Generator and Technical Contents
#2806engine synchro options troubleshooting
In this video we are given some ideas on how to fix this type of problem and we show you how we succeed in synchronising.
Переглядів: 170
Відео
#2206seriesengine #talalternator #synchronizing
Переглядів 323День тому
In this video i show you the troubleshooting of what this generator is and how to use a multimeter to check pls watch the video till end thank you
MECCALTE ALTERNATOR DIFFERENT STANDARD CONNECTION? 400VAC 50HZ
Переглядів 11814 днів тому
In this video i explain what happened to the connection why it is reverse polarity and it looks like wiring is not the usual wiring we see in other alternator which is 400vac 50hz output pls watch till end.
#4006SERIES #ENGINE #MYDAILYWORK
Переглядів 14414 днів тому
Load testing 4006 series engine, preparations, load calculation, and programing pls watch my video thank you always.
Deepsea 8610mk2 Basic configuration explain
Переглядів 20214 днів тому
In the video i explain on how to do a configuration what are the function how to make it work make aure to watch ao you can underatand and comment below if u have questions thank you
#Troubleshooting #5008SeriesEngine
Переглядів 20421 день тому
In this video where i show you the new and fresh engine that i do the modification, configuration based on what is in the video and watch till the end thank you so much.
DEEPSEA 8610 MK2 wiring diagram and functionality simplify
Переглядів 340Місяць тому
In this video explain how to do the wiring connection and its function including the dsenet and msc connection
SOLAR INVERTER AND GENERATOR SYNCHRONIZING EXPLAIN
Переглядів 169Місяць тому
SOLAR INVERTER AND GENERATOR SYNCHRONIZING EXPLAIN
HOW TO TROUBLESHOOT AND REMOVE 1206 PRIME PUMP
Переглядів 3322 місяці тому
HOW TO TROUBLESHOOT AND REMOVE 1206 PRIME PUMP
#FACTORYLOADTESTING #770kva and inductive load bank
Переглядів 802 місяці тому
#FACTORYLOADTESTING #770kva and inductive load bank
GOODWE Green operating indicators explain
Переглядів 512 місяці тому
GOODWE Green operating indicators explain
HOW TO PREPARE AND DO MAINS GRID SYNCHRONIZING
Переглядів 8502 місяці тому
HOW TO PREPARE AND DO MAINS GRID SYNCHRONIZING
HOW TO IDENTIFY PERKINS SERIAL NUMBER
Переглядів 862 місяці тому
HOW TO IDENTIFY PERKINS SERIAL NUMBER
HOW TO FIX FAIL TO OPEN BREAKER AND PREPARE SYNCHRO 500KVA
Переглядів 3433 місяці тому
HOW TO FIX FAIL TO OPEN BREAKER AND PREPARE SYNCHRO 500KVA
PERKINS 4012 SERIES ECM CONFIGURATION AVR CONFIGURATION LOAD TESTING PART-2
Переглядів 1653 місяці тому
PERKINS 4012 SERIES ECM CONFIGURATION AVR CONFIGURATION LOAD TESTING PART-2
PERKINS 4012 SERIES ENGINE LOOM INSTALLATION AVR CONFIGURATION DSE CONGRATULATIONS LOAD TESTING
Переглядів 1393 місяці тому
PERKINS 4012 SERIES ENGINE LOOM INSTALLATION AVR CONFIGURATION DSE CONGRATULATIONS LOAD TESTING
INSTALLATION OF L-SERIES IN 1104C PERKINS ENGINE
Переглядів 3963 місяці тому
INSTALLATION OF L-SERIES IN 1104C PERKINS ENGINE
HOW TO ADJUST SPEED TO 1800 RPM AND 240VAC USING R120 AVR
Переглядів 4614 місяці тому
HOW TO ADJUST SPEED TO 1800 RPM AND 240VAC USING R120 AVR
CONFIGURATION 7SETS OF DSE890 WITH 6120 DSE MODULE
Переглядів 1934 місяці тому
CONFIGURATION 7SETS OF DSE890 WITH 6120 DSE MODULE
45KVA WITH AUTOMATIC TRANSFER SWITCH LETS SIMPLIFY
Переглядів 2894 місяці тому
45KVA WITH AUTOMATIC TRANSFER SWITCH LETS SIMPLIFY
110% LOAD TEST USING CONTAINERIZED INDUCTION LOAD BANK
Переглядів 3454 місяці тому
110% LOAD TEST USING CONTAINERIZED INDUCTION LOAD BANK
breaker troubleshooting 300kva synchronizing and ECU fail
Переглядів 1,4 тис.6 місяців тому
breaker troubleshooting 300kva synchronizing and ECU fail
GENERATOR LOAD TESTING 1250KVA WITH 350 DIGITAL AVR AND HEINZ MANN GOVERNOR AND TROUBLESHOOTING
Переглядів 5486 місяців тому
GENERATOR LOAD TESTING 1250KVA WITH 350 DIGITAL AVR AND HEINZ MANN GOVERNOR AND TROUBLESHOOTING
HOW TO TEST GENERATOR EARTH LEAKAGE SHUTDOWN
Переглядів 7226 місяців тому
HOW TO TEST GENERATOR EARTH LEAKAGE SHUTDOWN
SYNCHRO TESTING 300kva and 500kva with the customer
Переглядів 2066 місяців тому
SYNCHRO TESTING 300kva and 500kva with the customer
LSA ALTERNATOR 1500KVA WITH PERKIN'S ENGINE LOAD TEASING AT 100%
Переглядів 3816 місяців тому
LSA ALTERNATOR 1500KVA WITH PERKIN'S ENGINE LOAD TEASING AT 100%
When I connect my pc with device using usb cable, It is not showing anything. It says Com4 inaccessible. I tried manytimes but cant connect to device with usb cable.Any solution?
