R32 Flammability Test

Поділитися
Вставка
  • Опубліковано 25 сер 2024

КОМЕНТАРІ • 47

  • @hum2020
    @hum2020 Рік тому +15

    Interesting but the problem is a leak where you end up with a nearly stationary gas mixture in the air, when the mixture reaches a certain ignited it can explode. Dont be fooled it can be very dangerous.

    • @averyalexander2303
      @averyalexander2303 2 місяці тому +5

      I've wondered about what the risk could potentially be in that situation because we must consider a worst case scenario too. I'm imagining something along the lines of an evaporator failing and suddenly leaking all the refrigerant out into a room and then a furnace coming on, someone turning on a gas dryer or lighting a candle, etc with the gas within its flammable range. No one seems to want to show that though, they just want to show that flowing gas is hard to ignite. That's good to know, but not the entire story.

    • @ExcelTimeSavers
      @ExcelTimeSavers 23 дні тому +2

      In Pakistan blast accidents in ACs increasing

    • @AR-rf9hc
      @AR-rf9hc 12 днів тому +1

      I am from pakistan and here this year new models of air conditioners with r32 have many severe explosions and killed few dozen of people. Slow lekage of gas in room + a spark is all what is required to cause a big explosion. We are now in a state of shock after watching many exlosions hapenning in diffrebt cities

  • @4457004
    @4457004 7 днів тому +1

    A large number of technician and families are dead due to AC blast r32 is charged In those ACS in Pakistan,,

  • @SteveXNYC
    @SteveXNYC 2 дні тому +1

    Why would you make refrigerate flammable, shows the stupidity of engineers.

  • @fouziayameen7023
    @fouziayameen7023 19 днів тому +2

    What about the 3 explodes in Pakistan city faisalabad within one month in Ac invertors filled with R32 gas??

    • @abymani1
      @abymani1 18 днів тому +1

      Cheap gas filled by installers is the main cause

    • @fouziayameen7023
      @fouziayameen7023 17 днів тому

      @@abymani1 can you plz elaborate your answer

    • @vitalheart9841
      @vitalheart9841 13 днів тому

      I think in Pakistan Gas suppliers are mixing some propane gas to reduce cost of R32. If high quality R32 gas is used such kind of explosion is unlikely to happen. Well again, this is only my guess.

    • @JacobsNews
      @JacobsNews 12 днів тому

      @@vitalheart9841 no they are not .. lol ..

    • @raufrauf9862
      @raufrauf9862 38 хвилин тому

      Fake

  • @AmericanFarmerHVAC2024
    @AmericanFarmerHVAC2024 Рік тому +4

    Ignition source? What do you think will happen when the compressor shorts to ground? These things are going to be responsible for so many deaths...

    • @NickSilcox3
      @NickSilcox3 3 місяці тому +3

      Every vehicle I know has their fuel pump submerged inside the fuel tank. Sending electrical power in a gas tank. Yet it’s perfectly safe. Because the lack of oxygen. If there is no oxygen, no fire. Same if a compressor shorts to ground. Everything is contained inside the system. Ignition sources inside the system, but no oxygen, there cannot be any combustion. So it will be like any other burnout.

    • @averyalexander2303
      @averyalexander2303 2 місяці тому

      Nothing would normally happen because there's not supposed to be any oxygen inside the system. But if there's enough oxygen, an explosion is possible. There have been cases of AC units exploding especially during pump down, but the incidents aren't specific to systems using R32. R22, R134a, R410a, etc also become flammable/explosive when mixed with air under pressure.

  • @arom8438
    @arom8438 Місяць тому

    Don’t give me a waiver than . 😂

  • @user-fw2gd2hp1g
    @user-fw2gd2hp1g Рік тому +1

    Nicely done video!

  • @l.crossjr
    @l.crossjr Рік тому +4

    How much did you get paid to be bias on R32 😂😂.
    The real test is to put a restriction on the high side of a system till head pressure goes way up. And if the HP safety fails, Will probably blow up the house

    • @hum2020
      @hum2020 Рік тому +1

      If hp switch fails pressure bypass valve in compressor opens.

    • @l.crossjr
      @l.crossjr Рік тому +2

      @@hum2020 hopefully

    • @hum2020
      @hum2020 11 місяців тому

      if the bypass valve does not open the compressor will stop. no problem,@@l.crossjr

    • @averyalexander2303
      @averyalexander2303 2 місяці тому

      How could the refrigerant explode inside the system with no oxygen?

