@@benzblogsVlogs regarding sa deepsea boss, safe lang ba mag adjust sa synch parameters? 3v gawin ko 5v, phase angle 5 gawin kong 9. 8610mkii deepsea...
Good morning sir we are having an issue with oye diesel generator, the display says under voltage shutdown and when we start the system it only last like 5 seconds and then it shutsdown again. Thanks for your videos and your time.
Do this first start and check the rpm if stable after that if stable thin check the avr volatge fuses use multi meter to do that if volatge is zero or have 50-vac thin just excite it
@@benzblogsVlogs thank You do much for the quick answer You are saving lifes. I forgot to Say that mantainance team change the batteries with other that migh have a lower amp. That can be a reason too? Thanks again for all this videos !!!!
Sir im in vacation ahm if the problrm underfrenq. Take a look first is the alarm shows with load or without load now if the alarm shows without load just simply adjust the frequency accordingly to the freq.50/60 hz and also check first whin the engine start if there is voltage ok sir
Ok tool kit ay ginagamit lamang para electronics engine meron suang tinatawag sabihin na nating block box or ecm yan jan natinmagagamit pang program ant pang troubleshoot ang toolkit
Sir ask ko lang po Kung anong irerekomenda magandang magandang libro about sa diesel Generator set.troubleshooting , inspection at Kung saan mga naka locate Yung mga sensor ng Genset .
Why sometimes phase voltage are not balanced with respect to ground. We have one DG where phase B was showing 190V Ac only but other phases are around 230v ac.
Meaning this is 3phase do one thing make a reaistance test every coil but in order to know remove first the connection mostly voltage unbalance is coil problem
@@benzblogsVlogs You're possibly or i can say your correct Sir as we measure different readings on our insulation test. Thank you for your support Sir. More power to your channel.
Hi Sir. I’ve juste bought an Atlas Copco used generator QAS200 and I have a failure (underfrequency) and the generator doesn’t start. I thought it was batteries which we changed and nothing happened. Can you help to troubleshoot please ?
chief i have a question ano na ang dahilan bakit ayaw mag tuloy ang starting, nawawala ang supply sa fuel relay, start lang ng 30 seconds hindi na aandar nagcrank lang?
Bro before what is the nominal voltage before not drop first run without load if voltage is in normal if not check the exciter winding if have resistance thin check the diod if in good condation now if all good thin replace avr
Hi Sir good day to you I am tapas from banglades FG wilson 50kva diesel generator Un load generator voltage L-N 235volt, frequency 49.80hz & load L1-10amp,222volt,49.4hz,L2-15amp,218volt,49.3hz,L3-35amp,180volt,48.9Hz then generator shutdown so what problem.... Please sir urgent case
My friend My DA output is showing 20v, tried to excite the exiciter by external battery, it is developing 110v for the time battery is connected. The generator is of 380 Kw. Any suggestions pls.
sir good day po,yung magnetic pick up po bh may tendency din na ma dumihan at numipis kaya hindi gagana..tsaka ilan yung specific volt nya para gumana..salamat po
If you want to make 400volt ac shout be your alternator is 12leads in order to convert the wiring to series Y to prduce the volatge 400but your need to re connect your avr connection and to change to configuration from your module in order to work
Off tge breaker run the generator adjust the voltage in tge avr using the voltage potentiomter there in the avr use multimeter to measure the voltage if its blance its always have variation 1-2 deferences
Hi Sir , our generator Cummins brand 169Kva always shutdowns everytime we run for a minute. It shows under voltage alarm. What could be the possible problem? Kindly help. Thank you
Ok undervoltage means voltage its below from nominal voltage now till me what is the output of the voltage and make sure all the fuse from your sensing line is all in good condation
Ah ok sir if your engine mechanical or conventional normal that the frequency is 62 hz but if electronic should be 60hz but mean while if you talk about unbalance load you have to refer that to your load connection
Sir, my 1000KVA / 400V /50hz cummins genset kami, amg controller nya deepsea 8610 MKII, low voltage sya 10V lang na produced pero reached nya rated speed. Nacheck ko na ung rotating diode goods naman, nag excite ako ayaw mag build up ng voltage, nacheck ko na ung + at - ng exciter may 12ohms naman. Ok naman mga fuse at wire connection, ano kaya problema??
