostats and/or the A/C's for many years; to protect A/C's, freezer's, Icebox's and etc! For what it's worth.

  • @user-wm5bu5ey2k
    @user-wm5bu5ey2k Рік тому +1

    I'm new to this generator stuff but have questions.
    With the Westinghouse 20kw... 1 - 50amp plug is limited to 12000 watts (correct? )
    Could you connect both 50 amp from the generator to the gome panel to achieve the full potential of the generator? Would that be considered parallel like with the inverter type generators?

    • @GeneratorReviews
      @GeneratorReviews  Рік тому +1

      It would not be paralleling, but that is something you can do

    • @user-wm5bu5ey2k
      @user-wm5bu5ey2k Рік тому

      @@GeneratorReviews I appreciate the info. Thanks

  • @AndTodaysProjectIs
    @AndTodaysProjectIs Місяць тому

    Any idea how many gallons per hour that thing is drinking at anywhere around half load? I may be in a situation where I will not be able to install a whole home permanent generator I found a solution So I might need to rig something like this up to power a rather large home with two air conditioners. One problem we have during hurricanes is typically gas supply. Wondering how many gallons per hour of the same drinks

    • @GeneratorReviews
      @GeneratorReviews  Місяць тому

      This generator uses an estimated 1.56 GPH (gallon per hour) at a 50% load

  • @alnett22
    @alnett22 7 місяців тому

    What's the specifications for the fuel needed for the generator? Will I do fine on 87 octane 10 percent ethanol

    • @GeneratorReviews
      @GeneratorReviews  7 місяців тому +1

      Yes, you can run 87 octane 10% ethanol with some fuel treatment added especially if you’re going to store it that way but I recommend you to drain the complete tank and carburetor before storing.

  • @dadsworld5084
    @dadsworld5084 Рік тому

    When you are at full load, are you using just the 50 amp cord, just wondering how so much can run off it, I currently run a small one then yours and thinking of upgrading currently at 13k but runs the whole house minus AC at once, I can run AC but need to turn off some things dues to surge

    • @GeneratorReviews
      @GeneratorReviews  Рік тому

      That was only a quarter of its output. This generator is so powerful

    • @dadsworld5084
      @dadsworld5084 Рік тому

      @@GeneratorReviews so you can run all that off one 50 amp cord wow

  • @ericneidig2792
    @ericneidig2792 Рік тому

    But isn't the AC on a 60 amp breaker? Just cause it'll run it doesn't mean it won't damage motor long term. Also 50 amp cord has max wattage of 12.5 kw. I have similar set up.

  • @Noneofyourdambusssiness
    @Noneofyourdambusssiness 5 місяців тому

    Gavin, I have truly learned a lot by watching your videos. This was the first time I've seen anyone with solar PV shut off RSD before running this type of test. In other videos, you dont show yourself doing so. Is your PV system grid tied and without batteries?
    I have a 19.5 system with no batteries. Im considering doing exactly what you have done with interlock, inlet box, and generator for longer outtagr backup. I will use DPU for shorter. Is there any danger of genrator getting back fed if you dont shut off the RSD? Just trying to ID all possible issues. Thank you and keep up the great work.

  • @donelias1981
    @donelias1981 Рік тому

    How is the power coming from this generator compared to an inverter such as the 9000 watt inverters out there? I want to protect my electronics with clean power but would also like to run my AC.

    • @GeneratorReviews
      @GeneratorReviews  Рік тому +1

      This is a pure sine wave generator but it’s not as quiet as the inverter 9000w because of eco mode

    • @donelias1981
      @donelias1981 Рік тому

      @@GeneratorReviews so the low idle switch is not the same as ECO mode? Or does the sound just because the open air vs enclosed generator? Would you recommend the GENMAX over this for a residential backup generator? A 9000 GENMAX matches the Westinghouse WH7500E in power output that I have now just want cleaner safer power to my TVs and such.

  • @mr.boniato6402
    @mr.boniato6402 11 місяців тому +1

    Have you thought of using a soft start or smart start? I hesitate to buy due to bad Amazon reviews.