Watching friend, good evening, nice sharing
Thanka
Sir how are you, I want to ask you one question about generator, I connect the cable from generator to low voltage switch board for auto pourpose but after that the generator is not starting and it's saying ECU data fail and ECU override sir please could you tell me the reason why my generator is saying like that
Acu data meaning this is the communication between your ecu and from your module this problem my happen if not connected correctly or not program the module correctly
@benzblogsVlogs sir thank you for your kind response but the generator was working for 1 year before we connect the cable for Auto main failure mode but after cable connection our generator fails to start and even the filter also have air(there is air in fuel system) and I was thinking is there any possibility that the cable which we connect to the generator for AMF mode cause the problem
I have a Honda EV6010 generator Max Output 6.0KVA, Rated Voltage 120V, 50A, 60Hz, Single Phase. My controller is dead and I have been through two replacement controllers one used and one (supposed) new?. No new controllers are available. So I bought off Amazon HQM611OU 0.5-70V. Will this Smartgen work with my existing Automatic Voltage Regulator? Will it send the DC voltage that my AVR needs to keep up with AC load?
Avr only matain you voltage not to fluctuate or dropdown but its always depend to the engine if engine also not stable also voltage not stable
Good job lodi
Same with you lods
Ang laki nyan lodi
Atos lodi dami nyan
Nice one lodi❤❤❤
Thank u lods
Loss of Mag- PU what does it mean?
Meaning there is connection between you magnitic pickup or defective
Watching kabayan, good evening
Iba ka talaga lodi Ikaw na❤❤❤❤❤
Thank you lods
Hi, my dse7320 mkii keeps restarting, I turn it on and after 30-60 seconds it restarts. I'm afraid to update it because there's a possibility it will restart during the process. What do you advise me to do? Thanks
If restarting update firmware is the solution it will not restart during that process
@@benzblogsVlogs Thank you i will try.
@@benzblogsVlogs My dse7320 mkii it's back to live. You are the best. 💪
Great subject, But you need to show the part when you're talking about it. Also where is the program you're talking about???
Thank u
Did you watch the video its mention there
Please i have an issue on my Perkins 4000 series Heinzmann Actuator, when on the ignition instead of Actuator to move anti clockwise as oppen it will move to clockwise as in off, the spindle will be very strong in off position. But when off it from battery supply it will be free, and move both directions. So could be the problem?
So meaning to this 1.250-1800 kva?
But actuator of this engine is not rotate just push two arms?
@@benzblogsVlogs the actuator is rotating when push by hand, but when battery is connected it will not move to the normal direction, it will move to off and be strong you can not rotate it by hand.
Watching w/ ads kabayan, nice sharing, sending support
Welcome
Hi, tnks for u video, i have a question ple answer me🙏, in my 4012 one of the governors dose not work, mechanic say ecm has problem, what can i do?
If you have diagnotice tools there you can reset or check what really going on to that ecu if you dont have thin just check visually the soleniod if any supply
Can you please explain why 3 pole breakers are use for synchronization applications insted of 4 Pole. In my country they use 4 pole breakers. (When a generator in off status, it fully isolated from the live bus including N)
If your using 3phase 4wire it is posible you use 3pole with busbar nutral or 4 pole breaker no problem with that
If not get resistance is faulty ??
Meaning there is someyhing wrong with the wiring or its not working
Ikaw na talaga lodi..❤❤❤❤
Thanks lods keep it up God bless you
Hello my boss thank you for the video we appreciate...can you please one do a video of how to test a generator using a megger tester?
No poblem
Yea why not
@@benzblogsVlogs thank you for your reply...will appreciate
Hello boss i have this EPG electricaliy powered governor and it not controlling the engine
Check the wiring from speed controller to the control module if correct and check the module if any voltage output 5vdc
Good job lods
Thanks
Cool!!!