Nong ng excite ka gomamit kaba ng multimter para sukatin ang boltahi or doon kalang ng check sa module? Answer first para maidentify ang prob thank you
@@benzblogsVlogs nag produced sya ng voltage nung binaligtad ko ung postive at negative ng excitor sa avr, tapos binalik ko sa original position. Nag produced na sya ng 400V, kaya nagtaka ako bakit ganun, eh original connection nya un since nabili ng company namin ung gen.set. ngaun po, nag synchronized ako at amg load umabot sa 390A which is balance naman sa ibang gen.set. yung nag increasr ng load, pumutok ung fuse ng AVR. Ano kaya problema?? Pangalawang beses na un na pumutok fuse. Ok naman mga wiring walang grounded, pati excitor ok din. Posible kaya na low insulation na ung alternator windings? Mainit din ung body ng alternator
@@benzblogsVlogs posibly po ba mangyari un na binaligtaf ung exciter saka lang sya nag produce ng 400V, tapos binalik sa dati position ung terminal ng excitor, Ok na sya. Un lang, ung tumaas ung load, pumutok ulit ung fuse ng avr
Boss tanong lng kc genset nmin under voltage din..ok nman Po ung hrz & RPM at reading Ng voltage, kaso pag niload na Po Nmin bgo sia Ng under voltage.salamat Sana masagot nio ang Amin katanongan. Maraming salamat Po.
Ganyan ang nangyari sa genset ko brad Under Low voltage yng lumalabas sa module ay 360v lng kaya namamatay pro check ko ang main wire nyan bro yng 3phase at single phase ok naman ang kuryinti nya 416v ang 3phase at 230v naman ang single phase ano kaya yon brad ang sira module sguro or kailangan i adjust ang setting
Make sure lang sir na sa viltage sensing side is same na voltage nag nababasa mo sa tester doon sa breaker side if parihu thin there wrong with ither program or a wirng problem only
sir gud pm po, yung cummins generator 6cta 8.3 new calibrate po injection pump pero pag my load hirap po xa pati load bank namamatay po ano pong problema ng ganung case..thanks po
Ok there is lots of reason first is the load my be hundred percent load directly or your configuration is went wrong or check the alarm so we can point out what going on!
@@benzblogsVlogs Oo nga pala Sir,motorized xa,nka synco pala,kaso d kuna pinagana isa, dahil maliit nlng load,tsaka may sira dn..cge Sir salamat,nka subscribe nko sau Sir hehehe
Fail to start sir pwedimg hinangin mgbleed ka sa fuel check ko if my fuel return and thin check duel relay is active during cranking make sure suply is distributed correctly
Ok po fuel system aandar po sya infew second at magshutdown sometime ang alarm nya under voltage sometime fail to start sir pero pag tinanggal mo sa fuel solinoid aandar sya thanks po
Now if you connected correctly positive and nigative to exciter and still give low voltage means ither your exciter is defective or the alternator itself have problem
Sir pag over voltage ganito lang gawin mo start mo check ko line to line ang voltage at ano ba ang nominal na nakaprog sa module at check mo din mga fuse
sir gud am, what are problem if my gen set running only an hour after drop into 90 volts and the frequency goes up,almost more than 70hz after drop to 90 volts.thanks, god bless
@@benzblogsVlogs san ko makikita ang charging Alt sir. Currently naka power up ung genset without load para ma check ko kung sa genset ba o sa load ang problem. DSE 6110 MKll panel
Gud pm sir, panu po ba i troubleshoot pag ang indicate po ay "electrical tripp" note 500kva gen set po and gendiesel po ang brand, thank you po sa sagot
Onang tingnan mo is my nakainstall ba young breaker mo na shuntrip if meron nakaprogram yan sa module at may isanag relay yan para sa trip ng breaker mo
Sir good day to you sir make aure rpm in a good condation if it is high voltage and the engine is normal just adjaut in your AVR in order to fix the problem
Pasensiya sir pero hindi ko nakunan ng video pero ganun yung pangyayari. Kung baga eh nag bigay siya ng generator over voltage tapos nag adjust kami sa AVR pero ganun pa din alarm na binibigay niya. Hindi kaya sa AVR ang problema?