    • @GeneratorReviews
      @GeneratorReviews  11 місяців тому

      I do have a soft start installed.
      ua-cam.com/video/KjGc7fz3D8c/v-deo.htmlsi=rxU82xXPkD4KT7WE

  • @alejandrocarrillo373
    @alejandrocarrillo373 Рік тому +1

    What was the total watts, when everything was on in the house?

    • @GeneratorReviews
      @GeneratorReviews  Рік тому +1

      I only pulled 7000 W not even close to what this generator can handle I could’ve hooked up another house

  • @davidyummus6259
    @davidyummus6259 2 роки тому +6

    Aussie Dave in PA here Gavin,... What Soft Start unit would you recommend ?

    • @GeneratorReviews
      @GeneratorReviews  2 роки тому +4

      I’ll be installing the micro air easy start

    • @alejandrocarrillo373
      @alejandrocarrillo373 2 роки тому +1

      @@GeneratorReviews with the soft start installed, will you be be doing the test with one 9000? Genmax or Predator?

    • @GeneratorReviews
      @GeneratorReviews  2 роки тому +3

      @@alejandrocarrillo373 yessir I will definitely be doing that👍🏾

    • @davidyummus6259
      @davidyummus6259 2 роки тому +2

      @@GeneratorReviews
      Thanks 😏

  • @Ben275353
    @Ben275353 Рік тому +1

    Can you parallel the 2 50 amps to 1 100 amp for a home?

  • @enriquesosa3270
    @enriquesosa3270 Рік тому

    What amp breaker did you use in your panel for the generator?

  • @TheSnakeman3
    @TheSnakeman3 2 роки тому

    Looking forward to the Easy Start on the AC and a test with a smaller Gen.
    When running a house, does it have to be an inverter Gen? I got a 8750 watt that’s not an inverter Gen.

    • @GeneratorReviews
      @GeneratorReviews  2 роки тому +2

      Hey Robert
      I would be very hesitant to run a non-pure sine wave inverter on my house with all of your electronics and computer systems

    • @TheSnakeman3
      @TheSnakeman3 2 роки тому

      @@GeneratorReviews is there any way to turn it into a sine wave output?

    • @GeneratorReviews
      @GeneratorReviews  2 роки тому +1

      @@TheSnakeman3 it’s a sine wave power already

    • @GeneratorReviews
      @GeneratorReviews  2 роки тому

      @Justin Time you are absolutely right but 90% of modified sine wave power is dirty and will eventually cause more problems than its worth

  • @carlcapello9956
    @carlcapello9956 2 роки тому +1

    This is the first 20000 watt generator I have seen and it's by Westinghouse that is awesome power for your entire house. If you don't mind me asking, what is the financial damage to your wallet? Did you have this running on gasoline or propane?

    • @GeneratorReviews
      @GeneratorReviews  2 роки тому

      When I bought this one I paid around 3k now it’s doubled in price it’s a gas only Gen

    • @carlcapello9956
      @carlcapello9956 2 роки тому

      @@GeneratorReviews That is a good price and I just found out they have a sale on models they want to get out the door sometimes.

  • @shanedeal2356
    @shanedeal2356 2 роки тому

    Turn on stove and oven also

  • @wow1022
    @wow1022 2 роки тому +2

    damn, you'd need 2 50A inlets to fully utilize the power out of this generator

  • @tonyaguilar0626
    @tonyaguilar0626 Рік тому

    Buying this!! What size 50 amp cord do I get? On Amazon all the 50 amp generator cords say max 12500 watts but this is a lot more. Thanks

    • @GeneratorReviews
      @GeneratorReviews  Рік тому

      It has two 50 amp plug

    • @SouthPawEd
      @SouthPawEd 25 днів тому

      I bought 2, 6 gauge cords from Generac. I wouldn't go cheap on the cables

  • @blakeloke6997
    @blakeloke6997 19 днів тому

    Thank you for the video Gavin. I just ordered the same machine through Amazon (it hasn't arrived yet). When reading the details more thoroughly, I found that the frequency output is 50Hz instead of 60Hz. Your meter shows 60Hz on the unit connected to the house. Did you have to adjust the run speed and frequency settings to get 60Hz?