    • @hum2020
      @hum2020 2 місяці тому +1

      If the high pressure cut out fails the compressor will stop. The danger is a slow leak that lets air ie oxygen into the system then you have an explosive mixture. A Permanant low side vacuum shut down is needed. I don't know if there is one but it is needed.

  • @Noheatcooltech
    @Noheatcooltech 5 місяців тому

    Did anyone see him even try to pull a spark from his lighter?

  • @waylonlevins
    @waylonlevins 11 місяців тому +4

    Who has the patent on R32? You guessed it. Daikin.

    • @Beastphilosophy
      @Beastphilosophy 11 місяців тому +4

      R32's been off patent for ages. R410a is like 50% r32 and the competing next generation refrigerants mostly contain r32 as well.

    • @theeraphatsunthornwit6266
      @theeraphatsunthornwit6266 Місяць тому

      Hmm fishy😂

  • @jamesstauffer115
    @jamesstauffer115 Рік тому +4

    If it's nearly impossible explain all the UA-cam videos showing R-32 systems exploding.

    • @kiyoponnn
      @kiyoponnn 11 місяців тому

      relax stupid murican. even non r32 ac's can and have exploded. r32's main benefit is that it has a lower global warming potential than r410a and uses 7% less electricity than ac's that use r410a.

    • @acomman77
      @acomman77 2 місяці тому +2

      Any refrigerant can explode if enough heat and pressure is applied to it.

    • @averyalexander2303
      @averyalexander2303 2 місяці тому +2

      @@acomman77 Exactly. Look up an MSDS for R134a, R22, R410a, etc and you'll see a warning that it can become flammable/explosive when mixed with air under pressure. The ONLY way ANY refrigerant can combust inside a sealed system is if there's a lot of air inside.

  • @edwardstark8377
    @edwardstark8377 Рік тому +1

    Gosh how i love Daikin over others.

  • @normchristopherson5799
    @normchristopherson5799 5 місяців тому +1

    There is a great deal of misinformation in the comments section. A2L refrigerants such as R-32 are not very flammable nor are they subject to explosion.

    • @jakbo_
      @jakbo_ 10 днів тому

      Are you gonna put that in writing on your invoice for the homeowner? 😂

    • @normchristopherson5799
      @normchristopherson5799 10 днів тому

      @@jakbo_ No problem stating the safety of the A2l refrigerants. The customer's propane grill is more than 10 times more dangerous than R-32 or R-454B which cannot be ignited if connected to their own grill even if you tried to get it started with a propane torch.

  • @JamesPettinato
    @JamesPettinato 3 місяці тому +1

    I hate these flamabiIty tests, these geniuses forget one big thing, the flamible gas travels tjrough the system with flamabile "OIL" mix r33 and poe you get napalm . Redo yhis test with r32 mixed with poe oil

    • @CptCrunch816
      @CptCrunch816 3 місяці тому

      Interesting

    • @normchristopherson5799
      @normchristopherson5799 3 місяці тому

      That is simply not true. Lots of misinformation in these comments. A2L refrigerants are quite safe.

  • @clarkgwozdecki6782
    @clarkgwozdecki6782 5 місяців тому +2

    So basically a very small freon leak in the evaporator and a spark means the customer home goes up in flames. Absolute worst Idea

    • @averyalexander2303
      @averyalexander2303 2 місяці тому +3

      If you are being serious, you totally missed the point of the video. A "very small leak" isn't going to pose any danger at all. Plenty of people's houses have small natural gas or propane leaks for many years without incident and those gases are undeniably MUCH more flammable than R32. No one thinks anything of piping a virtually unlimited supply of natural gas or propane into their house either.
      If the evaporator suddenly blew out then that might be a different story though, I haven't been able to find enough test data out there yet to say one way or the other.

    • @DatNerddSwaqq
      @DatNerddSwaqq Місяць тому

      The only way this could happen is if the entire charge of a typical R32 multisplit (say 4kg) leaks into a room less than 13m3 in size. That's a room 2.7m x 2m. What room in any house is that small but still has an AC unit in it?

  • @legionarios2013
    @legionarios2013 Місяць тому

    The video is unpresentable. It promotes death, lack of seriousness towards technical standards in HVAC and good refrigeration practices. The saddest thing that happens over ASHRAE according to the characteristics of the fluid and its risks. a shame.