Bus not live meaning there is no voltage going to your module buss sensing make sure also the the aux contact is working properly for feedback going bact to the module
Sir ganito yan loading voltage not reach ano ba ang bolatge ouput na nalabas sa generator mo ngayun kc halimbawa 400 ang ac before ang configuration tapos ngayun ang output lang ay 380 lang hindi inabot you g loading na 400
Sir high volatge alrm always i ask to check if engine speed if stabel thin check the avr volatge now if all ok at zelo load this. Only config you need after that put over and under voltage delay your prob solve
@@benzblogsVlogs Thank you sir. We will try your suggestions. But if the AVR are faulty, can we replace it with different type of AVR? like a generator set with shunt excitation alternator and a Stamford AS440 AVR to a Stamford MX321 AVR with pmg type of excitation?
Ganito mona sir paandarin mo teaterin mo sa module yung voltage sensing ng module if my voltage kong wala check ko fuses kong my busted now kong ok at ganon padin check mo fuse ng avr at kong ok at same walang voltage mg excite kna okay
Hello sir i have weserbeke 11.0BDT it was running good after long time not start no output voltage from alternator zero volt when I'm giving excitation 12 vdc voltage coming 25-30 voltage only and then when i remove excitation Voltage coming back same as before to zero please help me how to solve it
You are doing great Master blessings from saudi arabia never give up keep making good technical videos
As you to coz your you the best tutorial ved.
Nice one sir your so amazing more vidio sir thank you 😊
Thank you sir bless you
Will be sure to check out for the culprits that you mentioned whenever the undervoltage alarm comes up
What you mean culprits sir
'culprit' here refers to the potential undervoltage cause
Nice idol thanks for sharing..
Thanks for sharing, great video, keep it up👍
Thank u sir
Thanks bro..... GODBLESS ❣️❣️
Bless u bro
Watching master
Nice video but please be showing us the exact and where you are removing the fuses. Thankyou
No problem there is two vedio about it check the other one
Sir I have checked but couldn't find any videos related to it in your page, thank you@@benzblogsVlogs
Hi.. thanks for your effort to make informative video I wanna ask you to use good cameraman ..
I dont have im alone and only make breaktime coz duty time no allowed
Verry defecult
Thank you dito boss... Meron ako natutunan...
Yea boss marami tanong lang kong my itanong no prob sasagutin natin sa mkakaaya ko salmat
@@benzblogsVlogs regarding sa deepsea boss, safe lang ba mag adjust sa synch parameters? 3v gawin ko 5v, phase angle 5 gawin kong 9. 8610mkii deepsea...
@@johndimaglipac8652 max n Gina gawa ko Lang boss is 5v
@@benzblogsVlogs etry ko boss, sana maka synch na... Maka synch naman pag naka houseload lang...
Good video sir.thanks
Welcome air bless u
Thanks for the video
Bless you too
Thanks Sir keep going
Bless u too
Good morning sir we are having an issue with oye diesel generator, the display says under voltage shutdown and when we start the system it only last like 5 seconds and then it shutsdown again.
Thanks for your videos and your time.
Do this first start and check the rpm if stable after that if stable thin check the avr volatge fuses use multi meter to do that if volatge is zero or have 50-vac thin just excite it
@@benzblogsVlogs thank You do much for the quick answer You are saving lifes.
I forgot to Say that mantainance team change the batteries with other that migh have a lower amp.
That can be a reason too?
Thanks again for all this videos !!!!
Only crank not run
@@benzblogsVlogs yes it only Crank it's not really running
Hi !! If the alarms is gen under frequency, What could be the problem? Thanks for the help, awesome video
Sir im in vacation ahm if the problrm underfrenq. Take a look first is the alarm shows with load or without load now if the alarm shows without load just simply adjust the frequency accordingly to the freq.50/60 hz and also check first whin the engine start if there is voltage ok sir
Congrtzz🥰🥰🥰
Thank you
boss pag ba ginamitan ng tool kit yung ats at synchro panel ba ang pag gagamitan ng tool kit?