    • @GeneratorReviews
      @GeneratorReviews  18 днів тому +1

      It’s 60 Hz don’t worry that was a typo on Amazon

    • @blakeloke6997
      @blakeloke6997 18 днів тому

      Thank you. I was worried as Amazon wouldn’t cancel. Then more research and found the Operating Manual online. It says 60Hz

  • @cobbetlprogrammer1344
    @cobbetlprogrammer1344 Місяць тому

    Wow! Totally Awesome: Does this run on propane too? How much does one of these Bad Boys go for? Thanks Much!

  • @peterfrancis3865
    @peterfrancis3865 11 місяців тому

    Thanx nice✅

  • @rcprod9631
    @rcprod9631 Рік тому

    You mention a "soft start" at the beginning of the video. (I may have spelled it wrong) Would you mind explaining what that would be for? Thanks.

    • @GeneratorReviews
      @GeneratorReviews  Рік тому +1

      The soft start helps to run the central A/C using a generator by lowering the power needed to start the compressor
      ua-cam.com/video/KjGc7fz3D8c/v-deo.html

    • @rcprod9631
      @rcprod9631 Рік тому

      @@GeneratorReviews Thanks for the helpful link. Just subscribed.

    • @GeneratorReviews
      @GeneratorReviews  Рік тому +1

      @@rcprod9631 Thanks for the Subscribe and you’re welcome glad to help 👍🏾😊

  • @lowriderssux
    @lowriderssux 11 місяців тому

    Hey Gavin, how did the sine wave output look on this generator?

    • @GeneratorReviews
      @GeneratorReviews  11 місяців тому

      The sine wave looked OK as long as the generator was not in the low idle mode

  • @lordnetsplits3192
    @lordnetsplits3192 Рік тому +1

    Could you do a THD test on this generator.

  • @markbennett7826
    @markbennett7826 2 місяці тому

    What is 20000 gen fuel usage vs 12500 Westinghouse gen; or know; need extra output?

  • @Redtale1106
    @Redtale1106 Рік тому

    How big is the tank and how long can it run on gasoline?

    • @GeneratorReviews
      @GeneratorReviews  Рік тому

      This generator has 17 gallons tank with a fuel capacity of 17.17 gallons, the WGen20000 may run for around 11hours at 50% load with a full tank (fuel consumption around 1.56 GPH).

  • @davidwho8215
    @davidwho8215 Рік тому +1

    You probably need two generator inputs to your house, as pushing 20Kw through a single NEMA 14-50 is over it’s rated limit. I noticed the generator had two NEMA 14-50 plugs, probably for that reason.

    • @GeneratorReviews
      @GeneratorReviews  Рік тому

      Yes you’re right.

    • @joeriddell1
      @joeriddell1 Рік тому +1

      @@GeneratorReviews Awesome video! Thanks for posting! can you explain how (and if) you can run two cords out of the 50 amp outlets into 1 200 amp house panel? Thanks!

  • @Randy-vk7pj
    @Randy-vk7pj Рік тому

    Why do these large generators don't offer tri- fuel options?

  • @evisin77
    @evisin77 Рік тому

    I like this machine but at the price why not just get a ganarac stand by?

    • @GeneratorReviews
      @GeneratorReviews  Рік тому +1

      After installation and permits, I’m pretty sure you would triple the cost of this one

  • @DjCorona080910
    @DjCorona080910 23 дні тому

    Do you know how much natural gas it uses per day?

  • @Tobinator76
    @Tobinator76 8 місяців тому

    Have you changed the oil yet? What oil filter did you buy?
    I can't find the oem filter anywhere

    • @GeneratorReviews
      @GeneratorReviews  8 місяців тому

      You don’t have to use the oem filter just take it to your auto parts store and find a replacement it’s just an oil filter.

    • @SouthPawEd
      @SouthPawEd 25 днів тому

      ​@GeneratorReviews Came here to ask the same question. Westinghouse's part number 329908 doesn't help anything. The oem filter has no numbers on it. Just spent 30min at the store with the tech looking around. There's a forum that had a comment where the Fram PH4967 and the WIX 51394XP both fit. The Fram is stubby compared to the oem. Going to look for the WIX next.