Thabks
That's a great information
Welcome sir
❤❤❤
Thanks
Nice lods morning
Thank you too
What are s2,3 and ScE in motorized wiring and where to connect the aux in dse module and its programming
Check all the video therr you can see where it is connection this wiring and if aux contack that is inside of you breaker
Ok yan lods ah
Great job thank you brother.... Correct password... Big thanks from Algeria....
Wc
Hi Chief engineer, I have a 20kVA generator controlled by a Smart Gen controller and I'm not familiar with this controller, and I want to convert the 3-phase output to a single phase. Can the controller be reconfigured to handle the winding setup using the front panel buttons? I don't have the software program. If possible, please guide me through the process.
You need to do alternator rewiring .odule rewiring avr reairing and module configuration
Daming generator sir Benjie,maymikaniko Rin Po ba kayo Jan?
Sa production oo meron din kadalasan ang marami doon sa workshop sa mga branches
Mine is a deepsea 702k and it's starting the gen set in auto mode when power is on and it does nMine is a deepsea 702k and it's starting the gen set in auto mode when power is on and it does not go off. What might be the problem? 7:43 ot go off. What might be the problem?
Ok check your configuration if your amf is active correct connection for your remote or your remote config is active
Mine is a deepsea 702k and it's starting the gen set in auto mode when power is on and it does not go off. What might be the problem?
Check fuel relay is active check configuration check wiring connectors
I used to monitor my generator fuel on dse controller that is. Engine>>fuel level and get like 70% or 20% but yesterday when checking level the dse was showing xxx what could be the problem please update
What is the sensor you use for fuel level sensor if xxx meaning there no supply for your sensor or sensor itself defective or wiring problem
Hello sir I enjoy you videos here in Kenya but I have a question . If the fuel level was showing on the date scree. But it failed to shoe like in the last 3 days what could be the problem
Do kne thing in there controller you should config and save the last 3days before its delete its own
Hello boss...away from this please...i have an easy gen 1500 woodward ...every time i try crank it displays "crank protect"on the screen nd it will not even crank even once...how can we solve this please?
Is this electronic engine?
If electronic engine you need to connect from ecu to know the datail of the alrms but if conventional meaning the problemmis only from the sensor
If crank protect mean that its inable the alarm directly do one thing try to check your oil sw not sensor if there is and try to disble for while thin check the the wiring if any shorts or try to crank using bypass if ceanking
@@benzblogsVlogs thank you sir for your advice..i always treasure the fact that you always respond to our messages.
@@benzblogsVlogs it is a convectional engine...so i have to have its software from my laptop to disable the switch.
mr. i need sofware deeo sea 6810 email mr
Software if free from the web just make an account from the deepsea so you can get the software
mr. deep sea 8610 calling aplication solution mr
Calling for more in stabdard is 80 and calling for less is 70 but you can change it if this is not your preference
Hello dear sir. I need help .. how can start generator. Everything okay. But im change new penal.Auto start controller 7210.. please i need help
What module before you use
Do you have diagram on wiring you do so i can asaist you in your project
If you chenge the module meaning you need to config
In order to work the temote start
Yes I have everything okay..old penal is working & generator start know...I'm fitting new penal 7210 model... same penal but not start...I don't know how can unlock & how can program...I need help for unlock & program...when i put the old panel it starts perfectly fine the old panel so i am changing it the screen is not working the screen is broken but it works fine so when i put the new panel it doesn't work..I hope you understand 🙏🏽
Good tutorial lods Ang galing mo talaga pag dating Jan salute sayo lods Ikaw na talaga
Same lang tayo lods di lahat ng alam meron ako sometime we need to ask also 💓😊
@benzblogsVlogs Tama Yan lods piro lapit na pasko hehehehe
mr. unit model code8610mk11 model varian0. harderware varian 5 firware file is modelcode8610 mk11model variant 0hardware varian 0 version cek please mr solusion
If not there thin i think check your deepsea software if updated
mr deep sea 6810 mk 11 sofware
Firmware not software
mr. deep sea 8610 change firewere parameter nowhere problem mr
just watching how to set up fuel volume sender. is there a pressure sensor that can doe this , my tank is 1.2m high but just 300 ceiling clearance in acoustic container. Or a distance sensor suitable for deep sea?
In the deepsea there you can select temperature, presure , and level
mr. flasing deep sea 7320
Yea you can
You do update the firmware follow instruction while doing the update
mr. nohp
Good day po Sir, may I ask what is the cause of the powerwizard controller with a model: EMCP 4.1 of our genset has no display?
Make sure all connextion is correct and the fuses
And also double check the configuration
Hello , Where do I download the software from? It's not on the site ! can you send it to me ?
Internet go to woodward there u can for free
@@benzblogsVlogs Unfortunately, the file is no longer on the site. Can you send me a link
Say Generator one more time please!
My Godbless you
Lods gandang gabi
❤thank you