Ok tool kit ay ginagamit lamang para electronics engine meron suang tinatawag sabihin na nating block box or ecm yan jan natinmagagamit pang program ant pang troubleshoot ang toolkit
Sir ask ko lang po Kung anong irerekomenda magandang magandang libro about sa diesel Generator set.troubleshooting , inspection at Kung saan mga naka locate Yung mga sensor ng Genset .
Sir lahat naman ng manual every engine anjan yunv sensor anong pary saan makikita
@@benzblogsVlogs salamat sa Tugon sir.
Nindota atong sa Dubai aquarium jie oi hehehe nindot jud diha sa dubai ba heheh
Oo sir medyo expinsive lang sa bahay
Why sometimes phase voltage are not balanced with respect to ground. We have one DG where phase B was showing 190V Ac only but other phases are around 230v ac.
Meaning this is 3phase do one thing make a reaistance test every coil but in order to know remove first the connection mostly voltage unbalance is coil problem
@@benzblogsVlogs You're possibly or i can say your correct Sir as we measure different readings on our insulation test. Thank you for your support Sir. More power to your channel.
Thanks brother...are you a Filipino?
Yes sir
@@benzblogsVlogs thanks kabayan!may fuse b ang avr?anu prblima bigla mag warning voltage down tas shutdown
Hi Sir. I’ve juste bought an Atlas Copco used generator QAS200 and I have a failure (underfrequency) and the generator doesn’t start. I thought it was batteries which we changed and nothing happened.
Can you help to troubleshoot please ?
If not start mean there is other problem
Check the fuel bleed it while crank after fuel bleeding it will start
chief i have a question ano na ang dahilan bakit ayaw mag tuloy ang starting, nawawala ang supply sa fuel relay, start lang ng 30 seconds hindi na aandar nagcrank lang?
Mechanical hindi electronics engine
Pag mechanical pweding sa oil sw
Where are the fuses that you disconnected ?
In the back your module there is sensing and that is connected to your alternator wich is joint with fuse
Some its inside the alternator but mostly is in the panel area if 3phae this is 3fuses
Please sir,we will like to see the where you disconnected the fuses from. A picture or video. Thankyou@@benzblogsVlogs
Sir benz good day.. ako antolin ka trabaho mo b4 sa Powercity corporation. Tanong lang may hiring pa ba kayo jan?
Yes check mo sa link in senior technician nkita ko previews week or hanapin www.jubailibros.com
@@benzblogsVlogs thankz benz try ko mangutana
Sir goodmorning,,ano poh ba ang tahilan ng pagputok ng AVR.?
Pweding mali ang sensing connection pwding or mali connection itself
Thank you, I have fg wilson perkins all of a sudden voltage drop to 62 volt and L-L 113 volt what do you think is it same?
Yes brother
Bro before what is the nominal voltage before not drop first run without load if voltage is in normal if not check the exciter winding if have resistance thin check the diod if in good condation now if all good thin replace avr
thank you brother 👍
@@sultanalsubaie7377 your welcom brother
thank you today I have checked generator and found one cable not attached to AVR, after I connect cable voltage become normal.
Sir benz pwed po bah mka hingi nang tulog sa perkins 180 kva generator po nag ooverheat bago na gasket watr pump at new service ang radiator
Sir nag palit kana ba ng thermostat?
Sir pano ang checking mo pra masure natin kong mag overhit ba ang engine or ang sensor lang ang faulty
Wow nindota ana na makina jie oi hehehe sa mga building na jie gina gamit?
Oo pre marami talaga
@@benzblogsVlogs ayus diay kaayo ana ba 😍
Master tanong ko lng po nag change oil lng po ako ng volvo penta genset TAD13 pag pa andar ko po may ECM alarm na po
Just remove the power supply or the battery to reset juat split seconds
Afyer that crank 3time before start
Ganon padin po master
Check gamit k Ng diagnostic tool para ma identify mo Yung engine problem
Brother my comap intelite AMF 25 shows BOC gen l1l2< v
BOC gen < frequecy
What shall I check
This breaker over current
Check you load and check the the engine if in stable
@@benzblogsVlogs it's checked without load brother
@@samuelgetachew2013 check your comfiguration and adjust the delay time
@@samuelgetachew2013 and check the full load of your genwrator my be exceed that why its alarm BOC
Hi Sir good day to you
I am tapas from banglades
FG wilson 50kva diesel generator
Un load generator voltage L-N 235volt, frequency 49.80hz & load L1-10amp,222volt,49.4hz,L2-15amp,218volt,49.3hz,L3-35amp,180volt,48.9Hz then generator shutdown so what problem....
