  • @mariancristofovici7506
    @mariancristofovici7506 10 місяців тому +4

    Thank you very much for the valuable information that you provided to us.

    • @sedky69
      @sedky69  10 місяців тому

      Thank you.

  • @BryanAhJack
    @BryanAhJack Місяць тому +1

    Hi. I have a SP6000+ Paradox panel. I would like to program the panel to a schedule arming and disarming using babyware

    • @sedky69
      @sedky69  Місяць тому +1

      @@BryanAhJack The section for auto arming is in the area section. I am not sure if they still allow auto disarming. I would have to check

    • @BryanAhJack
      @BryanAhJack Місяць тому

      @sedky69 ok, yes thank you, i see the auto arming but yes I do not see any auto disarming

  • @costelflueraru2442
    @costelflueraru2442 Рік тому

    Hi I am looking forward to the the training video about the zone setting.
    1. I am not sure how to set the access code (to arm/disarm) for a simple house security setting using Babyware. I know how to do it using the keypad. In Babyware there is a large number of users... while in a house setting I was using one code for arm/disarm.
    2. I am dealings with a situation in which Babyware reports no trouble while the keypad shows trouble (no wireless bell!?). I do have few wireless windows contacts in the system (SP with an RTX3) but I never used or set a wireless bell. Not sure where is coming from..
    Many thanks,

    • @sedky69
      @sedky69  Рік тому

      What is the trouble code?

    • @costelflueraru2442
      @costelflueraru2442 Рік тому

      The key pad flags a trouble. When checking it show missing module: wireless siren. I have never install or use a wireless bell. Not sure how it was added to my system. most likely is a default setting. However when open up Babyware there is no trouble list. Any suggestion is highly appreciated. thanks

    • @sedky69
      @sedky69  Рік тому

      @costelflueraru2442 Have you tried a module scan? Section 955 for the SP and MG series. Tell me which panel you are using and which lights come up when you press TBL. Also once this light comes up, press it and tell me what lights (digits) come up next.

    • @costelflueraru2442
      @costelflueraru2442 Рік тому

      The system is SP7000+, K32LCD, K10V/H and RTX3 with 5 wireless contacts. On the keypad (K32LCD) is shows Trouble Press TBL. I press TBL then keypad shows: Missing Module{arrow up} [0] to View {arrow down}. Press 0 then keypad shows Missing module{arrow up}, Wireless Siren {arrow down}.
      Pressing arrow up again it cycles: Missing module{arrow up}, Wireless Siren{arrow down} when press again changes to Missing Module {arrow up}, No trouble {arrow down} continuing to press the arrow will cycle between this two messages. No other knob/digit is lighting up!
      It is annoying! Babyware shows no trouble!

    • @sedky69
      @sedky69  Рік тому

      ​@@costelflueraru2442 I have a couple of suggestions, but I have never dealt with this panel or a wireless siren before. Check sections 587 options 3 to 6. Set them to off. Also sections 683 to 686, make sure there are no serial numbers there for the wireless siren. sections 691 to 694 same. Section 695 press enter. Once confirmed there is actually nothing programmed for a wireless siren do a module scan section 955. It will clear any trouble related to a non existing module. You can try section 955 before you do all this actually. Let me know what happens. If not there is always the possibility that the panel is defective.

  • @andrasabraham9399
    @andrasabraham9399 17 днів тому +1

    Can you upload a video of a 4 wire smoke detector programming in Babyware?

    • @sedky69
      @sedky69  16 днів тому

      It will take me some time to have this ready, but it is really straight forward. You set your zone to Instant Fire if you want the signal to go immediately or you set it to delayed fire if you want to give the user sometime to silence the alarm. Usually about 30 seconds.

    • @andrasabraham9399
      @andrasabraham9399 14 днів тому

      @@sedky69 I programmed the zone as an instant fire zone. I set the fire reset to the Pgm1 output. I put the 1kOhm resistor at the end of the line. My only problem is that now this fire zone is constantly open. I can only alarm with forced arming.

    • @sedky69
      @sedky69  14 днів тому

      ​@@andrasabraham9399 What kind of smoke detector is this? If it is a low voltage smoke detector, it should go on one of the zones. You don't need to use a pgm. If it is a high voltage you use a relay.

    • @andrasabraham9399
      @andrasabraham9399 14 днів тому

      Cooper M12

    • @sedky69
      @sedky69  14 днів тому

      @@andrasabraham9399 It looks like a low voltage. You can wire the NO and COM to a zone and set that zone to be a fire zone. Use instant for testing, but when you're confident it works, set it to a delayed fire zone to give them some time to silence it in case of a false alarm.