  • @tommyb2616
    @tommyb2616 Рік тому

    What meters are those that you put on each leg in the diy box?

    • @GeneratorReviews
      @GeneratorReviews  Рік тому

      This is the video I showed how I made it and if you look into the description you’ll find all the links to everything you need on Amazon

    • @tommyb2616
      @tommyb2616 Рік тому

      @@GeneratorReviews you forgot to post the link😎

  • @lesruth2756
    @lesruth2756 2 роки тому

    Question. How come the 50 amp breaker didn’t trip with the 59 amp start up power draw?

    • @wow1022
      @wow1022 2 роки тому

      household breakers operate on a time overcurrent curve which is an inverse curve, as current increases above the pickup the trip time decreases

    • @lesruth2756
      @lesruth2756 2 роки тому

      @@wow1022 Reason I asked is because I plan to purchase a 15,000/12,500 Generator to run everything possible in my 3,000 sqft home. I also have a 5 ton AC unit but I’ve been told it won’t work because both the AC & handler are both 50 amp breakers and the 50amp generator will not power both??

    • @GeneratorReviews
      @GeneratorReviews  2 роки тому

      It didn’t trip because a 59 amp at 240v is only 29.5 amp on each leg.

    • @wow1022
      @wow1022 2 роки тому

      @@lesruth2756 a 12000/15000 probably won't get the AC started on the 5 ton unit without a soft starter, remember that the breaker protects the circuit and not the load, just because it is 50A circuit doesn't mean it's a 50A load, you need get a clamp meter to see how much current draw your AC and water heater pull, usually they size the AC circuit significantly above the actual load because of start up current and circuit length, my 3 ton unit pulls 12A on a 30A circuit

    • @lesruth2756
      @lesruth2756 2 роки тому

      @@wow1022 So what about the air handler blower do you think the two can be powered together on this particular generator?

  • @Durango214
    @Durango214 2 місяці тому +1

    I just hook up the inlet box. But once I turn the breaker on. No power is transferred. Yes the main is off

    • @GeneratorReviews
      @GeneratorReviews  2 місяці тому

      Make sure all your circuit breakers on this generator are on.

    • @Durango214
      @Durango214 2 місяці тому

      @GeneratorReviews when I flip the circuit on .the volt reader on generator goes blank . And when I flip off it comes back on

  • @ryanyoshimura4652
    @ryanyoshimura4652 Рік тому

    Is your ac compressor a single stage?

  • @mrtjcoleman
    @mrtjcoleman 8 місяців тому

    Is your 5ton a heat pump or straight cool

  • @scottmanino7239
    @scottmanino7239 2 роки тому +1

    if you use one receptacle does that mean you can only get 12,000 watts?

    • @GeneratorReviews
      @GeneratorReviews  2 роки тому +2

      Yes but it can be wired for two

    • @joeriddell1
      @joeriddell1 Рік тому +1

      @@GeneratorReviews Awesome video! Thanks for posting! can you explain how (and if) you can run two cords out of the 50 amp outlets into 1 200 amp house panel? Thanks!

    • @joeriddell1
      @joeriddell1 Рік тому

      @@GeneratorReviews Awesome video! Thanks for posting! can you explain how (and if) you can run two cords out of the 50 amp outlets into 1 200 amp house panel? Thanks!

    • @Ben275353
      @Ben275353 Рік тому

      @@joeriddell1 I would like to know that answer also.

  • @alexgenereux4704
    @alexgenereux4704 2 роки тому

    What 50 amp power cord is this?

  • @fredyenrike198
    @fredyenrike198 23 дні тому

    What's running watts means?

    • @GeneratorReviews
      @GeneratorReviews  15 днів тому

      Running watts means what the generator can handle

  • @miiitchhh225
    @miiitchhh225 22 дні тому

    Look at all those tandem breakers, my lord is that up to code

  • @donaldjeansonne8667
    @donaldjeansonne8667 Рік тому

    Do you think a West 12000/15000w generator run a 5 ton A/C unit?