Please sir urgent case
Yes sir but your line to line sir if zero load what voltage?
And how about your line to nutral at zero load what is the voltage sorry late reply im sleeping the time you message me
Ill give you example if your line to line volatge is let see 240v your nutral should be 139v
If you have vedio sir send me or message me in my facebook or my group so i can help you more
My friend My DA output is showing 20v, tried to excite the exiciter by external battery, it is developing 110v for the time battery is connected. The generator is of 380 Kw. Any suggestions pls.
Sir check mona diode mo kong ayaw mgbuild ng 220
Sir why Generator that has Lost voltage, 400V, 3 Phase Alternator at new rewinding
No voltage out put check wingding correct check avr connection correct if all corrext thin message
Next time sir, please remove the background music, its better.
Thank you
Thank you sir no prob
boss if output voltage is not the same what is the problem.. line 1/2/3 652V/648V/703/V???
Thisbis with or without load
If this happen only with load meaning you have unbalance load that why uts also unbalance your voltage
hi genarator has negative values on the kws how do i fix it
Either ct connection wrong and voltage sensing wrong
sir good day po,yung magnetic pick up po bh may tendency din na ma dumihan at numipis kaya hindi gagana..tsaka ilan yung specific volt nya para gumana..salamat po
Ok sir pwedi madumihan at dina gagana di sya acuraye and reading and starting voltage nyan is ac 0-2 vac
I have a vedio on that also how toninstall mpu
400/220 volts yong generator but only 220 load supply its oke in 400 no output or low voltage,what is the main reasin,i need your help this issue sir
If you want to make 400volt ac shout be your alternator is 12leads in order to convert the wiring to series Y to prduce the volatge 400but your need to re connect your avr connection and to change to configuration from your module in order to work
Lot of thing to change in order to work propperly
thanks sir
Hi sir,can you advise how to increase value of L1,L2 and L3?
L1-L2.....374V
L2-L3.....380V
L3-L1.....366V
How to fix this?
Please help
This happen dur to the load what module you are using
Off tge breaker run the generator adjust the voltage in tge avr using the voltage potentiomter there in the avr use multimeter to measure the voltage if its blance its always have variation 1-2 deferences
Hi Sir , our generator Cummins brand 169Kva always shutdowns everytime we run for a minute. It shows under voltage alarm. What could be the possible problem? Kindly help. Thank you
Ok undervoltage means voltage its below from nominal voltage now till me what is the output of the voltage and make sure all the fuse from your sensing line is all in good condation
Double check all the fuse from sensing line going to the module and from your avr ok
The technician checked it sir today and said that the AVR is defective.
One generator 80v L1L2 I am cheng abr sem voltege ricive wean I give 12v direct excitor fild buildup voltege 510v so waht happened pliz
If its buildup thin replace the avr
Sir what is the problem of generator if it is unbalanced voltage and frequency is 62hz? Because some lights is busted
Sir filipino pwedi po tayo magtagalog
Ah ok sir if your engine mechanical or conventional normal that the frequency is 62 hz but if electronic should be 60hz but mean while if you talk about unbalance load you have to refer that to your load connection
Hello sir 45 kva Daneyo altarnator axciter wind but not auto current show
12 volt charg to current show
Yes sir have a good day there is volatge but no current show ?
Ok new exciter rewind what you mean but still no volatge output is that xorrect?
Sir, my 1000KVA / 400V /50hz cummins genset kami, amg controller nya deepsea 8610 MKII, low voltage sya 10V lang na produced pero reached nya rated speed. Nacheck ko na ung rotating diode goods naman, nag excite ako ayaw mag build up ng voltage, nacheck ko na ung + at - ng exciter may 12ohms naman. Ok naman mga fuse at wire connection, ano kaya problema??