  • @pacovccici
    @pacovccici 5 місяців тому +1

    Thank you for this great video. I recently got sp7000, but when I wired and added the k10v it says the module is offline.

    • @sedky69
      @sedky69  5 місяців тому

      @@pacovccici double check the wiring is good and May be try the keypad at the panel to eliminate any wire damage. Finally you can try doing a module scan. Section 955

  • @DanielsGameVault
    @DanielsGameVault Рік тому

    Can you still access the IP150 from a web browser after firmware version 4.0 ? I just bought an IP150+ (PLUS) and the web interface refuses to load. "IP Exploring Tools" detects the module but I can't change any settings, not even the IP address from DHCP to static - it asks for the password, it SEEMS to work, but in reality nothing gets applied. The HTTP port is zero by default, so the browser refuses to connect to it...

    • @sedky69
      @sedky69  Рік тому +1

      4.0 is a buggy firmware. Try to upgrade to 4.2 or above. Actually once you try to upgrade it will automatically take you to 5.2. You should be able to access the web interface after.

  • @KhalidSulaiman-fx5bk
    @KhalidSulaiman-fx5bk 7 місяців тому +1

    Great Video. Can you please help me to trigger the alarm if a zone/door is opened for more than 5 seconds? I created a Zone to act as a Panic and connected a 3rd party receiver and remote to activate it. I only want to trigger the Alarm if I hold the button down for 5 seconds.

    • @sedky69
      @sedky69  7 місяців тому

      Let me get back to you on this

  • @good2know513
    @good2know513 Рік тому +1

    Thanks for video, could you please tell me if I have 2 K636 keyboards, how should I define them?

    • @sedky69
      @sedky69  Рік тому +1

      I am not familiar with that one, but based on the manual it is compatible with SP and MG series, so I assume it is the same as the K10H. Just a different look. I mean there is nothing to program for a keypad. If it doesn't work it may be a very old model for the Esprit line up.

  • @costelflueraru2442
    @costelflueraru2442 Рік тому

    Hi there, Very nice and informative. Thank you! You said you will do a training on the zone definition. Did you? What is zone speed? and how to use it? I have many more questions. Thanks

    • @sedky69
      @sedky69  Рік тому

      I haven't done any new trainings yet. I hope to do in the new year.

    • @higchannel
      @higchannel 9 місяців тому +1

      Regarding Input speed, you can adjust it to increase or decrease the signal response time in that zone. eg: default 60 input speed allows the sensor to respond immediately however you can adjust it to increase response time to 2.3 or 4 seconds

  • @ibbbraa
    @ibbbraa 2 місяці тому

    I'm getting initiating panel connection Time out and authentication failed wrong panel ID error. What am i doing wrong?

    • @sedky69
      @sedky69  2 місяці тому

      I need more information about your connection. Did you install the drivers for the USB adapter? It sounds like you didn’t choose the correct type of connection. Check my babyware tutorial

  • @Frank-yz6ih
    @Frank-yz6ih 8 місяців тому +1

    Thank you very much ,with your Help IT was possible do do it

  • @RapiscanSecuritySystemsLtd
    @RapiscanSecuritySystemsLtd Рік тому +1

    hi there. i really liked ur tutorial. can u plz tell me the zone doubling concept. how to configure in baby ware

    • @sedky69
      @sedky69  Рік тому

      Thanks for your comment. I have never used that ATZ setup so I am not able to advice on it at the present time.

    • @nguyenbrian754
      @nguyenbrian754 9 місяців тому

      U only need tick ATZ function in zone configure section and installation like this Installation manual. eg: u use SP4000, ai zone 1 on panel is zone 1-5 on babyware and 2-6,3-7,4-8. zone 1234 use register 1K, ZONE 5678 use register 2k2

  • @gabortoth3374
    @gabortoth3374 9 місяців тому

    Hello. How do you setup that the keyboard panel shortly beeps 3 times whenever you open the front door? My one does this but I cannot find it in Babyware. Thank you.

    • @sedky69
      @sedky69  9 місяців тому

      Check my video muting/unmuting a zone

    • @gabortoth3374
      @gabortoth3374 9 місяців тому

      Thank you. Your videos are really helpfull!

  • @gabortoth3374
    @gabortoth3374 9 місяців тому

    can you protect the panel with a door sensor in the box without assigning a zone to it?