    • @GeneratorReviews
      @GeneratorReviews  Рік тому

      Yes it might start it but with a higher THD things will run hotter My computers refrigerators and even the compressor

    • @donaldjeansonne8667
      @donaldjeansonne8667 Рік тому

      @@GeneratorReviews Thanks I just concerned about the extra cost for the 20000w unit.

    • @busterhyman6633
      @busterhyman6633 Рік тому

      @@donaldjeansonne8667 The 12000/15000 is also 5% THD add that soft start kit and you will be good to go.

  • @michaelfillinger1488
    @michaelfillinger1488 Рік тому

    How many gorillas does it take to move it it's got to be heavy

  • @pstoneking3418
    @pstoneking3418 3 місяці тому

    If a 20,000 watt generator doesn't handle all loads turned on, you have a huge problem with the generator. Just start your generator and turn on the generator breaker after you've let the generator warm up.

  • @jimmie7520
    @jimmie7520 Рік тому

    Just looked At this generator…
    You have two 50 amp outlets
    At 240 volts u only produce 83.33 amps continuous.
    Different AC and heat pump systems require different amperage…having two 50 amp outlets does not give you a 100 amps continuous..
    With one transfer switch and one house breaker panel ..the most continuous amps u can feed that panel is 50 amps. So extra 50 amp plug really not much good unless u run a heavy extension cord into house to plug some 220 volt appliance in to that requires less than 33.3 amps…
    The Westinghouse 15,0000/12,000 DFc Is a way more cost effective Generator..initial cost ,option run propane , and operating cost in gas run time.
    Now if they wound make this wgen20000 with one plug that you could get 83.3 amps out off be a lot more useful and practical .

    • @GeneratorReviews
      @GeneratorReviews  Рік тому

      This generator is perfect for what it was intended for, which is construction site, you have electric concrete cutting cement, mixers, chopsaw everything connected to the generator at the same time.

    • @jimmie7520
      @jimmie7520 Рік тому +1

      @@GeneratorReviews …now that might be true …but caption says whole house generator kinda implies that it would easily take place of a home standby generator…giving you the full amperage of a 20kw unit home unit.

  • @braut34
    @braut34 Рік тому

    You didnt turn any appliances with the AC. A 9500 watts can do that.

    • @GeneratorReviews
      @GeneratorReviews  Рік тому

      With 28,000 W starting I didn’t think I would have to. I could’ve ran my whole house and my RV at the same time.😅

  • @spencerw.5195
    @spencerw.5195 Рік тому +1

    That generator is super overkill for your house if you can power everything off of a single 50A plug. If you have strip heaters in your air handler as a supplement during cold weather and they kick on, it'll trip that breaker and you'll be powering nothing. You can literally do everything you did here with a 9kw continuous, 12kw peak generator.

  • @wolverinewarlord
    @wolverinewarlord Рік тому

    No longer anywhere

  • @jvazquez53
    @jvazquez53 Рік тому +1

    If I run my whole house with 7000 watts you can run yours and you neighbors!🤣🤣🤣. Only a difference, mine run at low RPMS, therefore fuel efficiency is better...

  • @Casca-su3ty
    @Casca-su3ty 11 місяців тому +1

    I couldn't have stuff like this am the most worthless guy with mechanical things Too confusing for me.

  • @snozcocram
    @snozcocram Рік тому

    No longer on Amazon

    • @rockystelone21
      @rockystelone21 Рік тому

      Electric Direct Generator has them on sale for $3100

  • @zcar2043
    @zcar2043 Рік тому

    I don't recommend thus generator. I bought and after the first time I had to use it, the generator shuts dn randomly. It took more than a month a lot of emails ,phone calls to get a new generator. The customer service is very poor. I don't recommend to buy this generator. Buy something else.

    • @GeneratorReviews
      @GeneratorReviews  Рік тому +1

      Sounds like you got a bad one. Someone like me who sells hundreds of every generator brand I see a lemon every once in a while.
      Sorry you had to go through that. I hope they took care of you.

  • @congsan3528
    @congsan3528 10 днів тому

    Is safe to run sensitive electronic like tv, computer, washer & dryer?

    • @GeneratorReviews
      @GeneratorReviews  9 днів тому

      Inverters generators are a lot better for sensitive electronics