Nong ng excite ka gomamit kaba ng multimter para sukatin ang boltahi or doon kalang ng check sa module? Answer first para maidentify ang prob thank you
@@benzblogsVlogs nag produced sya ng voltage nung binaligtad ko ung postive at negative ng excitor sa avr, tapos binalik ko sa original position. Nag produced na sya ng 400V, kaya nagtaka ako bakit ganun, eh original connection nya un since nabili ng company namin ung gen.set. ngaun po, nag synchronized ako at amg load umabot sa 390A which is balance naman sa ibang gen.set. yung nag increasr ng load, pumutok ung fuse ng AVR. Ano kaya problema?? Pangalawang beses na un na pumutok fuse. Ok naman mga wiring walang grounded, pati excitor ok din. Posible kaya na low insulation na ung alternator windings? Mainit din ung body ng alternator
@@agent70vids3kong ganon medyo may problima na fiose but dipa sya sira
@@agent70vids3 pwedi pa syang magamit ok lamg yan
@@benzblogsVlogs posibly po ba mangyari un na binaligtaf ung exciter saka lang sya nag produce ng 400V, tapos binalik sa dati position ung terminal ng excitor, Ok na sya. Un lang, ung tumaas ung load, pumutok ulit ung fuse ng avr
Boss tanong lng kc genset nmin under voltage din..ok nman Po ung hrz & RPM at reading Ng voltage, kaso pag niload na Po Nmin bgo sia Ng under voltage.salamat Sana masagot nio ang Amin katanongan. Maraming salamat Po.
Ok sir ahm ilang kva sya at anong load meron kayo
facebook.com/groups/1581429425388674/?ref=share message me here this my page im ready to help
175kva, 400v, load 70kw lng Po boss.
Ganiro sir sir tingnan mo yung usok ng engine mo sir maitim ba or maputi ang osok
Medyo puti na Po boss..bka magawan pa Ng paraan,. MSC failure muna bgo sia Ng alarm Ng under voltage. Magalaw ang hrz & rpm..bgo din ang ARv.
Ganyan ang nangyari sa genset ko brad Under Low voltage yng lumalabas sa module ay 360v lng kaya namamatay pro check ko ang main wire nyan bro yng 3phase at single phase ok naman ang kuryinti nya 416v ang 3phase at 230v naman ang single phase ano kaya yon brad ang sira module sguro or kailangan i adjust ang setting
Make sure lang sir na sa viltage sensing side is same na voltage nag nababasa mo sa tester doon sa breaker side if parihu thin there wrong with ither program or a wirng problem only
Baka nga sa program boss icheck ko ulit ang parameters non may mga standard rating kaba bro ng program non wala kasi ako ehhh...
Hello sir, kaila ka ni sisoy, taga bacuag surigao
Yes po taga samin po yan
Taga bacuag man pud ko sir
@@benzblogsVlogs kumpari mi ni sisoy, co-woker me sauna sa klift
Sir.vince paano mag synchro ng genset gamit ang deepsea 8610.?
Hehehe nakakahiya pwedi maka hinge ng diagram kung ok lng.
Sir i try coz you know company
For now i have training for sync using 8610 dse
Ok sir .venz. Salamat
But i can help you if you have some problem about it
Bless u sir sensya na
sir gud pm po, yung cummins generator 6cta 8.3 new calibrate po injection pump pero pag my load hirap po xa pati load bank namamatay po ano pong problema ng ganung case..thanks po
May ved ka kong pano sya namatay para malaman ko din
Mostly pag ganyan electtonics sya tama nakalebrate nyo pa ng maayus sa prog ng injector
Good evening Master,what is the trouble if the generator sto0 when the load is on ,thank you
Sir can you explain it properly if you don’t mind?
Ok there is lots of reason first is the load my be hundred percent load directly or your configuration is went wrong or check the alarm so we can point out what going on!
lido pano kun nag running yun genset at may voltage sya tpos ayaw mag stop ano gagawin ayaw mag emergency stop ano dapat gagawin
If ayaw gumana lahat to make stop dalawa lang yan cover the airintake or remove the fuel supply from intake line
I have one question to you brother how to flash out a deep sea when display showing nothing
If the light if there you can flash
Unliss if your module is not taking power supply not posible
Anong ECU to sir benz? ADEM 4?