    • @sedky69
      @sedky69  9 місяців тому +1

      I don’t know. I would use a zone if it is needed.

  • @lombardjohann4733
    @lombardjohann4733 4 місяці тому

    Unfortunately the conection to babyware through ip180 module doesn’t working, no matter what i do i tried all passwords like paradox for IP module, and 0000 for panel ,I have access to ip module over internal network, seems they changed something it works only external over cloud

    • @sedky69
      @sedky69  4 місяці тому

      What is your panel?

  • @gabortoth3374
    @gabortoth3374 9 місяців тому

    hello. Thanks for the video. What is the exact sequence to retrive the panel ID and PC passoword using MG32I?

    • @sedky69
      @sedky69  9 місяців тому

      Hi. I am not sure what the MG32I is. I don't see it on the paradox site, but generally panel id and password are sections 910 and 911 respectively. From the start, press Enter, press installer code, press 910, the numbers are going to light up according to the panel id. You press the same number as they light up to move to the next number. Once you reach the end of section 910, it automatically goes to section 911. Follow the same process.

    • @gabortoth3374
      @gabortoth3374 9 місяців тому

      @@sedky69 My mistake, i have K32IRF keypad. And after entering 910 one of the zone incitacor is shown olny (10). Should I prees 1 and 0 to move to the next part of the panel ID? (I am asking because it is weird that I did not get single digit prompt. The panel is SP6000. Thanks for the further hints

    • @sedky69
      @sedky69  9 місяців тому

      @@gabortoth3374 Watch my next video and let me know if it helps. It should be ready in 30 mins or so.

  • @costelflueraru2442
    @costelflueraru2442 Рік тому

    Sorry in my previous message I was referring to input speed not zone speed. so what is input speed and how to use it? thanks

    • @sedky69
      @sedky69  Рік тому

      I never experimented with that, but here is what I see from the manual: "The Input Speed defines how quickly the control panel responds to an open zone detected on any hardwired input terminal (does not apply to addressable motion detectors and door contacts)."
      I could see this being used with zones that are falsing too often, but I haven't tried it yet, so try it out in a controlled environment before you use it in the field.

  • @chuj9288
    @chuj9288 6 місяців тому

    when i am trying to connect to babyware with the mg6250 it requires panel id/ pc password
    where can i found the panel id of mg6250

    • @sedky69
      @sedky69  6 місяців тому

      Have you tried to login to the panel from the keypad and finding that out? This one seems different. I am not familiar with it, but the default username and password is admin for both

    • @chuj9288
      @chuj9288 6 місяців тому

      @@sedky69 I have tried everything, even to section programming with 3011 and 3012 also with 910 and 911.
      I cannot find the panel id and pc password and when I try to connect with babyware it will not connect

    • @sedky69
      @sedky69  6 місяців тому

      @@chuj9288 From what I see this is a different type of panel. It seems you have to scroll through the menu. Check page 28 of the manual steps 7 and 8. If not you will have to contact your dealer. I am not affiliated with Paradox.

  • @SamirTawfikTec
    @SamirTawfikTec Рік тому

    بشمهندس هل ممكن اركب اكثر من اتنين حساس حركة سلكى NV5 على زونة واحدة MG5050

    • @sedky69
      @sedky69  Рік тому +1

      أنا مجربتش فمش عايز أفتي. عادة بالنسبة لحساس الحركة بنحط واحد بس في كل زون. لو محتاج أكتر من واحد بتوصلهم علي التوازي

    • @SamirTawfikTec
      @SamirTawfikTec Рік тому +1

      @@sedky69 انا موصل 2 و شغال تمام بس انا كنت عايز احط 4 حساسات فى الزيونة الواحدة الف شكر على الرد

  • @Sylvie-GérardGleize
    @Sylvie-GérardGleize Місяць тому

    Great video. Thanks!

  • @Frank-yz6ih
    @Frank-yz6ih 9 місяців тому

    Hello can you please Help me. On the evo192. The newest Software ist Always askimg me to Change the Default Panel ID and Password But dont Accept any number or Letters , before i changed the Login. What ist my mistake?

    • @sedky69
      @sedky69  9 місяців тому

      You can download an older version of babyware. Older versions don't force you to change the password, but the password should not be left at the default. You can also try to change the id and password using the keypad. For evo it is sections 3011 and 3012.

    • @sedky69
      @sedky69  9 місяців тому

      For troubleshooting, disconnect from babyware and see if you are able to login to programming from the keypad

  • @SamirTawfikTec
    @SamirTawfikTec Рік тому +1