Yes sir perkins adem4
Hello..
Good day sir my generator going up when 3phase battery charger load .but if not it's normal
What kva you have
Sir generator ko inaalagaan, minsan magshutdown bigla,ang alarm,generator failed to closed, san kya troubleshoot nyan Sir Bens.?.Perkins xa 500kva.
Motorized breaker bayan sir
Sorry late reply pagenerator fail to closed sir check monlan aux contac nya kong may binabato pabik sa module
@@benzblogsVlogs Oo nga pala Sir,motorized xa,nka synco pala,kaso d kuna pinagana isa, dahil maliit nlng load,tsaka may sira dn..cge Sir salamat,nka subscribe nko sau Sir hehehe
Salamat sir malaking bagay na sakin yan sr bless u and keep sfe
Hello sir unsaon pag re program pag wala ka kabalo sa pin code sir?
Try 1234 or 0000
Sir we have a fail to start and under votage alarm inour 7320 dse controller deutz genset pls help me thank you
Fail to start sir pwedimg hinangin mgbleed ka sa fuel check ko if my fuel return and thin check duel relay is active during cranking make sure suply is distributed correctly
Ok po fuel system aandar po sya infew second at magshutdown sometime ang alarm nya under voltage sometime fail to start sir pero pag tinanggal mo sa fuel solinoid aandar sya thanks po
Okganito yan check mo oil sensor at sw mo ither jan ang my problema
sir ask ko lng pi kung paano iadjust ang 1725rpm&57hz gawin ko sana 60hz & 1800 rpm po jcb generator g250rs sir
Sir ponta ka sa speed controller hanapin mo doon speed adjust pihiyin mo lang hangang omabut sa rpm
Na gusto mo
Kong wala naman need mo ng loptap para e adjust
You need also to ajust the config setpoint of your module accordingly
Sir ung genset FG Wilson tapos kapag idle sya Hindi I on ung breaker 230 v sya Pero kapag I on na ung breaker 150v nalang sya ano Kaya problem
Ahm to make first use multi meter to measure each line before the breaker if the voltage same thin check you rotor diode defective
@@benzblogsVlogs tnx
But if Exciter supply with 12v and still give a low voltage output what is the next thing to do?
Ok make sure you polarity is correct so we can proceed to the next
Now if you connected correctly positive and nigative to exciter and still give low voltage means ither your exciter is defective or the alternator itself have problem
Double check the resistance of the exciter ,winding ,diode and all posible like grounding check in the winding ok
good day sir how about if the genset is overvoltage
Sir pag over voltage ganito lang gawin mo start mo check ko line to line ang voltage at ano ba ang nominal na nakaprog sa module at check mo din mga fuse
sir gud am, what are problem if my gen set running only an hour after drop into 90 volts and the frequency goes up,almost more than 70hz after drop to 90 volts.thanks, god bless
Run it dont put load or off the breaker if same voltage and frequency ok thin message me
60kva Leroy-sommer Genset.
Nag auto shutdown after 4hrs then 2hrs. Nakalagay sa control panel ay DC sign error code. Ano kaya problema? Thanks
Sir check mo yung charging alt mo sir ok normal
@@benzblogsVlogs san ko makikita ang charging Alt sir.
Currently naka power up ung genset without load para ma check ko kung sa genset ba o sa load ang problem.
DSE 6110 MKll panel
Send me picture
And message me in messanger or whatupp
@@benzblogsVlogs FB na lang sir. Ty
Gud pm sir, panu po ba i troubleshoot pag ang indicate po ay "electrical tripp" note 500kva gen set po and gendiesel po ang brand, thank you po sa sagot
Onang tingnan mo is my nakainstall ba young breaker mo na shuntrip if meron nakaprogram yan sa module at may isanag relay yan para sa trip ng breaker mo
Ngayun tingnan mo kong nagtrip ang nreaker ibig sabihin pwedi yan common electrical trip or high current or depwndi sa program ng module mo
Medyo luma na kasi un sir, ndi ko na alam kung nasa ung module nun po, saan po makikita ung shunt
Kung ganun nga sir ang cause, panu ko po sya ulit mapapa takbo ng ma ayaos at maiwasan po ang electrical tripp
Slamat po sir ng marami
How troubleshooting of High voltage in Generator..
Sir good day to you sir make aure rpm in a good condation if it is high voltage and the engine is normal just adjaut in your AVR in order to fix the problem
Sir magandang araw po. Ano po gagawin pag alarm ay Generator Over voltage.
Sir pag overvolage magadjust kalang sa avr mo
Simple sir ponta ka sa avr mo adjust mo doon
Nag-adjust na kami sir pero ganun pa din. Meron pa din Generator Over voltage.
Send mo nga ved para mkita ko anong naguaro
Pasensiya sir pero hindi ko nakunan ng video pero ganun yung pangyayari. Kung baga eh nag bigay siya ng generator over voltage tapos nag adjust kami sa AVR pero ganun pa din alarm na binibigay niya. Hindi kaya sa AVR ang problema?
Bro update video. bus not live
Bus not live meaning there is no voltage going to your module buss sensing make sure also the the aux contact is working properly for feedback going bact to the module
hello sir
what happen alarm loading voltage not reached come out
Sir ganito yan loading voltage not reach ano ba ang bolatge ouput na nalabas sa generator mo ngayun kc halimbawa 400 ang ac before ang configuration tapos ngayun ang output lang ay 380 lang hindi inabot you g loading na 400
Check mo ang confige ng module sir makikita mo doon kong ano ang nakalagay na loading volatge
@@benzblogsVlogs sorry sir i can't understand speak filipino?
Deep sea controller not showing bus voltage
If buss voltage not shown to the module meaning ither fuse busted from v2 and check your v2 wiring
Turn the damn music off.
Sir alarm min voltage geneset
What you maen sir
Anong klasing alrm
Hi
Ho bro
Please help sir we have same problem with our 1mva marathon electric dvr2000e avr, engine cummins...
Yes sir what i can help
What the problem with your generator
@@benzblogsVlogs only 26volts output voltage i already check wiring ang all connections including fuse
3 phase the genset shutdown after alarm
Do one think send me the picture of avr
Herbert jamero (sisoy), i mean bacuag surigao
Sir mosta man diha now lang nko nkita imo comment
How about genset high voltage alarm ?
Sir high volatge alrm always i ask to check if engine speed if stabel thin check the avr volatge now if all ok at zelo load this. Only config you need after that put over and under voltage delay your prob solve
@@benzblogsVlogs Thank you sir. We will try your suggestions. But if the AVR are faulty, can we replace it with different type of AVR? like a generator set with shunt excitation alternator and a Stamford AS440 AVR to a Stamford MX321 AVR with pmg type of excitation?
Yes you can just follw the instruction how to do it
Hi can us Cummins engine controller .Volvo engine
Yes no prob
Juat ask no prob bro bless u
THE MUSIC IN YOUR VIDEO IS NOT SOUNDING GOOD,
Thank for concern i do no prob
boss patulong naman L1, L2, L3 Undervoltage and gen volts low
Ganito mona sir paandarin mo teaterin mo sa module yung voltage sensing ng module if my voltage kong wala check ko fuses kong my busted now kong ok at ganon padin check mo fuse ng avr at kong ok at same walang voltage mg excite kna okay
Hello sir i have weserbeke 11.0BDT it was running good after long time not start no output voltage from alternator zero volt when I'm giving excitation 12 vdc voltage coming 25-30 voltage only and then when i remove excitation Voltage coming back same as before to zero please help me how to solve it
That is what we called loose of magnitism that why whin. U put excitation it return all the magnitism in your winding and its work back to normal
What solution how can I solve it please reply as soon as possible
Do one thing tester your exciter what ohm you get it should be 10-18 0hms thats still good
Of more than that value or no value its faulty already
Sir whole alternator winding value is good condition correct ohms showing but no build up voltage
Switch off the music
All my vlogs now no music at all
Sir pa help naman
Ano yun.sir
Pwede po ba kita ma pm sa messenger sir? Papa help po sana ako about sa generator ko po
Sana po matulungan nyo ako sir
Ayaw po kasi mag stop yung engine. At sa panel po nakaindicate na *warn stop fault
No prob sir message me i reply you there